Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC 55 1 CHARAKDANGA NATUNPUKUR ROAD BARASAT KOLKATA 700124 | KOLKATA | KOLKATA | WEST BENGAL | 700124 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.3 L+₹33,622.31 (4.20%)Rejected-Finance MALLICK JAYANTI BAGAN KUMAR BAGAN JHAPPUKUR POST SAHAGANJ DIST HOOGHLY HOOGHLY 712103 | HOOGHLY | HOOGHLY | WEST BENGAL | 712103 | L2 | Rejected-Finance Highest Amount Quoted | |
| 3 | L3₹8.4 L+₹35,759.46 (4.47%)Rejected-Finance GANGPUR P O JOTERAM DIST PURBA BARDHAMAN PIN 713104 | PURBA BARDHAMAN | WEST BENGAL | 713104 | L3 | Rejected-Finance Highest Amount Quoted | |
| 4 | Rejected-Technical PRACHIN MAYAPUR SRICHAITANYA COLONY DIST NADIA PIN 741302 | NADIA | NADIA | WEST BENGAL | 741302 | - | Rejected-Technical technically not qualified |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
16 Oct 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive_Engineer_PWD_Hooghly_Electrical_Division
Executive_Engineer_PWD_Hooghly_Electrical_Division_Purta_Bhavan_3rd_Floor_Sarat_Sarani_Kodalia_Hooghly_Pin_712123
Renovation_to_the_Electrical_Installation_and_allied_works_of_Hooghly_Madrasah_Chinsurah_Hooghly_SITC_of_40KVA_DG_set
2020_WBPWD_300797_1
WBPWD/EE/ HED / NIeQ- 18/ 2020-21
Open Tender
Electrical Work/ Equipment
Item Wise
25 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹16,000
15 Dec 2020
9 Oct 2020
20 Oct 2020
9 Oct 2020
16 Oct 2020
9 Oct 2020
120 days
Amount
SITC at site on foundation of 40 -KVA, 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-II approved Engine & Acoustic Enclosure having following specifications :-
ENGINE
Make : Cummins/Greaves/Kirloskar/Ashok Leyland
Engine Type : 3/4 Stroke Diesel Engine
Rated Output : 52 BHP or Higher
Duty : PRIME
Cooling : Water cooled with radiator
Cylinder : 3/4In-line or higher
Aspiration : Turbo Charged, Charge Air Cooled
Type of Governer : Mechanical/ Electronic
Fuel Tank Capacity : Minimum capacity 100 Ltrs.
Fuel Consumption at 75% rated Load with Radiator or Fan : 7.4 Ltr./ Hr. or Less
Fuel Consumption at 100% rated Load with Radiator or Fan : 9.45 Ltr./ Hr. or Less
Overload Capacity : 10% overload for one hour for every 12 hours continious running at full load or better
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator
Exhaust Silencer : Residential Type
Starting system : 12V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
ALTERNATOR
Make: Stamford/Crompton Greaves /Kirloskar/ Ashok Ley Power
Rating : 415 V., 3Ph. 50 Hz., 40 KVA, 1500 rpm
Type : Brushless, self excited and self regulated
Insulation : Class H
Protection : screen-protected drip proof with Min. IP-23 degree of protection
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 3%
Total Harmonic distortion in output waveform : No Load<1.5%, Non distorting balanced linear load<5%
AMF PANEL
Cubical type AMF panel in DG canopy made from 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 40 KVA DG set having following specification/features.
i) 80A 36 KA MCCB with O/L, S/C, E/F protection and microprocessor based protection release , U/V release etc. - 2Sets
ii) In Built By-Pass switch for rated capacity
iii) On -delay timer for load change over
iv) On-delay timer for engine shut off
v) Engine On-Off switch (Push button type)
vii) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
viii) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
x) Microprocessor based relay with composite meter for digital display of following.
Generator voltage/AC Mains voltage.
Generator Current in all phases
Frequency
Power Factor
Energy
Indication for alternator supply
Running time indications number of hours of operation and service intervals, service due indications
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
ACOUSTIC ENCLOSURE
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustict enclosure must be certified as per CPCB-II norms.
BASE FRAME
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duty etc.
(ii) All materials, equipments & accessories must conform to relavent IS /IEC specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.
(iii) Nacessary manufacturer's test certificate for Desiel Engin, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(iv) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competant Authority (As per CPCB-II).
(v) Circuit Diagram for AMF Panel must be submited from the Manufacturer/OEM.
(vi) The entire set must be warranted atleast 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier.
Extending the exhaust pipe with 100 mm. dia MS black pipe (Thickness 4 mm) including connection with the existing silencer attached with the flexible coupler and S&F flange, nuts, bolts & washers etc. & necessary fixing materials etc. as required from DG set upto 2.5 Mts high of the near higher installation with Asbestos rope / glass wool insulation and chicken net and Aluminium fol covering, with end cap with suitable high temperature painting.
Making insulation by 2" glass wool including netting arrangement and covered with aluminium clading as per direction of the EIC.
a) 100 mm. dia exhaust pipe.
b) Residential type silenser pipe
S&F special type MS angle iron bracket support made of 40x40x6 mm. MS angle with flat iron clamp with nuts, bolts & washers etc. for 90 mm. dia (Vertical Run).
S&F rain protection canopy.
Filling of HSD oil for initial refill with transportation.
Supply and delivery of best quality oil hand pump with 1" dia PVC flexible pipe (10 mtr. approx.)
Supply and delivery of 200 ltr. Capacity heavy gauge PVC barrel
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS . [ 2(a)/G-1]
Connecting the equipment with 25mmx6mm galvanised MS hot dip flat on wall/floor as to GS. [5d/G-3]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m. ( upto 150mm thick ) [ Page 10, item no 2 ]
Earth work in excavation of foundation trenches of drains, in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.( Depth of Excavation not exceeding 1500 mm ) [ Page 1, Item no.2(a) ]
Single brick flat soiling of picked jhama bricks including ramming and dressing bed to proper level and joints with local sand. [ Page 14, item no.1 ]
Filling in foundation by silver sand not exceeding 150mm. [ Page 2, item no.4 ]
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after work [ Page 42, item no.36 ]
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor/upto 4 m Tor steel/Mild Steel SAIL/ TATA/RINL : In ground floor
Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20 mm size) including shuttering and reinforcement, if any, in ground floor as per relevant IS codes ( Pakur variety ) [ Page 26, item no.10 ]
Brick work with 1st class bricks in cement mortar (1:4) In foundation and plinth. [ Page 16, item no.13a ]
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] [ Page 187, item no.1i(c) ]
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Add GST @12%:- Rs.
Add LWC @1% except item no.- 7& 8 :- Rs.
B.S.M ELECTRICAL
PERFECT RENEWABLE AGENCY
stage.html
html • 0.05 MB
technical_562099.pdf
PDF • 0.60 MB
techsummary_562099.pdf
PDF • 0.77 MB
finance_562099.pdf
PDF • 0.48 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_562099.pdf
PDF • 0.48 MB
18.PDF
PDF • 0.83 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .