Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹56.3 L+₹6.5 L (13.1%)Rejected-Finance MAJUMDER COLONY BURDWAN ROAD SILIGURI DIST DARJEELING WB PIN 734 014 | DARJEELING | WEST BENGAL | 734014 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹56.6 L+₹6.8 L (13.6%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹56.7 L+₹6.9 L (13.8%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹56.7 L+₹6.9 L (13.9%)Rejected-Finance UPPER BAGDOGRA PO BAGDOGRA DIST DARJEELING PIN 734014 WB | BAGDOGRA | DARJEELING | WEST BENGAL | 734014 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
15 Dec 2021, 6:00 pmClosed
GE BENGDUBI
Bengdubi Military Station PO-Bengdubi, Dist-Darjeeling, Pin 734424
GE/BENG/52 OF 2021-22 PROVN OF 03 X ALUMINIUM DOOR, RETAINING WALL TO PREVENT LAND SLIDING, SEPTIC TANK SOAKAGE WELL, SR TO BLDG NO T-26 T-29 AND VEH WASHING POINT AT CERTAIN UNITS OF GRTE UNDER AGE B/R-II AGE E/M OF GE BENGDUBI MIL STN
2021_MES_488595_1
GE/BENG/52 OF 2021-22
Open Tender
Civil Works
Works
240 days
GE BENGDUBI
MES Enlisted/ Un-enlisted contractor of Class D and above with category a(i)
8 documents required · 8 mandatory
₹500
Yes
GE BENGDUBI
₹91,000
Yes
15 Jan 2022
16 Nov 2021
17 Dec 2021
16 Nov 2021
15 Dec 2021
3 Dec 2021
18 Nov 2021 - 23 Nov 2021
Amount
SCHEDULE 'A' PART-I (B/R WORKS)
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.5 mtr deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc and getting out in soft/loose soil complete all as specified.
Ditto all as per Item no 2.00 here-in-before but exceeding 1.5mtr not exceeding 3.0mtr deep complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft / loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance exc 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
Excavation over areas not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Ditto all as per Item no 5.00 here-in-before but exceeding 1.5mtr not exceeding 3.0mtr deep complete all as specified.
Rough excavation not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
M&L for hand packing with broken stone or boulders (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling & mass concrete complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling & mass concrete complete all as specified and directed.
M&L for TMT bars (Fe-500/ Fe-550D) 10 mm dia & over, cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per item No. 11.00 here-in-before but 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders complete all as specified and directed.
M&L for Reinforced cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc., basement slabs, under-reamed piles and mass concrete etc all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) in in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases)complete all as specified and directed.
M&L Reinforced cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L Reinforced cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in chajjas and in shelves and the like complete all as specified and directed.
Use & Waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed.
Use & Waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to chullah hoods, chajjas, troughs and similar items including edges, rough finished surface of concrete complete all as specified and directed.
Dimantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings including ridges, valley gutter etc, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position like trusses, rafters, purlins etc. complete all as specified and directed.
S&F Pre-painted coloured trapezoidal profiled Galvalume / Zincalume sheet with min thickness of 0.50 mm TCT confirming to IS-513 (AZ-150 GSM, AI Zn alloy mettalic coating with 550MPA yield stress as per AS-1397) as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted coloured plain Galvalume / Zincalume sheet with min thickness of 0.60 mm TCT confirming to IS-513 (AZ-150 GSM, AI Zn alloy mettalic coating with 550MPA yield stress as per AS-1397) as in roof ridge /valley gutters fixed with Galvanised self drilling self tapping fastener (12-14 x 55 with EPDM seals) complete all as specified and directed.
M&L Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc.for post (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming Fe-410W(GdeE-250) quality B complete all as specified and directed.
S&F for rolled sections as in main and cross beams, hip and jack rafters; purlins, Gusset plate and base plates, where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, Fe-410-Wgde -E-250) quality 'B' includng welding or riveting etc complete all as specified and as directed
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W (Gde-E-250 quality-B) complete all as specified and directed.
M&L Mild steel screw bolts purpose made with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 22.5cm and n exc 30cm long and dia of neck from 11 to 15 mm complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness, including cover fillets, and existing frame work also, complete all as specified and directed.
M&L for Non asbestos designer fibre cement building boards of 4 mm thick, used as a panel insert in a frame work with screws complete all as specified and as directed.
S&F of Gl frame work for ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed.
M&L for Vitrified (light/dark coloured) ceramic tiles 9 to 10 mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete including screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
Ditto all as per item No 35.00 above but for vertical surfaces such as skirting etc,size 600x150mm over and including 10mm thick back coat in CM 1:4 complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match with the shade of tiles, over and including 15mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for Glazed ceramic tiles of size 300mmx 450mm , 6 to 7 mm thick on the vertical surfaces such as in skirting / dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with the shade of the tiles, over and including 10mm thick cement mortal backing coat in CM 1:4 complete all as specified and and as directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc. Laid, bedded and pointed in any mortar complete all as specified and directed.
M&L for 15mm thick machine cut, pre-polished black jet, premium quality granite stone slab in skirting, Kitchen platform /dado etc laid over including 15mm thick screed bed in CM 1:4, jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding the edges half round and polishing including etc complete all as specified and directed.
M&L for 18-20 mm thick Machine cut, pre-polished kota stone slab (single piece) in floor laid over including 15mm thick screed bed in CM 1:6, jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade complete all as specified and directed.
M&L for rounding to edges of stone slabs edge (Double moulding), counter vanities etc including machine polishing to edge to give high gloss finish complete all as directed.
Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified and directed.
M&L for brick work with fly ash brick, straight or curved on plan exc 6.0 mtr mean radius built in CM 1:6 etc complete all as specified and directed.
M&L for brick work with fly ash Bricks straight or curved on plan in CM 1:4 as in half brick thick walls complete all as specified and directed.
M&L for brick work with fly ash Bricks in one brick thick honey -comb walling, built in CM 1:4 complete all as specified and directed.
M&L for Loose filling with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for Rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 with water proofing compund as per manufacurer's instructions, finished surfaces fair and smooth without using extra cement complete all as specified and directed. (Note: - WPC shall be measured and paid separately under relevent items.)
M&L for Rendering 20mm thickin two layers (10+10mm) externally on fair faces of brick or concrete surfaces in cement mortar 1:4 with water proofing compund in top layer of 10mm thick as per manufacurer's instructions, finished surfaces fair and smooth without using extra cement complete all as specified and directed. (Note: - WPC shall be measured and paid separately under relevent items.)
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) etc complete all as specified and as directed
M&L for rendering 15 mm thick in CM (1:6) on fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) etc complete all as specified and as directed
Supply only water proofing compound (Liquid) complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n.exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition reinforced cement concrete (reinforced) as in roof slabs (other than grond floors) beams, staircases, landing, chajjas, beams and similar suspended work complete all as specified and directed.
Demolition reinforced cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for all as specified and directed.
M&L Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors set and jointed with grey cement slurry and pointed with pigment to match the shade complete all as specified and directed
M&L for 100 mm thick PCC 1:4:8, type D-2 , using 40mm graded crushed stone aggregate as in sub base for hard standing and ramp all as specified.
M&L for hardcore of gauge not exc. 63mm, deposited, spread and levelling in layers not exc. 15 cm thick, watered and rammed to true surface with broken stone or boulder complete all as specified and directed.
M&L 50mm thick PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in flooring, finshed even and smooth without using extra cement complete all as specified and directed.
M&L for 75 mm thick PCC type C-2 1:3:6, using 40mm graded crushed stone aggregate as in sub base for receiving floor finishes all as specified.
M&L for 75 mm thick plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in plinth protections, finished even and smooth w/o using extra cement with joints 10 mm wide and in full depth at corners and @ 3.0 m c/c filled with mastic mortar complete all as specified and directed.
M&L for providing 25mm thick PCC (1:2:4) type B1 (using 12.5mm graded stone aggregate) as in floor/ roof padding complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate in lintel upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs, fixing of hold fast and the like including weathering, slightly rounded or chamfered angles and throating, as directed including formwork if required complete all as specified.
Taking down chowkats or frames n exc 1.5 Sqm each (with out taking off shutter from the frame) and removing material from the site of work complete all as directed.
Taking down chowkats or frames exc 1.5 and n exc 4.0 Sqm each (with out taking off shutter from the frame) and removing material from the site of work complete all as directed.
S&F factory made solid panelled PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails.MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet bedding and joined together with solvent cement etc complete all as shown on drg at Srl page No 176 of MES Schedule Part-II(2020), complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F 150mm long aluminium alloy handle, cast type anodised (ISI Marked) complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section with 100 mm long bolt (ISI Marked) complete all as specified.
S&F aluminium anodised barrel tower bolts of extruded section with 200 mm long bolt (ISI Marked) complete all as specified.
S&F 100 mm thick butt hinges, medium weight, stainless steel and fixed etc complete all as specified and directed.
S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and directed.
S&F standard powder coated aluminium section and shall be approved by Garrison Engineer as on frame, shutters of doors, windows & ventilators , fixed / openable/ side hung / sliding two or three track or any pattern, partition , kitchen cabinet, almirah etc with cadmium plated steel screws, including rubber beading or gaskets for fixing glass and stainless steel wirecloth and particle board, etc complete all as specified and directed. Note : (i) Weight of Aluminium sections as per actual or as per IS or as per Manufacturer which over is less, shall only be considered for payment. (ii) Cost of all the items/ accessories required for the entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and particle board shall be measured and paid separately under respective items. (iii) The accessories required to be provided for partition as per directions of Engineer-in-chargeshall be provided but weight for the same shall not be considered and no extra cost will be paid.
S&F 1.25 mm thick pressed steel frame of size 165 X 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and directed.
S&F 35mm thick flush shutter solid core construction with block board core and ply wood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and as directed
M&L for 2nd class hard wood (Hollock/Kalasiris/Brjsal/Gamari) (kiln seasoned and chemically pressure treated) 35 mm thick glazed and skeleton shutters, open rebated and prepared to rceieve glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, sizes of members of shutters as specified in SSR Part-1, Section 8, clause 8.24 (a), complete all as specified and directed.
S&F 5mm thick sheet visual glass of ordinary quality one side including glazing clips, rubber packing in squares n exc 0.50 sqm in each pane complete all as specified and directed.
S&F 4mm thick sheet glass of ordinary quality and glazing with oil putty or wooden beading to wooden frame or steel frame in squares n exc 0.50 sqm in each pane complete all as specified and directed.
S&F 3mm thick one side frosted glass of ordinary quality and glazing with oil putty or wooden beading to wooden frame or steel frame in squares n exc 0.50 sqm in each pane complete all as specified and directed.
M&L 9mm thick Pre laminated interior grade prelaminated both sides with decorative choice laminations fixed with screw of jointing cleats to aluminium frame work complete all as specified and as directed
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint complete all as specified and directed.
M&L preparation of old painted surfaces of steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
M&L preparing new wooden surface of any description, not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and directed.
M&L for complete removal of existing treatment of wall and applying two coats of oil bound distemper of approved tint over a coat of alkali resistant primer on wall over complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coat Birla/Asian wall care putty and two coats of oil bound distemper of approved tint over a coat of alkali resistant primer on wall over complete all as specified and directed.
M&L for applying two coat of white washing (Lime wash white) on ceiling surfaces including preparation of old decorated plastered /unplastered surface of ceiling by brooming down,scrapping cleaning & removing down smoke soot, moulds, moss and efflorescence etc complete all as specified and directed.
M&L complete removal of existing treatment of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces as in walls etc. complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces as in walls etc. complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coat acrylic smooth exterior paint coat over a coat of primer (Two coat applied 1.67 Litre/10 Sqm over priming coat @2.2kg/10Sqm) complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank 500ltrs capacity, ISI marked, (cylindrical vertical type double-layered) with closed top including inlet, outlet and wash out holes, provision of G.I Fittings for fixing of the inlet, outlet and washout pipes, hoisted in position complete all as specified and directed.
S&F stop valve 20mm bore, cast copper alloy with crtuch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F ball brass valve, high pressure, with ploythene float and flynut complete, screwed for iron pipe or brass ferrule 20 mm bore complete all as specified and directed.
S&F in repair sinks made of stainless steel 0.80mm thick kitchen with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 485mm x 420mm bowl size 410mm x 330mm x 160mm etc complete all as specified and directed.
S&F vitreous china wash down water closet semi pedestal anglo Indian pattern (excluding flushing cistern and flush pipe) including connection to out going pipe, & seat cover and flushing pipe complete all as specified and directed.
S&F in repair Vitreous China wash down water closet pan european type (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device and also including cast iron S trap, bore of pipe 100 mm. and provision of concrete bedding complete all as specified and directed.
S&F in repair PVC valveless double syphonic action type flushing cistern low level of 10 Ltr capacity white with inlet ball valve, float, flushing bend & handle including brackets, suitable for both Indian Type Water Closet & Europeon Type Water Closet including brackets & connection to pipe etc complete all as specified and directed.
S&F 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F in repairs Pillar taps, fancy type, cast copper alloy, with long swan neck , chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe of 15mm bore, complete all as specified and directed.
S&F angle stop valve 15mm bore, cast copper alloy with crtuch or butterfly handle, screwed down, screwed for iron concealed pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repairs bib tap, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of 15 mm bore, complete all as specified and directed.
S&F shelf PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed.
S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and as directed.
S&F in repairs tubular towel rail, 20mm dia, D type, brass chrormium plated, 600mm long between flanges, complete all as specified and directed.
S&F in repair PVC connection of 15mm dia 45 cm length including two PVC PTMT nuts at ends with rubber washer complete all as specified and directed.
Taking up or down GI tubing of 15mm bore and connections, including cleaning for refixing or removal to store all as directed.
Taking up or down GI tubing of 20mm bore and connections, including cleaning for refixing or removal to store all as directed.
S&F galvanised steel water tubing, 'medium grade' ISI marked galvanised 15mm bore, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F galvanised steel water tubing, 'medium grade' ISI marked, 20mm bore, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F galvanised steel water tubing, 'medium grade' ISI marked, 25mm bore, with all fitting and fixed complete to walls and ceilings or laid in floors/trenches complete all as specified and directed.
Refixing old 15mm bore GI steel tubing and connections in new or old position laid in trenches/Walls/ceiling/ floors, etc. all as directed.
Refixing old 20mm bore GI steel tubing and connections in new or old position laid in trenches/Walls/ceiling/ floors all as directed.
Dismantling of cast iron or reinforced concrete pipes, jointed incement mortar pipes up to 100 mm bore in any position all as directed.
Taking down PVC rain water pipes ( any size or pattern) including all fittings head shoes etc complete all as specified and directed.
S&F 100 mm bore cast iron soil, waste and vent pipes(spun pipes), in any length with or without ears with cement joints, laid in trenches or in floors or vertically cast/fixed in wall complete all as specified and directed.
S&F 100 mm dia cast iron vent cowl complete all as specified.
S&F 110 mm dia PVC (SWR`) pipes single socketed in any length with rubber rings joints fixed to walls with leakproof joint as per manufacurerer instructions complete all as specified.
S&F 110 mm dia PVC (SWR`) in short pieces for weep holes complete all as specified.
S&F 110 mm dia PVC (SWR`) vent cowl complete all as specified.
S&F 110mm bore PVC (SWR) 'P' or 'S' trap fixed with leakproof joint as per manufacurerer instructions complete all as specified.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal, fixed with leakproof joint as per manufacurerer instructions complete all as specified.
S&F 110mm bore PVC (SWR) bends nay radius, fixed with leakproof joint as per manufacurerer instructions complete all as specified.
S&F 75mm dia PVC (SWR`) pipes single socketed in any length with rubber rings joints fixed to walls with leakproof joint as per manufacurerer instructions complete all as specified.
S&F 75mm bore PVC (SWR) bends nay radius, fixed with leakproof joint as per manufacurerer instructions complete all as specified.
S&F grating doom 100mm dia of PTMT (minimum weightt 25 gm) for floor trap/nahani trap complete all as specified and directed.
S&F 140 mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring all as directed.
S&F aluminium 75mm mortice lock brass vertical type 2 lever all as approved by Engineer-in-charge.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed
Cutting holes into or through brick walls built in brick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required all as specified.
M&L for precast RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and directed.
Demolition / breaking up damaged SGSW pipe of any position of internal dia of pipe 150 mm including demolition of PCC, and removing dismantled material at a distance n exc 50 m all as directed.
M&L for Plain cement concrete 1:3:6 type C-2 (Using 40mm graded crushed stone aggregates) as in bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150mm bore complete all as specified and directed.
M&L for Salt glazed stone ware (SGSW) drain pipes laid in trenches and jointed as specified in 150mm internal dia of pipe grade 'A' complete all as specified and directed.
S&F in repairs Salt-glazed stoneware gully traps, square or round mouthed, type `P', 'q' or 'S' of size 150x150 including for conecting to drains and setting in cement mortar 1:1 complete all as specified and directed.
Cutting salt-glazed stoneware drain pipe in position, including jointing socket end of new pipe to same with packed spun yarn and cement mortar(1:1) 150mm internal dia of pipe complete all as specified and directed.
M&L for world squash federation (WSF) approved squash court hard plaster 12 mm to 15 mm thick in two layer fiber glass reinforced cement based for liveliest and rebound action due to superior rigidity and hardness alongo line surface toughness that resist wear,splintering,abrasion, chipping and stress, red game line with 5 year warranty for hard plaster against damage as per manufacturer specification all as directed.
S&F wooden flooring system maple hardwood sports floor(BWF certified) EN north american tallehardwood maple size :20 mm thick x 57/83 mm width tounge & groove system 38 mmx63.5 mmx1.22 meter treated pine wood sleepers installed at 9" (23 cm) distance with 19 mm thick power pads sanded,klin& dried treated with vapour barrier of 6mil polythene laid on PS, including providing self levelling corse with ardex cl-I (self smoothening) cemntitous underlay in avg 3-4 mm thickness with primer ardex P-51(for porous surface) for first coat diluted withwater 1:1 or non porous surface use ArdexP-82 as primer in single coat after completion of surface preparation repair of pot holes/ crack/joint filling etc with repair mortar and complete as per ardex guideline complete in all respect as per manufacurer specification as directed.
S&F sound board WSF certified 21ftx19 inch made up of steel 14 gauge with white enamle paint inclusive of wooden frame work and top 50 mm wooden batten with game line as per WSF(specification)
Material & labour for providing and fixing stainless steel (Grade 304) Railing made of hollow tubes, channeles, plates etc, including welding, grinding buffing, polishing and making curvature(whever required and fitting the same with necessary stainless steel nutand bolts complete, including fixing the railing with necessary accessories & stainless steel dash fastner,stainless steel bolts etc, of required size, on top of floor or side of waiste slab with suitable arrangments all as directed.
S&F 10 mm thk toughned glass pannel chamfered edge with necessary making hole for fixing with stainless steel frame and sealing the sides with silicon gel and stainless steel L- shaped fastners in ground for support all as specified and directed.
M&L for Machine cut kota stone slab 18-20 mm thick, (table rubbed) (moulded exposed edge), in riser and steps, skirting, dado, over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding the edges half round and rubbing and polishing including rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface as backing coat of dado/skirting etc complete all as specified and as directed.
SCHEDULE 'A' PART-II (E/M WORKS)
Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface of walls, floors etc as per existing specification complete all as specified and directed.
M&L for concealed point wiring One light point/one fan/light/exjaust/bell point controlled by one switch with FRLS PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200mm x 300mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface all as specified and directed.
All as per item No 146.00 here-in-before but One 3 pin socket outlet, 5 Amp on independent board all as specified and directed.
All as per item No 146.00 here-in-before but One 3 pin socket outlet, 5 Amp on same board all as specified and directed.
All as per item No 146.00 here-in-before but for one 15 Amp 3 pin switch socket outlet, independent with 2.5 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire complete all as specified and as directed.
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 5/6 Amp, complete all as specified and directed.
S&F Switch socket combination multipurpose 2 in 1, 6Amp flush type complete all as specified and directed.
S&F Switch socket combination multipurpose 3 pin 16A and one 3 pin 6Amp 5 in 1 flush type complete all as specified and directed.
Supply and fixing including connection call bell AC 230 volts, single pole, Make : ANCHOR/CONA/BAJAJ/.
Supply and fixing including connection of bell push button type 5 Amps, Make : ANCHOR/BAJAJ/CONA
S&F Ceiling rose, 3 way PVC insulated body complete all as specified and directed.
S&F ceiling fan regulator electronic stepping type flush type ( 2-Module) including necessary electric connection complete all as specified and directed.
S&F LED Tube Light luminaries with high performance LED with driver 1 x 18W (4 Feet long, Cool day/Warm white) complete with all accessories internally pre-wired and including connection two core twisted flexible copper conductor cable all as specified and directed.
S&F LED Tube Light luminaries with high performance LED with driver 1 x 9W (2 Feet long, Cool day/Warm white) complete with all accessories internally pre-wired and including connection two core twisted flexible copper conductor cableall as specified and directed.
S&F in replacement 36W LED Square Type 2' x2' recessed type with high efficiency PMMA diffuser soft glare fre light including suitable driver, cutting of False ceiling as required and all accessories for fixing arrangement pre-wired and including connection two core twisted flexible copper conductor cableall as specified & directed.
S&F Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings including 8 Watt LED bulb all as specified and directed.
S&F Building security LED light luminaire fitting 1X15W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt, nut,washer,clam made out of MS flat of size 25X3 mm, 4 nos Anchor Bolt of suitable size etc all as specified and directed.
S&F vehicle washing plant compressing of mono block compact wheel driven pump 2 HP single phase, 230 Volts, 50Hz, 2900 Rpm of capacity 12 ltr/min of pressure 80-100 Kg/sqmm section 12mm and delivery 6mm including suction pipe 3 mtr high pressure delivery pipe with jet gun complete all as specified and directed.
M&L for taopping of pipe line from existing water main and insert a tee from main pipe of any size including all necessary material complete all as specified and as directed.
S&F gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe of size 25mm dia and fixed complete all as specified and diercted.
S&F LED 100W highway light, robust and environment friendly, with high efficency suitable for ceiling (suspended / surface type) complete all as specified and directed. (Make Havells cat part No : SAUCERGENXPROHBP100WLED757P90BOLTG or equivalent model of Philips / Cromptons)
S&F Single Pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 16/25Amp complete all as specified and directed.
Taking down of Old MCB DB / control box any type any size including MCBs and separating the serviceable MCB DBs and MCBs for reuse at site complete all as specified and directed.
S&F Sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with common bus bar at incomming end complete all as specified and directed. (Make:Legrand/havells/L&T/ABB).
S&F Sheet metal enclosure for MCB DB double door single pole & Neutral 12 way with common bus bar at incomming end complete all as specified and directed. (Make:Legrand/havells/L&T/ABB).
S&F MCB 'C' series single pole & neutral 40 to 63 Amps, breaking capacity 10KA, complete all as specified and directed. (Make: Legrand /L&T/ C&S/ Indoasian)
S&F MCB 'C' series single pole 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (Make: Legrand /L&T/ C&S/ Indoasian)
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through 25mm dia PVC Conduit complete all as specified and directed. Note :- (a) PVC Conduit / casing- caping shall be included in quoted rate. (b) For concealed sub-main wiring cutting chases will be included in same rate. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
M&L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm as earth continuity conductor drawn through 25mm dia PVC Conduit complete all as specified and directed. Note :- (a) PVC Conduit / casing- caping shall be included in quoted rate. (b) For concealed sub-main wiring cutting chases will be included in same rate. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
Taking out Old un-serviceable / faulty cable of any size from trench / pole complete all as specified and directed.
M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 16 Sqmm 2 core laid in trench/pole/on wall completer all as specified and directed.
M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 10 Sqmm 2 core laid in trench/pole/on wall completer all as specified and directed.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed.
Material and labour well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and directed.
M&L for 50mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls/ poles/ under road/ floor etc for cable protection, complete all as specified and directed.
M&L for 40mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls/ poles/ under road/ floor etc for cable protection, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron earth lead wire 4.00 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel, GI earth wire protected by 15mm bore light grade GI pipe and other end connected to earthing test point or main switch board as directed including funnel with watering pipe of 20mm bore light grade GI, wire mesh, charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode PCC (1:3:6) type C-1 earth pit, cast iron cover and frame, including necessary excavation and earth work and refilling of black soil good conductor of earth and necessary testing complete all as specified and directed and shown on electrical plate No 3 of MES Schedule Part-I complete all as specified and as directed.
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 67,960.00 (refer Tender Srl Page No 52). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
M/S P. RAI CHOUDHURY AND CO.
PRADIP KUMAR BOSE
UNIVERSAL CONSTRUCTION
SHRI S K BHATTACHARJEE
MUKHERJEE ENTERPRISE
GURUNG CONSTRUCTION
Paritosh Saha
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .