Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 111 MINI SHOPPING COMPLEX NEAR HOTEL ASIA NEHRU MARKET JAMMU JAMMU KASHMIR 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | Accepted-Technical OK |
| 2 | Accepted-Technical | Accepted-Technical ok |
| 3 | Accepted-Technical BHAGWATI NAGAR JAMMU | Accepted-Technical ok |
| 4 | Rejected-Technical GOLE GUJRAL JAMMU JAMMU | Rejected-Technical NOT FULFIL TERMS AND CONDITIONS |
Tender Value
₹12.5 L
EMD Value
₹25,000
Closing Date
15 Jul 2026, 3:00 pmClosed
XEN JAL SHAKTI PHE MECHANICAL DIVISION UDHAMPUR
UDHAMPUR
Repair to 10000 GPH x 100 meter head HC pump set with 30 KW motor alongwith 110 ampere LT control panel (vishal area) alongwith allied works at WSS Thanova Swail, repair to 10000 GPH x 250 meter head HC pump set with 55 KW motor alongwith 140 ampere
2026_PHE_315110_1
ENIT NO. 38 OF 2026-27
Open Tender
Repair and Maintenance Works
Item Rate
30 days
XEN JAL SHAKTI PHE MECHANICAL DIVISION UDHAMPUR
Repair to 10000 GPH x 100 meter head HC pump set with 30 KW motor alongwith 110 ampere LT control panel (vishal area) alongwith allied works at WSS Thanova Swail, repair to 10000 GPH x 250 meter head HC pump set with 55 KW motor alongwith 140 ampere
2 documents required · 2 mandatory
₹500
XEN JAL SHAKTI PHE MECHANICAL DIVISION UDHAMPUR
₹25,000
3 Aug 2026
8 Jul 2026
16 Jul 2026
8 Jul 2026
15 Jul 2026
8 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.0 | Repair to 10000 GPH x 100 meter head HC pump set with 30 KW motor alongwith 110 ampere LT control panel (Vishal Area) Alongwith allied works at WSS Thanova Swail | - | - | - | - |
| 0.0 | Repair to 10000 GPH x 100 meter head HC pump motorset with motor alongwith 110 ampere LT control panel along with allied works at WSS Thanova Swail way of disconnecting of all electrical connections, decoupling of pump from motor, carrying pump-motor set from pumping station to road side by way of head load carriage and then to work shop by mechanical transportation. Dismantling pumpset and washing and cleaning of parts with thinner and Providing and fitting of new bearings as per old sample by removing the rusted bearings. providing and fitting of new gland packing, coupling bolts. Carriage of pump set back to pumping station by using manual labour tools and tackles and mechanical transport . Job further includes complete impregnation of motor by cleaning, varnishing and replacing rusted bearing as per sample. Coupling pump motor set and making proper alignment and testing the pump set on load at site. Job further includes repair to 110 ampere LT control panel. The job involves dismantling of all the incoming and outgoing power cables from the panel and shifting to workshop. The job involves replacement of damaged mccb, motor protection relay and replacement of rusted contactor kit of 110 ampere 3 pole power contactors-2no., voltmeter, amperemeter, CTs and fuse set with new corresponding components conforming to same rating and specifications. Testing of pump at site. Providing and fitting of copper cables 50 mm2 36 mtr and 35 mm2 30 mtr in length alongwith thimbling. Job also includes providing and fitting of 10000GPH x 10-13 mtr head mono submersible in suction along with cable and mug starter. Complete job includes cost of material, labour charges including to and fro carriage / loading / unloading charges. Rebate, if any, should be quoted separately.cluding to and fro carriage / loading / unloading charges. Rebate, if any, should be quoted separately. | 2 | Jobs | 0.29 | ₹0.58 |
| 0.9 | Repair to 10000 GPH X 250 METER HEAD HC pump set with 55 KW motor alongwith 140 ampere LT control panel (Thanova Area) alongwith allied works at WSS Thanova Swail | - | - | - | - |
| 0.0 | Repair to 10000 GPH x 250 meter head HC pump motorset with motor alongwith 140 ampere LT control panel along with allied works at WSS Thanova Swail way of disconnecting of all electrical connections, decoupling of pump from motor, carrying pump-motor set from pumping station to road side by way of head load carriage and then to work shop by mechanical transportation. Dismantling pumpset and washing and cleaning of parts with thinner and Providing and fitting of new bearings as per old sample by removing the rusted bearings. providing and fitting of new gland packing, coupling bolts. Carriage of pump set back to pumping station by using manual labour tools and tackles and mechanical transport . Job further includes complete impregnation of motor by cleaning, varnishing and replacing rusted bearing as per sample. Coupling pump motor set and making proper alignment and testing the pump set on load at site. Job further includes repair to 140 ampere LT control panel. The job involves dismantling of all the incoming and outgoing power cables from the panel and shifting to workshop. The job involves replacement of damaged mccb, motor protection relay and replacement of rusted contactor kit of 140 ampere 3 pole power contactors-2no., voltmeter, amperemeter, CTs and fuse set with new corresponding components conforming to same rating and specifications. Making of the complete internal control wiring afresh with flexible PVC copper wire of appropriate rating with proper thimbling. Testing of pump at site. Providing and fitting of copper cables 50 mm2 36 mtr and 35 mm2 30 mtr in length alongwith thimbling. Job also includes providing and fitting of 10000GPH x 10mtr head mono submersible in suction along with cable and mug starter. Complete job includes cost of material, labour charges including to and fro carriage / loading / unloading charges. Rebate, if any, should be quoted separately | 4 | Jobs | 0.16 | ₹0.64 |
| 0.9 | Repair to 250 KVA voltage stabilizer at WSS Thanova Swail. | - | - | - | - |
| 0.0 | Repair to 250 KVA voltage stabilizer at WSS Thanova Swail by way of disconnecting all electrical connections and making temporary arrangement for running of system. Dragging the stabilizer outside the pump room by deploying manual labour and with the help of tools tackles. Making of temporary arrangement so as to protect the stabilizer from rain / water during the repair work. Unfastening of nuts bolts and opening the top cover and then dismantling of complete unit by way of chain pulley block, tripod stand to draw out 03 no. coils and shifting to workshop. Servicing of 03 nos. coils with cleaning, heating and varnishing and shifting back to site. Filling of 400 liters transformer oil in the voltage stabilizer. Replacement of voltmeter, ampere meter, selector switches and rotary switches-3nos. Lowering the internal assembly inside the chamber and closing the top cover. Providing and fitting of 400 ampere bus bar and 300 Ampere MCCB. Making all incoming and outgoing electrical connections. Testing the stabilizer on no load at least for 6 hours and then on full load. Complete job includes cost of material, labour charges, hire charges of tools and tackles etc. (complete Job). | 1 | job | 0.29 | ₹0.29 |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_1021134.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .