Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.2 Cr
EMD Value
₹2 L
Closing Date
15 Dec 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CGMPP_D
CGMPPD 6th floor Bijulee Bhawan Paltanbazar
Construction of new RCC office building
2025_APDCL_48916_1
APDCL_CGMPPD_CiW_Kalaigaon_146
Open Tender
Civil Works
Turn-key
Mangaodoi
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
₹2 L
CGMPPD6th floor Bijulee Bhawan Paltanbazar
5 May 2026
28 Nov 2025
17 Dec 2025
28 Nov 2025
15 Dec 2025
4 Dec 2025
28 Nov 2025 - 3 Dec 2025
3 Dec 2025
Construction
Total Amount of Supply Price
Total Amount of Installation/Erection charges
Total of complete work
Discount if any Offered by Bidder in %
BoQ_Ver3.1
Name of the Bidder/ Bidding Firm / Company :
Price bid Schedule for Project Area (All Prices in Indian Rupees)
NUMBER #
Total Amount (Supply + Erection) (Exclusive GST ) (in Rs.)
BoQ_Ver3.1
Advisory Note to Bidders 1. For Supply and F& I Part: - The Prospective bidders are required to insert the Ex-Work rate for the items under respective column against the BOQ. In case the quoted unit price of same item are found different in BOQ schedule the high quoted price will be considered for technco commercial evaluation and the lowest quoted price will be consider in LOA
Name of the Bidder/ Bidding Firm / Company :
Construction of new RCC Office Building for the O/o the Sub-Divisional Engineer, Kalaigaon Electrical Sub-Division under Mangaldoi El. Circle on full turnkey mode
NUMBER #
Laying and Jointing PVC Pipe. Heading
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. I) By Manual Means- A) Up to a depth of 2.00m below the existing ground level. a) In ordinary soil
Earth/sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non- plastic) by truck carriage including loading and unloading.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary, dewatering, complete. (a) Brick on flat soling
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete. In prop 1 cement: 3 sands :6 coarse aggregate by volume
REINFORCEMENT-Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained). Super Ductile TMT reinforcement bar (Fe 500D). A) Up to G+2 RCC Buildings.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. I) Using 25mm thick plank
3.1.1.2) Sides of tie beams, grade beams etc. at or below ground level. ii) Using 25 mm thick plank
3.1.1.3) Columns, Pillars, Posts & Strut- a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face- ii) Using 25 mm thick plank
Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm downgraded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work-Without using admixture, plasticiser-2.2.2.1) Using Mixer Machine-I) In substructure up to plinth level- Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. ii) M20 grade concrete or Prop. 1:1.5:3
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embedded in cement mortar and will be measured and paid separately). (A) 112 mm thick brick wall- (b) In cement mortar in proportion 1:5 (1 cement:5 sand)
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx 3mmx 250mm) as per design embedded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (b) With 1st class timber (Bonsum/ Sundi)
Providing, fitting and fixing full paneled doors/ windows including oxidized M.S butt hinges (100 mm x 75 mm x 3.55 mm) with necessary screws (other fittings to be measured and paid separately). I) With Teak wood / Sissu wood. c) 30 mm thick.
Varnishing two coats (excluding priming coat) on new wood and wood-based surfaces under coating with flatting varnish and finishing coat with copal varnish or spar varnish to give an even surface including cleaning the surface of all dirt, dust and filling the knots, crack etc.; with specially made wood putty and sand papering so as to produce a smooth, dry surface. a) Surfaces over 100 mm in width or girth.
Applying two coats of wood preservative oil (colorless) of approved make on new wood and wood-based surfaces, after including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
Supply with installation and commissioning of readymade maintenance free CPRI approved technology...............including plastering both inner and outer surface of brick wall as specified and directed by the Dept.
ANNEXURE - 1 (All prices in Indian Rupees) Construction of new RCC Office Building for the O/o the Sub-Divisional Engineer, Kalaigaon Electrical Sub-Division under Mangaldoi El. Circle on full turnkey mode
Providing, fitting and fixing standard aluminium sliding windows and ventilators of standard sections ( with minimum thickness 1.9 mm ) of approved brands without horizontal glazing bars joints mitred and jointed with SS screws (manufactured to IS: 733 and IS: 1285 specifications) and providing and fixing handles, angle cleat, EPDM rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (Glazing to be measured and paid separately)- (b) 3 Track sliding window- i) Normal Anodized Aluminum
Providing, fitting and fixing Glazing and Pre laminated board of specified thickness for Aluminum and UPVC works on windows, doors, partition walls, curtain wall etc. as specified and directed by the department at all levels. Clear Glass-5.00 mm thick
(I) CERAMIC TILES- A) AT FLOOR- Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cemen
Providing, fitting and fixing Glazing and Pre laminated board of specified thickness for Aluminum and UPVC works on windows, doors, partition walls, curtain wall etc. as specified and directed by the department at all levels. Frosted Glass-5.00 mm thick
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ opening with M.S. flats at required spacing in frame all round, square or round M.S. bars with round headed bolts, nuts or screws. 10.2.2) Ornamental grill c) Fixed to steel frames (@ 15.5 kg/sqm)
15 mm thick Cement plaster in single coat on brick / AAC / concrete walls for plastering for both fair or rough side up to 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4
t mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (colored pigment should be in conformity with color of slab and as approved and directed by the Department). c) 600 mm x 600 mm and above
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture on new surface to give an even shade after thoroughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. Approved brand and manufacture:
Extra over item no 13.4.7 above for every subsequent coat.
Applying one self-priming coat of acrylic emulsion paint of approved brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. Approved Brands
Finishing wall with two coats of acrylic emulsion paint of approved brand of required shade by thinning by adding water as per the specification of manufacturer after thoroughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
Extra over item no.13.5.2 above for every subsequent coat.
Applying priming coat over new wood and wood-based surfaces after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter , sand papering and knotting. a) Surfaces over 100mm in width or girth. ii) With ready mixed paint , wood primer
Painting two coats (excluding priming coat) on new wood and wood-based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac/ DUCO paints) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. a) Surfaces over 100mm in width or girth. (i) General purpose
Varnishing two coats (excluding priming coat) on new wood and wood-based surfaces under coating with flatting varnish and finishing coat with copal varnish or spar varnish to give an even surface including cleaning the surface of all dirt, dust and filling the knots, crack etc. with specially made wood putty and sand papering so as to produce a smooth, dry and matt surface. Surfaces over 100mm in width or girth.
Applyin
g two coats of wood preservative on wood and wood-based surfaces including preparing the surface by thoroughly cleaning oil, grease dirt and other foreign matter, sand papering and knotting. (c) With raw linseed oil
Supplying, fitting, fixing electro-colored iron fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for wood screws including necessary screws etc. complete. A) Sliding door bolts- 300mm x 16mm
Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors wherever required. (Flushing Cistern to be paid separately). Indian type W.C Orissa pattern of size 580 x 440 mm. a) White
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. a) White
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high) with seat and lead, CP brass hinges and rubber buffers, CI/MS brackets, 40 mm Dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately). A) White
Supplying, fitting, fixing electro-colored iron fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for wood screws including necessary screws etc. complete. B) Tower bolts- 300mm x 10mm
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)- PEDESTAL BASIN (with pedestal)- a) White
Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings, cutting & making good the walls wherever required.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme / Prince) or other ISI approved including joining, fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (vii) 50mm Dia
Providing fitting & fixing C.I. Grating to the floors complete as directed and specified. (a) 110mm Dia
Construction of inspection pit inside measurement 450mm x 450mm x 450mm flush with 100mm Diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12 cm brick wall in cement mortar in proportion 1:4 finished with 13 mm cement plaster in proportion 1: 2 in side wall and floor. 450mm x 450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed. (a) 110mm Dia
Supplying fitting and fixing C.P. bib cock 15 mm Dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately)- (a) 110mm Dia (I) 15mm Dia Bib Cock
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately)- (i) 15mm Dia
Supplying and fitting fixing C.P. pillar cock of 15 mm Dia of approved brand as specified and directed.
Supplying and fitting ball valve as specified and directed. a) 25 mm dia. (gun metal)
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (b) Sona
Supplying and placing plastic cylindrical vertical closed top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. 1000-liter capacity- (a) Sintex make
Labour for erecting and placing the G.I. Tank over the stagging of a height above 5.00 m up to 8.00 m complete as directed. (b) 1000-liter capacity
Labour for sinking tube well with 40mm (internal) Dia G.I. Pipes up to having strata, having potable water including fitting and fixing strainer hand pump and other accessories as directed complete as in any soil.
Labour for test boring with 40mm (internal) Dia G.I. Pipes including keeping surplus of earth and every 2.00 m after first 3.00 m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. I) Bore hole of 75mm Diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. ii) 65mm Diameter
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. I) By Manual Means- A) Up to a depth of 2.00m below the existing ground level. a) In ordinary soil
Brick work in cement mortar with 1st class brick including raking out joints and curing complete as directed. A) In Sub-structure up to plinth level including dewatering if necessary-iv) In proportion 1: 6 (1 cement: 6 sand)
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13 mm to 32 mm including dewatering if necessary, and curing etc. complete. b) 50 mm thick
Plain cement concrete works with coarse aggregate of sizes 13 mm to 32 mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). iii) In prop 1 cement: 5 sands :10 coarse aggregate by volume
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.3) Columns, Pillars, Posts & Strut-a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face-ii) Using 25 mm thick plank
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete up to 1st floor level Note: - lap length for reinforcement bars (25mm or above) will be measured and paid separately. III) Other ISI approved TMT reinforcement bar of Fe-500 N/mm2 (For Assam Type Bldg., drain works, boundary wall etc.)
Supplying, fitting, fixing electro-colored iron fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for wood screws including necessary screws etc. complete. D) MS door handles-150 mm
VITRIFIED TILES- II) ON FLOOR- Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18 mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (A) NORMAL RANGE- (c) 495 mm x 495 mm
VITRIFIED TILES
- (I) ON WALL- Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Colored pigment should be in conformity with color of tiles and as approved and directed by the Department). d) 300 mm x 600 mm
Wiring for light/fan/call bell point with 2x1.5 sq mm PVC insulated single core unsheathed industrial (multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finnolex/RR Kabel or equivalent make as approved by the Dept) with flat 19 mm ISI marked casing "n" capping.....................etc., as complete and specified by the department. Short point up to 3.00-meter length
Wiring for light/fan/call bell point with 2x1.5 sq mm PVC insulated single core unsheathed industrial (multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finnolex/RR Kabel or equivalent make as approved by the Dept) with flat 19 mm ISI marked casing "n" capping.....................etc., as complete and specified by the department. Medium point up to 6.00-meter length
Wiring for light/fan/call bell point with 2x1.5 sq mm PVC insulated single core unsheathed industrial (multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finnolex/RR Kabel or equivalent make as approved by the Dept) with flat 19 mm ISI marked casing "n" capping.....................etc., as complete and specified by the department. Long point up to 10.00-meter length
Wiring to a 5 pin 6 Amps plug point with 1.5 sq mm PVC insulated single core unsheathed industrial (multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finnolex/RR Kabel or equivalent make as approved by the Dept) with flat 19 mm ISI marked casing "n" capping...........................etc., as complete and specified by the department. Short point up to 3.00-meter length
Wiring to a 5 pin 6 Amps plug point with 1.5 sq mm PVC insulated single core unsheathed industrial (multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finnolex/RR Kabel or equivalent make as approved by the Dept) with flat 19 mm ISI marked casing "n" capping...........................etc., as complete and specified by the department. Medium point up to 6.00-meter length
Wiring to a 5 pin 6 Amps plug point with 1.5 sq mm PVC insulated single core unsheathed industrial (multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finnolex/RR Kabel or equivalent make as approved by the Dept) with flat 19 mm ISI marked casing "n" capping...........................etc., as complete and specified by the department. Long point up to 10.00-metre length
Wiring to a 5 pin 6 Amps plug point with 4 sq mm PVC insulated single core unsheathed industrial (multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finnolex/RR Kabel or equivalent make as approved by the Dept) with flat 19 mm ISI marked casing "n" capping...........................etc., as complete and specified by the department. Short point up to 3.00-meter length
Wiring for drawing sub-main line with PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finnolex/RR Kabel or equivalent make as approved by the Dept) in surface flat ISI marked casing "n" capping...........................system including earth continuity. With 2x2.5 sq mm +earth continuity with 1x1.5 sq mm in flat 19 mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finnolex/RR Kabel or equivalent make as approved by the Dept) in surface flat ISI marked casing "n" capping...........................system including earth continuity. With 2x4 sq mm +earth continuity with 1x2.5 sq mm in flat 19 mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finnolex/RR Kabel or equivalent make as approved by the Dept) in surface flat ISI marked casing "n" capping...........................system including earth continuity. With 3x2.5 sq mm +earth continuity with 2x1.5 sq mm in flat 19 mm ISI marked casing 'n' capping system.
Supplying including fitting and fixing of following AC Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connections as approved by the Dept. As required complete and as directed by the Department. (without regulator).
Supplying including fitting and fixing of AC Ceiling fan regulator including connections etc., complete as required.
Supplying including fitting and fixing of following AC Exhaust fan complete in the existing hole on the wall of following sweeps with making necessary connections as approved by the Dept. As required complete and as directed by the Department.
Supplying and fixing of Switch/Socket flush type Anchor penta PC cherry/….... including connections as approved by the Department complete as required.
Supplying and fixing of Call bell including 6-amp capacity flush type bell push switch including connection as approved by the Deptt. As needed
Supplying with installation, testing and commissioning of Hi-wall 3 STAR rating, non-ducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical condition as approved by the Department up to 5m between the room unit and outdoor unit as directed by the department. 1.5-ton capacity (Voltas make)
Installation, testing and commissioning of pre-cabled fluorescent fittings of all types, complete with all accessories and tubes etc., directly…...........with 1.5 sq mm PVC copper wires as required.
Supplying with fitting and fixing Voltage Stabilizer of the following specifications complete …......as directed by the Deptt. 3.0 KVA Automatic input stabilizer
(I) CERAMIC TILES- B) WALL TILES- Providing ceramic wall tiles of approved quality, size, shape and thickness not less than 8 mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Colored pigment should be in conformity with color of tiles and as approved and directed by the Department). (A) Normal range- e) 300 mm x 300 mm
Painting two coats (excluding priming coat) on new steel and other metal surface with aluminum paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) and brushing to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (a) Surfaces over 100mm in width or girth
Supplying, fitting, fixing anodized, aluminum fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminum screws etc. complete. (anodized, bright natural matt & satin finished). e) Butt hinge-100mm x 75mm x 4mm
Supplying, fitting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified. (pipes will be measured separately). A) White
15 mm thick Cement plaster in single coat on brick /AAC / concrete walls for plastering for both fair or rough side up to 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4
Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/ 1200mm x 600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm / 6mm thick High-Pressure Steam Cured Non-Asbestos Fiber Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm Dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm /1200mm x 600mm grid, all complete as per the drawing & directions of engineer-in-charge. i) Everest Standard Ceilings or equivalent as directed by the department- b) 6 mm
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. 10.16.1) Hot finished welded type tubes-1) M.S. black tubes @ 114.3 OD, @ 12.1 kg/mtr
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. 10.16.1) Hot finished welded type tubes-2) Rafters ISA 75x75x5 @5.7 kg/mtr
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. 10.16.1) Hot finished welded type tubes-3) Main tie ISA 75x75x5 @5.7 kg/mtr
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. 10.16.1) Hot finished welded type tubes-4) Struts ISA 75x75x5 @5.7 kg/mtr
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. 10.16.1) Hot finished welded type tubes-5) Purlins ISA 75x75x5 @5.7 kg/mtr
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. 10.16.1) Hot finished welded type tubes-6) Hip rafter ISA 75x75x5 @5.7 kg/mtr
Providing, fitting and fixing aluminum hollow section of size 63.50mm x 38.10mm x 2.5mm thick for aluminum frame partition wall of approved brands, with frames of a maximum spacing of frame 1.20 m joints mitred and jointed with SS screws (manufactured to relevant I.S. specification) and providing and fitting angle cleat, rubber gasket, bolting device screws etc. at all levels. i) In Normal Anodized Aluminum Section
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.28 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
Bid.pdf
Tender Documents • 1.14 MB
BOQ_77636.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .