| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹23.1 L+₹7.9 L (52.0%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹24.8 L+₹9.6 L (62.9%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹25.5 L+₹10.3 L (67.8%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L4 | Rejected-AOC NOT LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
2 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI 400088
REPAIRS MAINTENANCE OF EXTERNAL WATER SUPPLY LINES AT MANKHURD UNDER GE(NW) MANKHURD
2021_MES_419076_1
8052/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) MANKHURD
AS PER NIT AND TENDER PAGES
9 documents required · 9 mandatory
₹500
Yes
GE (NW) MANKHURD
₹40,000
Yes
12 Mar 2021
4 Feb 2021
4 Mar 2021
4 Feb 2021
2 Mar 2021
18 Feb 2021
4 Feb 2021 - 17 Feb 2021
60 days
Amount
Notes : (i)The contractor should be in possession of valid electrical license to execute electrical works. (ii) Supervisor for execution of electrical works/ electrical component of works employed by the contractor shall possesses supervisor certificate of competency issued by concerned State Government/ Union Territory and the worker/ tradesmen for execution of electrical works/ electrical component of works shall hold necessary permit issued by concerned State Government/ Union Territory. Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc and not exceeding 10sqm on plan and n.exc 1.5m in depth and getting out in soft / loose soil for laying of cables, etc. complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm deep as in soil complete all as specified and as directed.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point as in soil including spreading in low lying area and leveling complete all as specified and as directed.
Cutting the existing road/hard standing/chequered cement concrete tiling/PCC floor etc,. not exceeding 50cm wide, and refilling with excavated material after laying CI/GI pipe line all as specified and as directed.
Taking up or down steel tubing and connections including cleaning and setting aside for refixing or as schedule of credit, etc complete all as specified and as directed for the 20mm bore pipes including necessary staging/scaffolding as required:-.
All as per item No 5.00 above but 25mm bore
All as per item No 5.00 above but 40mm bore
All as per item No 5.00 above but 50mm bore
All as per item No 5.00 above but 80mm bore
All as per item No 5.00 above but 100mm bore
M & L for relaying/fixing old pipe obtained from demolition/taking down including cutting out damaged ends and rethreading for fixing with and including new fitting complete of 25mm bore including necessary staging/scaffolding all as specified and directed
All as per item No 11.00 above but 40mm bore
All as per item No 11.00 above but 50mm bore
All as per item No 11.00 above but 80mm bore
All as per item No 11.00 above but 100mm bore
Supply& Laying fixing, connecting and testing steel water tubing, medium grade, galvanised, with screwed and socketed joints, in any length, including supply and fixing all fittings, fixed to walls or laid in trenches / floors etc complete all as specified and as directed for the 20 mm bore
All as per item No 16.00 above but 25mm bore .
All as per item No 16.00 above but 40mm bore
All as per item No 16.00 above but 50mm bore
All as per item No 16.00 above but 80mm bore
All as per item No 16.00 above but 100mm bore
Supply and fix ISI Marked UPVC Pipe size 50mm nominal dia,pressure pipe schedule 80 with all connected acessories like UPVC bend,Tees,Unions,Sockets etc for each 3 mtr length of Pipe & solvent to join all as specified and as directed.
All as per item No. 22.00 above but of 40mm dia
All as per item No. 22.00 above but of 25 mm dia
S&F in repairs gunmetal gate or globe valve for 50mm dia, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed
All as per item No 25.00 above but 40mm dia
All as per item No 25.00 above but 25mm dia
All as per item No 25.00 above but 20mm dia
Taking out sluice valves of size 80mm to 100mm and refacing, regrinding and refixing to match with standard size and refixing in position including replacing of defective gland packing/washer /nuts/ set screws etc complete all as specified and directed. Note : Rate quoted is inclusive of cost of spare parts.
All as per item No 29.00 above but for size 150mm to 200mm dia
S&F sluice valve 100mm bore, cast iron body, flanged and drilled end, conforming to IS-14846, ISI marked, class PN 1.6 including all joints with rubber or fibre board, gaskets, bolts and nuts, washers, iron wheel including taking up / down old unserviceable valves from any position and any addition / alteration for fixing required complete all as specified and as directed
All as per item No 31.00 above but 150mm bore
All as per item No 31.00 above but 80mm bore
M&L for run lead joints to CI spigot and socket pipes of 80mm bore and fittings including cleaning the joints, re-aligning the pipeline properly as required, cocking and jointing with old pig lead, including any addition / alteration for fixing required, testing pipelines for any leakage , making good any disturbed / damaged pipeline / parts etc, complete all as specified and as directed Note ; Necessary excavation and earthwork will be measured and paid separately
All as per item No 34.00 above but 100mm bore
All as per item No 34.00 above but 150mm bore
S&L cast iron pipes of 80mm bore with spigot and socket ends centrifugally cast, Class LA, confirming to IS suitable for lead joints in any length laid in trenches including taking out old damaged CI main including fitting burning out joints and recovering lead complete etc as specified and directed.
All as per item No 37.00 above but 100mm bore
All as per item No 37.00 above but 150mm bore
All as per item No 37.00 above but 200mm bore
M&L for CI fittings confirming to IS for spigot and socket pipes, upto 150mm bore such as bends, tapers, tee pieces single branch, collars etc.
All as per item No 41.00 above but 200 to 300mm bore.
Supply, installation, testing and commissioning indoor LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC,50 HZ, cubical , dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet duly powder coated painting , CPRI approved, hinged door, front and rear opening with locking arrangement, cable alleys, bus bar chamber and switch gear compartments, copper bus bar 150 Amps rating for three phases and 150 Amps for neutral duly covered with heat shrinkable sleeves colour coded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting MCCBs/switch gears with main bus bar by using copper bus links or copper conductor flexible wires of suitable rating and connecting with terminal blocks of appropriate rating by cable lugs, thimbles etc., earthing terminals, affixing danger notice plate, each compartment shall be numbered/lettered for indication and control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement and a clear space to be kept from bottom of panel for proper termination of cables and including cable connection to MCCBs, switch gears with necessary cable glands, lugs, nuts, bolts and washers etc., complete all as specified and directed including comprising of following:- (a) MCCB 100 Amps (Magnetic thermal setting type), 4 Pole, 25 KA, 415 Volts, AC, 50 HZ -01 No (Incoming) (b) MCCB 32 Amps (Magnetic thermal setting type), 3 Pole, 25 KA - 02 Nos. (Out going) (d) MCB TPN 40 Amps -01 Nos.(Out going) (e) MCB SPN 32 Amps - 02 Nos (f) Star Delta Starter for 7.5 HP Pump- 02 No. (g) Motor protection relay-02 No (h) LED indicator RYB- 03 Nos (j) Time switch with contactor -1 No (k) VAF meter - 1 No Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication and shall be CPRI approved factory fabricated of approved make specified vide Ser No 76 on Page No 115 of CA
Supply and fix display boards of 3 mm thick Acrylic sheet of size 0.50 mtr x 0.4 mtr, showing machine details / specifications of pumpsets all as specified and as directed by Engr-in-charge.
Supply fabricate and fix valve chamber covers made out of suitable size & thickness of MS angle/MS plate/flat/rod, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer including removing existing unserviceable rusted cover all as directed.
Supply and fix in replacement ladder height 10 feet max, steps on every 01 feet made of angle iron of size 50x50x5 mm thick for sump including taking down old rusted iron ladder complete all as specified and directed.
Dismantling existing PVC water storage tanks and Supplying, hoisting and fixing rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) of 500 Litres capacity with and including covers, hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes etc complete all as specified and as directed
All as per item No. 47.00 above but 1000 litres capacity
All as per item No. 47.00 above but 2000 litres capacity
All as per item No. 47.00 above but 3000 litres capacity
Supply and fix in repair 50mm bore PVC Ball valve ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed.
All as per item No. 51.00 above but 40mm bore
All as per item No. 51.00 above but 25mm bore
All as per item No. 51.00 above but 20mm bore
M& L for draining out water complete cleaning & removing accumulated sludge/ dirt, scales from bottom of walls/ ceiling /top of slab and from mouths of circulating pipes of service tanks/ PVC tanks of capacity not exceeding 500 litres, located on roof of bldgs and disinfecting the tank using bleaching powder to make the tank bacteria free and depositing the rubbish in low lying areas of defence land, writing by stencil date of cleaning of tank with white synthetic enamel paint on black ground " cleaned on (date) due on (date) complete all as directed.
All as per item No 55.00 above but capacity of tank exceeding 500 litres but not exceeding 1000 ltrs
All as per item No 55.00 above but capacity of tank exceeding 1000 ltr but not exceeding 2000 litres
M&L for cleaning of balancing tank of swimming pool of capacity 1,00,000 ltrs , from bottom and side walls by scrubbing with wire brush and removing mud deposited/accumulated at the bottom complete all as specified and directed
S&F in repair wooden base brush of size 92cm x 7cm x 4cm suitable for suction sweeper assembly,with nylon hair brush with bristles of length 7cm and 1mm dia each complete all as specified and directed
M&L for petty repair work by replacement of GI fittings such as elbow,socket,tee etc and depositing the complaint slip in complaint cell after user signature complete all as specified and directed
M&L for angle iron, U shape channel of any size as per site requirement, welding to required shape, including all nuts,bolts,washers etc complete all as specified and directed
M&L for PCC foundation filling and mass concrete type B2, 1:2:4 (using 40 mm graded aggregate) as per site requirement,including form work complete all as specified and directed
Supply only OT solution for chlorine test(500ml),complete all as specified and directed.
Supply only phenol red solution for PH test(500ml),complete all as specified and directed. Note : A sum of Rs 67,250.00 towards sch of credit shall be deducated to arrive the contract sum.
Shree Ayyappa Engineering
Radha Engineering Services
cooltech engineering services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .