Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-Finance 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | L1 | Accepted-Finance bid value equal to estimate value | |
| 2 | L2₹2.0 L+₹1,160 (0.58%)Rejected-Finance | L2 | Rejected-Finance bid value greater than estimate value | |
| 3 | L3₹2.1 L+₹10,800 (5.43%)Rejected-Finance 126 B I MESS ROAD RAI MARKET AMBALA CANTT AMBALA CANTT HARYANA 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance bid value greater than estimate value |
Tender Value
₹2 L
EMD Value
₹2,000
Closing Date
28 Jun 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer ETD II Meerut
Executive Engineer,ETD II IInd floor Pareshan Bhawan Victoria Park Meerut
Various maintenance works at 132 KV S/S Hastinapur
2022_UPTCL_706817_1
T-02-2022-23/ETD-II Meerut
Open Tender
Electrical Works
Item Rate
90 days
Hastinapur Meerut
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Executive Engineer ETD II Meerut
₹2,000
28 Jun 2022
9 Jun 2022
28 Jun 2022
9 Jun 2022
28 Jun 2022
9 Jun 2022
120 days
Amount
Complete overhauling and attending leakage of SF-6 gas of 145 KV SF-6 circuit breaker installed on 132 KV transfer bus coupler Bay above overhauling includes following works to be done.
Dismantling of pole of all three phases of 145 KV SF-6 circuit breaker for attendind the gas leakage. The job including erection of the same pole after attending the gas leakage including cost of labour, T&P etc required for execution of the work.
Inspection and rectification of gas leakage of 145 KV SF-6 circuit breaker . The job includes opening of pole assembly of all three phases from upper & lower terminal flanges. Cleaning of all grooves of flanges and poreclains with petrol, scrubber pay and acrylic solution. Replacement of all O-ring of the pole upto 760 mm. Hg. After testing of vaccum for 12 hrs, and satisfactory result, refilling of Sf-6 gas upto required level. Checking of proper operation of CB from local and remote end. All materials, T&P except SF-6 gas required for execution of work, will be arranged by the contractor at his own cost.
The following work is required for smooth operation of cooling on 40 MVA T/F-I at 132 KV S/S Hastinapur. The details of work listed below
Supply and fixing of 01 no. main switch of 03P/1W, 415 Volts, 16 A rating and 01 on MCB of 04 pole, 415 Volts, 16 A rating phase incoming supply for cooling fans.
Supply and fixing of 01 no. 415 Volts, 16 A, 04 nos. contactor for main supply of cooling fans installed on 40 MVA T/F. Work includes proper connection of contactor with ACDB of AC cubical installed switchyard.
Supply and fixing of fan control contactor of rating 230V,9A, for auto function of cooling fans relays of rating 230V ,9A, 2NO+2NC for monitoring for cooling fans.
Supply and fixing of relays of rating 230V ,9A, 2NO+2NC for monitoring for cooling fans.
Supply and fixing of 3 pole MCB of rating 230V, 2A on the rail fixed on the front side of marshaling box.
Supply and fixing of overload relay (type 3US5000) of rating (0.5-2A) for cooling fan of transformer front side of the marshaling box.
Wiring of all interconnection with proper ferrules and lugs of suitable size with 4 sq. mm flexible insulated copper conductor for power connection and with 2.5 sq, mm flexible insulated copper conductor for control connecting in the marshaling box. Work includes supply and fixing of cable gland(19mm Dia) wire, rail base, ferrule, hugs as required for proper operation of marshaling box.
Supply and fixing of oil temperature indicator (analog type) of temp range from(0-50)DC, 5A,AC/DC both of two flexiable capillary tubes of 05 meter long and 04 no. mercury bulb switch for alarm, trip of power transformer of standard make. Work includes fixing of capilliary inside the temprature sensing element within the tank proper termination of connection at both ends.
SHASHI ENTERPRISES
J.P. TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .