| 1 | L1₹30.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹32.5 L+₹2.0 L (6.62%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹33.6 L+₹3.2 L (10.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹34.4 L+₹3.9 L (12.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹36.7 L+₹6.2 L (20.4%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | ROYAL CONSTRUCTION L1 | M/S RAKESH TRADERS L4 | City buildcom builders & devlopers L3 | JYOTI ENTERPRISES L2 | M/s H V Infra Projects L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline | ||||||||
| 1.10 | Excavating over areas n exc 1.5 m deep and getting out in hard/ dense soil complete all as specified and directed. | 340.2 | Cum | 100 ₹34,020 Lowest | 150 ₹51,030 | 150 ₹51,030 | 135 ₹45,927 | 129 ₹43,885.8 |
| 2.00 | M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation, sub base concrete etc complete all as specified and directed. | 7 | Cum | 2,400 ₹16,800 Lowest | 3,000 ₹21,000 | 2,600 ₹18,200 | 2,700 ₹18,900 | 2,975 ₹20,825 |
| 3.00 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter surface flat rough finished surface complete all as specified and directed. | 100 | Sqm | 240 ₹24,000 | 200 ₹20,000 Lowest | 300 ₹30,000 | 306 ₹30,600 | 285 ₹28,500 |
| 4.00 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surface complete all as specified and directed. | 80 | Sqm | 240 ₹19,200 Lowest | 250 ₹20,000 | 300 ₹24,000 | 306 ₹24,480 | 345 ₹27,600 |
| 5.00 | Use and waste of formwork to sides and soffits of floor or roof beams, bands, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for flat rough finished surface complete all as specified and directed. | 341.7 | Sqm | 240 ₹82,008 Lowest | 300 ₹1,02,510 | 280 ₹95,676 | 306 ₹1,04,560.2 | 299 ₹1,02,168.3 |
| 6.00 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for flat finished surfaces complete all as specified and directed. | 33.75 | sqm | 240 ₹8,100 Lowest | 300 ₹10,125 | 250 ₹8,437.5 | 270 ₹9,112.5 | 415 ₹14,006.25 |
| 7.00 | M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. | 29.36 | Cum | 5,850 ₹1,71,756 | 6,500 ₹1,90,840 | 5,200 ₹1,52,672 Lowest | 6,030 ₹1,77,040.8 | 5,795 ₹1,70,141.2 |
| 8.00 | M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) as in columns, piers, posts etc. complete all as specified and directed. | 12 | Cum | 5,850 ₹70,200 | 6,500 ₹78,000 | 5,200 ₹62,400 Lowest | 6,030 ₹72,360 | 5,795 ₹69,540 |
| 9.00 | M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) as in beams, bands, cantilevers, bressummers, lintels over 1.5 m span etc. complete all as specified and directed. | 8.36 | Cum | 5,850 ₹48,906 | 6,500 ₹54,340 | 5,200 ₹43,472 Lowest | 6,030 ₹50,410.8 | 5,795 ₹48,446.2 |
Tender Value
₹45.1 L
EMD Value
₹90,200
Closing Date
14 Feb 2026, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
PROVISION OF 03 COVERED GALVANISED SQUAD POST WITH INTEGRATED TOILET BLOCK AND STORE ROOM AT AGNIVEER TRG AREA AT 3 EME CENTRE UNDER GE BHOPAL
2026_MES_750008_1
8499/E8
Open Tender
Civil Works
Item Rate
180 days
BHOPAL
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE BHOPAL
₹90,200
Yes
15 May 2026
24 Jan 2026
16 Feb 2026
24 Jan 2026
14 Feb 2026
7 Feb 2026
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Excavating over areas n exc 1.5 m deep and getting out in hard/ dense soil complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation, sub base concrete etc complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter surface flat rough finished surface complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surface complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, bands, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for flat rough finished surface complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for flat finished surfaces complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) as in columns, piers, posts etc. complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) as in beams, bands, cantilevers, bressummers, lintels over 1.5 m span etc. complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, chajjas and the like complete all as specified and directed.
S&F of mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F of mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Supply and filling approved earth (from outside MD land) including spreading, levelling in layers n. exc 25cm, watering and well ramming to a true surface complete all as specified and directed.
Removing excavated material to a distance exc. 1.5 Km but n exc. 5.0 Km and depositing where directed at a level n exc 1.5 mtr above starting point complete all as specified and directed.
M&L for hardcore of broken stone or boulders of gauge n exc 63 mm, deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base concrete complete all as specified and directed.
M&L for forming cconstruction joint 30 mm deep x 10 mm wide and filled with sealing compound grade A complete all as specified and directed.
M&L for brick work with fly ash bricks (modular size bricks) straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for 15 mm thick rendering in CM 1:4 on brick/concrete/stone masonry surfaces, finishing the surfaces even and smooth without using extra cement with and including mixing water proofing compound @ 3% by wt of cement complete all as specified and directed.
M&L for 10 mm thick rendering in CM 1:3 on brick/ concrete surfaces, finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed.
M&L for applying a coat of 1 mm thick white wall care cement based water proof putty on walls/ ceiling, finished even and smooth complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of wall primer complete all as specified and directed.
M&L for 18-20 mm thick machine cut kota stone slab flooring over and including 15 mm thick cement screed base in CM 1:6; laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M&L for 18-20 mm thick machine cut kota stone slab as in riser of steps, skirting, dado and pillar etc; over and including 10 mm thick rendering in CM 1:4; laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M&L for providing cement concrete, 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in coping, bed blocks, lintels, cills, steps, seismic and other similer bands, kerbs and like etc complete all as specified and directed.
S&F in replacement factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other fames/ chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note: M.S. lugs or SS dash fasteners shall be included in the quoted rate of item.
S&F in replacement factory made factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with necessary full body threaded star headed counter sunk S.S screws complete all as specified and directed.
S&F of 100 mm long stainless steel butt hinges, ISI marked, cast type and fixed complete all as specified and directed.
S&F of 150 mm long aluminium handles, cast type, anodised and fixed to shutters complete all as specified and directed.
S&F of 150 mm long aluminium anodised barrel tower bolts, extruded section and fixed complete all as specified and directed.
S&F of 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F of mild steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded including cutting to required length, tubes conforming to IS: 1161- 1979 grade St.-240 complete all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheeting 0.50 mm thick of an colour having tensile strength of 550 Mpa (AZ-150) as in roof covering / cladding to wall, chajjas, etc. and fixed with self tapping screws complete all as specified and directed
S&F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa (AZ-150) as in ridges, hips, valley gutters, drip, straight flashing etc. (length and gith as fixed) and fixed with self tapping screws complete all as specified and directed
S&F of rolled mild steel work as in bands, straps, clamps, hold fasts, wall ties, hooks for hanging fans and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for providing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc; including welding, grinding, buffing, polishing and making curvature (where ever required) and fixing the same with necessary stainless steel nuts and bolts including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
M&L for preparation new steel & iron surfaces of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and n exc 1.5m deep for foundation etc getting out in hard dense soil complete all as specified and directed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc 15 cm thick, spreading, levelled and well rammed to form true surface including watering complete all as specified and directed.
M&L for hardcore of broken stone or boulders of gauge n exc 63 mm, deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for anti-termite treatment to bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for anti-termite treatment to backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M&L for brickwork with sub class 'B' bricks, straight or curved on plan, exc 6 m mean raidus built in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on ceiling surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
S&F in replacement 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in trenches/floors complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends of any radius and jointed with solvent cement complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal and jointed with solvent cement complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) floor trap plain with SS grating, fixed and jointed with solvent cement complete all as specified and direcetd.
S&F in repairs vitreous china urinal, full stall type including providing and fixing plugs, bedding urinal against wall in cement mortar in 1:2, securing urinals to plugs with and including 60 mm brass screws, pointing around urinal back in white cement including CP waste fitting, PVC waste pipe and CP urinal spreader complete all as specified and directed.
S&F in repairs 15 mm bore fancy type pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down high pressure with lettered hot or cold with long screwed shanks and fly nuts complete all as specified and directed.
S&F in repairs 15 mm dia PVC connection of length 450 mm long complete all as specified and directed.
S&F in repairs fancy type chromium plated stop valves 15 mm bore cast copper alloy screwed down high pressure with capstan head, screwed for iron pipe or for union complete all as specified and directed.
M&L for non skid ceramic light coloured tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exceeing 0.18 sqm as in floors over and including 15 mm thick screed bed in CM 1:6; set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles including dismantling of old floor, hearth or wall tiling including cement mortar bedding and removing rubbish off the permises complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with multi-stranded copper conductor stranded copper conductor 1.5 Sqmm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable, 1100 volts grade in and including medium grade, PVC concealed conduit and conduit accessories of not less than 20 mm dia, concealed in wall/ floor etc, ISI marked with sheel metal mild steel flush box, white cover plate with frame for fixing modular switches, sockets and fan regulators etc. including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.
All as per item No 57.00 here-in-before but for one 3 pin socket outlet, 5 Amps on same board complete.
All as per item No. 57.00 here-in-before but for one 3 pin socket outlet, 5 Amps on independent board complete.
All as per item No. 57.00 here-in-before but for point wiring with 4.0 Sqmm FRLS mutistranded copper conductor cable for 5/ 15 Amps, switch socket combination on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete.
S&F of modular switch piano, one module, single pole, one way, 6/ 16 Amps, 240 volt, 50Hz, AC complete all as specified and directed.
S&F of ceiling rose surface bakelite, three terminals, 230 volt AC complete all as specified and directed.
S&F of modular socket outlet, 2 module, multipurpose having provision for 2/3 pin, 6/16 Amp, 230 volt AC complete all as specified and directed.
S&F in replacement new ceiling fan, BEE 5 star rated, B/S certified BLDC decorative ceiling fan of 1200 mm sweep, 230 Volts, Min dia delivery 225 CFM, anti dust, aerodynamic aluminium blades & body with advanced brushless technology bosed BLDC copper winding motor with all accessories such as regulator, conneting down rod, clamps, canopy, remote with boost, timer & sleep mode complete all as specified and directed. Make- Bajaj/ Orient/ Havells/ CG/ Atomberg Note: (i) Cost of taking down old ceiling fan, regulator & deposit to MES Store yard is includes in the unit rate quoted by the contractor.(ii) Warranty of BLDC ceiling fan for 2 year & 5 Year of BLDC Motor.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100 V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. of 25 mm external diameter and PVC insulated stranded copper conductor of 4 sqmm nominal cross section area as earth wire complete all as specified and directed. Note: Three runs of 4.0 sqmm cable & PVC conduit pipe shall be measured as one unit length.
S&F of LED 20/21 Watt tube light fitting (T8 type) including LED retrofit tube 20/21 W one side connection type, 240 V, PF ≥ 0.90, colour temp 6500 K, system luminious efficacy ≥ 100 Lm/W complete with powder coated CRCA decorative patti suitable for surface mounting on wall including making connection with PVC insulated multistranded copper flexible cable 0.5 sqmm two core and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified and directed.
S&F of LED light fitting mirror type with high out put diffuser of 2 feet long, 10 watt, 220 Volts AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 Amps rated bus bar, 8 way, double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 protection complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 Amps rated bus bar, 4 way, double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 protection complete all as specified and directed.
S&F of MCB, SPN, 32 Amps, 240 Volts AC supply, C Curve with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed.
S&F of MCB, SP, 6 to 32 Amps, 240 Volts AC supply, C Curve with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed.
S&F of exhaust fan, rust proof steel body, 230 Volts AC, single phase of size 300 mm sweep with blades, frame and louvers and all necessary fittings with and including drilling of hole and repairing of disturbed surfaces complete all as specified and directed. Note: Old exhaust fans shall be deposited in AGE E/M store yard.
Excavation in trenches not exc 1.5 m wide and n exc 1.5m deep for foundation etc getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in any type of soil including spreading, levelling, watering and well ramming in layers n. exc 25 cm complete all as specified and directed.
Removing excavated material to a distance n exc. 50 m and depositing where directed at a level n exc 1.50 m above starting point complete all as specified and directed.
M&L for earthing complete with galvanised steel plate earth electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of size 4 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 x 40 x 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 15 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. Note:-Compacted/punned thickness shall be measured & paid.
Supply and laying of factory made precast concrete cable cover, class LV, Type I, flat, size 250 x 150 x 40 mm for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 16 Sqmm, 4 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc; including taking out old unserviceable cable, any type complete all as specified and directed.
Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 6 Sqmm, 2 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc; including taking out old unserviceable cable, any type complete all as specified and directed.
S&F of 25 mm GI tubing light grade (as per IS -1239) with all fittings as required for passing through cables under floors, along the wall/ pole, etc; complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 0.00
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
BOQ_839989.xls
BOQ • 8.22 MB
TENDER_DOCU_8499.pdf
Tender Documents • 1.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .