EXECUTIVE ENGINEER
MVDA, MATHURA
WORK NO. 01 NANDGAV KASBA ME RANGEEN/L.E.D. LITE LAGANE KA KARYA
2026_UPMVD_1171331_1
18/MVDA/2026-27
Open Tender
Electrical Works
Lump-sum
120 days
MATHURA
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
Secretary
₹4.2 L
22 Jul 2026
22 Jul 2026
1 Aug 2026
22 Jul 2026
31 Jul 2026
22 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & fixing of 6 Mtr. Pole: - Decorative casting aluminum pole having cast Aluminium base height 1340mm and Minimum bottom size 504mm is reducing to top 153mm. The entire base is casted in gravity casting weight not less than 40Kgs. The bottom section of the pole 3000mmx140mmx3.0mm thick and top ribbed section of the pole 3000x114mm dia with base plated 300x300x12mm welded at the bottom of the pole. Pole is having a service window at bottom comprising four way connector and MCB for loop-in & loop-out arrangement. Pole is primer coating and polyurethane painted in dual shape antique paint with final coat of PU clear. DFT not less than 90 micron. Suitable for mounting drop down fixture including foundation and Monkey Protection, completee in all respect. Design as approved by MVDA. PSR | - | NOS. | - | - |
| 2 | Supply & fixing of Double Arm Bracket: - 1000mm long double arm bracket, 900mm over-hang (both Sides) bracket is provided for suspension of decorative lorence Drop Down Fixture. Bracket is made of Mild steel pipe with decorative embellishment With Monkey Protection. Design as approved by MVDA. PSR | - | NOS. | - | - |
| 3 | Supply and fixing of Florence-DD Fixture: - Ornamental 90 to 120 Watt LED Drop Down luminaire made of aluminum hosing duly powder coated/PU Painted with PU Paint/ frosted diffuser for high illuminance/glare free lighting. MCPCB having high lumen having LED’s are mounted on aluminium heat sinks.Design as approved by MVDA With 05 years on site warranty. PSR | - | NOS. | - | - |
| 4 | Supply & fixing of 7mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect,as per direction and approval of E/I. 641 SOR 2018 | - | NOS. | - | - |
| 5 | Supply of Solar AIO, Indigenous Single piece High pressure Die cast Aluminium housing, IP65 & IK08, suitable for OD 50/60mm bracket, having Min 5000 lumens & 30 W suitable for 24hrs (2 Nights) Autonomy and its backup calculation sheet shall be approved by Engineer-In-Charge. Dimming Profile
• From Dusk – First 05hours sensor enabled with 30% brightness level
• Next 05Hours sensor disabled and fixed at 30% Brightness level
• Next 2hours/dawn- Sensor enabled with 30% brightness level.
Maintenance Lithium phosphate Battery capacity min 384watt hour/30AH 12.8V &shall be of fresh manufactured battery (Not re-used cells) Battery Temp range -10-+50℃ and panel capacity min 60Wp, CRI >=70, Efficacy 180lm/W. Life class of LED System 50000hrs@L70, Manufacturing unit shall be of OEM self or other shall be UL approved manufacturing unit for better quality. LED Make - CREE/NICHIA/LUMILEDS, CE Certified, charger efficiency >90% and standards IEC62109-1, IEC61547, CISPR15, IEC62093, IEC61347-2-13, EN50530, IEC62384 The PV module should be made up of crystalline silicon solar cells "Mono-Crystalline" BIS of battery & Panel, Test reports IES LM79-19, LM80, IP & IK test reports from NABL approved Lab only. (BIS/ISO approved make) with onsite product warranty and operation and maintatenence of 5 year .O&M included 24 hours (2 Nights bettery backup and optimum lux level through the O&M period) priodic cleaning of solar panel minimum once in a month or as per direction of E/I to maintainance optimum lux leval of lights. Costomisation of solar light regarding motion sensor and dimming profile as per direction of E/I. PSR | - | NOS. | - | - |
| 6 | Supply and fixing of plain or pin type copper tin plated cable socket (lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the E/Ic. PWD SOR 2018 S.I. No. 504-D16 Sq. mm. | - | NOS. | - | - |
| 7 | Making suitable earthing of street light pole with 2.5m long 20mm dia. Ms rod with 7/16 SWG GS Wire in 15mm dia. 2 meter long GI pipe duly clamped with 2 nos. of clamps and winding on pole including cost of labour and T&P etc.required for proper completion. PSR | - | NOS. | - | - |
| 8 | Numbring of Pole with 6' circule Yellow paint base and number with black paint ,as per direction and approval of E/I. PSR | - | NOS. | - | - |
| 9 | Supply and laying of 16 sqmm 4 core aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PWD SOR 2014 S.I. No. 501-I | - | MTR. | - | - |
| 10 | Supply and fixing of 4 sqmm 2 core flat twin "AL" cable complete with labour T&P an dall taxes as per direction by E/I. PSR | - | MTR. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.83 MB
TD18.pdf
Tender Documents • 1.60 MB
BOQ_2198931.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].