Supply of 3 TR indoor unit and 4 HP VRF outdoor unit
BLUE STAR / IVRFB04SC
8415
2 Job
138,099.2
276,198.4
Installation of Indoor and outdoor of VRF Machine
BLUE STAR / IVRFB04SC
8415
2 Job
9,440
18,880
VRF System Refrigerant piping Network work
MANDEV / MAXFLOW/RAJKO/TOTALINE / N/A
7411
30 Mtr
1,652
49,560
Condensate Drain Piping system work
PRINCE/FINOLEX/SUPREME/ASHIRVAD / N/A
3917
30 Mtr
352.82
10,584.6
Control and Transmission Cabling work
Polycab/ Finolex/ Havells/ RR Cable / N/A
8544
40 Mtr
201.78
8,071.2
Supply and fixing of MS stand
JINDAL/ TATA / N/A
7206
2 Each
3,528
7,056
Documents Required
9 documents required · 9 mandatory
RequiredExperience Criteria
RequiredPast Performance
RequiredBidder Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover
RequiredAdditional Doc 1 (Requested in ATC)
RequiredAdditional Doc 2 (Requested in ATC)
RequiredCompliance of BoQ specification and supporting document
Eligibility Criteria
Experience
3 yrs
Min Turnover
₹3
Past Performance
80%
Purchase Preferences
MSE Purchase Preference
Fee & Financial Details
EMD Fee Amount
Exempted
Important Dates
Last Activity
26 Nov 2024
Published
22 Aug 2024
Bid Opening
12 Sept 2024
Bill of Quantities
Item Wise
GeM BOQ Items (6 items)
Item No
Item Title
Description
Qty
Unit
Consignee
Delivery (days)
Spec
1
Supply of 3 TR indoor unit and 4 HP VRF outdoor unit
Supply of VRF Machine.
Supply of VRF Outdoor Unit Supply of factory data built and tested side discharge modular type Variable Refrigent Flow Air Conditioning outdoor Unit complete with Air cooled Inverter control variable multiple scroll compressor of R 410 Refrigent and suitable to operate on 385 to 420 V 50Hz 3 ph power supply having stepless modulation low noise inverter based suitable step speed control condensor fans micro processor based centralized control panel for communicate individual remote controler sequential starting of condensing unit auto check function for connection error multi row heat exchanger with factory coated hydrophilic retreated aluminium fins for heat corrosion The unit shall also have an oil accumulator solenoid valves expansion valves and other control accessories. The unit shall also be provided with mounting frame duly painted and other standard accessories. The condensing units should be capable for outside ambient temperature 56 degree C as per tender specification and as per direction of engineer in charge. Capacities and type of outdoor and indoor units shall be as follows
a.4 HP Side discharge VRF outdoor.
b.Supply of VRF indoor Unit Supply of factory assembled and tested VRF indoor unit with multi speed fan motor Dx Cooling Coil etc as requirement as per site condition.
3.0 TR Ceilling Mounted Type VRF Compatible indoor unit VFC 36.
c.Supply of cordless remote controllers for indoor unit.
2
Job
Laxmidhar Jena Installation Of Indoor And
751020,O/O Airport Director, AIRPORTS AUTHORITY OF INDIA, B.P.I.AIRPORT, Admin building, BHUBANESW AR- 751020 Outdoor Of VR F Machine
90
-
2
Installation of Indoor and outdoor of VRF Machine
Installation of VRF Machine
a.Installation of VRF Outdoor Unit Lifting Shifting Erection Installation Testing and commissioning Variable Refrigerant Flow modular type Air conditioning Outdoor units including necessary anti vibration mounts necessary refrigerant and electrical cabling work nitrogent flushing etc. as required as per site condition as per tender specification and as per direction of engineer in charge
b.Installation of VRF Indoor Units Lifting Shifting Erection Installation Testing and Commissioning of factory assembled and tested VRF In Door Unit including necessary anti vibration mounts necessary hanger supports as per site condition. Electrical cabling connection communication cable address setting nitrogen flushing etc. as per manuefactures standard specification.
c.Installation of VRF indoor cordless remote controllers and Y joints etc as per site requirements.
d.GAS Charging and Commissioning of VRF System Testing and Commissioning of all above VRF units including topping of environmental friendly R410A gas as per site requirements after system leak test and 24 hours nitrogen pressure hold and necessory electric connection etc as require in all respect
2
Job
Laxmidhar Jena Refrigerant
751020,O/O Airport Director, AIRPORTS AUTHORITY OF INDIA, B.P.I.AIRPORT, Admin building, BHUBANESW AR- Piping Network Work
90
3
VRF System Refrigerant piping Network work
VRF System Refrigerant piping Network
Supply installation testing and commissioning of minimum 18 or 20 gauge copper Interconnecting Refrigerant piping work in between each indoor unit and outdoor unit complete with necessary fittings bend reducer socket etc. as require according to approved piping layout drawing. Entire refrigerant pipe line shall be 3 insulated with 13mm or 19mm thick closed cell elastomeric nitrile rubber tubular insulation as per specifications. All indoor refrigerant header pipes shall run through ceiling with G.l hanger supports at an interval not exceeding 1.5meter with necessary clamps tie belt etc as per site requirement and as per tender specification and as per direction of engineer in charge.
a.Suction and Discharge Refrigerant cupper pipe with nitrle rubber insullation.
b.Supply and fixing of 4Cx2.5sqmm pvc insulated round copper flexible cable.
30
Mtr
Laxmidhar Jena Condensate Drain Piping System
751020,O/O Airport Director, AIRPORTS AUTHORITY OF INDIA, B.P.I.AIRPORT, Admin building, BHUBANESW AR- 751020 Work
90
4
Condensate Drain Piping system work
Condensate Drain Piping
Supply and Installation of floor wise Condensate Drain piping with min PVC header pipes ISI marked with all necessary fittings and supporting arrangement duly insulated with 9 mm thick tubular elastomeric nitrile rubber insualtion. Braded flexible elastomeric nitrile rubbe insulated pipes can be used from indoor unit drain nipple to rigid CPVC or UPVC Draiun header line Connecting pipe sizes from indoor unit to drain header shall be same as drip pan drain outlet nipple size.
a.19.05 or 25.4mm NB rigid PVC pipe with insulation.
30
Mtr
Laxmidhar Jena Control And Transmission
751020,O/O Airport Director, AIRPORTS AUTHORITY OF INDIA, B.P.I.AIRPORT, Admin building, BHUBANESW AR- 751020 Cabling Work
90
-
5
Control and Transmission Cabling work
Control and Transmission Cabling
Supply laying and wiring of control cum transmission cabling work along with PVC conduit for looping between VRF indoor units to main central remote controller device of VRF outdoor unit with suitable clamp socket etc.transmission cable may run with respective inte connecting refrigerant pipe line.
40
Mtr
Laxmidhar Jena
751020,O/O Airport Director, AIRPORTS AUTHORITY OF INDIA, B.P.I.AIRPORT, Admin building, BHUBANESW AR- 751020
90
6
Supply and fixing of MS stand
Supply and fixing of MS stand duly painted with enamel paint for outdoor unit as per tender specification and as per direction of engineer in charge.
2
Each
Laxmidhar Jena
751020,O/O Airport Director, AIRPORTS AUTHORITY OF INDIA, B.P.I.AIRPORT, Admin building, BHUBANESW AR- 751020
90
Stage Documents
Award of Contract
contract_GEMC-511687795199584.pdf
GEM_CONTRACT • 0.09 MB
Documents
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .