| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹41.9 L+₹10,058 (0.24%)Rejected-AOC BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-AOC Reject | |
| 3 | L3₹47.3 L+₹5.6 L (13.3%)Rejected-AOC | L3 | Rejected-AOC Reject |
Tender Value
₹61 L
EMD Value
₹1.2 L
Closing Date
16 Jan 2020, 6:00 pmClosed
CWE NW MUMBAI
DR HOMI BHABHA NAVY NAGAR ROAD COLABA MUMBAI
SPECIAL REPAIRS TO EM SERVICES AT OTM ACCN AT NAVAL DOCKYARD UNDER GE NW KUNJALI
2019_MES_307519_1
8336/CWE (NW) MUMBAI
Open Tender
Civil Works
Item Wise
210 days
GE NW KUNJALI
Class C and Category b (i)
9 documents required · 9 mandatory
₹1,000
Yes
GE NW KUNJALI
₹1.2 L
Yes
2 Mar 2020
18 Dec 2019
18 Jan 2020
18 Dec 2019
16 Jan 2020
31 Dec 2019
18 Dec 2019 - 24 Dec 2019
Amount
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½ core including disconnecting & taking down old damaged/unserviceable cable complete all as specified and directed
Supply & fix in repair of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A all as specified and directed by Engineer-in-Charge. Make: Siemens/Legrand/GE.
Supply & fix LED blukhead light fitting 10W, 230V, IP 65 including fixing on wall/ceilling with suitable connecting up with twin core copper cable with suitable size and all as directed by Engineer-in-charge. Make : Make : Bajaj Cat No BIBWP 10W LED/or equivalent in Wipro/CG/C&S
Supply & fix LED light fitting 1x20W, 230V, 4 feet surface mounted complete including fixing on wall/ceilling with suitable PVC squre block-02 Nos including connecting up with twin core copper cable with suitable size and all as directed by Engineer-in-charge. Make : Bajaj cat No BCLBAL 20W CW/ or equivalent in Wipro/CG
Supply & fix in repair LED light fitting 1x10W, 230V, 2 feet surface mounted complete including fixing on wall/ceilling with suitable PVC square block-02 Nos including connecting up with twin core copper cable with suitable size and all as directed by Engineer-in-charge. Make : Bajaj cat No BCLSB 10W CW/ or equivalent in Wipro/CG
Supply & fix in repair new generation recessed LED 2X2 Luminaire 36 watt for modern offices and CRCA powder coated body and high translucent diffuser provides high quality ecomonic energy saving lighting to modern offices. Suitable for 600 x 600 mm modular/POP/Gypsum ceiling. Make : Bajaj cat No BCTBLR 36W LED FP WH/ or equivalent in Wipro/CG
Supply & fix in repair double door vertical type TPN DB 6 Way, 240V with 200A busbar, IP-54 IK 09 protection suitable for housing MCCB's all as specified and directed by Engineer-in-Charge. Make: Legrand cat No 507751/ or equivalent in Seimens/GE. Note : DBs shall be concealed in wall including making good the surface to match with surrounding.
Supply & fix in repair of double door vertical type TPN DB 4 Way ,240V with 200A busbar, IP-54 IK 09 protection suitable for housing MCCB's all as specified and directed by Engineer-in-Charge. Make: Legrand cat No 507750/ or equivalent in Seimens/GE. Note : DBs shall be concealed in wall including making good the surface to match with surrounding.
Supply & fix in repair of SPN DB 08 Way, 240V with 100A copper busbar each phase, IP-54 IK 09 protection suitable for housing MCB's all as specified and directed by Engineer-in-Charge. Make: Legrand cat No 507641/ or equivalent in Seimens/GE. Note :- MCB DBs shall be concealed in wall including making good the surface to match with surrounding.
Supply & fix MCCB FP 160 Amps,16KA, complete all as specified and directed. Make : Legrand cat No 420017/ or equivalent in Seimens/GE
Supply & fix MCCB FP 100 Amps,16KA, complete all as specified and directed. Make : Legrand cat No 420015/ or equivalent in Seimens/GE
Supply & fix MCB SP 6-32 Amps,10KA, 'C' series 240V complete all as specified and directed. Make : Legrand/ or equivalent in Seimens/GE
Supply & fix MCB SPN 63 Amps,10KA 'C' series 240V complete all as specified and directed. Make : Legrand/ or equivalent in Seimens/GE
Supply & fix MCB TPN 40/63 Amps,10KA 'C' series 240V complete all as specified and directed. Make : Legrand 408659/408661/ or equivalent in Seimens/GE
Material & labour for sub-main wiring with 2 runs of 4.0Sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0Sqmm dia PVC insulated unsheathed copper conductor cable as earth conductor connected to earth dolly/mains including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Plaza/Havells/ Finolex. Note :- 3 runs of 4.0 Sqmm copper conductor and one meter of PVC casing and capping will be measured as one running meter
Material & labour for sub-main wiring with 2 runs of 10.0Sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC caping casing not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 10.0Sqmm dia PVC insulated unsheathed copper conductor cable as earth conductor connected to earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Plaza/Havells/ Finolex Note :- 3 runs of 10.0 Sqmm copper conductor and one meter of PVC casing and capping will be measured as one running meter
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, removing material to store for keeping in safe custody and making good to disturbed surfaces as directed by Engineer-in-Charge
Material & labour point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sqmm as earth continuity conductor connected to common earth dolly including required nos and size of modular box with cover plate frame in any module all as specified. Notes :- (a) Colour coding shall be followed as given below:- (i) Phase - Red (ii) Neutral - Black (iii) Earth - Green (b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
(a) One light point controlled by one 5A switch
(a) One fan point controlled by one 5A switch
(vi) One light point controlled by two 2-way switches
(iii) One Bell point controlled by one bell push
(e) One 5A switch socket combination on the same board
(f) One 5A switch socket point on independent board
Material & labour for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 2.5 Sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5Sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly including required nos and size of modular box with cover plate frame in any module complete for One 5 pin, 15A switch socket combination on the independent board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red/Yellow/Blue (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/Plaza
Material & labour for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5Sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly including required nos and size of modular box with cover plate frame in any module complete necessary electric connection for each workstation point comprising of 03 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red/Yellow/Blue (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/Plaza
Disconnecting & taking down ceiling fan, cleaning all parts and packing of ceiling fan of any make and size & greasing ball bearing with specified quilty grease including painting with synthetic enamal paint, re-assembling & re-comissioning the same including hanging on ceiling making electric connection complete all as specified & directed
Supply & fix ceiling rose surface bakelite 65 x 50mm, flush type, 3 terminals complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular switch 1 way 6A,1 module all as specified and directed by Engineer-in-Charge. Make: Anchor/Roma/Legrand.
Supply & fix modular switch 1 way 16A,1 module all as specified and directed by Engineer-in-Charge. Make: Anchor/Roma/Legrand.
Supply & fix modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed by Engineer-in-Charge. Make: Anchor/Roma/Legrand.
Supply & fix modular socket 6/16A,2/3 pin, combined 2 module all as specified and directed by Engineer-in-Charge. Make: Anchor/Roma/Legrand.
Supply & fix for modular fan step regulator, 120W - 2 modular all as specified and directed by Engineer-in-Charge. Make: Anchor/Roma plus/Legrand
Supply & fix bell, DINGDONG, 240 volts, complete all as directed.
Supply & fix moduler Bell push, 5/6 Amps, 240 volts complete all as directed.
Supply & fix modular switch 2 way 6A,1 module all as specified and directed by Engineer-in-Charge. Make: Anchor/Roma/Legrand.
Material & labour for GI pipe light grade 100mm dia for protection of UG cable crossing of nalha/bridge/road etc complete all as directed.
Material & labour cement concrete in 1:2:4 type B1 using 20mm grade stone aggregate for road cutting/pole couping exposed surfaced and fair and even finishing with out using any extra cement etc complete all as specified and directed
Material and labour for earthing complete with MS plate electrode of size 600 x 600 x 6 mm buried directly and preferably vertically in ground (earth pit not less than 2.25 mtrs deep below ground level ) with top edge of the plate not less than 1.5 Mtrs below ground level, connected to earth strip 25x4 mm galvanized MS strip by means of check nuts, bolts, washers etc all as shown in electrical plate No. 5 of SSR Part-I, connected to earthing test point including earth work, 1:3:6 C1 PCC chamber, 1:2:4 B1 PCC cover with 8 mm dia steel bars at 100 mm C/C suitable size of GI pipe for earth lead protection and watering, water funnel etc complete all as specified and directed.
Material & labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire all as specified and directed by Engineer-in-Charge.
Disconnecting & taking down old damsged/unserviceable cable & Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3½ core complete all as specified and directed by Engineer-in-Charge.
Disconnecting & taking down old damaged/unserviceable cable & supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
Taking down old U/S panel, and making good to Disturbed sufraces as directed by Engineer-in-Charge.
Taking down carefully old cable 35 Sqmm complete removing the materials and taken as credit and making good to disturbed sufraces of wall as directed by Engineer-in-Charge.
Supply, install testing and commissioning in replacement LT cubical panel board indoor type, IP- 52, Protection class factory fabricated, floor mounted self supported free standing type, made out of 2mm thick CRCA sheet with locking arrangment both sides openable, having cable alley of suitable size for easy connection of cables, dust & vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz AC including suitable size copper conductor control wiring and powder coating with 7 tank processes connecting the cable with necessary cable glands, lugs etc, proper arrangments for ventilation complete with and including cable glands and the following accessories:-
Supply and install testing and commissioning LT cubical panel board indoor type , IP 52 Each, protection class factory fabricated, floor mounted self supported free standing type , made out of 2 mm thick CRCA sheet with locking arrangement , both sides openable, having cable alley of suitable size for easy connection of cables , dust vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz AC including suitable size copper conductor control wiring and powder coating with 7 tank process connecting the cable with necessary cable glands, lugs etc , proper arrangements for ventilation complete with and including cable glands and the following accessories :-
Supply and install testing and commissioning LT cubical panel board indoor type , IP 52 Each, protection class factory fabricated, floor mounted self supported free standing type , made out of 2 mm thick CRCA sheet with locking arrangement , both sides openable, having cable alley of suitable size for easy connection of cables , dust vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz AC including suitable size copper conductor control wiring and powder coating with 7 tank process connecting the cable with necessary cable glands, lugs etc , proper arrangements for ventilation complete with and including cable glands and the following accessories :-
Supply and install testing and commissioning LT cubical panel board indoor type, IP 52 Each, protection class factory fabricated, floor mounted self supported free standing type , made out of 2 mm thick CRCA sheet with locking arrangement , both sides openable, having cable alley of suitable size for easy connection of cables , dust vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz AC including suitable size copper conductor control wiring and powder coating with 7 tank process connecting the cable with necessary cable glands, lugs etc , proper arrangements for ventilation complete with and including cable glands and the following accessories :-
Supply & fix PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100volts grade, cross-sectional area 35 sq, mm 3.5 core with suitable accessories all as specified and directed by Engineer-in-Charge. Make :- Polycab / Plasa / Havells / Finolex
Material and labour for earthing complete with MS plate electrode of size 600 x 600 x 6 mm buried directly and preferably vertically in ground (earth pit not less than 2.25 mtrs deep below ground level ) with top edge of the plate not less than 1.5 Mtrs below ground level, connected to earth GI wire 4mm dia galvanized MS strip by means of check nuts, bolts, washers etc all as shown in electrical plate No. 5 of SSR Part-I, connected to earthing test point including earth work, 1:3:6 C1 PCC chamber, 1:2:4 B1 PCC cover with 8 mm dia steel bars at 100 mm C/C suitable size of GI pipe for earth lead protection and watering, water funnel etc complete all as specified and directed.
AGRAWAL ASSOCIATES
ORIENT ELECTRIC CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .