Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.1 LAccepted-Finance | L1 | Accepted-Finance Lowest One | |
| 2 | L2₹1.0 Cr+₹5.7 L (5.80%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹1.1 Cr+₹10.3 L (10.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹1.2 Cr+₹23.5 L (24.0%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹1.4 Cr+₹45.7 L (46.5%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹2.5 L
Closing Date
8 Jun 2023, 6:00 pmClosed
GE NW NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
REPAIR REPLACEMENT OF HT CABLES REPAIRS TO CAPACITORS AND OVERHAULING CALIBRATION FILTRATION OF HT EQUIPMENTS AND REPAIRS AND MAINTENANCE OF DG SETS AND OTHER CERTAIN MAINT WORK AT VARIOUS LOCATIONS AT NOFRA AREA UNDER GE NW NOFRA COLABA MUMBAI
2023_MES_595301_1
8175
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
Yes
GE NW NOFRA
₹2.5 L
Yes
13 Jun 2023
13 May 2023
10 Jun 2023
13 May 2023
8 Jun 2023
25 May 2023
13 May 2023 - 18 May 2023
Amount
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type OCB trolly of rupturing capacity 250 MVA, 400 Amps from location and repair /overhauling and carrying out with the following activities as mentioned below complete all as specified and directed by Engineer-in-Charge. (Note: spare parts and new transformer oil shall be measured & paid seperatly) .
(i) Inspecting/overhauling of spring drive mechanism by checking mechanism, hold on catch assembly,trip bridge, z srew, Cam U, Aluminum trip bridge, Main trip lever assembly and apply multi grease lubricant to function smoothly.
(ii) Inspecting / overhauling of OLTLF assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.
(iii) Inspecting / overhauling / cleaning and inspecting insulators, moving contacts ,fixed contacts,arcing chamber by carbon cleaner solution and apply dry graphite conductive sealant for contacts to avoid carbon deposits on contact surfaces.
(iv) Inspecting/Cleaning of oil tank inside and out side surface by CRC throughly and replacement of transformer oil (60 litre for each OCB) and apply heavy duty grease for tank raising/lowering guide. Note: Transformer Oil will be measured and paid seperately.
(v) Assembling all items/components parts to the respective position & testing the breaker with High Voltage and Meggering before and after high voltage test complete.
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350 MVA, 400/630/800 Amps from location and repair /overhauling and carrying out with the following activities as mentioned below complete all as specified and directed by Engineer-in-Charge. (Note: spare parts will be measured & paid seperately.)
(i) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.
(ii) Inspecting / overhauling of tripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.
(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptors by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.
(iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete.
Repair /Servcing to Load Break Swirch,Capacity 11 KV 25kA / 1min rupturing, 630 Amps and carrying out the following activities as mentioned below complete all as specified and directed by Engineer-in-Charge. (Note: spare parts will be measured & paid seperately.)
i) Inspecting/overhauling of spring assissted drive mechanism by checking mechanism forged contacts, trip lever assembly and apply electrical grade lubricant to function smoothly.
(ii) Inspecting / overhauling of HRC fuses and fuse carrier assembly.
(iii) Inspecting / overhauling / cleaning and inspecting insulators, moving contacts ,fixed contacts,arcing quenching chamber by carbon cleaner solution.
(iv) Inspecting/Cleaning of Epoxy insulators.
(v) Assembling all items/components parts to the respective position & testing the breaker with High Voltage and Meggering before and after high voltage test complete.
Repair/Overhauling Indoor type, 11 KV, SF 6,RMU Panel and carrying with following and all as specified and directed by engineer in Charge. Note :- (i) Including fixing of spare parts to function RMU smoothly and rate to be included. (ii) Spare parts and SF6 Gas will be measured and paid separatly.
Notes :- (i) Inspecting/overhauling of Manual/motorised spring drive mechanism by checking mechanism, Motor and gear assembly, Big gear assembly, stop bolt assembly, Main shaft interlocking assembly, closing spring assembly, Small Cam with screw, motor cut -off limit switch, Butter fly switch assembly and apply multi grease lubricant to function smoothly.
ii)Inspecting / overhauling of assembly, earth fault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.
(iii)Inspecting / overhauling /cleaning and inspecting insulators, Gas Chamber by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.
(iv) Inspecting of Gas SF6 leakage and Re filling SF6 gas as required and all as directed.
(v) Overhauling/testing of Metering Panel with PT
(vi) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete.
(vii) Cleaning all busbar by rubbing and by CRC liquid cleaner.
(viii)Spraying two coat of anti track paint on CTs.
(ix) Applying insulating boots for busbar and cables.
(x) Supply and fixing all missing nut bolts for panels.
Material and labour of Opening the bus -bar chamber,CT chamber, PT Chamber and Meter chamber of HT 11KV, panel board and carry out following activities as mentioned below complete all as directed and specified by Engineer-in-Charge. (Note: spare parts shall be measured & paid seperately.) :-
(i) Inspecting/cleaning/overhauling of bus bar chamber by checking of bus bars, spout insulators, space heaters and removing dust with vacuum cleaner/Blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying STRIPPEX(A), STRIPPEX(B) and HT tape and test with High Voltage(DC) and meggering before and after high voltage test complete.
(ii) Inspecting/cleaning/overhauling of CT/PT chamber by checking of Bus bars, spout insulators, space heaters and checking of wiring system and removing dust with vacuum cleaner/blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying anti tracking paint on CT's and insulators and HT Tape.
Material and labour for Testing /Overhauling and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete.
Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts AC and replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts and oil will be measured and paid seperately)
Material & Labour for Dy hydration/fltration of Transformer oil including testing of dielectric strength of transformer oil of indoor type transformer, 11KV/433 volt, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete as specified. (Note: Transformer oil will be measured & paid seperately.)
Material & Labour for Removing old burnt Transformer oil and Supply and toping of transformer oil with 50KV di-electric strength complete all as specified. Make: Power /Asian/Savita/Electric.
M&L for Dismantling of Damaged Breather and Supply and fixing in repair of breather with 1000 Grams celica gel suitable for indoor type transformer all as specified and directed by Engineer-in-Charge.
M&L for Dismantling of Damaged thermometer and Supply and fixing in repair of thermometer(oil temperature gauge)suitable for indoor type transformer, all as specified and directed by Engineer -in -Charge.
Material and labour for Spray Painting of Transformer of following capacity,indoor type with Two coats of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities complete and all as specified and directed by Engineer-in-charge.
Transformer 500KVA ,11KV/433Volt
Transformer 300 to 400KVA ,11KV/433Volt
Transformer 160 to 250KVA ,11KV/433Volt.
Material and labour for Servicing/Repairing of Transformer by disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of LT bushing / HT bushing including necessary tools to attending leakage problem with new oil seal and all gaskets and re assembling complete all as specified and directed. (Note : New Transformer oil and spare parts will be measured and paid separatley excluding oil seal)
Transformer 500KVA ,11KV/433Volt
Transformer 300 to 400KVA ,11KV/433Volt
Transformer 160 to 250KVA ,11KV/433Volt.
Material and labour for replacing Burnt out Studs with nuts of any material by providing new copper alloy stud with nut,washers on HT Side complete all as specified and directed for following capacity transformers:-
Transformer 500KVA ,11KV/433Volt
Transformer 300 to 400KVA ,11KV/433Volt
Transformer 160 to 250KVA ,11KV/433Volt.
Material and labour for replacing damaged Bushing with new bushing on HT Side complete all as specified and directed for following capacity transformers:-
Transformer 500KVA ,11KV/433Volt
Transformer 300 to 400KVA ,11KV/433Volt
Transformer 160 to 250KVA ,11KV/433Volt.
Material and labour for replacing Burnt out Studs with nuts of any material by providing new copper alloy stud with nut,washers and bushing on LT Side complete all as specified and directed for following capacity transformers:-
Transformer 500KVA ,11KV/433Volt
Transformer 300 to 400KVA ,11KV/433Volt
Transformer 160 to 250KVA ,11KV/433Volt.
Material and labour for replacing damaged Bushing with new bushing on LT Side complete all as specified and directed for following capacity transformers:-
Transformer 500KVA ,11KV/433Volt
Transformer 300 to 400KVA ,11KV/433Volt
Transformer 160 to 250KVA ,11KV/433Volt.
Dismantling of old damaged Cooling Fins and upply and fix in repair cooling fins of transformer of capacity 400/500 KVA as per manufacturer's specifications and standard practice complete all as specified and directed.
Dismantlin of old damaged Cooling Fins and upply and fix in repair cooling fins of transformer of capacity 250/160 KVA as per manufacturer's specifications and standard practice complete all as specified and directed.
Dismantlin of old damaged Off Load Tap Changer and Supply and fix in repair Off Load Tap Changer of transformer of capacity 250/160 KVA as per manufacturer's specifications and standard practice complete all as specified and directed.
Dismantlin of old damaged Off Load Tap Changer and Supply and fix in repair Off Load Tap Changer of transformer of capacity 500/400KVA as per manufacturer's specifications and standard practice complete all as specified and directed.
Material and labour for loading into truck of faulty Transformer of capacity 250 KVA to 500 KVA with the help of Crain and shifting from site to factory premises and unloading complete all as specified and directed.
Material and labour for loading into truck of Transformer capacity 250KVA to 500KVA after carying out the repair with the help of Crain and shifting from factory premises to site and unloading and shifting it inside the sub station and connecting all HT and LT cable connections and earthing connections complete all as specified and directed.
Material and labour for Dismantling the Core and taking out along with windings and cleaning oil tank of transformer 250 to 500KVA, 11KV/415Volts and removing sludges from tank, and all as per manufacturers specifications and standard practice complete all as specified and directed. (Note: Transformer Oil will be measured and paid seperately).
Material and Labour for Dismantling the faulty HV winding carefully from transformer of any type and capacity11KV/433Volts from core and rewinding the HV winding with suitable size of insulated copper wire as per manufacturers specifications and standard practice complete all as specified and directed.
Material and Labour for Dismantling the faulty LV winding carefully from transformer of any type and capacity,11KV/433Volts from core and re winding the LV winding with suitable size of insulated copper wire and as per manufacturers specifications and standard practice complete all as specified and directed.
Material and labour for reinsulating the HV winding with DPC insulation and as per manufacturers specifications and standard practice complete all as specified and directed.
Material and labour for reinsulating the LV winding with DPC insulation and as per manufacturers specifications and standard practice complete all as specified and directed.
Material and labour for refixing the core and windings assembly with insulating material and hardware of Transformer of any capacity and type,11KV/433Volts in to the oil tank with suitable fixing arrangements and re connecting HV and LV internal connections to HV and LV bushings and replacing gaskets of bushings,bottom and top valve, top cover, conservator and replacing celica gel breather and fixing top cover with conservators and reassembling all parts respect to original position and refilling of new transformer oil and filler to achieve the BDV Values and testing as per manufacturers specifications and standard practice complete all as specified and directed. (Note: transformer oil will be measured & paid seperately)
Material and labour for painting of HT OCB capacity 250/350MVA,11KV, 400Amps, with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface and in side surface of OCB all as per specified and as directed by Engineer-in-charge.
Material and labour for painting of HT VCB capacity 250/350MVA,11KV, 400/630/800Amps, with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface and in side surface of OCB and all as specified and as directed by Engineer-in-charge.
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric panels Indoor type of each Transformer by taking shut down from appropiate authority including following activities
(i) Cleaning inside the panel and all incoming and out going feeders i.e incling MCCB/SFU/Changeover switches/Contactors/ ACB,s thoroughly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers. (iii) Replaceing the burnt out coluor coated PVC Sleeve of main and fedders bus with appropriated size of New PVC heat shrinkable sleeves -01Job. (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses.(Note: New items will be measured and paid separatly)-01Job. (v) Replacing burnt out contrle wiring of Ammeter/Voltmeter/Indicating lamps and CT'switch 2.5/1.5Sqmm copper sinhel core,1100V grade copper conductor cable- 01Job. (vi) Replacing Burnt out Bus Bar of incomming and out going feeders with appropriate size new bus bar (Copper/Aluminum) -01Job( Note : Bus Bar will measured and paid separately) (vii) Replacing Burnt out Insulators of incomming and out going feeders with appropriate size new Insulators -01Job( Note : Insulators will measured and paid separately)
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric FBB Out door type of each Transformer by taking shut down from appropiate authority including following activities (i) Tightning the loose connections and cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed . (Note: The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt ACB/ MCB/MCCB/Voltmeter /Ampermeter/CT/LED lamps of any type and discription etc and refixing the same,which shall be measured and paid as supply only under relevant items of this schedule.)
(i) Cleaning inside the panel and all incoming and out going feeders i.e incling MCCB/SFU/Changeover switches/Contactors/ ACB,s thoroughly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers (iii) Replaceing the burnt out coluor coated PVC Sleeve of main and fedders bus with appropriated size of New PVC heat shrinkable sleeves -01Job (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses.(Note: New items will be measured and paid separatly)-01Job (v) Replacing burnt out contrle wiring of Ammeter/Voltmeter/Indicating lamps and CT'switch 2.5/1.5Sqmm copper sinhel core,1100V grade copper conductor cable- 01Job (vi) Replacing Burnt out Bus Bar of incomming and out going feededs with approprieted size new bus bar (Copper/Aluminum) -01Job( Note : Bus Bar will measured and paid separately) (vii) Replacing Burnt out Insulators of incomming and out going feededs with approprieted size new Insulators -01Job( Note : Insulators will measured and paid separately) (viii) Re welding of Doors with new Injus
Supply & fixing Aluminium Bus Bar strips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed . Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Bolts, Nuts etc shall be measured and paid separately under respective items.
Supply & fixing Copper Bus Bar strip, of any size, for extention of MCCB terminals for cable terminations, inside the cable alleoy of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed . Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Bolts, Nuts etc shall be measured and paid separately under respective items.
Supply and fixing of suitable type and size FRP / DMC bus bar support insulator (Bridge Insulator) for fixing the extended aluminium bars, for cable terminations, duly fixed in the body of the panel board by and including galvanized steel bolts , nuts, washers etc.and necessary drillings, in the panel body,complete all as specified and as directed.
Material and labour for repairing of Capacitor (APFC ) panel of 100KVAR to 250KVAR and carryout repairs as (i)Dismantling of Power contactor,TP,415Volts and auxiulary contactors and cleaning,Overhauling,servicing ,repairing thoroughly and replacing burnt contactors upto 63Amps including suitable capacity of copper wire single core,1100Volts grade -01 Job (New contactors will be measured & paid separatly)
Supply & fixing power pack ,230V AC input, 30V DC /110Volt DC out put suitable for VCB/OCB 11 KV as power back complete all as specified and as directed. Make : Alan/Aditya/CG
Dismantling of Old Damaged/burnt spare parts from VCB and Supply and fixing in repair of following Spare parts suitable for - VCB 11 KV , 630/800 Amps indoor type of Make Schnieder(PIX -MV)/ABB(VD4) /CG/AREVA(VMX) all as specified and directed by Engineer-in-Charge.
Isolating Contacts flat type
Vaccum InterupterVG2
Insulating Rod
Closing coil 110V /24V DC
Tripping Coil 110V /24V DC
Spring Charging Motor 110V-230V AC/DC
Breaker Auxiliary Switch 6NO +6NC
Motor Cut-off switch
Main Drive Shaft assembly
Trip Fork Linkage Assembly
Rachet Wheel
Pin for Rachet
Handle Block Assembly
Closing coil assembly without coil
Trip coil assembly without coil
Motor cutt off Lever assembly
Trip Proper support assembly
Release lever
Pin for Release lever
Auxiary switch drive Assembly
Charging Pawl
Buffer for Spring
Over Rid Stop
Over Rid Stop Pin
24 Pin Plu and Socket Assembly
Bus Bar Spout Insulator with CC parts for R Phase
Bus Bar Spout Insulator with CCparts for Y Phase
Bus Bar Spout Insulator with CC parts for B Phase
Circuit Spout Insulator with CC Parts
3Phase Spout Insulator assembly Bus bar /Circuit side.
Half Collar (Pair)
Raising and lowering Handle
TNC Switch,16Amps Recom
Ammeter,digital type,DM3110 Schneider
Voltmeter,digital type DM3210 Schneider
Multifunction meter digital typeEM6400NG Schneider
Indicating Lamps24/110V DC LED type
Supply , fixing and testing commissioning for Relay Digital type 3 phase over current+ Earth fault Relay (MiCOM P111 Schneider) in existing VCB panel. Make: Schnieder/ABB/L & T/CG/ Siemens or equivalent make as approved by GE
Supply , fixing and testing commissioning for Relay Digital type 3 phase over current+ Earth fault Relay (MC61A L&T ) in existing VCB panel. Make: Schnieder/ABB/L & T/CG/ Siemens or equivalent make as approved by GE
Supply , fixing and testing commissioning for Self Powered Relay, Digital type 3 phase over current+ Earth fault Relay (7SR4501Siemens) in existing RMU panel. Make: Schnieder/ABB/L & T/CG/ Siemens or equivalent make as approved by GE
Supply , fixing and testing commissioning for Self Powered Relay, Digital type 3 phase over current+ Earth fault Relay (ADR241S Ashida)) in existing VCB panel. Make: Schnieder/ABB/L & T/CG/ Siemens or equivalent make as approved by GE
Potential Transformer,Single Phase,resin cast, indoor type, 11KV/110Volt/Rout3, 100VA burden Trolly mounted with HRC Fuse Make : Electrical Controls& Systems /NarayanaPower Tech /Pragati/ CG/ GeminiIntraTech /IEC/ MiniEngrs/ Kappaor equivalent make as approved by GE
Current Transformers, Resin cast,indoor type,Class1 and 5p10,15VA,18.3kA/3Sec. complete all as specified and directed by Engineer-in-Charge. Make : Electrical Controls& Systems /NarayanaPower Tech /Pragati/ CG/ GeminiIntraTech /IEC/ MiniEngrs/ Kappaor equivalent make as approved by GE
(i) 100-75/5+5Amps
(ii) 75-50/5+5Amps
(iii)50-30/5+5Amps
(iii)30-20/5+5Amps
HRC Fuse2Amps for Ptential Transformers 11KV/110Volt AC
Dismantling of old burnt Spout insulator and Supply and fixing of spout insulator assembly for HT OCB 11 KV , 400 amps indoor type with current carrying parts complete all as specified and directed by Engineer-in-Charge.
Dismantling of old burnt through insulator and Supply and fixing in repair of OCB through insulator assembly with current carrying parts for OCB, 11KV, 400Amps, indoor type and complete all as specified and directed.
Supply & fix electrical Insulating mat confirming to IS15652/2006 (superceding IS: 5424-1969) B.I.S+CPRI+NTH+ERDA approved of C class of mats dielectric strength 65KV, sheet thickness not less than 3.0MM using at power houses including pasting of rubber mats with adhesive resin all as specified and directed by Engineer-in-Charge. Make : Swastic /Jyoti
Dismantling of old burnt gasket and Supply and fixing in repair of OCB oil tank gasket 3mm thick suitable for OCB, 11KV, 400Amps, indoor type complete all as specified and directed.
Dismantling old burnt Heaters and Supply & fix in repairs strip type heater 80watt with control wiring suitable for indoor OCB/VCB,11 KV switch gear Panel board complete all as specified and directed by Engr-in-Charge.
Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed by Engineer-in-Charge.(Note : Spare parts will be measured and paid separately)
Dismantling of old damaged Lamps and Supply & fixing in repairs indicating lamp holder with bulb LED(Red Yellow,Blue,Green) type to indicate incoming supply suitable for 230Volts AC and all as specified and directed. Make:Teknic/ C&S /L&T
Material and labour for servicing of DG set of capacity 62.5 KVA to 125 KVA by carrying out the following maintenance including testing on completion for satisfactory performance for a period of 02 hrs. at connected load complete all as specified and as directed :- (Make: Greaves Ltd & Kirolskar) (Note: Spare parts,Engine Oil, Coolent will be measured and paid seperately as 'Supply only')
(a) Drain out of diesel from tank and storing in cleaned containers, cleaning the tank thoroughly by removing sediments settled at the bottom and refilling the drained out diesel duly filtered.
(b) Drain out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil upto required level
(c) Replacing suitable fuel filter stainer, fuel pipe, fuel filters, engine oil filter, air cleaner element and oil seal assembly complete.
(d) Check coolant level & top up the same if required
(e) Check and top up the electrolyte/distilled water in starting batteries to maintain the required specific gravity. Cleaning of battery terminals & applying petroleum jelly to battery poles & brass connectors.
(f) Checking and general adjustments of FIP, fuel injectors, governer, turbo charger etc for proper functioning of DG Set.
(g) Replacing suitable size of 'V' belts, hoses and clamps of air cleaner.
(h) Tightening all the fasteners of complete DG set to the required torque and cleaning the complete DG Set with suitable cleaning agent.
Supply only the following items suitable for DG set of capacity 62.5 KVA to 125 KVA.complete all as specified and directed by Engineer-in-Charge. Make: Greaves Ltd & Kirolskar or equivalent make as approved by GE
Fuel filters set (primary and micro filter)
Fuel pipes set (Fuel pump to filter and filter to feed pump)
Lub. oil filter
Air Filter element
V- Belts
Engine Oil 20W40
Coolent
Distild Water
Battery acid
Material & Labour for Repair/overhauling of dynamo including replacement carbon, brushes holder,spring,commutator/spring assembly bearing, regulator etc. of any make, type and capacity 62.5 to 125KVA complete all as specified and directed by Engineer In Charge.
Supply and fixing in replacement battery charger 24 Volts suitable for 12 volts 180 AH Battery complete all as specified and directed by Engineer In Charge.
Servicing/repairs of panel of DG set complete including cleaning resetting/adjustment of relays, calibration of time delay relays, checking and replacement if required of diodes,resistors electrical wiring etc. complete for any make type and capacity of DG sets complete all as specified and directed by Engineer In Charge.
Dismantling the Radiator assembly , flushing it complete, testing the radiator of water tightness,soldering the leakage spot, replace the loose radiator cap , rubber hose and re connect the radiator assembly to engine capacity 62,5KVA to 125KVA and testing complete all as specified and directed by Engineer In Charge.
Servicing of alternator including cleaning of field and armature winding, varnishing and baking polishing of slip rings, checking and making correct excitation system capacity 62.5KVA to 125KVA etc complete all as specified and directed by Engineer In Charge. for alternators of:-
Supply and replacing PVC insulated battery lead of25Sqmm size with copper conductor cable of length 1.5 mtr with copper/brass clamps and lugs for fixing on battery terminals and self starter complete all as specified and directed by Engineer In Charge.
Cleaning of the fuel tank of the following capacity DG sets after decaning the diesel, painting with one coat of approved colour synthetic enamel paint after thorough cleaning and preparation of surfaces, marking of fuel level gauge, fuel tank cap, writing of tank capacity 62.5KVA to 125KVA complete all as specified and directed by Engineer In Charge.
Supply and replacing battery stand made out of MS angle frame of size 600 mm x 250 mm x 300 mm with 40mm x 40 mm x 6 mm MS angle and wooden planks of size 75 mm all as directed by Engineer-in-charge.
Supply and replacing rectifiers for alternators suitable for Gen sets upto 62.5 KVA to 125KVA capacity complete all as specified and directed by Engineer In Charge.
Supply and fixing fuel level indicating pipe PVC 10 mm dia including fixing arrangements all as directed by Engr-in-charge.
Supply and replacing RPM meter suitable for 62.5KVA to 125KVA complete with cable and accessories at the last range 0 to 2500 complete all as specified and directed by Engineer In Charge.
Supply and replacing oil temp gauge 62.5 KVA to 125 KVA complete all as specified and directed by Engineer In Charge.
Supply and replacing oil pressure gauge62.5 KVA to 125 KVA complete all as specified and directed by Engineer In Charge.
Supply and replacing pressure safty control unit 62.5KVA 125 KVA complete all as specified and directed by Engineer In Charge.
Supply and replacing frequency meter anologue type at the rate 90mmx90mm square type complete all as specified and directed by Engineer In Charge.
Repair /reconditioning battery 12 volts 180 AH for holding charges for starting engine complete all as specified and testing and commisioning complete all as specified and directed by Engineer In Charge.
Supply and fixing Self starter suitable for 62.5KVA to 125 KVA DG Set complete all as specified and directed by Engineer In Charge.
Callibration of fuel injector with authorised agencies of 63 to 125 KVA DG Set complete all as specified and directed by Engineer In Charge.
Preparation of old painted surface of DG set capacity 62.5 KVA to 125KVA by removing all dirt, dust, grease, oil etc and painting by painting spray machine complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification Nos, capacity etc all as directed by Engineer-in-Charge for DG Set
Material & Labour for Repairing/Servicing of AMF panel of capacity 62.5KVA to 125KVA as under complete all as specified and directed by Engineer-in-Charge. :-
a)Checking of auto/manual functions and other logical functions of AMF panel including battery charging system,Lub oil pressure sytem,Engine start ,stop,over load etc..
d)Replacing of control wiring 1.5/2.5Sqmm copper cable
e)Replacement of Engine start relay 24Volt DC.
f)Replacing of PLA relay 3 C/O,240Volt AC.
g)Replacement of Sequency relay
h)Replacing of Hooter.
j) Replacing indicating lamps
l)Testing of the panel at site with functions of DG sets
Supply & Fix of Exhaust silencer suitable for Diesel Engine,capacity 62.5KVA to 125KVA all as specified and directed by Engineer-In-Charge.
Material & Labour for servicing of Self Starter 12/24VoltsDC from DG set,dismantling complete and replacement of solonide field coils,cleaning the cummutator strips including replacing the bearing,bends pinion re assembling,connecting and testing complete all as directed by Enginee-In-Charge
Repair / Servicing of unserviceable dynamo including cleaning of field and armature winding, varnishing and baking polishing of slip rings, checking and making correct excitation system etc. complete as specified and as directed for alternators of 100 KVA to 125 KVA complete all as specified and directed by Engineer In Charge.
Material & Labour for Top Over hauling of Engine of capacity 62.5 KVA to 125KVA KVA including of the followings complete all as specified and directed by Engineer-in-Charge. :-
i) Servicing of Head - 06 Nos
ii) Replacing of 'O' rings, springs, nut & bolts etc complete - 01 Set
iii) Replacement of inlet & outlet valve set incl overlaping etc - 04 Sets.
iv) Replacement of guide -08 Nos
v) Servicing and calibration of fuel pump - 01 Job
vi) Servicing and calibration of Injector 04 Nos by a authorised dealer- 01 Job
vii) Replacement of cylinder head gaskets set complete - 04 Sets
viii) Servicing of all piston 04 Nos and replacement of all type of rings-01 Job
Supply and fixing in replacement of unserviceable pre Lub Hyd lift pump VIC for 63/160 KVA and taking down the same complete all as specified and directed by Engineer In Charge.
Taking down the old unserviceable water body prior to taking down un screw the ,fan, fan belt, hose pipe and remove the its position and replacing with new water body as per sample complete all as specified and directed by Engineer In Charge.
Supply and replacement of AVAR for 100 to125 KVA DG set complete all as specified and directed by Engineer In Charge.
Material and labour for preparation of old plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer in and out side of installation complete all as specified and directed by Engineer In Charge.
Dismantlin the old damaged Relay and Supply only APFC Relay, 12Stages digital type suitable for 415V, 3phase, AC supply and all specified and directed. Make - L&T/ Syntron/Sycon
Dismantling the Old damaged Caoacitor Bank and Supply only Capacitor bank 5KVAR, Heavy duty type,415Volts,50Hz AC supply in existing panel complete as specified and directed by Engr-in-charge. (make: Prabodhan/Epcos/Havells/Schnieder
Ditto all as per item No.45 but of rating 10KVAR
Ditto all as per item No.45 but of rating 15KVAR
Ditto all as per item No.45 but of rating 20KVAR
Ditto all as per item No.45 but of rating 25KVAR
Dismantling of Old Damaged Contactor and Supply only Power contactors Capacitor Duty(Type MOC of L&T) 50Amps Capacitor duty with 2NO+2NC suitable for ,415Volts,50Hz AC supply in existing panel complete all as specified and directed by Engr-in-charge Make : L&T/C&S/Schnieder
Ditto all as per item No.50 but rating 40Amps
Ditto all as per item No.50 but rating 32Amps
Dismantling of old damaged MCB and Supply and fixing in repair of MCB,TP,C'Curve,63 Amps,415Volts,50Hz AC supply in existing panel with mounting rail complete all as specified and directed by Engr-in-charge.
Ditto all as per item No.53 but rating 40Amps
Ditto all as per item No.53 but rating 32Amps
Ditto all as per item No.53 but rating 20Amps
Dismantling of Old Damaged Contactor and Supply only Auxilaury contactors 10Amps Capacitor duty with 8NO+8NC suitable for ,415Volts,50Hz AC supply in existing panel complete all as specified and directed by Engr-in-charge Make : L&T/C&S/Schnieder/Havells
Dismantling of Old Damaged timer and Supply only Time delay Timer suitable for APFC panel ,415Volts,50Hz AC supply in existing panel complete all as specified and directed by Engr-in-charge Make : L&T/C&S/Schnieder/Havells
Dismantling of Old Damaged CT and Supply only Current Transformers,415V 600/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed. Make : AE/NSDA/MECO/C&S
Dismantling of Old Damaged CT and Supply only Current Transformers,415V 400/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed. Make : Make : AE/NSDA/MECO/C&S
Dismantling of Old Damaged CT and Supply only Current Transformers,415V 200/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed. Make : AE/NSDA/MECO/C&S
Material and labour for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Material labour for HT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 11KV grade complete with Jointing material (Heat shrinkable)and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mm and all as directed by Engineer-In-Charge.
Material labour for HT Cable Jointing work by Cutting the faulty cable and making END TERMINATION JOINT for 11KV grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 90 to 185 sq mm and all as directed by Engineer-In-Charge.
Supply and laying HT cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)11000 Volts grade with stranded aluminium conductor of size 185Sqmm 3 core and all as directed by Engineer-In-Charge.Make: Polycab/Havells/Nicco/Gloster
Material and labour for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 16 to 25 sq mm and all as directed by Engineer-In-Charge. Make: M Seal/Raychem/Denson
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 35 to 50 sq mm and all as directed by Engineer-In-Charge. Make: M Seal/Raychem/Denson
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 70 to 185 sq mm and all as directed by Engineer-In-Charge. Make: M Seal/Raychem/Denson
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 240 to 300 sq mm and all as directed by Engineer-In-Charge. Make: M Seal/Raychem/Denson
M&L for Cutting and removing of old faulty cable piece and Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 240Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells/Nicco/Gloster/Asian
M&L for Cutting and removing of old faulty cable piece and Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 185Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells/Nicco/Gloster/Asian
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 150Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells/Nicco/Gloster/Asian
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 120Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells/Nicco/Gloster/Asian
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 95Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells/Nicco/Gloster/Asian
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 70Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells/Nicco/Gloster/Asian
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 50Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells/Nicco/Gloster/Asian
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 35Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells/Nicco/Gloster/Asian
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 25Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells/Nicco/Gloster/Asian
Material & labour for chequered plate 5 mm thick size as per site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide primer and all as directed
Material and labour for fixing angle Iron of size 25x25x6mm size and square bar applying two coats of synthetic enamel paint over a coat of red oxide primer and all as directed
Material and Labour for Attending Faults/Trippings and rectifieng /repairing the faults in LT Panels Boards/Capacitor Panels Boaeds/ MCCB's/ACB's /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. Note : Damaged/Burnt MCCB/ACB'S/Changeover switc/Lugs.will be measured and paid separately)
Dismantling of Old Damaged/burnt spare parts from ACB and Supply and fixing in repair of following Spare parts suitable for -ACB 415V , 630 to 1200Amps Amps indoor type of Make ; Havells/ Schneider/IndoAsian/HPL/Legrand/C&S all as specified and directed by Engineer-in-Charge.
Shunt Trip Device
Closing coil assembly
Mismatch Prevention Device
Moving contacts assembly
Fixed Contact assembly
Auxialary Switch
Arc chut with hardware
Current Transformers 630A/5A.
Current Transformers 800A/5A
Current Transformers 1200A/5A
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,400 Amps,35kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,315 Amps,35kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,250 Amps,25kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,200 Amps,25kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,160 Amps,25kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,125 Amps,25kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,100 Amps,16kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,63 Amps,16kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3Pole,400 Amps,35kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3Pole,315 Amps,35kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3Pole,250 Amps,25kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3Pole,200 Amps,25kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3Pole,160 Amps,25kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. MMake: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3Pole,125 Amps,25kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. MMake: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3Pole,100 Amps,10kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. MMake: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3Pole,63 Amps,10kA, 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. Make: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch ,4Pole,400 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. MMake: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch ,4Pole,250 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC s incl addn/alttn of LT Panel complete all as specified and directed by Engr-in-charge. MMake: ABB/Siemens/Schnieder/Havells/Legrand/L&T/HPL or equivalent make as per approved by GE.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 300Sqmm to 240Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 185Sqmm to 150Sqmm -240Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 120Sqmm to 95Sqm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 70Sqmm to 50Sqmm complete all as specified and directed by Engr-in-charge.
Material and Labour for Attending Faults/Trippings and rectifieng /repairing the faults in HT Panels Boards/Cable Connections including HT insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. Note : Spare Parts.will be measured and paid separately)
Material and labour for Dismantling and taking out old Capacitor Panel and Supply , fix install testing and commissioning of APFC Panel board 200KVAR (Capacitor Panel) indoor type,cubical shape 3 phase, 4 wire, copper bus bar rating 600 amps for phases and 400amps for neutral made out of CRCA sheet , 2 mm thick ,factory fabricated, CPRI Certfied , powder coated ,dust and vermin proof , provn for ventilation , having seperate compartment /chambers for cable gallery busbar,switch gear,Capacitors, etc all as specified and comprising of following.
(a) Capacitor bank Heavy duty type,415Volts,Cylindrical type, 50Hz AC.
(i) 5KVAR -4Nos
(ii)10KVAR-4Nos
(iii) 15KVAR-4Nos
(iv) 20KVAR-4Nos
(b) Contactors Capacitor duty,TP,415Volts,50Hz AC suitable forfollowing.
(i) 5KVAR -2Nos
(ii)10KVAR-2Nos
(iii) 15KVAR-2Nos
(iv) 20KVAR-2Nos
(c) MCB,TP,415Volts,50Hz
(i) 10Amps -4Nos
(iv)32Amps-4Nos
(v) 40Amps -4Nos
(vi) 63Amps -4Nos
(d) APFC Relay, 16Stages digital type suitable for 415V, 3phase, AC supply
(f) Inbuilt Type Voltmeter,Ammeter,dital type with CT's,CTR 200/5A 96x96mm and Phase Indicating LED lamps-01Set
(g) ON/OFF Push Buttons and LED Indication Lamps-16Set
(h) Control wiring with 1.5/2.5Sqmm single core copper conductors,1100Volts Grade cable
(j) CT, CTR 200/5A in existing LT Panel with 2 Core 4 Sqmm Copper Cable
(k) SFU 400A,4P415V 50Hz AC Supply with HRC Fuses-01No
Supply fixing in replacement of battery 12 volts 180 AH suitabla for DG set starting complete all as specified and testing and commisioning complete all as specified and directed by Engineer In Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing surplus soil to a distance outside MoD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Only compacted thickness of sand will be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV Type I, flat, size 250 mm x 150 mm x 40 mm. laid in trenches complete all as specified and directed.
Supply & laying un-reinforced precast concrete cable cover class HV type 3 flat size 300mm x 150 mm x 40 mm complete all as specified and as directed.
Cutting metal road/hard standing for laying of cable and re metaling/making good the same to match the existing surface complete all as directed by Engr incharge.
M&L for GI pipe ,light grade 80mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, laying of UG Electric cable / staying of steel tubular pole etc. and getting out in hard/dense soil / road cutting & making good with bituminous where road cutting, complete all as specified and as directed .
Taking up old unserviceable XLPE insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including old concrete cable cover from trenches/walls/ceilling/poles etc any size all as specified and directed.
Supply and fixing, laying in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 4 core 10 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etc ,complete all as specified and as directed. Make: Polycab / Havells/ Asian (RPG)
Taking up loose XLPE cable from wall & Refixing only cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of sizes from 10 Sqmm 3.5 Core to 50 Sqmm 3.5 Core complete fixed on wall with suitable size of 'U' clamps with anchor fastner or saddles & screw all as specified and directed.
Supply and fixing in repairs LED lights fittings 8.5/9 Watt robustly designed IP65/IK10 with die cast aluminium housing, polycarbonate cover, single phase, 50Hz complete including all the accessories complete all as specified and directed by Engineer-in-Charge. Make- CAT Part No. BCP400 LED04 U CW PSU GR S1 of Philips or its equivalent in Jaquar/ Havells as approved by GE.
Supply and fixing in repairs LED light 9/10 Watt square shaped integral decorative LED bollard IP 65/IK10 With all acessories including PCC foundation tapper plug bolts, nuts, screwed complete etc complete all as specified and directed by Engineer-in-Charge. Make- CAT Part No. BCP 400 LED 09 D CW PSU GR S1 of Philips or its equivalent in Jaquar/ Havells as approved by GE.
Supply and fixing in repairs LED post top integral pole mounted decorative LED post top 50Watt with IP66/IK10 protection complete including all accessories including complete all as specified and directed by Engineer-in-Charge. Make- CAT PART No. BGP300 LED50 757 PSU PC IN S1 of Philips or its equivalent in Jaquar/ Havells as approved by GE.
Supply and lay in repair 40 mm dia GI tubing "light" grade for cable protection at road crossing/ hard standing/ plinth protection/ on the pole etc complete all as specified and directed.
Supply and fix in repair FRP type looping box of size 300x200x125 mm including necessary arrangement to fix the looping box with the suitable size of cable glands with entry, nuts,bolts, washers flat iron etc comprising of the followings:- Make of looping box - Hansel or equivalent Make of MCB- Legrand / Schneider / GE (a) MCB,63 Amps, TP (10 KA) (C series) - 01 No. (b) MCB 5 to 30 Amps, SP (10KA) (C series)-01 No (c) Neutral link - 01 No
Supply and fix in repair FRP type looping box of size 300x200x125 mm without MCBs including necessary arrangement to fix the looping box with the suitable size of cable glands with entry, nuts,bolts, washers flat iron etc Make of looping box - Hansel or equivalent
Supply and fixing in repair PVC insulated, stranded copper conductor of size 3 core 2.5 Sqmm in connection of FRP type looping box to light fitting connector, passing through GI pipe / tubular pole complete with fixing arrangement all as specified and directed . Make- Polycab/ Finolex/Havells
Dismentling connections & Taking out broken, damaged / rusted street light poles of any kind / make complete alongwith light fittings including necessary excavation, breaking PCC, returning/ filling and removing surplus soil out of MD land complete all as specified and directed.
Supply and fixing Steel tubular swaged street light poles complete with cast iron base plate ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 9.0 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole all as specified and directed by Engr-in-Charge. ( NOTE-Excavation & PCC will be measured and paid separately) Make :- National/Bombay Poles.
Material & Labour PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, base foundation filling concrete including necessary form work.
Material & Labour for PCC 1:3:6 type C2 using 20 mm graded aggregate block masonry with solid block ,exc 10 cm in width and setting in mortar complete for coping of pole including necessary from work and fair finish to the exposed surface area without using extra cement complete all as specified and directed.
Material & Labour PCC 1:2:4 type D2 using 40 mm graded stone aggregate for coping of the poles as in foundation, filling mass concrete, coping including necessary form work.
Supply & fixing in repairs LED Flood light fittings 75 Watt capacity in aluminium pressure die cast housing with toughened glass cover, High Power LED, secondary optics, IP 65/66, 10KV SPD, >100lm/Watt including wiring complete all as specified & directed. Make - Jaquar/ Philips/ Havells
Supply & fixing in repairs LED Street Light fittings 75 Watt capacity in aluminium pressure die cast housing with toughened glass cover, High Power LED, secondary optics, IP 65/66, 10KV SPD, >100lm/Watt including wiring complete all as specified & directed. Make - Jaquar/ Philips/ Havells
Supply & fixing in repairs LED Street Light fittings 90 Watt capacity in aluminium pressure die cast housing with toughened glass cover, High Power LED, secondary optics, IP 65/66, 10KV SPD, >100lm/Watt including wiring complete all as specified & directed. Make - Jaquar/ Philips/ Havells
Supply & fixing LED Flood light fittings 120 Watt capacity in aluminium pressure die cast housing with toughened glass cover, High Power LED, secondary optics, IP 65/66, 10KV SPD, >100lm/Watt including wiring complete all as specified & directed. Make - Jaquar/ Philips/ Havells
Supply & fixing in repairs LED Flood light fittings 250 Watt capacity in aluminium pressure die cast housing with toughened glass cover, High Power LED, secondary optics, IP 65/66, 10KV SPD, >100lm/Watt including wiring complete all as specified & directed. Make -Jaquar/ Philips/ Havells
Supply and fixing High intensity LED flood (Warm White) light fittings 400 W, specially designed for sports/Search etc. Alluminium housing , polycarbonate secondary optic cover, IP 66, > 110 lm/watt, 10KV SPD and wired with all acessories.Make: Phillips/Havells/Jaquar
Taking down U/S high mast light fittings of height 15 meter after lowering the arm including taking out winch, gear box, from high mast pole.
Material and labour required for oiling, greasing and servicing of steel wire rope , complete double drum winch system, control gear box, checking the internal wiring and balancing the arms duly vertical in position for smooth functioning of high mast tower complete all as specifed and directed.
Supply and fix in repair, replacement of complete control gear box for high mast lights of any height with all assessories as existing including alignment i.e. truly vertical in position, 2 point suspension system with steel wire rope 6 mm dia and suitable avaitiaon light as existing complete all as specified
Material & Labour for switching on & off the mast fittings by automatic control using astronomical timer and contactor for automatic switch on & off of mast at present time over current and latch mechanism including 4 core PVC flexible cable 2.5 Sqmm multi stranded copper with 3 pin metal clad socket to plug the supply for luminaries shall be mounted on PVC rigid board of suitable size provided in the base compartment of mast to terminate the incoming power supply cable from junction box to incoming luminaries complete outdoor type weather proof with MCB 63 Amps 4 pole 35 KA for incoming.
Supply and fix CC LED driver suitable for 45-75 W high power LED street light fittings, Vin- 230V, AC, 50Hz , Vout- 68-80V DC, PF > 0.95, Current (I in) : <1.25A, Current (I out) : 1.0-1.5A with IP rating 66 duly taking down the existing UNSV driver complete all as specified. Make- Jaquar / Philips/ Havells
Supply and fix CC LED driver suitable for 90-165 W high power LED street light fittings, Vin- 230V, AC, 50Hz , Vout- 88-93V DC, PF > 0.95, Current (I in) : <1.7A, Current (I out) : 1.5A with IP rating 66 duly taking down the existing UNSV driver complete all as specified. Make- Jaquar / Philips/ Havells
Supply and fix CC LED driver suitable for 400 W high power LED street light fittings, Vin- 230V, AC, 50Hz , Vout- 100-120V DC, PF > 0.95, Current (I in) : 0.110A, Current (I out) : 0.63 A duly taking down the existing UNSV driver complete all as specified. Make- Jaquar / Philips/ Havells
Supply and fix CC LED driver suitable for 250 W high power LED light fittings, Vin- 230V, AC, 50Hz , Vout- 32-42V DC, PF > 0.95, Current (I in) : <1.25A, Current (I out) : 1.0-1.5A with IP rating 66 duly taking down the existing UNSV driver complete all as specified. Make- Jaquar / Philips/ Havells
Material & Labour for taking down old defective street lights of any capacity from street light poles of any height and refixing after repair all as specified and directed by Engr - in - Charge. Note: Necessary driver/brackets shall be measured and paid seperately.
Material & Labour for in repair Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.5 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6 mm with the help of bolts, nuts, check nuts and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type D2 and PCC cover 1:2:4 type B1 watering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No.3 including connection to the earthing test point and testing on completion.
Material & Labour for preparation of deteriorated /rusted poles, scraping and applying two coat of aluminium paint after one coat of red oxide primer and marking the pole numbers with Black/ yellow paint complete all as specified and directed by Engineer-in-Charge. Make of Paint - Asian Paint / Berger / Nerolac
Material & Labour for required for attending & restoring the short circuits/sparking/tripping complaints and removing the burnt out parts, making proper insulation with insulating materials etc complete all as specified and directed by Engr - in - Charge.
Material & Labour for replacement of in repair old deteriorated street light brackets made out of GI pipe of 40 mm dia light grade, single arm of suitable size and shape complete including fabrication, fitting fixtures all as specified and directed at site by Engr - in- Charge
Material & Labour for replacement of in repair old deteriorated street light brackets made out of GI pipe of 40 mm dia light grade, Double Arm of suitable size and shape complete including fabrication fitting fixtures all as specified and directed at site by Engr - in- Charge
Material & Labour for in Repair/replacement coping of existing street light poles complete with PCC 1:2:4 D2 type 20 mm graded stone, painting after PCC work complete all as specified and directed at site by Engr - in- Charge.
Supply, Installation, Testing and commissioning of heritage aesthetic look (RAL Color Code 9007) post top luminaire (including light pole and lights as per description) having symmetrical distribution beam angle of 120°X120° (±5%) with housing material of Die-cast aluminum, powder-coated finish, PC cover; system wattage not exceeding 33W and system lumen output of not less than 3900 lumens with efficacy not less than 118 lumens/W. CCT of 3000K and CRI>=70 with SDCM<5. Weight not more than 8.5 kgs. Fixture shall operate in a temperature range of 0°C to 50°C . Fixture shall have input voltage for 100 – 277 VAC, 50/60 Hz. Lifetime should be at least 50,000 burning hours at L70 at 40 degree centigrade ambient. Fixture shall equipped with total IP65 protection and mechanical impact of minimum IK08. The fixture should be capable of surge protection upto 20kV minimum with salt spray test of 50hr. Luminaire driver should be EMI/EMC Compliant Luminaire dia must be minimum 460mm. LM79 and LM80 reports must be submitted along with the bid. Luminaire and driver should be of same make. Luminaire ies file (photometry file) must also be submitted along with the bid. Similar to PHILIPS BSS461 LED40WW 110-277V UNICLASSIC Should include Decorative poles with base plate and all associated items made out of MS pipe (finished with P.U. painted shade) of 301 Cm height and window at the bottom for space for MCB and terminal block for fixing LED post top integral mounted decorative LED light post suitable for 40/25/20 mm dia GI bend to desired shape as directed by Engineer-in-Charge. Similar to GUANA Poles NOTE :- Excavation & PCC will be measured and paid seperately
NOEL ENGINEERS
ORIENT ELECTRIC CO
Shree Ayyappa Engineering
AGRAWAL ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .