Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-Finance | L1 | Accepted-Finance Valid documents received and accepted | |
| 2 | L2₹31.5 L+₹83,768.94 (2.73%)Accepted-Finance | L2 | Accepted-Finance Valid documents received and accepted | |
| 3 | L3₹32.0 L+₹1.4 L (4.43%)Accepted-Finance | L3 | Accepted-Finance Valid documents received and accepted |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Oct 2023, 6:00 pmClosed
Shri Sagar Maheshwari, IDSE
GE (AFA) Hyderabad PIN-500043
Provn of certain work services at FOL store, Interlocking path tiles around hose ramp at ATS and Addn/Altn at Safety Bay and certain Minor Works at AFA HYDERABAD
2023_MES_620772_1
8382/E8
Open Tender
Civil Works
Item Rate
120 days
GE (AFA) Hyderabad
As per tender pages
4 documents required · 4 mandatory
₹500
GE (AFA) Hyderabad
₹70,000
Yes
28 Oct 2023
27 Sept 2023
27 Oct 2023
27 Sept 2023
25 Oct 2023
12 Oct 2023
27 Sept 2023 - 10 Oct 2023
Amount
M&L for roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove dust, etc. complete all as specified and as directed.
M & L for coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.18sqm but n.exc 0.38 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge.
M &L for Glazed ceramic coloured tiles in vertical surfaces of dado, skirting etc 600X300x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including backing coat/ plastering 10 mm thick in cement mortar 1:4 complete all as specified and as directed.
M&L Granite (of any type) tiles as in floors 18 to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over and including15mm thick cement mortar(1:4) screed bed complete all as specified and as directed.
Rounding to edges of stone slabs to one edge, such as in steps, cooking platform and other similar situations all as specified and as directed by Engr-in-charge
Dismantling boarding, any description, fixed in any position fixed with screws and framed work complete all as specified and as directed by Engr-in-charge
Demolition of brick work/ PCC Block or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removing unserviceable debris to a distance exc 1.5 km but nexc 3 km complete all as directed by Engr-in-Charge.
M& L for Pre-cast cement concrete block masonry type C1 (1:3:6) (using 20 mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4, as in walls/ lining to the edges of interlocking tiles etc complete all as specified and as directed.
M&L for Precast reinforced cement concrete type(1:2:4) B-1, using 20 mm graded aggregate as in shelves set in cement mortar 1:6 complete all as specified and directed. Note Reinforcement will b e measured seperately
M & L for Mild steel TMT bars 6 mm to 8mm dia ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in CM (1:6) finished even and smooth without using extra cement complete all as specified.
M & L for preparing new plastered or unplastered surfaces of walls including cornices and applying two coats of cement base paint over a coat of primer complete all as specified and as directed .
Taking down shutters including frame of any description exc 1 sqm but n.exc 2 sqm each all as specified and as directed .
S&F Framed M.S work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed by Engr-in-Charge.
M&L for Preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M& L for Plain Cement concrete 1:4:8 Type D2 (using 40 mm graded stone Aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for and removing debris to a distance exc 1.5 km and n.exc 3 km complete all as specified and as directed. .
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter including fair finished surfaces complete all as specified and as directed.
M&L for Reinforced Cement Concrete M-25 (Design Mix) (20 mm graded stone aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete Complete all as specified and as directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.to a fair finished surface complete all as specified and as directed.
M&L for Reinforced Cement Concrete M-25 (Design Mix) (20 mm graded stone aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified
M&L for Formwork to Challah hoods, chajjas, troughs and similar items including edges to a fair finished surface complete all as specified and as directed.
M&L for Reinforced Cement Concrete M-25 (Design Mix) (20 mm graded aggregate) as in chajjas complete all as specified
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per item No.28 above but 6mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed
M & L for Vitrified ceramic tiles of any shade 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed or bedding layer in cement mortar (1:4) 15mm thick complete all as specified.
M & Lfor suspended false ceiling system using Armstrong sections ceiling grid system of grid size 600 x 600 mm including 14mm thick Armstrong ceiling board placed over grid and the entire system of grid shall be suspended from roof with 2mm dia GI wire accordingly to the roof height with dash fastner/rag bolts etc as per manufacturer instruction incl taking down old false ceiling complete all as specified and as directed by Engr-in-charge
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of synthetic enamel paint over a coat of white primer complete all as specified and as directed.
Taking down chowkats or frames with shutters exc 1.5 sqm but n.exc 4 sqm each (without taking off shutters from the frame) complete all as directed.
Taking down chowkats or frames with shutters n exc 1.5 Sqm each (without taking off shutters from the frame) complete all as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out of Hard/dense soil complete all as specified and as directed.
Removing excavated soil to a distance exc. 1.50 km but n exc. 5 km and depositing where directed at a level n exc 1.5m above the starting pointall as specified and as directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100mm thick Cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in sub base flooring complete all as specified and directed by Engineer in charge
S&F Pre polished Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade complete laid dry using machine compaction over and including 40mm thick (average) sand cushioning complete all as specified and directed by Engineer in charge.
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard/Dense Soil complete all as specified and directed.
M&L for Plain Cement Concrete(1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping to the edges of interlocking tiles including necessary form work complete all as specified and as directed.
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement complete all as specified.
S&F of Structural Steel work as in columns, posts, stanchions etc using ERW or induction butt welded tubes conforming to IS-1161-1998 grade St.-240 or with holow structural steel sections conforming to IS 4923-1997 Grade St-240 all as specified and directed.
S&F of Structural Steel work as in main and cross beams, hip and jack rafters, purlins where connected to common rafters , vertical posts, etc fixed with angle cleats or other connecting plates, cleats etc. using ERW or induction butt welded tubes conforming to IS-1161-1998 grade St.-240 or with hollow structural steel sections conforming to IS 4923-1997 Grade St-240 all as specified and directed.
S&F Pre painted galvalume aluminium zinc coating GI based corrugated sheet 0.5mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall with self tapping screws complete all as specified and as directed.
S&F Mild Steel work as in wind ties for roof including securing bolts or with screws complete all as specified and directed.
S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as per specified and as directed by Engineer-in-Charge. (Note-weight of aluminiun material will be considered for payment purposed.)
S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making openabled/sliding/fixed for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket and necessary Builder hardwares required for functioning etc, with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make , fixing with dash fasteners of required dia and size, including necessary fittings, stays, locking arrangement, rooler etc filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as per specified and as directed by Engineer-in-Charge. (Note-weight of aluminiun material will be considered for payment purposed.)
S & F 12mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination in aluminium doors/partition complete all as specified and directed
S & F for 5.50 mm thick sheet glass, ordinary quality and glazing in aluminium door frames with beading not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S & F 10mm thickToughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required all as specified and as directed..
S & F door closer, hydraulically regulated, aluminium body designation No 2 universal type (ISI marked), suitable for shutters of weight between 36 to 60 Kg complete all as specified and as directed.
S&F floor door stopper of aluminium alloy body & tongue, anodised with hard drawn spring of 140mm size fixed in floor complete all as specified and directed
S & F solid PVC Wall Lining consisting of 5mm thickplain colour PVC sheet on and including PVC frame inclusive of solvent cement and necessory joining beading and other fittings and fixing at site all as per manufacturers specifications and directions all as directed.
Supply and fixing of Armstrong false Ceiling Classic Lite 600x600x16mm, NRC-0.55,including grid of size main tee 32x24mm @1200 c/c cross Tee of 1200mm of size 27x24 mm and cross Tee of 600mm of size 25x24 mm and wall angle of size 19x19mm and fixed all around the wall to form a grid of size 600x600. Tiles shall be inserted in the formed grid and suspended with 2mm GI wire at every 1200mm intervals C/C all as per manufacturer specifications and directions and as directed.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified and as directed.
M&L PCC (1:2:4) type B1 (using 20mm graded stone aggregate) 100mm thick, as in Floors, finished fair and even complete all as specified & directed by Engineer-in-Charge.
M&L for RCC (design mix M-25 using 20mm graded stone aggregate) as in slab supported on wall, beams and columns in floors roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.
Formwork to soffits of suspended slabs such as roof labs, floor slabs, landings and similar work; not exceeding 200mm thick for flat surface all as specified and as Engr in charge.
M&L for rendering 5mm thick in CM 1:3 on concrete surfaces of ceiling , finishing the surface even and smooth without using extra cement all as specified and as directed.
M&L for preparation of newly plastered wall surfaces and applying 3mm (average) thick wall care putty and applying two coat of oil emulsion distemper over one coat of primer complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceilings and applying two coat of oil emulsion distemper over one coat primer including filling of cracks, holes etc. with cement putty complete all as specified and directed.
Returning, filling in soil incl spreading, levelling watering and well ramming in layers n.exc .25cm thickness all as directed .
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc.1.50m above the starting point all as specified and as directed.
S&F mild steel sheet 1.0mm thick for covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc, with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. all as specified and as directed.
S&F in butt hinges extruded aluminium alloy with galvanized mild steel hinge pin ,anodized of hinges 100 mm type B-21 all as specified and as directed.
S&F Mild steel pressed handles, oval type, stove enamelled black 150mm size all as specified and as directed.
S&F Mild steel sliding door bolts 300mm plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed all as specified and as directed.
M&L for PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) 50mm thick as in plinth protection, finished even and smooth finishing without using extra cement complete all as specified and as directed.
M&L rendering 15mm thick in CM (1:4) mixed with WPC, finishing the surface even and smooth without using extra cement on RCC surfaces of roof when concrete is still green including applying cement slurry at honey consistency all as specified and as directed. Note:- Supply of WPC shall be measured and paid separately under respective item.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for RCC (design mix M-25 using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc complete all as specified.
M&L for Use and removal of form work to side of pillars, posts, struts, piers, columns and stanchions beam and similar work for flat surfaces all as specified.
M & L Sand covering /cushioning for underground cable protection complete all as specified in SSR Part- I and directed by Engr- in Charge. Note: Punned thickness shall be measured.
M&L for burnt bricks sub class 'B' laid perpendicular over & cushioning for cable protection complete all as specified & directed at site by the Engr- in Charge.
Supply and lay LT UG cable, XLPE insulated armoured, heavy duty aluminium conductor multistranded, 1100volts grade, of 10Sqmm x 2core cross sectional area laid in trenches / fixing on walls / poles or passing through GI pipe including connecting up with suaitable lugs, nuts and bolts wherever required and testing complete all as specified.
M&L for Dismantling,shifting and refixing of split type AC of any make & model from one location to another location at AFA and refixing the AC with gutties/fasteners, core cutting in brick wall/concrete incl arrangement of required T&P, laying of extra insulated copper tubing, positioning of condensing unit and brazing work, leak check, dehydration and topping up of refrigerant gas upto recommended level, connection of drain pipe, making good the disturbed surface including making good the PCC and brick work and testing the unit for satisfactory functioning complete all as specified and directed. Note :- Refrigerant,copper tube and Copper cable if required to be charged, shall be measured and paid separately under relevant item mentioned here-in-under.
Supply and topping up/charging of refrigerent gas (R-22/R-410A/R-32) for ACs as per standard practice all as specified and directed.
S&F in replacement copper tubing flexible of dia 5/8" including heavy duty nitrile rubber insulation complete all as specified and directed by Engineer-in-charge
All as per item 77 but of dia 3/8" all as specified and as directed
All as per item 77 but of dia 1/2" all as specified and as directed
Supply and lay PVC insulated 3 core round flexible copper cable 1100 v grade of size 2.5 sq mm all as specified and as directed. Make:- Plaza/Polycab/Havells/Finolex
Taking down existing Industrial box (AC box) and refixing the same all as specified and as redirected
Taking down existing SPN DB Box and refixing the same all as specified and as redirected
M & L for Point wiring with 1.5 Sqmm copper conductor unsheathed, multistranded, PVC insulated, single core cable FRLS with earth continuity conductor of 1.5 sqmm PVC insulated copper conductor including rigid PVC conduit of suitable size but not less than 20mm dia or PVC Casing and Caping as required at site and all accessories fixed to the surface of the roof/ walls etc., including terminal boxes made out of MS sheet of thickness not lessthan 1.6mm thick for fixing of switches, fan regulators socket outlet etc along-with 3mm thick top laminated bakelite sheet for housing switches, etc complete for light/ fan/ socket point all as specified and as directed.
S&F switch piano flush type, 5 Amps, single pole one way all as specified and as redirected.
M & L for Point wiring with 1.5 Sqmm copper conductor unsheathed, multistranded, PVC insulated, single core cable FRLS with earth continuity conductor of 1.5 sqmm PVC insulated copper conductor and including rigid PVC concealed conduit of suitable size but not less than 20mm dia. and all accessories consealed in wall & surface of the roof etc., including modular type terminal boxes made out of Galvanised sheet of thickness not less than 0.9mm thick for fixing of modular switches, modular fan regulators, modular socket outlet etc along-with suitable modular plate for housing switches, etc complete all as specified and as directed for:-.
(a) One light point controlled by one switch
(b) One three pin socket 5 Amps plug point independent board
(c) One three pin socket 5 Amps plug point on same board
All as per Ser item No85 above but with 2.5 sqmm copper cable in and including PVC conduit complete all as specified and as directed for 15A socket.
S&F of Modular Switch type polycorbonate white 1 way, 6A, 240Volts complete all as specified.
S&F of Modular Switch type polycorbonate white 1 way, 16A, 240Volts complete all as specified.
S & F modular Switch socket outlet 3 pin 5 amp' flush type, 240Volts complete all as specified.
S&F of Modular Socket outlet polycorbonate white 10A - 2/3 pin complete all as specified.
S&F of Modular Socket outlet polycorbonate white 20A - 2/3 pin complete all as specified.
S&F surface mounting/wall mounted LED tube light fitting 1x20/18watts high efficiency, anti glare, maintenance free operation including LED driver and mounting arrangements, all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour with suitable size including taking out old unserviceable one complete all as specified and directed by Engineer-in-Charge.
S&F of 1X36 to 40W high efficiency 2'X2' recess mounting LED light fitting with glare free homogeneous illumination including LED driver with all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable complete all as specified and directed by Engineer-in-Charge.
Supply and install hi wall split air conditioner units Inverted type of capacity 1.5 TR indoor/outdoor with copper condenser units complete with cordless remote control unit and with inbuilt air ioniser and plasma filter to better indoor air quality with minimum 5 star rating all as specified and directed
S&F Voltage stabilizer for automatic operation single phase air cooled indoor type & designed input variation between 130 V to 300 V with output voltage stabilizer at 230 volts with accuracy of +/- 2.5 and of capacity 4 KVA all as specified and directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps capacity complete all as specified and as directed.
S&F single phase modular type motor starter 32 A, 240 Volts, 50 Hz for split AC including cover plate and PVC surface box of suitable size complete all as specified and as directed.
S&F of 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP 40 to 100 Amps current carrying capacity and connectingup, testing and commissioning.. complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core all as specified and directed
M&L for Tubes, 'light grade' galvanised 40mm dia, with all fitting such as socket, elbow, bend and clamps etc and fixed complete to walls and ceilings or laid in floors/trenches/pole complete all as specified and directed.
S & F DB with sheet metal enclosure 240 volts, 4 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete. Distribution Board shall be fitted out side of the explosive store complete all as directed.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6.6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 15mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing. Note: (i) Cost of GI strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling , removing , PCC chamber pit, RCC cover, test point etc.
Taking down carefully un serviceable point wiring of light points, fan, socket out let on TW battens/PVC pipes/casing & caping including material like sockets, switches, ceiling roses, regulators, light fittings etc and removing the materials from site and making good the disturbed portion of walls/floors ceiling etc complete all as specified and as directed.
Taking down ceiling fan of any Sweep and Make by disconnecting Electric Connection , removing ceiling fan and hand over to MES STORE YARD OF AGE E/M (AFA) Hyderabad for re-use complete all as specified and as directed.
Taking down unserviceable submain wiring any size complete all as specified and directed.
Taking down unserviceable MCBs, DBs, Main switches complete all as specified and directed.
M&L for Point wiring complete with 1.5 sqmm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through and including stove enamelled steel conduit and conduit accessories ISI marked fixed on wall / ceiling/ roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc, complete all as specified Note : The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
(a) One light point controlled by one switch
(b) One exhuast fan or wall mounted Fan controlled by one switch
S & F of Flame proof rotary type switch with termination box in LM6, 16A, single pole 250 V complete all as directed
S&F of ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
M&L for Sub Main wiring with two runs of 6 sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor cable drawn through and including medium grade, rigid non-metallic or PVC casing caping of suitable size with all necessary fittings, in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete complete all as specified and directed by Engineer-in-Charge. Note :- (i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iii) Three runs of 6 sqmm catle and one run of PVC casing caping will be measured as one length
S & F DB with sheet metal enclosure 240 volts, 8 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete. Distribution Board shall be fitted out side of the explosive store complete all as directed.
S&F MCB SPN 6 to 32A, 10KA rupturing capacity complete all as specified and as directed.
S&F Fix MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
S&F of flame proof LED tube light fitting 1x16 to 20W , 230 V including integral reflector made of aluminium alloy LM 6, with all connected accessories and all accessories pre-wired, connecting up with FRLS flexible copper conductor with suitable size all as specified and directed.
S& F of exhaust fan flame proof, AC single phase, 230/240 V of size 380 (15'') mm sweep with louvers 1440 RPM including making necessary opening on stone /brick masonry wall and making good the disturbed surfaces to match with existing finish including surroundings all as directed.
M&L for dismantling existing duct of any shape along with Air vents/grills/shutters achoring material complete including making good disturbed surface all as specified and directed.
M&L closing the existing duct entry of wall with GI sheet 22 gauge including necessary angle iron, cleat,carriage bolt, gasket and sealent as per site requirement complete all as specified and directed. Note- Cost of materials requried is deemed to be included in quoted.
Supply , installation, testing and commissioning of Intelligent Addressable microprocessor based single loop fire alarm control panel with one loop card, capable of handling 99 detectors and 99 devices on a 75% maximum loading with suitable battery backup for 72 hours in normal condition and 3 hours during alarm condition and shall be expandable 2 loop capacity. The panel shall also have networking capacity via RS 485. The panel shall be provided with dedicated earthing which has to be connected to the existing earthing line of the building. The panel shall also be provided with separate battery stand and the same shall be mounted next to the pane. The tenderer shall need to provide the battery calculations. The system shall also have the provision to have an auto dialer attached to this panel which shall be having speech processor for sending out recorded information. complete all as specified and directed.
Supply, installation, testing and commissioning of Intelligent Addressable multisensor type Heat & Smoke detectors with bases all as specified and as directed.
Supply, installation , testing and commissioning of Response Indicator for multisensor type heat and smoke detector.
Supply, installation , testing and commissioning of Intelligent addressable sounders with strobe inbuilt each sounder shall meet the specifications all as specified and as directed.
Supply, installation , testing and commissioning of 3 x 3 metal junction box for mounting of detectors with metal glands and gasket. The height of the junction box shall be not more than 60mm in height and shall be sturdy all as specified and as directed.
S&F of 25mm dia PVC conduit of FRLS grade RED in colour fixed on walls, ceiling, floors etc all as specified and as directed
Supply, installation , testing and commissioning of Intelligent addressable control module for floor wise operation of sounder cum strobe. The module shall monitor the cable and the power to the sounders all as specified and as directed.
Suppy & Fixing unarmoured shield cable (single core) in FRLS 2 core x 1.5sqmm complete all as specified and as directed.
Supply, installation , testing addressable manual call point resettable type complete all as specified and as directed.
M/S NAVEEN BUILDERS
S J REDDY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .