Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAdmitted-Finance 1001 B BHAVESHWAR BLDG NO 03 BHAVESHWAR LANE GHATKOPAR EAST MUMBAI 400077 | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | ₹10.4 L | L1 | Admitted-Finance |
| 2 | L2₹11.0 L+₹65,350 (6.30%)Admitted-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹11.0 L+₹65,350 (6.30%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | EVEREST POWER CONTROL ENGINEERS L1 | sapana enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deep for laying UG cables and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge | 50 | Cum | 195 ₹9,750 Lowest | 195 ₹9,750 Lowest |
| 2.00 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any soil all as specified and as directed by Engineer-in-Charge. | 45 | Cum | 55 ₹2,475 Lowest | 55 ₹2,475 Lowest |
| 3.00 | Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge | 5 | Cum | 65 ₹325 Lowest | 65 ₹325 Lowest |
| 4.00 | Disconnecting/ dismantling in position and carryout minor servicing of 11 KV distribution transformer of capacity from 400 KVA to 750 KVA for any type of leakage defect at LT/HT bushing, gasket, drain plug etc. after disconnecting of electrical supply and earth connection, drain out transformer oil and keeping in close containers for re-use, lifting/ removing of top cover of transformer, reassembling of transformer with new gasket set assembly, replacement of consumer oil tank, nuts, bolts & washers, as required at site, refilling of transformer oil on heated , complete after electric connections and testing on completion complete all as specified and as directed. (Note: (i) If retrieved transformer oil's di-electric strength is less than the desired level than it will be replaced with new one in relevant items of schedule. (ii) If any minor items is required for smooth functioning of transformer including general cleaning of equipment, the cost of the same will be deemed to be included in the unit rates. (iii) HT/LT bushing will be measured and paid separately. (iv) Gasket set shall be measured and paid separately under relevant item of schedule). | 2 | Job | 12,500 ₹25,000 Lowest | 15,000 ₹30,000 |
| 5.00 | Material & Labour for TOP Up ( topping) insulating oil for transformer conforming to IS-3356 at different Transformers & different locations complete all as specified and directed by Engr-in-Charge. | 800 | Ltrs | 210 ₹1,68,000 Lowest | 210 ₹1,68,000 Lowest |
| 6.00 | Earthing for lightening conductor complete with GI earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (Earth pit not less then 2.25m deep below ground level ) with top edge not less than 1.5m below ground level connected to GI earth strip 32 x 6 mm by means of GI bolts,nuts, check nuts,washers & GI strip, protected by 50 mm bore medium grade GI pipe up to 7,5mtr distace including necessary charcol, salt & 20Kg Benzonite powder Funnel with wire mesh , watering pipe20mm dia medium grade excavation earth work PCC (1:3:6) type C-1 earth chamber , 50mm thick RCC cover with 6mm nominal reinforcement etc complete all as shown electrical plate No. 5 of MES schedule part I all as specified and directed. | 10 | Each | 5,000 ₹50,000 Lowest | 5,000 ₹50,000 Lowest |
| 7.00 | M&L for replacement of breather assembly transparent MS body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia or as per site requirement/ capacity of Transformer up to 750 KVA including taking down UNSV breather assembly complete all as specified & directed by the Engr-in-Charge. | 3 | Each | 1,850 ₹5,550 Lowest | 2,200 ₹6,600 |
| 8.00 | Supply and fix Transformer Gaskets and seals made from a blend of nitrile rubber and cork complete for capacity 400KVA to 750KVA transformer including taking down UNSV gasket complete all as specified & directed by the Engr-in-Charge. | 1 | Each | 2,500 ₹2,500 Lowest | 2,500 ₹2,500 Lowest |
| 9.00 | M & L for finding cable fault with electronic fault detector in LT/HT UG cable of any size ranging from 25 to 400 Sqmm 3/ 3.5 core, complete including necessary earthwork all as specified and directed by Engineer-in-charge. | 1 | Job | 9,500 ₹9,500 Lowest | 9,500 ₹9,500 Lowest |
| 10.00 | Supply & fix in repairs gate valve (Gun metal), ISI marked of size 25mm including taking down old UNSV gate valve complete all as specified and directed by Engr-in-Charge. | 2 | Each | 450 ₹900 Lowest | 450 ₹900 Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
22 Aug 2026, 6:00 pmClosed
Shri Vinay Kumar, IDSE, SE (SAG), CWE
HQ Commander Works Engineer (Army) Mumbai, 24 Assaye Building Colaba, Mumbai-05
MAINTENANCE AND UPKEEP OF HT DISTRIBUTION SYSTEM, TRANSFORMER AND ALLIED WORKS AT DGQA GHATKOPAR AND VIKHROLI UNDER GE(N) MUMBAI
2026_MES_779670_1
85330/N/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
North Santacruz
As per NIT and tender documents
8 documents required · 8 mandatory
₹500
Yes
GE NORTH SANTACRUZ
₹20,000
Yes
31 Aug 2026
20 Jul 2026
24 Aug 2026
20 Jul 2026
22 Aug 2026
3 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.0 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deep for laying UG cables and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge | 50 | Cum | - | - |
| 0.0 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any soil all as specified and as directed by Engineer-in-Charge. | 45 | Cum | - | - |
| 0.0 | Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge | 5 | Cum | - | - |
| 0.0 | Disconnecting/ dismantling in position and carryout minor servicing of 11 KV distribution transformer of capacity from 400 KVA to 750 KVA for any type of leakage defect at LT/HT bushing, gasket, drain plug etc. after disconnecting of electrical supply and earth connection, drain out transformer oil and keeping in close containers for re-use, lifting/ removing of top cover of transformer, reassembling of transformer with new gasket set assembly, replacement of consumer oil tank, nuts, bolts & washers, as required at site, refilling of transformer oil on heated , complete after electric connections and testing on completion complete all as specified and as directed. (Note: (i) If retrieved transformer oil's di-electric strength is less than the desired level than it will be replaced with new one in relevant items of schedule. (ii) If any minor items is required for smooth functioning of transformer including general cleaning of equipment, the cost of the same will be deemed to be included in the unit rates. (iii) HT/LT bushing will be measured and paid separately. (iv) Gasket set shall be measured and paid separately under relevant item of schedule). | 2 | Job | - | - |
| 0.0 | Material & Labour for TOP Up ( topping) insulating oil for transformer conforming to IS-3356 at different Transformers & different locations complete all as specified and directed by Engr-in-Charge. | 800 | Ltrs | - | - |
| 0.0 | Earthing for lightening conductor complete with GI earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (Earth pit not less then 2.25m deep below ground level ) with top edge not less than 1.5m below ground level connected to GI earth strip 32 x 6 mm by means of GI bolts,nuts, check nuts,washers & GI strip, protected by 50 mm bore medium grade GI pipe up to 7,5mtr distace including necessary charcol, salt & 20Kg Benzonite powder Funnel with wire mesh , watering pipe20mm dia medium grade excavation earth work PCC (1:3:6) type C-1 earth chamber , 50mm thick RCC cover with 6mm nominal reinforcement etc complete all as shown electrical plate No. 5 of MES schedule part I all as specified and directed. | 10 | Each | - | - |
| 0.0 | M&L for replacement of breather assembly transparent MS body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia or as per site requirement/ capacity of Transformer up to 750 KVA including taking down UNSV breather assembly complete all as specified & directed by the Engr-in-Charge. | 3 | Each | - | - |
| 0.0 | Supply and fix Transformer Gaskets and seals made from a blend of nitrile rubber and cork complete for capacity 400KVA to 750KVA transformer including taking down UNSV gasket complete all as specified & directed by the Engr-in-Charge. | 1 | Each | - | - |
| 0.0 | M & L for finding cable fault with electronic fault detector in LT/HT UG cable of any size ranging from 25 to 400 Sqmm 3/ 3.5 core, complete including necessary earthwork all as specified and directed by Engineer-in-charge. | 1 | Job | - | - |
| 0.0 | Supply & fix in repairs gate valve (Gun metal), ISI marked of size 25mm including taking down old UNSV gate valve complete all as specified and directed by Engr-in-Charge. | 2 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tenderdocuments85330.pdf
Tender Documents • 1.42 MB
BOQ_873287.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .