Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.4 L+₹22,595 (1.59%)Rejected-AOC 264 2 GALI NO 7 RAM NAGAR ROORKEE DIST HARIDWAR UK | L2 | Rejected-AOC Rejected | |
| 3 | L3₹15.5 L+₹1.3 L (9.43%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹16.0 L+₹1.8 L (12.7%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
12 Sept 2020, 6:00 pmClosed
G E ROORKEE
G E ROORKEE
REPAIR MAINT OF DISTRIBUTION BOARDS INTERNAL ELECTRIC FITTINGS HIGH MAST LIGHT STREET LIGHT TIMER PANEL AND CONNECTED ITEMS CEILING FAN EXHAUST FAN WALL FANS AND ALLIED WORKS IN OTM AND MD ACCN AT SAHARANPUR UNDER GE ROORKEE
2020_MES_366102_2
8391/939/E8
Open Tender
Civil Works
Item Rate
180 days
SAHARANPUR
AS PER NIT
6 documents required · 6 mandatory
₹500
G E ROORKEE
₹40,000
Yes
16 Nov 2020
24 Aug 2020
14 Sept 2020
24 Aug 2020
12 Sept 2020
28 Aug 2020
Amount
S&F LED Tube light fitting 1x20/22 Watt Aluminium extruded industrial box type, bipin holders connector block complete with all accessories internally prewired and incl connecting up three core single wire complete all as spd and directed . Make : Syska/Havells/ Crompton
S&F in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with 9 watt LED bulb PAG series B-22 base complete all as specified and directed.
S&F bulk head fittings IP-65, surface mounted comprising LED luminaire 10W of high brightness Make : Havells : Cat part No. RUGBYNEONFT10WLED 860SSYMTOPC or equivalent Phillips Cat part WT202W LED6S NW PSU S2PC
Taking down carefully UNSV main switches, DBs including MCBs etc complete of any size and capacity .
S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240Volts 200 amps rated busbar 12 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /C&S
S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 8 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /C&S
S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 4 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /C&S
S&F for Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,triple pole and neutral 415volts ,flush to wall complete all as specified and directed. .MAKE-LEGRAND / SCHNEIDER /C&S
M&L for MCB single pole,6 to 40 Amp 240 volt B curve 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed MAKE-LEGRAND / SCHNEIDER /C&S
S&F Miniature circuit breakers ISI marked 240 Volt, 50 Hz, double pole 40 Amps, breaking capacity 10 KA. MAKE-LEGRAND / SCHNEIDER /C&S
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating 20 Amps 240 volt grade MAKE-LEGRAND / SCHNEIDER /C&S
Taking down defective 25/36/40/45/60/250 Watt LED light fitting/SV/MH fittings, street light fitting mounted on pole/bldg on bracket disconnecting, testing all components, dismantling of defective components such as choke, igniters, holders, capacitors, and providing PVC cable for wiring lamps, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and including trimming of branch if obstacle for lights to illuminate the area and then mounting to its original position and making the fitting functional all as specified and directed by Engineer in Charge.
Taking down defective 90 Watt led fitting mounted on 11 mtr long Semi high mast consisting of LED flood light fittings (Approx 4 to 6 Nos), street light fitting, mounted on 11/13mtr long high mast pole on bracket/ round ring, disconnecting, testing all components, dismantling of defective components such as driver of LEDs and cleaning of cover, connection with supply and testing the street light fitting after fixing new components and then mounting to its original position and making the fitting functional all as specified and directed by Engineer in Charge at site.
Taking down defective 250/400 Watt SV/MH lamp type light fittings, High mast light fitting through motorised /manual system, mounted on 21 mtr long high mast pole on bracket/ round ring, disconnecting, testing all components, dismantling of defective components such as choke, igniters, holders, capacitors, and providing new PVC cable for wiring lamps, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and then mounting to its original position and making the fitting functional all as specified and directed by Engineer in Charge at site.
Note for item No 12 to 14 : (i) No T&P will be issued by the Department. (ii) Rates quoted by contractor will include cost of the starter, bipin holder, pvc wire, capacitors, required for maintenance of Street Lights for TL fitting/HPSV fitting. (iii) Rates also include repairing of defective street light timers, fault in street light feeders etc (iv) During whole period of currency of contract any fitting will not be considered for more than once for the payment purposes. (v) Spares such as choke, igniters, driver of LEDs, lamps, holders (supplied by contractor) shall be paid and measured separately under appropriate items.
Supply only HPSV/MH open construction electromagnetic ballast consisting of high quality silicon steel lamination, super enamelled copper wire, vacuum impriganated with white resin terminal block with tapping for 220/240 volt ,50 hz of 400 watt.
Supply only HPSV/MH open construction electromagnetic ballast consisting of high quality silicon steel lamination, super enamelled copper wire, vacuum impriganated with white resin terminal block with tapping for 220/240 volt ,50 hz of 90 watt.
Supply only HPSV/MH open construction electromagnetic ballast consisting of high quality silicon steel lamination, super enamelled copper wire, vacuum impriganated with white resin terminal block with tapping for 220/240 volt ,50 hz of 250 watt.
Supply only MH lamp SE/DE tubular suitable for integral / non integral street/flood light luminaries of capacity 400 Watt Make Havells/Bajaj/Wipro/CG.
Supply only MH lamp SE/DE tubular suitable for integral / non integral street/flood light luminaries of capacity 250 Watt Make Havells/Bajaj/Wipro/CG.
Supply only electronic igniters suitable for 150/250 Watt SV/MH street light fitting 240V, 50HZ complete all as specified and directed .Make Havells/Bajaj/Philips/CG.
Supply only porcelain holder suitable for 150/250 Watt SV/MH SE/DE lamp fitting complete all as specified and directed .
Supply and fixing in repair cable PVC insulated and PVC sheathed size 4 Sqmm twin core stranded aluminium conductor complete all as specified and directed .
M&L for bracket made of GI light grade pipe 1.2 Mtr long of size 40 mm bore bend to shape as per site requirement fixed to pole with 40 x 5 MM -02Nos, size clamps bolts, Nuts, washers including painting two coats of aluminium paint over a coat of primer all as specified and directed by E-I-C
Supply and fixing LED flood light luminaries of 250W, with pressure die cast aluminium housing with sealed toughened glass cover in frame ,IP 65 protection and with all fixing arrangement , nuts, bolts and washer connecting to electric system with 2.5 Sqmm PVC Aluminium stranded conductor 2 core up to require length and to be fixed on 11 Mtr long pole including taking down old unserviceable fitting any type and description complete all as specified and directed. Make- C&S cat part No LTEF250WHPLED, or equivalent in Syska, Bajaj.
Taking down unserviceable security light fittings and supply and fixing new generation energy saving & environment friendly, powder coated pressure die-cast aluminium IP65 roadway luminaries with LEDs with lens as light source & exclusively designed along with electronic driver type street light fitting suitable for 90 watt capacity LED lamp with and including all accessories duly pre-wired, fixing on existing bracket and taking down the unserviceable light to store at site for street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make-C&S Orion 3.0 Series, Cat part No:LTEF90WHPLED, or equivalent in Havells, CG,Syska, Bajaj
Taking down unserviceable security light fittingsSupply and fixing new generation energy saving & environment friendly, powder coated pressure die-cast aluminium IP65 roadway luminaries with LEDs with lens as light source & exclusively designed along with electronic driver type street light fitting suitable for 60 watt capacity LED lamp with and including all accessories duly pre-wired, fixing on existing bracket and taking down the unserviceable light to store at site for street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make- C&S cat part No LTESS60WLED/LS, Havells, CG.
Taking down unserviceable security light fittingsSupply and fixing new generation energy saving & environment friendly, powder coated pressure die-cast aluminium IP65 roadway luminaries with LEDs with lens as light source & exclusively designed along with electronic driver type street light fitting suitable for 45 watt capacity LED lamp with and including all accessories duly pre-wired, fixing on existing bracket and taking down the unserviceable light to store at site for street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make- C&S cat part No LTESS45WLED/LS, Syska, Bajaj.
Taking down unserviceable security light fittingsSupply and fixing new generation energy saving & environment friendly, powder coated pressure die-cast aluminium IP65 roadway luminaries with LEDs with lens as light source & exclusively designed along with electronic driver type street light fitting suitable for 30 watt capacity LED lamp with and including all accessories duly pre-wired, fixing on existing bracket and taking down the unserviceable light to store at site for street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make- C&S LUMIFLO cat part No LTESSR30WLED/LS, Syska, Bajaj or equivalent
S&F in repair nature time switch single phase model swadeep -02 sensor only along with switching timer complete all as specified and directed by Engineer-in-Charge.
S&F in repair contactor 65 Amp 3 Phase , 415 V , as per IS 13947-4-1 ,suitable for nature time switch model swadeep -02 complete all as specified and directed by Engineer-in-Charge. Make :- Havells, Type: CN565T11*, Cat No. IHPAA065511* or equivalent BCH, L&T, CG , Siemens.
S&F in repair contactor 95 Amp single Phase , 240 V , as per IS 13947-4-1 ,suitable for nature time switch model swadeep -02 complete all as specified and directed by Engineer-in-Charge. Make :- BCH or equivalent in L&T, CG , Siemens.
S&F in repair Pneumatic Timer Block for 65 to 95 Amps single Phase , 240 V , as per IS 13947-4-1 ,suitable for nature time switch model swadeep complete all as specified and directed by Engineer-in-Charge. Make :-Havells, Type :CPT2A, Cat No.IHNF6000
Supply and fixing in replacement clear acrylic cover with gasket packing for SV/ MH lamp fitting up to 250 W capacity as per existing fitting at site complete all as specified and directed.
M & L in replacement DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 Sqmm 2/4 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut ,bolts and including provn for fixing 01 no of single pole MCBs 6-32 amps,10KA and MCB TPN 6-32 amps, 10 KA, ‘B’ series = 01 No inside the box complete all as specified and directed. Make :- Sintex/Hensel/standard or equivalent.
M&L for fixing MCB single pole on pole junction boxes, MCB of 6 to 32 Amp, 240 volt B curve 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed MAKE-LEGRAND / SCHNEIDER /HAVELLS
S&F in repair LED driver 75 watt, single Phase , 240 V , make : Crompton cat part No, X075C070V107FNY1BO forLED street light fitting complete all as specified and directed by Engineer-in-Charge.
S&F in repair LED driver 45 watt, Phase , 240 V , make : Crompton Cat part No. S0DQL-65-700-45W for street light fitting complete all as specified and directed by Engineer-in-Charge.
S&F in repair LED driver 25 watt, single Phase , 240 V , make : Crompton Cat part No. S0DVES-36-600-25W for LED street light fitting complete all as specified and directed by Engineer-in-Charge.
S&F in repair surge protection device compatible with outdoor LED fixture, make : Crompton, Cat part No.SRPS-HP-5K-440 for LED light fitting with rated power up to 75W complete all as specified
Supply and fixing 1100 volt grade heavy duty cable PVC insulated solid aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed on Highmast pole connectiuons, for external connections, PVC conduit of 15mm to be used, duly binded to the pole twin core cable flat or circular of size 6 Sqmm all as specified. Make:- Plaza /Havells/Grandlay
Supply only PVC insulated multistrand Copper Cable 3 core size 1 sq mm for bldg/security light fittings connections.
Supply and fixing MCCB 250 Amp 4 pole 25 KA with thermal magnetic release setting with 100% Icu complete all as specified and directed. Make;- Legrand catpart No 4202 19/ Siemens/ Schneider or equivalent
S&F in repair electronic ballast for 36 W/40W fluroscent tube light street light fittings. Make: Havells Cat Part No. LHBF28904025, C&S, Crompton, Phillips or equivalent.
S&F in repair Pin type LED PL, 18 W, 1' length for Bajaj street light fittings . Make: Phillips Cat Part No. LEDPL-L 18 6500K 2G11, C&S, Crompton, Phillips or equivalent.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming excavated hard/soft soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested, complete all as specified and directed.
Removing excavated surplus materials obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
Material and labour for clean dry sand in trenches/ducts for cushioning to cable, complete all as specified and directed. (Note. Punned depth of sand shall be measured for payment purpose.)
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable, complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundation of stay assembly etc including necessary form work, complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles, including necessary form work finishing even and smooth without using extra cement, complete all as specified and directed. Note:- Dismantling of broken coping on existing pole shall be done by contractor and quoted rate shall be deemed to be included.
Supply only Insulation electric tape roll 20 mm 25 mtr long complete.
Supplying, Laying and Jointing testing and commissioning cable PVC insulated and PVC sheathed armored XLPE cable LT 1100 grade heavy duty with 10 Sqmm 2 core, Stranded aluminum conductor through pipes in ducts. Poles/ trenches incl fixing of aluminium lugs, making good to disturbed surface etc for the following cross sectional area complete and specified as directed by EIC :-
Supplying, Laying and Jointing testing and commissioning cable PVC insulated and PVC sheathed armored XLPE cable LT 1100 grade heavy duty with 16 Sqmm 2 core, Stranded aluminum conductor through pipes in ducts. Poles/ trenches incl fixing of aluminium lugs, making good to disturbed surface etc for the following cross sectional area complete and specified as directed by EIC :-
M&L for Painting of single LT steel tubular, structure including. cleaning and scrapping the old surface and then applying two coat of aluminium synthetic enamel paint over a coat of red oxide primer on all steel structure mounted on pole viz. Cross Arms , Clamps, bolts, nuts, brackets etc. and including painting of pole/ structure ith two coat of synthetic black & yellow enamel paint strip 300 mm wide alternative from bottom to upward of LT pole up to height of 1.5 mtr above the embedded portion of GL and writing pole number balance portion of pole shall be painted with two coats of Aluminium enamel paint over a coat of red oxide primer, complete the following as specified and directed :- Notes: - (i) Pole will be cleaned with steel brush to remove old unserviceable paint or scrapped complete surface. (ii) All poles will be numbered all as directed at site. (iii) If painting of poles not properly and not satisfied by JE/Engr-in-charge shall not be paid to contractor or otherwise repaint without extra cost.
M & L for prunning of tree branches of any sizes and dia, not less than 2 Mtr around the LT /HT OH line which obstructing the power supply/ maintenance of electric supply as well as illumination in area including repair of damage broken ACSR conductor, GI wire and jumpers and disposed exc 50 mtr away clearing area and testing of line, complete all as specified and directed. Note : (i) Span length is aproximate 40 to 50m. (ii) Rate quoted are inclusive of repair to damage work in item.
Taking out unserviceable UG Cable of any size
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interior dimensions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3of SSR 2009 including testing after completion.
Taking down ceiling/exhaust/wall mounted fan of any size and sweep from its position dismantling fan for servicing and overhauling of following type and size of Fan by dismantling carefully and removing & changing unserviceable parts, dust & grease, cleaning of internal parts with kerosene oil, washing, checking of alignment of shaft, oiling and re-greasing of bearing/bushes including re-assembling, re-fixing in existing position and connecting to electrical system, testing etc complete at site all as specified & directed Engineer-in-Charge.(Note : Bearing, bush, condenser and painting shall be measured and paid separately.)
(a) Ceiling Fan complete up to 1400 mm Sweep
(b) Ceiling fan complete 1200 mm Sweep
(c) Exhaust Fan up to 450 mm Sweep
(d) Wall mounted fan up to 400 mm sweep
Supply & fix following items for replacement of defective accessories :-
(a) Ball bearing for ceiling Fan No 6201 (Make : TATA/NBC/SKF)
(b) Ball bearing for ceiling Fan No 6202 (Make : TATA/NBC/SKF)
(c) Ball bearing for ceiling Fan No 6203 (Make : TATA/NBC/SKF)
(d) Ball bearing for ceiling Fan No 6204 (Make : TATA/NBC/SKF)
(e) Ball bearing for exhaust Fan of 300/450 mm sweep.
(f) Ball bearing for wall mounted Fan of 300/450 mm sweep.
(g) Gun metal bush suitable for 1200/1500 mm sweep ceiling Fan.
(h) Fan condenser of capacity 2.5 mfd epoxy filled type (Make : Universal/Sarada/Epcos)
(j) Fan condenser of capacity 3.15 mfd epoxy filled type (Make : Universal/Sarada/Epcos)
(k) Fan condenser of capacity 4 mfd epoxy filled type (Make : Universal/Sarada/Epcos)
(l) Rubber bush with split pin for ceiling fan
(m) Armature shaft for Ceiling Fan
Materials and labour for rewinding of following Fans with heavy duty super enameled copper wire of existing gauge including all insulation materials, varnishing, heating etc complete all as directed by Engineer-in-Charge :-
(a) Ceiling Fan complete 1200 mm Sweep
(b) Ceiling Fan complete 1400 mm Sweep
(c) Exhaust Fan upto 350 mm Sweep
(d) Exhaust Fan 350 to 450 mm Sweep
(e) Wall mounted fan upto 400 mm sweep
M&L for painting of following Item with two coats of DUCO paint (ISI grade) white using spray machine spray painting with marking fan number including cleaning, washing and preparation of old painted surfaces complete all as directed by EIC:-
(a) Ceiling fan upto 1400 mm sweep complete.
(b) Ceiling fan upto 1200mm sweep complete
(c) Exhaust fan upto 450 mm sweep with black paint.
(d) Wall mounted fan upto 400 mm sweep.
M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified.
S&F canopy for ceiling fan of existing size & make as required at site all as specified and directed by EIC
Supply and replace down rod heavy grade 15 mm dia complete with drilling holes , cutting making threads as per requirement length up to 1.25 mtr , white paint all as specified and directed
S&F exhaust fan blade set complete suitable for 300/350/450 mm size any make /type or as required at site.
S&F exhaust fan frame with clamps, bolt, nuts and louver of suitable size and as required at ground for 300/350/450 mm sweep.
S&F in replacement hanging clamp with bolt, nut, washer, of appropriate size suitable for down rod of ceiling fan any sweep, specification as per existing or samples, all as directed.
KISHORE CHAND DINESH CHAND
SHRI RAM ENTERPRISES
janta tradrers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .