Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹22.8 L+₹1.3 L (5.87%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹24.3 L+₹2.7 L (12.7%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹24.8 L+₹3.3 L (15.2%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹25.1 L+₹3.5 L (16.4%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹28.1 L
EMD Value
₹56,120
Closing Date
26 Jul 2022, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar 152116
SPECIAL REPAIR TO TOILET AND BATHROOM OF BUILDING NO P-138 (OTM ACCN) OF INF BN-II AT MIL STN ABOHAR
2022_MES_533333_1
GE ABH-19/22-23
Open Tender
Civil Works
Item Rate
180 days
Abohar Mil Stn
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer Abohar
₹56,120
16 Sept 2022
24 Jun 2022
28 Jul 2022
24 Jun 2022
26 Jul 2022
7 Jul 2022
Amount
SCHEDULE 'A' SECTION I (B&R Portion)
Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified .
M & L for 75mm thick cement concrete type C – 2(using 40 mm graded aggregate) (1:3:6) as in plinth protection finished cement concrete surface even & smooth with using extra cement etc all as specified .
Forming contraction(Dummy)joints 65mm deepx10mm wide filled with sealing compound grade 'A' complete all as specified and directed.
Dismantling brick tiles in floor or in roofs laid dry and pointed in cement mortar all as specified .
Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof roof complete all as specified and directed by Engineer-in-Charge.
M&L 40mm thick brick tiles laid on tiles are bedded in cement mortar (1:6) or lime mortar (1:3), 15mm thick and joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound as described in para 11.27.3 of MES SSR Prt-I complete all as specified and directed by Engineer - in - Charge.
Ditto ser itme no 07 above but except bricks tiles complete all as specified and directed by Engineer - in - Charge.
M&L Preparing surfaces of old roof slab and cleaned of all foreign materials such as fungues, moss, dust etc, bu wire brushing dusting, sprinkling water on the surface and ensure water does not stand any where. If it is so, the roof surface shall be levelled then surface shall be painted with one coat of cold aplied bitumious primer @ 0.40 ltr per sqm, applied over primed surface APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm)land on primed surface by forced application complete all as specified and directed by Engineer - in - Charge.
Demolition of reinforced cement concrete of any description and in any position as in roofs, floors (other than ground floor), beams, landing, chajjas and similar suspended work.
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate in slab supported on walls,beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like all as specified and directed. (form work & reinforcement measured separately).
M & L mild steel TMT bars 10mm dia or over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as in column, beam etc .
M&L for Form work to soffits of suspended slabs such as roof slabs,floor slabs,landings and similar work not exc.200 mm thick(horizontal or sloping)rough finish surface of concrete flat all as specified and directed.
M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in cover slab of drain/manhole set in cm (1:6) . ( Note : Cost of Form Work is deemed to be inclusive of unit rate quoted by the contractor & reinforcement shall be measured & paid Separately.)
Taking down chowkats or frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store all as specified.
Taking down chowkats with shutters(without taking off shutters from the frame exceeding 1.50 sqm each but not exceeding 4 sqm)
Supply and fixing Fiber Glass Reinforced plastic (FRP)Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs.The frame shall be covered with fiber glass from all sides.M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
S & F MS butt hinges, medium weight 100 mm size of make Prayag or equivalent
S & F aluminum tower bolt 150 mm of all as specified.
S & F door handl D type 150 mm of PTMT all as specified.
Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc.
M & L for rendering 15mm thik on fair faces of brick work in cement mortar 1:6 finished even & smooth without using extra cement.
M & L for rendering 15mm thick on fair faces of brick work in cement mortar 1:4 finished even & smooth without using extra cement.
M&L rendering 10 mm thick in cement mortar 1:3 on fair faces of concrete surfaces of ceiling finishing even and smooth without using extra cement.
M&L Integal water proofing compound
M&L for two coat of cement base paint over a coat of alkali resistant cement primer on newly plastered surface including preparation of undecorated surface complete all as specified and as directed
M & L Preparation of newly plastered wall surfaces and applying three coats of white wash including preparation .
M&L preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling.
M & L one coat of white wash on old decorated plastered or unplastered surfaces of ceiling including preparation of surfaces complete all as specified and directed by Engineer - in - Charge .
M & L one coat of white wash on old decorated plastered or unplastered surfaces of walls including preparation of surfaces all as specified and directed by Engineer - in - Charge .
M & L two coats of cement base paint over old surfaces including preparation of surface complete all as specified .
Shotcreting 25MM thick in RCC columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characterristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of certering and shuttering at edges and corners etc as directed by Engineer-in-Charge including Chipping of unsound /weak concrete material 25 mm average thickness from slabs,beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@ 6sqm/ltr at DFT of 100microns as per specifications and disposal of debries for all lead and lifts all complete as per direction of Engineer-in-Charge.
S&F Hard drawn steel wire fabric not exc 4Kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt all as specified & directed by Engineer-in-Charge.
M & L 5mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge .
Dismantling structural steel work including doors,gates but excluding framed truss etc.
S & F framed work such as grills, cooler stand ,ladder grating and sun shed etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming to Fe 410-0 or Fe 310-0 all as specified .
M & L providing two coats of synthetic enamel paint over new surface and a coat of red oxide primer on steel surfaces including preparation of surface of any description not exceeding 10 cm width or girth all as specified .
Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the permices.
S&F glazed ceramic coloured tiles joint free 350x250x7mm/450x350x7mm square or rectanguler as on walls etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM 1:4
M&L Non skid ceramic coloured /printed tiles 7 to 8 mm thick( square /rectangular) area of each tile exc. 0.11 sqm but n. exc, 0.18 sqm in floor and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade over and incl 15 mm th screed bed in CM 1:6 complete all as specified and directed by Engr in Charge.
M&L cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate as in floors 25 mm thick for tiles all as specified.& directed by Engineer -in-charge..
M&L 20mm thick granite (of any type ) work (table rubbed and polished ) in cooking platform and like in cm (1:4) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Demolition of cement concrete ( un re-inforced) of any description in ground floor and pavings Nexc15 cm thickness (below or above GL)
Method 1 (A) - Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, SmartCare Damp Block 2K or approved equivalent , having 100 % elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5.Clean all working surface & made free from dirt, grease laitance etc. After inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 Cement : 1Polymer : 4 Sand).Making Gola of size 75X75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 . (1 Cement : 1Polymer : 4 Sand). The coating shall be terminated at 300mm on vertical walls. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc., complete as per manufacturers specifications. (B) Bore Packing: All the borehole gaps between concrete surface and pvc pipe of various dia upto the neck level shall be filled with non-shrink free flow grout - SmartCare GP Grout or approved equivalent having dual shrinkage compensation property. Before the bore packing, surface of the pvc pipe and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent. (c) Apply 12-15mm plaster on slab and vertical surface admixed with SmartCare Vitalia Neo @200ml per bag of cement Method 2 (A) M & L for water proofing treatment to RCC sunken slab and adjoining vertical slab, Providing & applying two component cementitious & acrylic flexible waterproofing & protective coating, two coats with 1mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance, cm/km is 0.09 of Dr Fixit Pidifin 2k @ 1.5kg/sqm or equivalent with a paint brush over existing roof surface. The Polyester reinforced coated net of 45g/m2, 2.5mmx2.5mm is Laying on the surface immediately on the first coat of two component modified polymer Dr Fixit pidifin 2k or equivalent. After removal of all loose materials like dust etc. With wire brush coir brushes from roof surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based repair mortar/micro concrete, after the repairing work making the gola on surrounding wall’s junction and seal the vertical walls up to 300mm. In case of core cutting on the surface, the joint is seal with non-shrink grout. The work complete as per the direction of Engineer-in-Charge. (Work shall be executed through specialized agency) Note: (i) The treatment shall be carried out as per the manufacturers instructions and as directed by the Engineer in charge. The name of firm shall be got approved from CWE before carrying out the work. (ii) The Plan area of floor shall be considered for payment and provn of cement work is excluded from quoted rate for this item. (iii) Plaster shall be measured and paid separately. (iv) PCC filling under sunken area will be measured & paid separately OR:- Techno commercial equivalent in Fosroc/Sika/STP
M & L PCC (1:5:10) using 40mm graded burnt bricks aggregate as in foundation filling & mass concrete or as in sunken floor complete all as specified & directed by Engineer-in-charge
Dismantling water tanks and removing to store of exc 500 nexc 1000 ltr capacity
S & F rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 1000 Litres all as specified and directed by Engineer - in - Charge .
S&F in repair 20mm Ball brass valves, high pressure, with polytheene float and flynut complete, screwed for iron pipe orr brass ferrule and fixed.
S & F in 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified .
S & F in 25 mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified .
S&F in repair PVC low level flushing system 10 Ltr capacity with flush pipe complete as approved by Eng-in charge.
S&F in repair Viterous China squating pan Orrisa pattern size 580/440mm wash down water closet pan ,white (excluding fixing bolts, flushing cistern and flush pipe) with plastic seat cover.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, sheet cover complete.
S&F in repair plastic water closet seat, white closed patern withflat bottom and cover and mild steelcromium plated or aluminium hinging device
S&F in repairs vitreous china Half stall urinals flat back white minimum with grating and union for discharge pipe , providing & fixing plugs, bedding urinal against wall in CM 1:2 , securing urinal to plugs with & incl 60mm long brass screws, pointing around urinal back in cement , fixing automatic flushing cistern with nbrackets, flush pipe, grating and union for discharge pipe complete all as specified.
S & F in repairs vitrous china oval wash hand basin white of size 550X400 mm including brackets 300mm long PVC connection with brass nuts, 40mm dia waste coupling including cutting for and pinning in end of brackets or erecting stand etc coloured top bowl type screwed shank fly nut flange end including cutting for and pinning in granite slab of hole including 32 mm dia chromium plated waste coupling and bottle trap all as specified .(MAKE- Hindwareor equivalent in Parryware)
S & F in repairs 15 mm bore concealed stop cock cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed but fancy type chromium plated with long shank and cup (Concealled type)
S&F in repairs 15mm bore stop valve fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.
S & F in repairs 15 mm bore bib tap fancy type chromium plated with crutch or butterfly handle screwed down ,screwed for iron pipe all as specified.
S/F in repairs pillar taps 15mm bore fancy type chromium plated cast copper alloy with capstan heads scre-wed down high pressure with or without lettered hot' or'cold' with long screwed shanks and fly nuts screwed for iron pipe . ISI marked
S&F in repair brass chromium plated shower Rose 125mm size with swivel joints,any size, incl shower arm fixing to pipe or union complete all as specified and directed by Engr-in-charge.
S&F in repair PVC connection both side brass unions internal for size 15mm dia and 450mm long all as specified and directed by Engineer-in-Charge.
S&F EWC Jet spray complete all as specified and directed.
S & F soap dish fixed as chromium plated brass.
S&F peg set of stainless steel solid body of 125mm to 175 mm having 6 Nos hooks fixed with brass chromium plated screws complete in all as specified
Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store
Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store
Taking up or down steel tubing of 25 to 32 mm bore and connections, including cleaning for re-fixing or removal to store
Supply & fixing mild steel tubes of size 15mm bore (medium grade) galvanised with all fittings and fixed complete to wall all as specified & directed by Engineer-in-charge.
Fixing only mild steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
Supply & fixing mild steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
Fixing only mild steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
Supply & fixing mild steel tubes of size 25 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
Fixing mild steel tubes of size 25 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
Dismantling of cast iron pipes jointed in cement mortar and taking out from trenches walls etc upto 100 mm bore all as specified and directed by Engineer - in - Charge .
S & F PVC(SWR) 110 mm bore Pipes single socketed in any length with rubber ring joints,laid in trenches or in floors IS 4985-2000 in pressure rating 6Kgf/sq.cm and complete all as specified and directed by Engineer - in - Charge all as specified and directed by Engineer - in - Charge.
S & F PVC(SWR) 75 mm bore Pipes single socketed in any length with rubber ring joints,laid in trenches or in floors IS 4985-2000 in pressure rating 6Kgf/sq.cm and complete all as specified and directed by Engineer - in - Charge all as specified and directed by Engineer - in - Charge.
S&F PVC (SWR)branch pieces single /double (equal or unequal) ordinary or inverted with parallel branches 110mm bore IS 4985-2000 in pressure rating 6Kgf/sq.cm and complete all as specified and directed by Engineer - in - Charge
Ditto all as above but 80 mm bore.
S&F PVC(SWR) bend ( any radius) dimenshing pieces or tappers ( large bore measured) 110mm bore IS 4985-2000 in pressure rating 6Kgf/sq.cm and complete all as specified and directed by Engineer - in - Charge
-ditto- all as above but 82 mm bore
S & F PVC(SWR) Vent cowls 110mm bore all as specified and directed by Engineer - in - Charge.
S & F PVC(SWR) Vent cowls 75 mm bore all as specified and directed by Engineer - in - Charge.
S&F for 100 mm bore PVC (SWR) plain floor trap with grating including jointing with solvent cement.
S&F for 75 mm bore PVC (SWR) plain floor trap with grating including jointing with solvent cement.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc .
M&L for Brick work using fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Labour only for Brick work built in CM (1:6) with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius with Reusing the old bricks obtained.
SCHEDULE 'A' SECTION-II (E&M PORTION)
Excavation in trenches , n exc 1.5m wide and n exc 1.5m in depth , for foundation , etc or for shaft, well, cesspits , manholes , pier hole etc n exc 1.5 m in depth and getting out comlete all as specified.
Returning , filling in including, spreading , levelling , watering and well reamming in layers not exc comlete all as specified.
Removing excavated material n exc 50m and depositing where as directed at a level n exc. 1.5 m above the starting point comlete all as specified.
Sand filling under flooors or in foundation including and consolidation as as specified and directed at site comlete all as specified.
M & L brick sub class 'B' locally available best quality laid in trenches above sand consolidted forcable protection complete all as specified and directed.
Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 25 sqmm 4 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes including provision of cable gland/aluminium lugscomplete all as specified & directed by Engineer-in- charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
Taking down carefully copper /aluminium point wiring (light ,fan ,socket or power) complete incl fixture and fitting such as Switches, ceiling roses, pandents, regulators,sockets, light fitting etc removing materials to store for keeping in safe custody for taking credit(credit for above items shuold be made as per conditions separately) and making good distrubed surface of wall ,floors etc. complete all as specified and as directed.
M & L point wiring (Concealed) with PVC FRLS insulated unsheathed multistranded copper conductor drawn in and incl of size 1.5 Sqmm, 1100V grade in concealed PVC regid conduit, including provn of of 1.2 mm thich pressed steel sunken terminal boxes 60mm deep,suitable lenthand painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5Sqmm PVC insulated stranded copper conductor as earth continuity wire and connected to common earth dolly with copper lugs inserted in including MS boards complete heavy duty for housing switches, sockets, regulators, bell push etc, complete all as directed for the following.
(A) One light/Bell/fan point controlled by one way switch 5 Amp.
(B) one 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq mm size complete.
(C) one 3 pin socket outlet, 5 Amps on independent board with other switches, with cables 1.5 sq mm size complete.
(D) Ditto but with cable of 2.5 sq mm for 15 amps Socket Independent board with other switches complete all as specified.
Description all as per item No 08 here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
M & L point wiring with PVC FRLS insulated unsheathed multistranded copper conductor of size 1.5 Sqmm, 1100V grade in Existing concealed conduit, and one run PVC FRLS insulated unsheathed copper conductor of size 1.5 Sqmm as earth continuity wire and connected to common earth dolly with copper including provn of of 1.2 mm thick pressed steel sunken terminal boxes 60mm deep suitable lenth and painted with red oxide primer in place of unserviceable shunken box complete for housing switches, , regulators, bell push etc, complete all as directed for the following.
(a) One light / fan point controlled by one way piano switch 5 Amp.
(b) One socket point 5 Amp on an independent board.
(c) One socket point 5 Amp on same board
(d) Ditto but with cable of 2.5 sq mm for 15 amps Socket Independent board with other switches complete all as specified.
S & F switch piano ,flush type single pole, one way 5 amp, 2way 5 Amp,/bell push all as directed.
S & F switch piano ,flush type single pole, one way 6/15 Amps 5 pin complete all as speccified aand directed.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps complete.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps and 15 Amps complete.
M & L for celling rose 3 pin/pvc/ polycarbonate isolated body complete all as specified and as directed.
M&L for LED tube light fitting of LED T5 tube lights (6500K) environomental freiendly energy efficient of 18/20 Watt LED including electric connection with PVC copper flexible twin core cable, 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska SSK-SQ2001 20W or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron of 4 sqmm SWG earht wire fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip upto DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
S&F sheet metal enclouser TPN DB having facility to fix MCCB incomer upto 125Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill ptorector and blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
S & F in sheet metal enclosures for DBs double door type when MCBs to be used single pole & nuteral 8 ways s all as specified and directed by Engg-in-Charge.
S&F MCB SPN 63 Amps, 240 Volts complete all as specified.
S&F MCB SP 6 to 40 Amps, 240 Volts complete all as specified.
M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits and conduit fittings/existing concealed PVC conduit and conduit fittings not less than 25 mm dia complete, including provision of 2x6 sqmm nominal cross sectional area multimultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main all as specified. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
Description all as per item No 30 here in before but ,2 Runs of 6 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed.
Description all as per item No 30 here in before but ,2 Runs of 4 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed.
M & L cutting chases, pinning in, making god to facings where reuired and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as directed by Engr-in-charge .
S & F LED street light luminaitres 20/25 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska max glow series SSK-ST25W-MG or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
Supply and fixing MCCB TPN ( 4 pole) 63 Amps 415 Volts of braking capacity 36 KA (Adjustable Thermal and Adjustable Magnetic Release Setting) complete taking down old unserviceable one and making necessary connections as existing and cleaning the terminals with CTC solutions complete all as specified and directed. Make :IndoAsian Cat No: 830330 to 830335 or equvalent of Havells/LegrandSchneider/HPL/Standard
S & F GI tube light grade galvanised of size 50 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in- Charge.
Taking down/ dismantling complete exhaust fan of size 300/380/450 mm sweep.with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of Exhaust fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete exhaust fan fixing only old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :- Ball bearing and Gun metal bush are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in Schedule Items)
S&F for Condenser 2/2.5 MFD. (Make : Universal (metal body).
S&F for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200mm/1400mm sweep.
Supply only ball bearing number of 6201/6202/6203/6204 as required. (Make : SKF/NBC).
Supply only gun metal bush as required.
Taking down/dismantling complete exhaust fans of any size for spray painting with two coat of synthetic enamel paint of approved colour including filling cavities with filler on coat after cleaning all dust etc. including re-assembling the same and testing after writing of MES NO on completion.
S&F batton holder insulated body with back plate inluding 12 watts LED lamp complete all as specified.
S & F GI tube light grade galvanised of size 40 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in- Charge. (MAKE: JINDAL/PRAKASH/SURYA)
M&L for LED Batten with LED tube light integrated LED channel of capacity 10 Watt white colour complete all as specified and directed by Engr-In-charge. Make: Bajaj BCLSB 10WH or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Syska/Polycab as recommended by Engr-Incharge and approved by GE.
M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as directed by the Engr. in Charge.
Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells Schneider/C&S)
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for hot/cold water.
S&F for copper (CP) hot water pipe 450 mm length (heavy duty) for Geyser, connection with check nut and washer.
Taking down/ dismantling of defective/rusted storage type hot water Geyser of 50/35/25 Ltr capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, de-scaling/cleaning inner shell, servicing etc. Checking defects, re-assembling and re-installing the Geyser in position, connection and testing complete.
M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for 0.4 mpa working pressure for cable passing without damaging existing Raod/path/hardstanding/floor by trenchless technology or manual using necessary equipment complete all as specified and directed.
G S CONSTRUCTIONS
RUCHIKA CONSTRUCTIONS
M/s GURFATEH BUILDERS
M/S VIAJY BUILDERS & DEVELOPERS
RANDHIR AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .