Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.8 L+₹68,405 (2.43%)Rejected-Finance | L2 | Rejected-Finance L2 BIDDER | |
| 3 | L3₹29.2 L+₹1.1 L (4.02%)Rejected-Finance | L3 | Rejected-Finance L3 BIDDER |
| Sl No | Description | Qty | Unit | SAMARESH CHHOTARAY L1 | SATYAJIT SAMANTARAY L3 | PROMOD KUMAR BHUYAN L2 |
|---|---|---|---|---|---|---|
| 1.00 | Racking the Block Joint/ Expansion Joint of size 50 mm wide upto a depth of 50 mm in side the gallery to remove the deteriorated existing system and thoroughly cleaning the surface of the joint to remove all the loose particles by using Air blower & Water jet and sealed by inserting compressible hydrophilic backup material which fits into the groove completely and filling the joint by Polyurethane Sealant followed by fixing of EPDM membrand and Aluminium strip of required size with the help of fasteners to protect the treatment. | 100 | Rmt | 3,845 ₹3,84,500 Lowest | 3,870 ₹3,87,000 | 3,850 ₹3,85,000 |
| 2.00 | Providing & filling sunken floors with Broken Autoclaved Aerated Cement Blocks (AAC Light Weight Bricks) well compacted and top surface dressed and levelled to proper gradient including cost of all labour, cost of sand, royalty, loading, unloading, transportation, sundries, T&P, etc. complete as diected by the Engineer-in-charge but excluding of GST. | 50 | Cum | 5,538 ₹2,76,900 | 5,500 ₹2,75,000 Lowest | 5,550 ₹2,77,500 |
| 3.00 | Providing and fixing sheet covering over expansion joints with iron screws as per designas, directed by the Engineer-in charge.. | 50 | Rmt | 835 ₹41,750 Lowest | 840 ₹42,000 | 850 ₹42,500 |
| 4.00 | Providing and applying "Concrete Waterproofing & Durability Enhancement by Crystallization" to be supported by at least two International Test reports showing clear Scanning Electron Microscopic (SEM) photographs of densified and mature crystals formation to plug all the capillary tracks and pores of the concrete permanently and Permeability test as per IS 2720 conducted by CBRI the concrete Should not absorbed water more than 1.5 gms and not more than 1 mm from the concrete surface. The product to be listed in ICC-ES EVALUATION REPORT INDEX January 2009, 2010 and 2011. The treatment to be carried out on the concrete surfaces including cleaning all RCC surfaces as per manufacturer's specification/ datasheet. The application to be carried out with brush in one coat of 0.80 kg per coat. | 50 | Sqm | 571 ₹28,550 Lowest | 650 ₹32,500 | 600 ₹30,000 |
| 5.00Providing Hilti rebaring with Hilti Chemical of approved make and manufacture including cost of all labour, cost of sand, royalty, loading, unloading, transportation, sundries, T&P, etc. complete as diected by the Engineer-in-charge but excluding of GST. | ||||||
| 6.00 | Dia 20 mm | 50 | Nos | 221 ₹11,050 Lowest | 230 ₹11,500 | 250 ₹12,500 |
| 7.00 | Dia 10 mm | 50 | Nos | 121 ₹6,050 Lowest | 150 ₹7,500 | 150 ₹7,500 |
| 8.00 | Providing and laying 2 mm thick homogeneous PVC Anti Static Vinyl Flooring RQ Restroable quantity (single layer of PVC) with weight 2950g/m² ,PUR (Polyurethane reinforced) , RQ Abrasion group T:≤4.00mm residual indentation approx,0.04 mm caster wheel test qualified,dimentional stability ≤0.04% ,static electrical charge < 2kv good resistance of stratch ,slip,chemical and fire,IMO marine 0575 certified doesnot favor in growth of fungi & bacteria .100% recyclable. VOC emission after 28 days of installation (lower than ≤10 µg /m³ ).The sheet at the corners and floor wall junction shall be laid with PVC cove to avoid sharp joint as per deriction of Engineer-in-charge The joint shall be made seamless with PVC weld rod.Rate inclusive of corner coves and welding C.C. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) including cost , conveyance,loading,unloading,royalties and taxes of all materials,cost of all labour,sundries, T & P required for the work complete in all respect as directed by the Engineer-in-charge. | 50 | Sqm | 3,100 ₹1,55,000 Lowest | 3,130 ₹1,56,500 | 3,200 ₹1,60,000 |
| 9.00 | Providing and fixing fully perforated false ceiling at all heights with integral densified butt edge calcium silicate perforated reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on inter- locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of Engineer-in-Charge(8 mm thick fully perforated calcium silicate board made with Calcareous) | 50 | Sqm | 2,329 ₹1,16,450 Lowest | 2,370 ₹1,18,500 | 2,350 ₹1,17,500 |
| 10.00 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm SPINTONE/COSMOS/HEXA in true horizontal level,suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main ‘T’runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening“for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint,for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
Cleaning of the surface using latest Machine, Tools, and T & P with all safety equipments and necessary arrangements as directed by the Engineer in Charge. Dismantling/removing all loose mortars to expose mother surface. The surface to be free from all contaminants, dust, clays & all other foreign particles. | 100 | Sqm | 1,655 ₹1,65,500 Lowest | 1,670 ₹1,67,000 | 1,700 ₹1,70,000 |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
28 Sept 2020, 5:00 pmClosed
CGM PC
IDCO Tower, Janpath, Bhubaneswar
Waterproofing, false ceiling and other finishing work of. Construction of Different Buildings inside the Electronic Manufacturing Cluster (EMC Park) at Infovalley Khurda. (ascertaining rates only)
2020_IDCO_62613_1
PC/EST/E-33/2020-21
National Competitive Bid
Civil Works - Buildings
Item Rate
Infovalley
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,080
₹25,000
Bhubaneswar
13 Sept 2025
11 Sept 2020
29 Sept 2020
11 Sept 2020
28 Sept 2020
11 Sept 2020
11 Sept 2020 - 16 Sept 2020
16 Sept 2020
Amount
Racking the Block Joint/ Expansion Joint of size 50 mm wide upto a depth of 50 mm in side the gallery to remove the deteriorated existing system and thoroughly cleaning the surface of the joint to remove all the loose particles by using Air blower & Water jet and sealed by inserting compressible hydrophilic backup material which fits into the groove completely and filling the joint by Polyurethane Sealant followed by fixing of EPDM membrand and Aluminium strip of required size with the help of fasteners to protect the treatment.
Providing & filling sunken floors with Broken Autoclaved Aerated Cement Blocks (AAC Light Weight Bricks) well compacted and top surface dressed and levelled to proper gradient including cost of all labour, cost of sand, royalty, loading, unloading, transportation, sundries, T&P, etc. complete as diected by the Engineer-in-charge but excluding of GST.
Providing and fixing sheet covering over expansion joints with iron screws as per designas, directed by the Engineer-in charge..
Providing and applying "Concrete Waterproofing & Durability Enhancement by Crystallization" to be supported by at least two International Test reports showing clear Scanning Electron Microscopic (SEM) photographs of densified and mature crystals formation to plug all the capillary tracks and pores of the concrete permanently and Permeability test as per IS 2720 conducted by CBRI the concrete Should not absorbed water more than 1.5 gms and not more than 1 mm from the concrete surface. The product to be listed in ICC-ES EVALUATION REPORT INDEX January 2009, 2010 and 2011. The treatment to be carried out on the concrete surfaces including cleaning all RCC surfaces as per manufacturer's specification/ datasheet. The application to be carried out with brush in one coat of 0.80 kg per coat.
Providing Hilti rebaring with Hilti Chemical of approved make and manufacture including cost of all labour, cost of sand, royalty, loading, unloading, transportation, sundries, T&P, etc. complete as diected by the Engineer-in-charge but excluding of GST.
Dia 20 mm
Dia 10 mm
Providing and laying 2 mm thick homogeneous PVC Anti Static Vinyl Flooring RQ Restroable quantity (single layer of PVC) with weight 2950g/m² ,PUR (Polyurethane reinforced) , RQ Abrasion group T:≤4.00mm residual indentation approx,0.04 mm caster wheel test qualified,dimentional stability ≤0.04% ,static electrical charge < 2kv good resistance of stratch ,slip,chemical and fire,IMO marine 0575 certified doesnot favor in growth of fungi & bacteria .100% recyclable. VOC emission after 28 days of installation (lower than ≤10 µg /m³ ).The sheet at the corners and floor wall junction shall be laid with PVC cove to avoid sharp joint as per deriction of Engineer-in-charge The joint shall be made seamless with PVC weld rod.Rate inclusive of corner coves and welding C.C. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) including cost , conveyance,loading,unloading,royalties and taxes of all materials,cost of all labour,sundries, T & P required for the work complete in all respect as directed by the Engineer-in-charge.
Providing and fixing fully perforated false ceiling at all heights with integral densified butt edge calcium silicate perforated reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on inter- locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of Engineer-in-Charge(8 mm thick fully perforated calcium silicate board made with Calcareous)
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm SPINTONE/COSMOS/HEXA in true horizontal level,suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main ‘T’runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening“for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint,for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Cleaning of the surface using latest Machine, Tools, and T & P with all safety equipments and necessary arrangements as directed by the Engineer in Charge. Dismantling/removing all loose mortars to expose mother surface. The surface to be free from all contaminants, dust, clays & all other foreign particles.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.including all materials and labour complete as per drawing and direction of Engineer-in-charge.
Supply, Fabrication, Erection and Fixing of GEENLAM/CENTURY Brand or Clades of standard dimension of 1300mm x 3050 of thickness 6mm for fixing used Al. sub structure is made up of Aluminum box sections of 50 x 25 x1.5mm of the section size 50 x 25 x 1.5 mm will be using the vertical joint of the two panels .As per the standard procedures in riveting system Spacing of two verticals should always be maintained at 450 mm. Aluminum/ms brackets are of two types .Wind load brackets and dead load brackets of size 85 x 50 x5mm the and to be placed in 1500 mm intervals in vertical .wind load brackets will have vertical slot and dead load brackets will have horizontal slots .Thermal separators to be placed between Aluminum brackets and concrete structure. Bimetallic separators to be placed between AL, sub structure and Aluminum brackets, Brackets fixing with nylon fasteners or self-tapping bolts, Aluminum grid frame fixing in between brackets by ss nut and bolts. After framing done the panels fixing started with maintaining 6mm horizontal and vertical gaps between one panels to another, For fixing of panels done by riveting .Rivet distance maintain horizontally 300 mm and vertically 300 mm maximum .First drill hole of the panel for rivet should be maintain 40mm from top and 20mm from side.for proper ventilation providing 20mm gap on top and bottom of the façade for maintaining air circulation including all materials and labour complete as per drawing and direction of Engineer-in-charge.
Providing and fixing 12mm thick tegular edge wooden ceiling of decorative of decorative shade having NRC factor 0.87 of approved texture of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main “T’ runner suitably spaced at joints to get required length and size of 24x38 mm made from 0.33 mm thick (minimum) sheet, 1200mm centre to centre, and cross ‘T’ of size 24x38 mm made out of 0.33 mm (minimum) sheet, 1200 mm long spaced between main ‘T’ at 600mm centre to centre to form a grid of 1200 X 600 mm and secondary cross ‘T’ of length 600mm and size 24X28 mm made out of 0.33 mm thick (Minimum) sheet to be interlocked at the middle of the 1200X600 mm panel to form grid of size 600X600 mm resting on periphery walls/ partitions on a perimeter wall angle pre-coated steel of size (24X24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plug at 450mm centre to centre with 25mm long dry wall screws @230mm interval and laying12mm thick tegular edge wooden ceiling in the grid including cutting/ making opening for services like diffusers, grills, light fitting, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25X35X1.6mm fixed to ceiling with 12.5 mm dia. and 50mm long dash fasteners, 4mm G.I adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200 mm centre to centre long main ‘T’ bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawing and as direct by engineer-in-charge.
Ramco-Hilux, Calcium Silicate Standard false ceiling (8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process).
Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I channels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Raw plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with:
Providing and fixing 12 mm thick frameless Toughened Glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing plywood 4 mm thick, both side decorative Silicon Romantic Veneer conforming including flush doorto IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with :all complete as per drawings, specification and direction of the Engineer in charge
Providing and fixing glazing in aluminium door, window, ventilator shutters all complete as per direction of Engineer-in-charge and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Providing,fitting and fixing the black out roller blinds for all window and partitions of approved make and shade and inclusive of all cost of labour,materials as per thedetail design & specification. .as per the detail design approved by eic / architect . ( basic price 220/sft ) but excluding GST.
N.B: GST as applicable will be paid extra.
PROMOD KUMAR BHUYAN
SATYAJIT SAMANTARAY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .