Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹12.1 LAdmitted-Finance | -42.05% | ₹12.1 L | L1 | Admitted-Finance |
| 2 | L2₹12.5 LAdmitted-Finance | -40.01% | ₹12.5 L | L2 | Admitted-Finance |
| 3 | L3₹12.5 LAdmitted-Finance 197 KRISHNA NAGAR JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | -40.00% | ₹12.5 L | L3 | Admitted-Finance |
| 4 | L4₹12.6 LAdmitted-Finance | -39.59% | ₹12.6 L | L4 | Admitted-Finance |
| 5 | L5₹12.8 LAdmitted-Finance | -38.70% | ₹12.8 L | L5 | Admitted-Finance |
Tender Value
₹20.8 L
EMD Value
₹41,680
Closing Date
10 Mar 2026, 6:00 pmClosed
Er. Sanjeev Sharma
XEN PWd Akhnoor
BOQ
2026_PWDJK_303599_2
e-NIT No. 73 of 2025-26 Dated 17-02-2026
Open Tender
Civil Works
180 days
Akhnoor
NIT
2 documents required · 2 mandatory
₹600
XEN PWd Akhnoor
₹41,680
8 Apr 2026
18 Feb 2026
11 Mar 2026
18 Feb 2026
10 Mar 2026
18 Feb 2026
Earthwork in excavation by manual means in trenches for foundation,drains, pipes,cables etc(not exceeding 1.5 mt in width)and for shafts,wells cesspits and the like not exceeding 10sqm on plan depth up to 1.5mt including disposal of excavated earth up to 1 mt from cutting edge disposed earth to be levelled and neatly dressed. All kinds of soils .
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All works up to plinth level in M-7.5(1:4:8) grade, with 40mm nominal size of aggregates. Crushed
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- all works upto plinth level 1:3:6(1 cement 3 coarse sand 6 graded stone agg. 20 mm nominal size) crushed
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering. shuttering, finishing and reinforcement-All work upto plinth level 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size)
Providing and laying in position cement concrete of specified grade of reinforced cement concrete, excluding the cost of centering and shuttering. in 1:1.5:3 (1 cement:1.5 coarse sand: 3 graded stone aggreate 20mm nominal size in suspended floors, balconies,landings and staircase having upto 15 degree slope excluding cost of centering and shuttering.All work upto floor V level.
Reinforcement for RCC work including straightening cutting,bending,placing in position & binding all complete with TMT bars.
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 75 in foundation and plinth cement mortor 1:6 (1 cement 6 coarse sand and extra for brick work in super structure above plinth level up floor 5 level (by manual means)
Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Angle 40x40x6mm
Centring and Shuttering including strutting, propping etc and removal of form work for foundation , footings , basis of columns etc. for mass concrete.
Centring and Shuttering including strutting, propping etc and removal of form work for Lintels, beams ,plinth beams ,girders,bressumers and centilevers.
Centring and Shuttering including strutting, propping etc and removal of form work for Suspended floors, roofs, landings, balconies and access platform
Centring and Shuttering including strutting, propping etc and removal of form work for Edges of Slabs and Break in floors and walls under 20 cm wide
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.
supplying and filling in plinth with fine sand under floors including watering ramming consolidating and dressing complete
12mm Cement plaster of mix 1 : 4 ( 1 cement : 4 fine sand)
15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 4 ( 1 cement : 4 fine sand)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to steel windows by welding 10 mm square bar 4" c/c
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including lSI marked M.S. pressed Butt hinges bright finished of required size with necessary screws excluding panelling which will be paid for separately,all complete as per direction of engineer- in charge.second class kail wood
Providing and fixing glazed shutters for doors, windows and clerestory windows using 10kg/sqm (4mm thick) float glass panes including lSI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 35mm thick second class kail wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked
6mm ceemnt plaster to ceiling pf mix 1:3(1 cement 3 fine sand)
Distempering with oil bound washable distemper ofapproved brand and manufacture to give an even shade. New work (two or more coats) over and including priming coat with cement primer
Finishing walls with water proofing cement paint of required shade New work (two or more coats) applied @3.84 kg/10sqm
Painting with ready mixed synthetic enamel paint of approved brand and manufacture in all shades to give an even shade New wood work (two or more coats)
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- all works upto plinth level 1:2:4(1 cement 2 coarse sand 4 graded stone agg. 20 mm nominal size) crushed
Providing and fixing electic point complete in all respects as per directions of Engineer incharge
Engagement of painter for Writing name of school
Making plinth protection 50mm thick with cement conc. (1:3:6), 20mm nominal size of stone aggregates over 75mm bed of dry brick ballast, 40mm nominal size of well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. Size of tile 600x600 mm
Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre
Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868
i. Sliding door bolts (300 x 16mm) (Code No.9.95)
tower bolt200x10mm
tower bolt100x10mm
handle 125mm
handle100mm
twin rubber stopper
hooks and eyes
providing and fixing of foundation stone
Carriage of materials by mechanical transport inculding loading / unloading and stacking complete. Sand lead up to 5 kms.
Carriage of materials by mechanical transport inculding loading / unloading and stacking complete. Stone aggregate below 40 mm lead up to 5 kms.
Carriage of materials by mechanical transport inculding loading / unloading and stacking complete. BrickS. 10KMS
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_985920.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
BOQ_985920.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid