Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical NOT QUALIFY |
Tender Value
₹84.3 L
EMD Value
₹84,350
Closing Date
15 May 2024, 12:45 pmClosed
SE, EUDC-I, NOIDA
33/11 KV SUBSTATION, SECTOR-18 FIRST FLOOR, OPPOSITE SAB MALL, NOIDA
12 WORK IN HEAD 11 KV AS PER DPR Sl NO 2 3 4 5 18 19 20 21 22 23 24 25 UNDER EUDD 7 NOIDA
2024_PVVNL_922581_2
109/EUDC-I/2023-24/NOIDA (WORKS)
Open Tender
Electrical Works
Item Rate
IN AREA OF EUDSD-II/XIII, NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
EE, EUDD-VII, NOIDA
₹84,350
23 May 2024
10 May 2024
15 May 2024
10 May 2024
15 May 2024
10 May 2024
Amount
Cartage of following material from ESC Noida/Sahibabad/ Ghaziabad /Any other ESC of Meerut Discom to JE Store and from JE store to various points site of work including loading and unloading at both ends : -
11 KV XLPE Cable of size 3x185 Sq.mm.
ST Pole 11 Mtr. long.
Polymeric 11 KV Pin Insulator with pin.
M.S. Angle Iron 65x65x6mm 2700 mm.
M.S. channel 100x50x2028mm .
Top channel M.S. 125x65x3200mm with clamp.
Cable support M.S. Angle Iron 65x65x6mm 2700 mm bracing with 4 clamp.
Stay set complete.
Earthing complete.
11 KV Outdoor jointing kit suitable for 11 KV 3x185 sq.mm. XLPE cable.
33 KV Straight Through suitable for 11 KV 3x185 sq.mm. XLPE cable.
Providing & fixing of following material of standard make / best quality for complete the work of double pole / section double pole structure at 11 KV line as per RESPO norms by the contractor at his own cost : -
Stone pad 300x300x75mm.
Eirth wire clamp with bolt & nut.
PG Clamp
G.I. Pipe 6" Dia
Number plate.
Danger board with clamp.
Barbed wire.
Alluminium Binding wire 6 SWG / Tape.
Alluminium Paint.
Bolt, nut and washer.
Red oxide paint.
MS clamp / Holding clamp with nut & bolts.
RCC / Stone Route Marker yellow colour with proper marking.
Concreating of stay.
HDPE Socket suitable for HDPE pipe 160 mm dia.
Grouting & concreting of stay rod 1800x16 mm & Fixing, Tighting & nozzling of stay wire 5 kg with the pole of required tension with clamps, bolt & nut.
Excavation of earth and driving of M.S. earthing rod of size 20x2500 mm in earth and jointing through G.I wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts etc. as per RESPO schedule Complete in all respects.
Fixing of 11 KV Outdoor jointing kit suitable for 11 KV 3x185 sq.mm. XLPE cable.
Fixing of 33 KV Straight Through suitable for 11 KV 3x185 sq.mm. XLPE cable.
The Excavation of foundation pit in CC road/ mix soil/ normal soil/ soft & hard rack by using heavy duty compressor and its back filling and leveling etc. The size of the pit will be 600x600x1800 mm for each pole and having a depth of 1/6 of the full length of the support.
Fabrication of MS channel / Angle as per site requirement complete in all respects.
Erection of Section Double pole structure on 11 Mtr. long ST Pole for 11 KV line including fixing of all accessories of 11KV line as per RESPO schedule Complete in all respects.
Grouting of each pole (In ratio of 1:4:8 in Cement, sand and Brick Ballast) in size 450mmx450mmx1800 mm as per RESPO schedule Complete in all respects.
Construction of Plinth in size 450x450x300 mm of each (0.880 Cu.m) pole above the ground level (In ratio of 1:3:6 in Cement, sand and Brick Ballast) as per RESPO schedule Complete in all respects.
Drilling of dia suitable for 160 mm dia by trench less method by horizontal boring machine at a depth of 1.5 mtrs below the ground level for laying of cable complete in all respects.
Providing of 06 Mtr long pieces of HDPE pipe (4 Kg / m2) 160 mm Dia PN 4 PE 63 (PVVNL approved) after inspection of competent committee at manufacturing site of the items with actual guarantee period.
Laying and interconnecting of above 06 Mtr long pieces of HDPE pipe 160mm Dia PN 4 PE 63 (PVVNL approved) in trench for laying of cable complete in all respects..
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop.
Road Restoration charges for hot mixed pakka road / CC road / kaccha road / mix soil/ normal soil/ soft & hard rack as it is when start of work as per authority norms.
Laying and pulling of 11 KV XLPE Cable 3x185 Sq.mm. through HDPE pipe, loop & riser complete in all respects.
Laying of 11 KV XLPE Cable 3x185 Sq.mm. through open cut method complete in all respects.
Hi port test for 11 KV 3x185 sq.mm XLPE cable.
Hoisting of 11 KV 3x185 sq mmXLPE cable on section double / four pole structure through GI pipe 6 inch dia 3 mtr long fixed on pole structure including its jumpering complete with clamps, bolts and nuts.
M/S PRAKHAR ELECTRIC WORK
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .