Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC | ₹6.2 L Quoted ₹7.4 L | L1 | Accepted-AOC Lowest tenderer |
| 2 | L2₹9.7 L+₹2.3 L (31.2%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | ₹9.7 L+₹2.3 L (31.2%) | L2 | Rejected-Finance Other than Lowest Tenderer |
| 3 | L3₹10.6 L+₹3.2 L (43.7%)Rejected-Finance | ₹10.6 L+₹3.2 L (43.7%) | L3 | Rejected-Finance Other than Lowest Tenderer |
| 4 | L4₹11.2 L+₹3.8 L (52.0%)Rejected-Finance | ₹11.2 L+₹3.8 L (52.0%) | L4 | Rejected-Finance Other than Lowest Tenderer |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Feb 2022, 6:00 pmClosed
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur-208008
REPAIR MAINTENANCE OF CEILING FAN, EXHAUST FANS, WALL MOUNTED FANS AND OTHER CONNECTED WORKS AT 7AFH KANPUR CANTT
2022_MES_502365_1
GE(AF)/CHK/T-43 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
7AFH Kanpur Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹30,000
Yes
12 Mar 2022
19 Jan 2022
22 Feb 2022
19 Jan 2022
16 Feb 2022
2 Feb 2022
Amount
M & L for servicing of ceiling fans, any sweep/size at existing position on various location of 7 AFH for maintenance after removing cable connection from ceiling rose, checking, tightening of thread of down rod, opening of fan, greasing/oiling of bush/ bearing, re-assembling and fixing the same in position including replacement of minor part such as split pin, lock bolt, check nut and cable flexible from ceiling rose to ceiling fan of site 23/0.0076 and connection etc including testing for its smooth running with complete all as specified and directed. (Note: Spare parts such as bearing, capacitor, bush etc. will be paid separately under respective item of Sch ‘A’ given here-in-after)
M&L for replacement of spare part for smooth functioning of boilor Make Thermax, Model No RXA06 complete all as specified and directed given as under :-
Ball bearing for ceiling fan of size 6201 to 6204 Make: NBC/ SKF.
Capacitor of 2.5 Mfd Make: Unistar /EPCOS
Gun metal bush as per sample
Ceiling fan blade set of three of 1200mm sweep.
M&L for rewinding of ceiling fan stator with appropriate gauge size super enameled copper wire including necessary insulation material after cleaning of stator for 1200 mm sweep ceiling fans complete all as specified and directed.
Ditto all as per item No. 3 here in before but for 1400 mm sweep ceiling fans
M & L for spray painting to ceiling fan with down rod, blade etc. of any make and sweep installed at various location of 7 AFH with two coat of Duco paint of approved colour & marking MES No including cleaning of old paint complete all as specified and directed.
Exhaust Fan M & L for servicing of exhaust fans, any sweep/size at existing position on various location of 7 AFH for maintenance after removing cable connection from ceiling rose, checking, tightening of nuts, bolts, opening of fan, greasing/oiling of bearing, re-assembling and fixing the same in position including replacement of minor part such as split pin and cable flexible from ceiling rose to ceiling fan of site 23/0.0076 and connection etc including testing for its smooth running with and including writing MES No with synthetic enamel paint complete all as specified and directed. ( Note: Spare parts such as bearing, capacitor etc. will be paid separately under respective item of Sch ‘A’.)
M&L for rewinding exhaust fan stator with super enameled copper wire of appropriate gauge including necessary insulation material complete varnishing and heating the new winding for proper insulation including cutting the existing winding wire from the stator and cleaning the slot complete all as specified and directed for following sizes of fan :-
225 to 300mm sweep
450 mm sweep
Supply only following items for exhaust fan:-
Capacitor 4 Mfd, 230 Volt
Ball bearing No. 6201, 6202, 6203, 6204
Exhaust fan blade of any sweep with screws/bolts, nuts.
Exhaust fan frame with louvers complete with nut & bolts etc.
PEDESTAL FAN M&L for repair & overhauling of defective Pedestal fan of any size by opening the blades, bearing, cleaning thoroughly internally & externally, providing fresh clean lubricants oil and greasing as required with and including M&L for rewinding the stator with super enameled copper wire of existing gauge with insulation materials, re-assembling the pedestal fan after replacement of defective components/ repair and replacing minor items such as clamp, back cover, screw lock, nuts, welding guards etc. including spray painting with a coat of synthetic enameled paint of approved shade after preparation of old surfaces and writing MES No. with black synthetic enamel paint including testing for its smooth functioning complete all as specified and directed. Note: Spare parts will be measured and paid separately under respective item of Sch ‘A’.
Supply only following items for exhaust fan:-
Gun metal bush as per existing size.
Capacitor 4 Mfd, 230 Volts oil filled
Pedestal fan blade
Pedestal fan shaft.
M & L for repair & overhauling of defective table mounted fan of any size by opening the blades, bearing, cleaning thoroughly internally & externally, providing fresh clean lubricants oil and greasing as required with and including M&L for rewinding the stator with super enameled copper wire of existing gauge with insulation materials, re-assembling the table fan after replacing minor items such as split pins, bolts, nuts, welding guards etc. including spray painting with a coat of synthetic enameled paint of approved shade after preparation of old surfaces and writing MES No. with black synthetic enamel paint including testing for its smooth functioning complete all as specified and directed.
WALL MOUNTED FAN Ditto all as per item No. 11 here in before but for wall mounted fan of any sweep.
Supply only following items of table fans:-
Gun metal bush.
Fan shaft.
Supply only following items of wall mounted fans:-
Capacitor 2.5 Mfd, 230 Volts
Gun metal bush.
Fan shaft.
M & L for replacement down rod of length 2 ft, 2.5 ft, 3 ft and 4 ft made out from GI Pipe 25 mm bore dia, medium grade for ceiling fan including fixing hook or clamp made out from iron complete with nuts and bolts and washers of suitable size duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down carefully point wiring from existing place (light/fan, socket or power points complete) with all fittings such as switches, sockets ceiling rose , pendant holder, fitting and fixtures , MCB DB’s , MCB, Main switches, call bell etc and making good to disturbed surface to wall ,floor etc to match with existing surface either by using same colour distemper or white colour wash all as required and directed.
Taking down care fully by unscrewing from boards /out let boxes ,fittings and fixtures such as Tube light fitting /of any type / /MCB DB etc complete all as specified and directed. Note : - This item to be operated only when item found serviceable for re –use in work.
M & L for point wiring PVC FRLS insulated and unsheathed copper stranded conductor cable of size 1.5 Sq mm, 1100 V drawn in and including PVC casing and capping complete including cast iron/pressed steel terminal box 1.6 mm thick of required size Bakelite sheet 3mm thick for mounting switch , socket brass screws and washer including PVC insulated and unsheathed solid copper wire of size 1.5 Sq mm will be used as continuous earth wire for the following points :-
One light /fan point controlled by one, one way switch
One 5/6 Amp socket on the same board with other switch
One 5/6 Amp socket on independent board.
One 3 pin 15 Amp socket independent but with 2.5 q mm PVC insulated unsheathed copper stranded conductor and earth wire with 1.5 Sqmm
One bell point controlled by one, one way bell push button.
Fixing only any type of Tube light fitting obtained from Item No. 17 Above Including making connection to ceiling rose /connector with copper flexible cable of size 1.5 sq mm complete all as specified and directed
S & F in replacement switch piano type 240 V, 5 Amp , SP one way flush type complete all as specified and directed.
S & F in replacement bell push 240 V, 5 Amp , SP one way flush type complete all as specified and directed.
S& F in replacement of socket out let 2 in 1 3 pin , 5 and 15 Amps
S&F in replacement of switch piano flush type single pole one way 15 Amps.
S & F in replacement of sheet metal enclosure for MCB DB TPN double door, 4 way complete with 200 Amps rated Bus bar complete all as specified and directed.
S & F in replacement socket out 5 pin 5 Amps flush type from the existing points.
S & F in replacement of switch socket out let combination multipurpose 3 Pin 5 amp, 240 volt and with 2 pin 5 amp out let also flush type including for existing points also (non shuttered) complete as specified and directed.
S & F in replacement of switch socket outlet combination 3 pin 15 Amp, 3 Pin 5 Amp out let also flush type (non shuttered) complete all as specified and directed.
S & F in replacement ceiling rose surface backelite, 65 x 20 mm three terminal complete all as specified and directed.
S&F for lamp holder metal cased body of brass with back plate with 5 Watt LED lamp complete all as specified and directed.
S&F in replacement sheet metal enclosures for MCB distribution board VTPN, 4 way double door type including with MCCB 4 Pole, 100 Amps, 16 KA fixed type as incomer with 200 amp rated bus bar complete all as specified and directed.
S & F sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed.
Ditto all as per item No. 31 here-in-before but SPN 4 way 240 Volt.
S & F in replacement Isolator SPN , 63 Amp , 240 Volt complete all as specified and directed.
S & F in replacement MCB SP upto 40 Amp ,240 Volt complete all as specified and directed.
S & F in replacement MCCB 4 Pole 16KA 100 Amps fixed type with sheet metal enclosures factory fabricated complete all as specified and directed.
S & F in replacement Isolator SPN , 20 to40 Amp , 240 Volt.
M & L for replacement of bell electric , 240 Volt , single pole.
M & L for replacement of regulator Electronic type 240 Volt single phase suitable for ceiling fan step type complete as specified
M & L for earthing complete with galvanized steel earth plate electrode of size 600 mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip of size 25 mm x4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to ear thing test point complete all as specified and directed including testing on completion including PCC type C-2 pit of (1:3:6) using 40 mm graded stone aggregate, RCC (1:2:4) Mix type B reinforced with 6mm dia MS bars @ 150mm RCC cover slab 40mm thick with two no’s fitting handle, GI pipe 20mm dia light grade with funnel & wire mesh for watering and 40mm dia light grade GI pipe for earth strip of size 32 mm x 6 mm protection etc (Earthing result not more than 2 ohm and test result duly signed) complete all as specified and directed. ( Note : Earth strip having length 7.5 Mtr per earthing shall deemed to be included in unit quoted rates)
M&L for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn in and including PVC rigid conduit 20 mm dia concealed type with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 2.5 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring complete all as specified and directed. Note. Two run of cable, one run of PVC conduit and one run of earth continuity wire shall be measured as one run unit complete all as specified
Ditto all as per item No. 40 here in before but for cross-sectional area 6 Sqmm, 2 single core with PVC FRLS insulated, unsheathed stranded copper conduct cable of size 4 Sqmm as earth lead complete.
S & F in replacement industrial type metal clad plug top & socket single pole and a natural link earth enclosure with MCB Sp 20 Amp complete all as specified and directed.
M & L for replacement of unserviceable bulk head fitting of any type with LED bulk fitting with 9 watt LED complete connection with copper wire 23/0076 two core from ceiling rose to bulk head fitting complete all as specified and directed.
S & F in replacement fluorescent tube light fitting complete energy efficient T-8 LED batten and integrated type signle tube 20 Watt, 4 ft long white complete with LED rod, LED driver and LED batten etc and all accessories pre wire and connecting up with copper three core flexible cord of min size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting arangement complete all as specified and directed. Make Cormpton Greaves/ C&S/Philips/Wipro/Havells.
S & F in replacement fluorescent tube light fitting complete energy efficient T-8 LED batten and integrated type signle tube 22 Watt, 4 ft long white complete with LED rod, LED driver and LED batten etc and all accessories pre wire and connecting up with copper three core flexible cord of min size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting arrangement complete all as specified and directed. Make Cormpton Greaves /C&S/Philips/Wipro/Havells.
M & L for replacement of existing unserviceable recessed mounted lumanaire with energey efficient 36 Watt LED type including making connection to ceiling rose with copper flexible wire of size 23/0076 complete all as specified and directed.
S and F in replacement of surface mounted downlight LED 16 Watt round in shape along with PVC 1.5 Sqmm 3 core wire from ceiling rose to light fitting including making good the disturbed surface complete all as specified and directed. Make : Philips Cat part No - SM251C LED16S-6500 PSU WH or Equivalent in Crompton Greaves/Havells as approved by GE in writting.
S & F in replacement of Isolator TPN , 100 Amp, 4 pole Isolator, 415 Volt complete all as specified and directed.
M & L for making holes for fixing of exhaust fan including cutting of existing wall of required sizes including nuts, bolts and washers and making good to disturbed surface of wall to match with existing surface either by using same colour distemper or white colour wash complete all as required and directed.
santosh electronics
LARSEN AIR CONDITIONING & REFRIGERATION
M/S Asian Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .