| 1 | L1₹31.6 LAccepted-AOC 11 97 SADALATLIGUDA CHOWDARIGUDA HYDERABAD TELANGANA 500088 | MEDCHAL MALKAJGIRI | TELANGANA | 500088 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹34.0 L+₹1.1 L (3.22%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
29 May 2023, 6:00 pmClosed
GE I R AND D GIRINAGAR PUNE 411025
GE I R AND D GIRINAGAR PUNE 411025
REPAIR REPLACEMENT TO CI GI DI PIPE LINE PUMPS SETS SLUICE NON RETURN VALVES AND CLEANING OF JACK WELL SUMPS AND ETC AND CERTAIN ALLIED WORKS AT DIAT DU AND MILIT GIRINAGAR PUNE 25
2023_MES_593197_1
GE I R AND D GIRINAGR TOKEN 06 OF 2023 2024
Open Tender
Civil Works
Works
270 days
GE I R AND D GIRINAGAR PUNE 411025
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE I R AND D GIRINAGAR PUNE 411025
₹70,000
Yes
1 Nov 2023
4 May 2023
31 May 2023
4 May 2023
29 May 2023
11 May 2023
4 May 2023 - 8 May 2023
Amount
Taking out the unserviceable submersible pump set alongwith motor including dismantling of flanged MS pipes 150/100 mm dia, taking out from Jackwell and transport to work shop and bringing back after carrying out repairs, overhauling of motor complete, reinstallation the same in Jackwell including assemble with pump alongwith MS pipe 150/100 mm dia including replacement of unserviceable bolts, nuts and rubber gassket insertion for flange joints for the following capacity of pumps & moters all as specified & directed. (a) 75 HP submersible pump alongwith 75 HP motor. Note:- Repair, overhauling, rewinding work will be paid seperately.
All as per item No. 1.00 above but for 20 HP submersible pump alongwith 20 HP motor..
All as per item No. 1.00 above but for 30 HP submersible pump alongwith 30 HP motor.
Repairs to motor 75 HP of submersible pump sets , 75 HP, 3 phase, 415 volts, 50 HZ installed at Jack well pump house in Khadakwasla Dam comprising of following works all as specified & directed. Make :- KSB Dismantling the motor complete for repair/replacing the following spares:- (i)Opening up and dismantling the old burnt out unserviceable winding and rewinding with PVC insulated copper wire of suitable sizes as per manufacturers standard. (ii) Rotor sleeves, turning, grinding and blancing including lath work and painting the body with one coat of primer and two coats of synthetic enamel paint after assembling the motor set – 01 Job Note :-Spares will be measured and paid separately under relevant items.
All as per item No. 4.00 above but for 20 Hp motor of 20 HP submersible pump.
All as per item No. 4.00 above but for 30 Hp motor of 30 HP submersible pump.
Repairs to submersible pump sets 75 HP, 5 stage, , capacity 120 cubic meter per hour at 108 meter head, 3 phase, 400 volts, 50 HZ installed at Jack well pump house in Khadakwasla Dam comprising of following works all as specified and directed. Make :- KSB Dismantling the Pump complete for repair/replacing the following spares:- (i) Opening up and dismantling the old pump unserviceable diffuser, impeller and casting handling diffuser of 75 HP pump as per manufacturers standard. (ii) Replace old unserviceable impeller wih new serviceable 75 HP pump shaft GM impeller as per manufacturers standard. (iii) Rotor sleeves, turning, grinding and blancing including lath work and painting the body with one coat of primer and applying two coats of synthetic enamel paint after assembling the pump set – 01 Job Note :-Spares will be measured and paid separately under relevant items.
All as per item No. 7.00 above but for 20 Hp submersible pump
All as per item No. 7.00 above but for 30 Hp submersible pump
Repairs , maint and servicing of pump motor set at defferent location carry out greasing, oiling replacement of gasket warn out unserviceable nuts, bolts and washers checking of electrical connections with motor and LT panel, Replacement of defective unserviceable part such bearings, impellar, footvalves, pump shafts. power conductor & water level control etc to the following capacities of pump motor sets installed at DIAT all as directed by Engineer-in-Charge. Note : Spare such as bearing impellar, footvalves, pump shafts, power conductor & water level control etc will be measured and paid under relevant items. (a) Monoblock pump sets 5 HP at ABC Block.
(b) All as per item No.10.00 above but for Monoblock pump sets 7.5 HP at filter house & new multi story.
(c) All as per item No. 10.00 above but for Monoblock pump sets 15/20 HP at Near NGO Hostel and point mess.
Taking down Monobloc pump set including dismandling of suction and delivery pipes, power supply , transport to work shop and brought back after carrying out repairs complete , reinstallation of the same including connecting up suction and delivery pipes ,cable connections for following repaires :- (a) Opening up AC induction motor and dismandling startor winding cleaning of core and rewinding with copper enamelled wire of appropriate size and gauge , varnishing , ovening , testing , complete assembled including overhauling pump set by replacing complete assembling & testing all as directed . Note:- Spares will be measured and paid separately under relevant items. (a) Mono block pump set 5 to 7.5 HP
(b) All as per item No. 11.00 above but for Mono block pump set 15 /20 HP
(c) All as per item No. 11.00 above but for Mono block pump set 3 HP at officer mess.
Taking down Nonclog submersible pump set 5HP including dismandling of suction and delivery pipes, power supply , transport to work shop and brought back after carrying out repairs complete , reinstallation of the same including connecting up suction and delivery pipes ,cable connections for following repaires :- (a) Opening up AC induction motor and dismandling startor winding cleaning of core and rewinding with copper enamelled wire of appropriate size and gauge , varnishing , ovening , testing , complete assembled including overhauling pump set by replacing complete assembling & testing all as directed. Note :-Spares will be measured and paid separately under relevant items.
Dismantaling of existing main squirrel cage induction motor pump set by uncruwing/cutting nut bolts,cable connections ,earth connectinons and trasportation to workshop for periodical maintenance /servicing of motor pump set including varnishing of winding with graded varnish ,heating of winding in oven at specified tempreture and dehydrate the winding complete.greasing of bearing and bushing ,scraping of old paint ,prepairing the surface by using redoxide primer and paiting of motor as per colour code and mark the MES/SM number.Split opening of pump ,checking of bearing /busing impellers ,greasing of bearing /busing ,empellar replace whether required as existed and assembling complete motor pump set by replacement of nut bolts gland packing ,papper packing ,etc. and testing complete up to the entire satishfaction of Engr in charge. (a) squirrel cage induction motor pump 15 HP (Location At Point hostel)
(b) squirrel cage induction motor pump 5 KW (Location At Point hostel)
Supply only pump shaft including couppling & bushing for monobloc pump set of following capacity:- a) Pump set 5 HP capacity
b) Pump set 7.5 HP capacity
c) Pump set 15/20 HP capacity
Supply only water seal suitable for following pumps :- a) 2 HP to 7.5 HP
b) 15 HP to 30 HP
Supply only front and rear bearings for induction motor and centrifugal pump as per existing for the following capacities:- a) 5 HP bearing No SKF 6308ZZ or equivalent
b) 7.5 HP bearing No SKF 6310ZZ or equivalent
c) 15 / 20 HP bearing No SKF 6313ZZ or equivalent
a) Supply only bush for 75 HP submersible pump sets.
b) Supply only bush for 30 HP submersible pump sets.
c) Supply only bush for 20 HP submersible pump sets.
d) Supply only bush for 7.5 HP submersible pump sets
a) Supply only strainer for 75 HP submersible pump sets.
b) Supply only strainer for 30 HP submersible pump sets.
c) Supply only strainer for 20 HP submersible pump sets.
d) Supply only strainer for 7.5 HP submersible pump sets.
a) Supply only sand guard for 75 HP submersible pump sets.
b) Supply only sand guard for 30 HP submersible pump sets.
c) Supply only sand guard for 20 HP submersible pump sets.
a) Supply only steel bush for 75 HP submersible pump sets.
b) Supply only steel bush for 30 HP submersible pump sets.
c) Supply only steel bush for 20 HP submersible pump sets.
a) Supply only GM impeller 75 HP submersible pump sets.
b) Supply only GM impeller 30 HP submersible pump sets.
c) Supply only GM impeller 20 HP submersible pump sets.
d)Supply only GM impeller for 7.5 HP submersible pump sets
a) Supply only thrust bearing 75 HP sumersible pump sets.
b) Supply only thrust bearing 30 HP sumersible pump sets.
c) Supply only thrust bearing 20 HP sumersible pump sets.
a) Supply only thrust plate required for 75 HP.
b) Supply only thrust plate required for 30 HP.
c) Supply only thrust plate required for 20 HP.
Supply & fix in replacement of power contactor suitable for starter 3 phase AC 440 volts 50Hz ML 2 for heavy duty of front capacity 32 Amp Make : L&T SS90701 or equivalent in specified makes.
Supply & fix in replacement of power contactor suitable for starter 3 phase AC 440 volts 50Hz ML 1.5 for heavy duty of front capacity 20 Amp Make : L&T or equivalent in specified makes.
Supply & fix in replacement of power contactor suitable for starter 3 phase AC 440 volts 50Hz ML 1 for heavy duty of front capacity 10 Amp Make : L&T or equivalent in specified makes.
Supply & fix in replacement of power contactor suitable for starter 3 phase AC 440 volts 50Hz ML 3 for heavy duty of front capacity 45 Amp Make : L&T SS90721 or equivalent in specified makes.
Supply and fixing fully automatic details delta starter 75 HP, ML 6 FASD, relay max range 66-110Amp, AC1 125A, AC3 110 A, coil voltage 380 V; maximum submersible pump rating at 3 phase, 415 V, 50 Hz all as specified and directed by EIC. Make L&T CAT No. SS90923 at Jack Well pump house.
Supply and fixing L&T FASD STARTER ML1,relay max range 6 - 10A , 10 HP, 3 Phase, coil voltage 380 V; maximum submersible pump rating at 3 phase, 415 V, 50 Hz all as specified & directed by EIC. Make L&T at Jack Well pump house no. 2. and directed by engineer-in-Charge.
Supply and fixing L&T FASD STARTER ,relay max range 20 - 32A, 20HP, 3 Phase, ML2 FASD*, CAT No. SS90705 , coil voltage 380 V maximum submersible pump rating at 3 phase, 415 V, 50 Hz at Jackwell ,khadakwasla Dam all as specified and directed by Engineer-in-Charge.
Supply and fixing FASD STARTER, Relay Max. Range 14-20 Amp , 30HP, 3 Phase, MN25, coil voltage 380 V; maximum submersible pump ratimg at 3 phase, 415 V, 50 Hz at sewage pump house No.1 & sewage pump house No. 2 all as specified & directed. Make L&T CAT No SS94364 or equivalant in specified makes.
Supply and fixing L&T FASD STARTER ,relay max range 45 - 75A, 20 HP, 3 Phase, ML4 FASD*, CAT No. SS90913 , coil voltage 380 V maximum submersible pump rating at 3 phase, 415 V, 50 Hz at Jackwell ,khadakwasla Dam all as specified and directed by engineer-in-Charge.
Supply and replace the defective single phase preventor suitable for 20 HP /7.5 HP pump setsall as specified & directed. Make : L&T/ Minilec
Supply and replace the defective single phase preventor suitable for 75 HP pump sets at Jackwell all as specified & directed. Make:- PowerTek Type:- MPU 501
Supply and replace the defective single phase preventor suitable for 75 HP pump sets at Jackwell all as specified & directed. Make:- PowerTek Type:- MPU 506
M&L for dewatering & Cleaning of the under ground sump for fresh water (sedimentation tank) of 1.5 lakhs gallon capacity semi- under ground and removing accumulated silt / sludge from bottom of sump (Approx 20-30 cm thick) along with foreign materials including dewatering of the sump well complete and removing to a distance exceeding 50 m but not exc. 100m including cleaning and watering rubbing with coir brush for walls and bottom of the reservoir with fresh water by adding bleaching powder for disinfection ( approximate area not exc. 450 Sqm), clean the all valve pit chamber by removing mud dust internally and remove grass/vegetation up to 30 cm all side of valves pit chamber. clean valves and chamber cover and apply one coat of red enamal paint to the cover and black enamel paint over valves body marks with white paint and including white washing with one coat of lime and painting the date of cleaning, due date of cleaning and capacity of tank and repair to the water tank etc complete all as specified and as directed at filteration plant DIAT (DU) Girinagar, Pune - 25.
All as per item No 36.00 above but for fresh water (storage tank) of 1.0 lakh gallon capacity at filteration plant DIAT (DU) Girinagar, Pune - 25.
All as per item No 36.00 above but for raw water (service reservoir) of 30000 gallon capacity (approxmiate area not exc. 150 Sqm) near bungalow No. P-1, DIAT (DU) Girinagar, Pune - 25.
All as per item No 36.00 above but of capacity 50,000 Gallons (approximate area 225 Sqm) at power house, DIAT (DU) Girinagar, Pune - 25.
All as per item No 36.00 above but of capacity 15,000 gallon (approximate area not exc 70 Sqm) at ABC block, DIAT (DU) Girinagar, Pune - 25.
All as per item No 36.00 above but of capacity 15,000 gallon (approximate area not exc 100 Sqm) at Pump House for POINTS hostel, DIAT (DU) Girinagar, Pune - 25.
All as per item No 36.00 above but of 50,000 gallon capacity at New Multi Storey, DIAT (DU) Girinagar, Pune - 25.
Cleaning of Jackwell of size 7.5 m dia 11 m depth removing the sludge/silt 1.5 m from the bottom of the well through sludge pumps and manual lifting cleaning complete all as specified and as directed. Note: - This rate quoted deemed to include the cost of T&P utilized for cleaning. Cleaning will be carried out without disturbing water supply. Timing duration of cleaning will be directed by concerned JE & Engr-in-charge.
Dismantling the existing unserviceable under mentioned sluice valve from the existing pipe line and S&F sluice valve CI body ISI marked high pressure class PN 1.6 heavy duty with flanged ends cast iron wheel with SS spindle (ISI marked) conforming to IS:14846-2000, short body all as specified including nuts,washers and gasket all as directed by Engineer-in-Charge. Make : Kirloskar/ Upadyaya/Kartar. a) Size 80mm dia Bore (Location: Main bldg - 2 Nos., Points mess 01 Nos. & New Multi 01 No.)
b) Size 100mm dia Bore
c) Size 150mm dia Bore
d) Size 200mm dia Bore
e) Size 250 mm dia Bore
f) Size 350 mm dia Bore
Supply only alumn ferric grade-I for drinking water treatment all as specified & directed by Engr-in-charge. Note : This item shall be procured and supplied only after the confirmation of EIC. Total CA Qty shall not be be supplied in one lot for shelf life reason of the chemicals.
M & L for Drilling and tapping CI/GI water mains (in position) for branch connections of the internal dia 15mm, including provn of connecting screw all as specified & directed.
M & L for Drilling and tapping CI/GI water mains (in position) for branch connections of the internal dia 20mm, including provn of connecting screw all as specified & directed.
Taking up damaged / broken Cast Iron water main (including all fitting) with spigot and socket ends and lead joints including burning out joints and recovering lead etc for:-
(a) 80 mm dia
(b) 100 mm bore
(c )150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 mm bore
Material and labour for cast iron pipes with spigot and socket ends centrifugally cast class 'LA' in any required length laid in trenches for :- (a) 80 mm bore
(b) 100 mm bore
(c )150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 mm bore Note for Item No 49.00 (a) to (f):- CI specials and fittings, run lead joints, excavation will be measured and paid separately under relevant items
Taking out the unserviceable lead joints including spun yan and M&L for run lead joint for spigot and socket pipes and fittings of following sizes :- (a) 80 mm bore
(b) 100 mm bore
(c ) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 mm bore
M & L for cutting the existing cracked CI / DI pipe line and M&L for fixing of mechanical joint made of CI / MS incl with tyton rubber ring , nut, bolts / stud , washer etc complete suitable for following dia pipes all as specified & directed.. (a) 80 mm bore
(b) 100 mm bore
(c ) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 mm bore
M&L for PCC 1:4:8 Type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete all as specified and directed by Engineer-in charge.
M&L for pre-cast cement concrete block masonary with solid blocks Type C1(1:3:6) exc.10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
Cleaning of strainer / filter 250/300 mm dia by opening all nut bolts and refixing it properely all as specified and directed. Note: Necessary valve required to close before opening of stainer and after cleaning open the valve is included in quoted rate.
Surface Dressing n.exc 15 cm deep and getting out green vegetation, roots etc around pump house/ OHT / 2 Pole/4Pole structure etc as directed by Engineer-in-charge.
M & L for rendering 15 mm thick in cm 1:4 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement all as specified & directed.
M & L for applying two coats of white wash on new surfaces including preparation of surfaces all as specified and directed by Engineer-in-charge.
Supply & replace existing unserviceable electronic water level indicator in 10 levels with all accessories as required for UG reservior of 25 mtr depth including 12 core PVC insulator copper cable size 0.5 mm dia of each core complete all as specified & directed.
Taking down the defective motor 01 HP by discoonnecting electrically and mechanically and transport to workshop, dismantling the motor, removal of burnt out winding, cleaning the all slot with CTC solution. Rewinding motor with supper enamelled copper winding wire of same gauge as existing. Providing paper insulation of class 'F' and fire proof sleeves warnishing the complete winding and dried the warnish by tight heat process. Reassembling the motor greasing, oiling and painting with single coat of synthetic enamelled paint of existing colour including replacement of both the bearing. Retransportation the motor from workshop to site. Installation at foundation connecting motor electrically / mechanically and testing all as specified and directed by Engr-in-Charge.
S&F Underwater Pond Spotlight Low Voltage Fountain Lighting LED 12V 3W Waterproof IP68 Stainless Steel Underwater Lighting for Fountain all as specified and directed by Engr-in-charge.
Supply and replace existing defective Electronic timer for star delta starters (3 to 30 sec) 220V, GT 200 all as specified and directed. Make : L & T or equivalent in specified makes.
Supply and replace existing defective thermal over load relay ML 2 / 3 (9m-14 to 28-42A) all as specified and directed. Make : L & T or equivalent in specified makes.
Supply and replace existing defective thermal over load 28-42 amps range all as specified and directed. Make : L & T or equivalent in specified makes.
Supply and replace existing defective single function voltmeter 3 phase digital type (0 to 500) all as specified and directed. Make : Schneider/C&S/L&T or equivalent in specified makes.
Supply and replace existing defective phase indication lamps in panel at pump house or equivalent in specified makes.
Supply and fix water pressure gauge along with stop cock of same size, necessary GI fittings and making hole at new place if required on GI/MS/CI pipe at places directed by Engineer-in-Charge. Make- FEIBIG or equivalent in specified makes.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in soft loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in hard dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Taking up or down steel tubing & connections in trenches, wall / floor including cleaning for removal to store of following size:- (a) 80 mm bore pipe
(b) 50 mm bore pipe
(c ) 40 mm bore pipe
(d) 25 mm bore pipe
(e) 20 mm bore pipe
(f) 15 mm bore pipe Note for item no 72.00 (a) to (f): Excavation & earth work shall be measured & paid separately.
Supply and laying tubes, Galvanised,"medium " grade, with all fittings (i.e. bend, elbow, reducer, nipples, union, socket, flange & all required at site) and fixed to walls, ceiling or laying in floors,trenches all as specified for following size:- (a) 80 mm bore pipe
(b) 50 mm bore pipe
(c ) 40 mm bore pipe
(d) 25 mm bore pipe
(e) 20 mm bore pipe
(f) 15 mm bore pipe
Supply & fixing Gun metal gate /globe valve ISI marked with iron wheel head ,screwed both ends for iron pipe including taking up or down unserviceable Gun metal globe /gate valve of following size:- (a) 80 mm bore pipe
(b) 50 mm bore pipe
(c ) 40 mm bore pipe
(d) 25 mm bore pipe
(e) 20 mm bore pipe
(f) 15 mm bore pipe
Supply & fix in repairs cast iron bends (any radius and angle) tappers any type (Straight, Bend, increasing, decreasing or double socket). Tee pieces single branch. "Y" junction, double bernach, cross (all socket or socket spigot) collars, caps, caps & plugs for 80mm to 200 mm dia cast iron pipes with spigot and sockets end all as specified and directed.
Supply & fix in repairs cast iron bends (any radius and angle) tappers any type (Straight, Bend, increasing, decreasing or double socket). Tee pieces single branch. "Y" junction, double bernach, cross (all socket or socket spigot) collars, caps, caps & plugs for 200 mm to 300 mm dia cast iron pipes with spigot and sockets end all as specified and directed.
M & L PCC 1:2:4 type B2 for drain wall make good the damage surface & floor road etc complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:4 on fair faces of brick work or concrete surface of valve pit chamber etc complete all as specified and directed.
M & L for valve pit chamber internal dimension of 900mm x 900mm x 900mm built in brick masonry in cement mortar (1:6) including base concrete PCC (1:4:8) mixed type D2 100mm thick. Plastering to brick work in cement mortor 1:6. 15mm thick internally and externally including provision of 3.15mm thick MS sheet cover fixed with angle iron frame of size 50mm x 50mm x 6mm abandon in PCC 1:2:4 mixed type B-1 including coping of 100mm thick with PCC 1:3:6 type C2, painting to steel and iron work two coat of synthetic enamel paint over one coat of red oxide of primer necessary earth work and excavtion in any type of soil complete with locking arrangement all as specified. Inclusive of dismantling of existing damage valve pit chamber and disposed of the retrieved material all as per directed by Engineer-in-Charge.
Supply and fix in replacment of damaged rubber or fibre board gaskets for flanged joints of following size of pipes: (a) 80 mm dia
(b) 100 mm bore
(c ) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 mm bore
Dismantling the unserviceable sluice valve and Repair / servicing by opening stuffing box, MS Nut, Bolts etc. for replacement and repairing of spindle, check nut etc and reassembling repaired sluice valve and making functional and refixing the same including replacement of Gasket, Gland Packing etc of following size a) size 300/350 mm
b) size 200/250 mm
c) size 100/150 mm
d) size 80 mm Note for item No 81.00 (a) to (d) :- Parts of the sluice valve shall be measured and paid for seperately under relevant items . However unit rate is deem to be included for replacement of rubber gaskets, gland packing of required size and replacement of unserviceable nuts, bolts and washers.
Supply and fix stainless steel spindle with check nut / Hub nut (Gun Metal) and collars suitable for existing sluice valve of following size of any make complete all as specified and directed by Engineer-in-charge. a) 300 mm
Supply only of following items :- (a) Glands rope for packing.(6 mm to 18 mm)
(b) Lead Wool
Supply and replacement of male, female coupling (valve caps) made out of cast iron body and mounted on sluice valves for operating spindle of sluice valves of sizes from 100mm to 350mm dia all as per directed by Engineer-in-Charge..
Supply and fixing of sluice valve operating rod made out of 30mm dia solid MS rod once side duly welded with female copling of sluice valve. Note : Sluice valve female coupling will be supplied under relevant item of this schedule all as per directed by Engineer-in-Charge..
S & F GI pipe fittings of size as Bends from 15 mm bore to 80 mm bore (any type, radius and angle), tapers any type, (straight, bend, increasing, decreasing or double socket etc.), GI Tee pieces single branch. "Y" junction, double branch,GI elbows of any size,GI hex nipples of any size,GI Tee reducer of any size, cross (all GI sockets or socket and spigot), GI Unioun of any size, GI collars of any size, GI caps of any size, GI plugs of any size, GI Barrels of any size all as specified and directed by Engr-in-charge.
S&F Chain pulley block 3 Ton capacity for Jackwell near E/M installation khadakwasla Dam all as directed by Engineer-in-Charge.
Supply only granular / powder based calcium hypochlorite having 60% to 70% available chlorine packed in 40-45 kg plastic drums for water treatment chemical each all as specified and directed by Engineer-in-charge.
Supply only Water Quality Testing kit (chlorine and PH verifier test kit for water) all as per directed by Engineer-in-Charge.
Supply & fix of submersible flat 3 core copper conductor cable 10 Sqmm suitable for 20 HP submersible pump all as specified and directed.
Supply & fix of submersible flat 3 core copper conductor cable 25 Sqmm suitable for 75 HP submersible pump all as per directed by Engineer-in-Charge.
Opening & cleaning of existing Flanged / spigot socket joint/lead joint of CI Pipes for finding reason for leakage including required excavation of earth work, pump required to drain out water during work, closing the required valve for stopping water and open after completion of work all as specified and directed by Engineer-in-Charge for following sizes of CI Pipes :- Note : All T&P shall be arranged by the contractor. Unit rate shall deem to be included for the same and no extra claim shall be entertained by the department on this account. a) Bore of CI Pipe 250mm
b) Bore of CI Pipe 200mm
c) Bore of CI Pipe 150mm
d) Bore of CI Pipe 100mm
e) Bore of CI Pipe 80mm
S & F MS black nuts, bolts, washers of different sizes as directed by Engr-in-Charge
Rectifying the defects such as complaint of no water / water blockage, Repair to sluice valve such as replacement of gland packing / removal of blockage, Repair to leakage in pipe line including digging trenches required for rectification of leakage, arrest minor leakage by tigtning pipe accessorie etc. in entire Residential/Technical area (DIAt & MILIt) all as directed by Engineer-in-Charge. Note :- (i) The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the water line functional. If replacement of parts/items is required to make the water line functional, the cost for labour and material for the same will be measured and paid for as "S&F in repairs" under relevant items of this schedule hereinbefore and in such cases, this items will not be measured and paid for. (ii) The contractor will deploy minimum One Plumber and one helper from 0900 Hrs to 1700 Hrs. (iii) Plumber and helper shall be employed all working days incl Sundays and holidays and they will report to dept at 0900 Hrs at AGE E/M office. (iv) The unit rate quoted by the contractor shall be inclusive of working & attending the complaints as directed by Engr-in-charge.(v) The Plumber who is on duty must be provided with common mobile cell to facilitate and render good services to the users and the same shall be deemed to be included in the unit rate. (vi) Complaint slip to be collected daily from complaint cell/AGE E/M Girinagar & Dighi office and same shall be returned on completion of job.(vii) Contractor shall provide protective devises and all tools required for attending complaint with proper tool bag and the same shall be deemed to be included in the unit rate. (viii) If individual remains absent on site, contractor shall make an alternative arrangement.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/ trenches including all required fittings such as elbows, sockets, reducers,union etc in trenches complete all as specified for the following outer dia. (a) 15 mm dia
(b)20 mm dia
(c)25 mm dia
(d)40 mm dia
Supply, fix, installation, testing & commissioning complete set of motor soft starter 3 phase AC 440 volts 50Hz 90 KW 171A PSTX170-600-70 for 75 HP motor of submersible pump 5 stage of capacity 120 cubic meter per hour at 108 meter head, 3 phase, 400 volts, 50 HZ installed at Jack well pump house in Khadakwasla Dam in Jackwell. Make :ABB / L&T or equivalent in specified makes
Supply only Fresh Quartz sand, gravels & pebblels of size 0.45mm to 40 mm and coefficient of uniformity shall be between 1.3 to 1,7 and silica content should not be less than 90% including removal of old filter Bed Media (Gravel & sand ) from Filter Bed of any size not exc. 1.5 mtr in depth as per existing arrangement and as per standard practices as mentioned below within the stipulated time period by employing suitable no. of labour with necessary tool and plant to complete work on or before the stipulated time including cleaning of filter bed media (Gravels only with fresh/clean water till complete removal of tiny dirt deposite on gravel and make it suitable to reuse and proper segmentation Gravels and sand complete & including refilling(Loose) of filter Bed Media (Old Gravel & newly provided quartz sand ) inside filter Bed of any size upto depth as per directed by Engineer-in-charge and as per standard practices as mentioned below within the stipulated time period by employing suitable no. of labour with necessary tool and plant to complete work on or before the stipulated time complete all as directed. Note: Thickness for each layers and laying sequence as per sand size will be directed by concerned JE/ Engr-in-charge.
Suppy & fix Stainless Steel Legrand Wire Mesh Cable Tray of size 100 x 50mm, Hot-Dip Galvanized Coating including required fittings such as nuts, washers, clamps etc all as required and directed.
Supply, installing, testing and commissioning, weather, dust and vermin proof Feeder Piller box factory made, outdoor type of suitable size so as to accommodate the following accesoris, depth not less than 500mm, IP 54 and all as per IE rules, prewired and fabricated with 3.15mm thick CRCA sheet exoxy power coated double door with aprons, duly powder coated mounted on MS angle iron frame 50x50x6mm welded in shape with two coats of synthetic enamel paint over a coat of red oxide primer including necessary grouting in PCC 1:3:6 type C-1 using 20mm (using graded coarse stone aggregates) complete with leg 50cm grounted in ground in PCC at 40cm above ground including connection cable with cable glands, lugs etc and consisting of the following:-
(a) Copper bus bar 800 Amp(04 Nos)- 03 Nos for phase and 01 Nos for neutral duly colour sleeved mounted on epoxy insulator - 01 Set
(b) MCCB 400 Amp, FP, 415V, 50Hz, 36 KA confirming to IS/IEC 60947-2 thermal magnetic adjustable with over load 80-100% & short circuit protection 5-10 In type - 01 Nos (Incoming)
(c) Outgoing
(i) MCCB 160 Amps, FP, 415V, 50Hz, 36 KA confirming to IS/IEC 60947-2 thermal magnetic adjustable with over load 80-100% & short circuit protection 5-10 In type - 02 Nos
(ii) MCCB 63 Amps, FP, 415V, 50Hz, 36 KA confirming to IS/IEC 60947-2 thermal magnetic adjustable with over load 80-100% & short circuit protection 5-10 In type - 02 Nos
(iii) MCB TPN 63 Amp, 10 KA `C' series - 01 Nos.(Security Lights)
(vi) RYB indicator lamp- Set of 3 Note : Panel shall be manufactured by the reputed manufacturer who is in possession of type test certificate by CPRI not older than3 years.
Supply, installing, testing and commissioning, weather, dust and vermin proof Starter Panel factory made, indoor type of suitable size so as to accommodate the following accesoris, depth not less than 500mm, IP 54 and all as per IE rules, prewired and fabricated with 3.00 mm thick CRCA sheet exoxy power coated double door with aprons, duly powder coated mounted on MS angle iron frame 50x50x6mm welded in shape with two coats of synthetic enamel paint over a coat of red oxide primer including necessary grouting in PCC 1:3:6 type C-1 using 20mm graded coarse stone aggregates complete with leg 50cm grounted in ground in PCC at 40cm above ground including connection cable with cable glands, lugs etc and consisting of the following:-
(a) Copper bus bar 375 Amp(04 Nos)- 03 Nos for phase and 01 Nos for neutral duly colour sleeved mounted on epoxy insulator - 01 Set
(b) MCCB 250 Amp, FP, 415V, 50Hz, 36 KA confirming to IS/IEC 60947-2 thermal magnetic adjustable with over load 80-100% & short circuit protection 5-10 In type - 01 Nos (Incoming)
(c) Outgoing
(i) Separate chamber for L&T starter ML 2 for 20 HP motor 3 phase AC 440 volts 50Hz - 05 Nos.(4 W+1 Spare)
(vi) RYB indicator lamp- Set of 3
(vii) Single phase preventor - 03 Nos for 3 phases. Note : Panel shall be manufactured by the reputed manufacturer who is possession of type test certificate by CPRI not older than3 years. Old U/s panel shall be dismantled by contractor & cost there of shall deemed to be included in quoted rate. Old panel shall be contractor's property as per Schedule of credit.
M& L for applying two coats of synthetic enamel paint including preparation of old surfaces complete all as specified and directed on the following items:-
(a) Panels
(b) 200mm to 300 mm CI Pipe
(c) 100 mm CI Pipe
(d) Pumps 2 to 5 HP
(e) Pumps 7.5 to 20 HP
Supply , laying , testing and connecting LT UG cables 1100 Volt grade XLPE insulated and PVC sheathed, armoured, with multi stranded aluminium conductor, heavy duty confirming to IS - 1554 part-I, including cable glands, cable lugs in LT panel/ FP Box etc including material and labour for all jointing/connecting material as required, cables laid in trenches/ducts/under plinth floors passing through pipes etc, for following sizes:
(a) 240 sqmm 3.5 core
(b) 95 sqmm 3.5 core
(c) 35 sqmm 3.5 core
(d) 10 sqmm 4 core
M&L for Calibration of water meter for main raising pipe line from jackwell for following size : (a) Fresh water pipe line 250mm dia
(b) Raw water pipe line 100 mm dia
M&L for White,Black & Natural Anti Bird Net, Packaging Type: Roll, Size: 10 Mtr X 30 Mtr Rolls all as specified and directed.
S& F Mechanical type Mild steel Water Level Indicator for upto 30m depth including required accessories all as specified and directed by Engr-in-charge.
S& F 25 mm DUCTILE IRON SINGLE CHAMBER Compact Air Release Valve including all required accessories all as specified and directed. Make Kartar K 550 or equivalent in Kirloskar/
S& F 50 mm DUCTILE IRON SINGLE CHAMBER Compact Air Release Valve including all required accessories all as specified and directed. Make : Kartar K 549 or equivalent in Kirloskar as approved.
Supplying and laying DWC pipe ( OD - 63mm & ID - 51 mm nominal) ISI marked along with all accessories etc confirming to IS 14930, part II complete with fitting and cutting, jointing etc. in trench/open, for LT UG cable protection as required complete all as specified and directed.
Supply and fix non return valve, both end flanged, CI body of class 1.0 PN including dismantling old u/s non return valve complete all as directed by Eng-in-charge for following sizes: (a) 350 mm dia
(b)200 mm dia
(c) 150 mm dia
(d) 100 mm dia
S& F MS clamp for 6'' pipe for 75 HP Pump at Jackwell all as specified and directed.
S& F MS clamp for 4'' pipe for 20 HP Pump at Jackwell all as specified and directed.
S&F L&T FN 63 Switch Disconnector Fuse, 3 Pole, 63a Ac-23a in place of old unserviceable Switch Disconnector all as specified and directed.
S&F L&T MNX-A1 ADD-ON BL.2NO+2NC 4 Poles Contactor, CS94114OOOO in place of old unserviceable Contactor all as specified and directed.
S&F L&T MNX-A2 ADD-ON BL.2NO in place of old unserviceable Contactor all as specified and directed.
S&F HM TDS-3 Digital TDS Meter all as specified and directed.
sagar construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .