Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC | ₹2.6 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹2.8 Cr+₹20.0 L (7.70%)Rejected-Finance OLD HASIMARA DISTT JALPAIGURI WEST BENGAL PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | ₹2.8 Cr+₹20.0 L (7.70%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹2.8 Cr+₹22.8 L (8.78%)Rejected-Finance MES CHOWPATHY PO HASIMARA DISTT JALPAIGURI PIN 735215 WB | HASIMARA | JALPAIGURI | WB | 735215 | ₹2.8 Cr+₹22.8 L (8.78%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹2.9 Cr+₹34.2 L (13.1%)Rejected-Finance BHAGWATI BHAWAN PO HASIMARA DIST JALPAIGURI PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹2.9 Cr+₹34.2 L (13.1%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | L5₹3.0 Cr+₹41.5 L (16.0%)Rejected-Finance BANSAL BHAWAN STATION CHARALI AT ROAD SIVASAGAR ASSAM 785640 | SIVASAGAR | SIVASAGAR | ASSAM | 785640 | ₹3.0 Cr+₹41.5 L (16.0%) | L5 | Rejected-Finance Other than L1 bidder |
Tender Value
₹3 Cr
EMD Value
₹3.8 L
Closing Date
8 Aug 2022, 6:00 pmClosed
CWE (AF) Bagdogra
Commander Works Engineers (AF) Bagdogra Bagdogra Airport (WB) Pin- 734 421 Tele 0353 - 2698308
WORK SERVICES FOR INSTALLATION OF STATIC AIRCRAFT ARRESTING GEARS AT AF STN HASIMARA
2022_MES_534141_1
8484/HAS/2022-23/E8
Open Tender
Civil Works - Others
Item Rate
240 days
Hasimara
MES Contractor enlisted as Class B category ai bi having deposited Standing Security of Rs 4,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹2,000
GE (AF) Hasimara
₹3.8 L
Yes
8 Oct 2022
28 Jun 2022
16 Aug 2022
28 Jun 2022
8 Aug 2022
1 Aug 2022
Amount
Note 1: (Applicable for all parts/items) : The bidders/ contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender. B/R WORKS
Surface excavation not exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation in trenches not. exc 1.5 m deep and not exc. 1.5 m wide and getting out in soft / loose soil complete all as specified and directed.
Excavation over areas n.exc 1.5 m deep and getting out in soft / loose soil complete all as specified and directed.
Excavation over areas exc 1.5 m but n.exc 3 m deep and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25cm as in soft loose soil complete all as specified and directed.
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Use and waste of formwork to flat faces of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and making fair finish; and similar work; vertical or to batter complete all as specified and directed
M & L for PCC (1:4:8) type D2 (using 40mm graded stone aggregates) in foundation, filling and mass concrete complete all as specified and directed.
M&L for 150 mm thick granular sub base with Shingle or gravel, spread, rolled and consolidated to gradient and camber required complete all as specified and directed.
M&L for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and directed.
M&L for forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed.
M&L for design Mix M-30 (using 20 mm graded stone aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. Note:- Formwork and reinforcement shall be measured and paid seperately under relevent items.
M&L for chemical injection mortar for fixing MS anchor bolt to the foundation all as specified and directed. Note:- Anchor bolts shall be measured and paid seperately under relevent items as supply only.
M & L for mild steel TMT bars 10 mm dia, and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm to 10 mm dia, cut to length, bent to shape required in stirrups, spacers and binders and binding with mild steel wire (annealed) and not less than 0.9 mm dia, or securing with clips complete all as specified and directed.
M&L for Loose filling with aggregates of broken stone or boulders of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and directed.
Supply only mild steel anchor screw bolts (machine made) 50mm long, 11-15mm dia with hexagonal or sqsuare head at one end and screw the other, or screwed bolt ends, each screw end to be fitted with washer and one hexagonal or square nut, exc 5cm but n.exc 10cm long complete all as specified and directed.
S&F of Hard drawn steel wire fabric of weight exc 4 Kg per Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt complete all as specified and directed.
S&F of Reinforced concrete pipes of bore of dia 450 mm, of class NP2, laid and jointed complete with collars in cement mortar 1:1 all as specified and directed.
S&F of standard wall UPVC Pipe (SCH-40) 254 mm nominal size for installation of Fair LED tube complete all as specified and directed.
Supply and fixing of MS sqare plate 25.4 mm thick and 152.4X152.4 size for drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
Material & Labour for applying Two or more coats of non skid epoxy paint complete all as specified and directed.
M&L for 2.00 mm thick painting to road surfaces as in lines, dashes, arrows, zebra cross etc on roads, pavements and like with thermoplastic road marking paint @ 5Kg/Sqm and applying glass grit (BS 6088) @ 300 gram/Sqm over painting surfaces while the painting surfaces are hot by mechanical means including cleaning surfaces complete all as specified and as directed. Make:- STP/ ASIAN PAINTS/BERGER.) NOTE: Application shall be carried out through mechanical applicances by the approved applicator of the manufacturer of paint.
M&L for providing water proof insulation for pit wall and floor by installing a bituminous based elastomeric membrane of min thickness of 1.5 mm covered with 1" foamular 250 (cold climate) insulation board complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as in surface channels and drains including necessary formwork complete all as specified and as directed.
M&L for application of solvent cement for joining PVC complete all as specified and as directed.
M&L for solvent cement cleaner for clearing PVC complete all as specified and as directed.
M&L for solvent cement primer for joining PVC complete all as specified and as directed.
S&F of Mild steel bolts purpose made.with hexagonal or square head one end and screwed the other, or screwed both ends;each screwed end to be fitted with washers and onehexagonal or square nut. Exc 30 cm long & dia exc 20mm n.exc 25 mm complete all as specified and directed.
E/M WORKS
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 75mm OD conforming to IS, approved colour complete with fittings for cable protection complete all as specified and directed.
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm OD conforming to IS, approved colour complete with fittings for cable protection complete all as specified and directed.
Material and Labour for cast iron cable route indicator in round shape duly marked/engraved "Cable HT 11 KV" fixed on RCC block of size 250 mm x 250mm x 250 mm including painting with approved colour complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Taking down Existing unserviceable LT UG Cable of Size up to 35 Sq mm complete all as specified and directed. Note: Except Cable under Over Run and Near by Runway area/PTT as directed by Eng- in - Charge.
Taking down Existing unserviceable LT Junction Box and LT Cable complete all as specified and directed.
M&L for Boring of holes under road, pavement, hard standing, runway & PTT by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. Note : Price for HDPE Pipe of 150 mm dia included in the quoted rate.
Taking out / dismantling of existing Runway Elevated fitting any type, Taxi way light, stop bar lights, Isolating Transformer, etc including disconnecting all Electrical wiring including transporting from the runway site upto store for safe handing to the AF Auth Complete assembly for elevated Runway Edge lights, all as specified and directed.
Taking out / dismantling of existing Runway Elevated fitting any type, Taxi way light, stop bar lights, Isolating Transformer, etc including disconnecting all Electrical wiring including transporting from the runway site upto store for safe handing to the AF Auth Complete assembly for Inset runway edge lights, all as specified and directed.
Runway Edge Lighting, Inset Light with 2 X 105 w halogen lamps with 12 inch shallow base and bottom box cpmplete with filter, reflector and necessary optics. The light assembly shall be waterproof complete and facilitate easy replacement of lamps without compromising the optics and water tightness. The fitting shall be powered through the base and the wire entry should not disturb the water tightness. The light fixtures shall be tested with relevant ICAO requirements and FAA specifications. Routine tests such as photometric test as per latest ICAO and leakage test, Insulation tests shall be carried out on each fixture before leaving the OEM works. The choice of colours, materials and safety complete shall be in accordance with latest ICAO specifications complete all as specified and directed. Make: ADB/ Thorn (Safegate)/ Honeywell/ ATG/ IDMAN/ Astronics/ Crouse Hinds/ AMA/ Metro/ EngCorpn.
Dismantling of Inset Light Fitting including shallow Box, making good the damaged surface by Concrete complete as specified and directed.
Installation, Testing and Commissioning of inset type Runway fittings including installation of Isolating transformer, making connection with secondary lead etc. as reqd complete all as specified and directed.
Primary airfield lighting cables 5KV unearthed brass tape screened min 07 stranded tinned copper single core unarmoured with PVC insulation confirming to IS:1554-Part II. The cables shall be packed in drums not less than 1000 meters each. Operating temp rang (-20 deg to + 70 deg/C). The cable shall have all standard markings at intervals of 1mtrs. The insulation shall be resistant to rodent/termites and all local weather conditions. The cable shall be type tested and routine tested before leaving factory permises as per relevant IS compliant to ICAO Specs complete all as specified and directed. Make: Nexan/ Eupen/ Aloke Cables/ Coleman Cables/ Unika/Ankur
Laying of Primary Cable 1C x 6 sqmm in HDPE Pipe complete all as specified and directed. Note:- HDPE pipes of required dia will be measured and paid seperately under respective item of schedule.
Secondary airfield lighting cables 0.75 unearthed brass tape screened min 07 stranded tinned copper single core unarmoured with PVC insulation confirming to IS:1554-Part II. The cables shall be packed in drums not less than 1000 meters each. Operating temp rang (-20 deg to + 70 deg/C). The cable shall have all standard markings at intervals of 1mtrs. The insulation shall be resistant to rodent/termites and all local weather conditions. The cable shall be type tested and routine tested before leaving factory permises as per relevant IS and compliant to ICAO Specs complete all as specified and directed. Make: Nexan/ Eupen/ Aloke Cables/ Coleman Cables/ Unika/Ankur.
Connector kit for 5 KV primary cables, resin filled plug type suitable for conductors of cross sectional area 6 sqmm. The connectors shall be water resistant and insulation resistant in all aspects after soak test and the same shall be carried out on site as per relevant IS complete all as specified and directed. Make: EFLA/ATG/ADB/NORATEL/AMA/BILDAL
Supply and fixing of 32 mm bore HDPE Pipe of pressure Rating 6Kgf/Sq Cm laid in Trenches/ bore holes complete all as specified and directed. Note: Rates shall be inclusive of earthwork required for laying of HDPE pipe for primary/ secondary cable.
Cast Iron housing box cylindrical shape 330 mm Dia and 450 mm height with 10 mm thick cast Iron body. The top plate shall be of 15 mm thick suitable to receive a light fitting base plate. The body shall have clear holes for AFL cable entery 32 mm HDPE pipe and check nuts. The box shall have two earth bolts of M-10 x 30 mm welded inside near the cable entry hole on one side and having a drain hole at the bottom. Suitably tapped to receive 15 mm dia GI pipe and having clear opening of 220 mm at the top surface, and 6 Nos M-10 tapped hole at the center 260 mm dia to receive fitting base plate and bolts as required confirming to ICAO specifications complete all as specified and directed.
Isolating Transformer copper wound completely enclosed resin cast, rubber covered 5 KV, 50 HZ suitable for runway lighting applications of capacity 200-6.6-0.95, 90-6.53 confirming to IS 12290. Operating temp range -20 deg C TO 55 deg C. Primary 5 KV and secondary 0.6 KV voltage range. The transformer shall be supplied with two primary leads and two secondary leads and shall pass all routine tests before dispatch. Each transformer shall be accompained with test certificate and marking plates as per ICAO Rules complete all as specified and directed. Make: EFLA/ ATG/ ADB/ NORATEL/ AMA/ BILDAL.
Supply and laying of 40 mm dia GI pipe (Light grade) including accessories as T Joint, end cap, elbow etc to lay in under kerf cutting area for running cable complete all as specified and directed.
Material and labour for kerf cutting in existing asphalt surface of size 75mm x 100 mm deep for laying Gl conduit including accessories required & filing material matching with existing surface (DBM/M10) and making good as per existing surface complete all as specified and directed.
M&L for testing and Earthing of machinery/Equipment complete with Copper earth plate electrode 60cm×60cm× 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work PCC (1:3:6) type C-1 with suitable size of CI cover plate with angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15 cm compacted thickness all around the earth electrode with funnel and 20 mm bore galvanized iron watering pipe ( light grade) wire mesh, copper lugs, complete in all respect,including copper earth strip 25x3mm thick run in 40 mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion complete all as specified and as directed.
Supply, installation, testing and commissioning factory fabricated feeder pillar (outdoor type) weather dust and vermin proof fabricated out of 3.15 mm thick CRCA steel sheet outer portion AC 415 volts, 50 HZ of size 600 mm x 400 mm x 300 mm mounted on PCC foundation and inner portion of size 2.0 mm thick CRCA sheet suitable size of MS channel supports and and with suitable size of angle iron legs for grouting steel sheet powder coated paint internally and externally and locking arrangement including all incoming and outgoing connection with suitable size of lugs and glands including 04 Nos Copper busbar 3 phase 4 wire of rating 400 amps for phase and neutral complete all as specified and directed. Note:- PCC foundation shall be 1:3:6 type C-2 (using 40mm graded stone aggregates) including necessary formwork and excavation etc is deemed to be included in the unit rate quoted and as directed by the Eng-in-charge.
DEEP NIRMAN
M/S MANODEEP CONSTRUCTION
MAA BHAGWATI ASSOCIATES
Brahmaputra Commerce and Trade
NARSINGH DEVELOPERS LLP
S.N. GHOSH AND CO.
HARBHAJDAS AGARWAL
M/s KASHMIRA SINGH BARMI AND SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .