Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹28.1 LAccepted-AOC LEELA NIWAS CHALAUNTHI SANJAULI SHIMLA 6 | SHIMLA | HIMACHAL PRADESH | 171001 | ₹28.1 L | 1 | Accepted-AOC L1 |
| 2 | 2₹28.3 LRejected-Finance PO DHARCHANDNA TEHSIL CHOPAL DISTT SHIMLA | ₹28.3 L | 2 | Rejected-Finance High Rate |
| 3 | 3₹28.4 LRejected-Finance NEAR NEW BUS STAND ANNI DISTT KULLU H P | KULLU | HIMACHAL PRADESH | 172001 | ₹28.4 L | 3 | Rejected-Finance High Rate |
| 4 | Rejected-Technical C O ZAMA MASZID GALI NO 3 MIDDLE BAZAR SHIMLA 171001 H P | SHIMLA | HIMACHAL PRADESH | 171001 | - | - | Rejected-Technical Technical Reject |
| 5 | Rejected-Technical HPSEBL THALOUT | KANGRA | HIMACHAL PRADESH | 176201 | - | - | Rejected-Technical Technical Reject |
Tender Value
₹27.5 L
EMD Value
₹27,490
Closing Date
26 Feb 2026, 11:00 amClosed
S.E (OP) Circle
S.E (OP) Circle
SoP to LIS Rahud Khad to Karyal in GP Darbhog Tehsil and District Shimla (HP) in ES Mundaghat under ESD, HPSEBL, Junga
2026_HPSEB_128960_1
DB-Tender-20(SOP to LIS Rahud Khad)/2025-26
Open Tender
Electrical Works
90 days
Shimla
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,180
₹27,490
9 Mar 2026
20 Feb 2026
26 Feb 2026
20 Feb 2026
26 Feb 2026
20 Feb 2026
Supply & Erection Cost of 11/0.4KV, 400 KVA S/Stn. as per Annexure "A"
Supply & Erection Cost of HT Line as per Annexure "B"
Supply & Erection Cost of CT-PT Unit as per Annexure-"C"
Note:- Bidder are instructed to fill in the (+/-)% after referring to the irem, rate and quantity in Annexures uploaded online alongwith tender documents
Please Enable Macros to View BoQ information
HIMACHAL PRADESH STATE ELECTRICITY BOARD LIMITED
Tender No. DB-Tender-20(SOP to LIS Rahud Khad)/2025-26.
Sub Station as per Anx-A
HT Line as per Anx-B
CT/PT as per Anx-C
Grand Total
Add. Freight & Insurance Charges
G. Total
Superintending Engineer,
Operation Circle, HPSEBL,
Kasumpti, Shimla-9.
HIMACHAL PRADESH STATE ELECTRICITY BOARD LIMITED
SCHEDULE OF QUANTITIES AND PRICE
Tender No. DB-Tender-20(SOP to LIS Rahud Khad)/2025-26
Supply Part
1x630 kVA S/Stn. along with the following material as per the Tender specification & confirming to relevent ISS:
Distribution Transformer (Ordinary), 11/0.4 kV, 400 KVA Three Phase, Outdoor type confirming to IS-and IEC specification complete in all respect. Make: Voltamp/Svasca/Jay Bee or approved vender of HPSEBL
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs (2000mm) with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incommer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800mm) X 4 Nos] for supporting DO fuse unit & GO switch
Transformer LT Distribution Box and GO Switch fixing Assembly
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos 370 Rs/mtrs.
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos 370 Rs/mtrs.
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm 563Rs/Mtrs
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit
Surge Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Pipe Earthing Set
6 SWG GI wire For Earthing
LT Distribution Panel Box with ACB 630A, 50kA, 4P,1No. Incoming and for outgoing 3x300A MCCB, 4P,36KA, 3Nos.
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Copper Thimble 200 Amp
Danger Plate
LT Cable (3.5 Core) 400 mm² X 2 incommer (DTR to Panel)
LT Cable (3.5 Core) 185 mm² X 3 Outgoing (LT Panel to JSV Panel)
Energy Meter (3-Phase, 4-Wire) DLMS compliant 600/5 A CT Type for 400KVA Transformer
a)Aluminium Paint.
b)Red oxide
Complete erection, testing, commissioning of 22/0.4 KV, 400 KVA Sub-Station complete in all respect including earthing of Sub-Station and erection of all items
Chain link Fencing, Angle Iron Gate etc around 400 KVA Transformers and CT/PT Unit
Transformer Bed for 400 KVA DTRs
Trasportation Charges
Manual carriage of material for 1x400 KVA S/Stn. Av. Lead 1.8 KM
Grand Total
Add. Freight & Insurance Charges
G. Total
Superintending Engineer,
Operation Circle, HPSEBL,
Kasumpti, Shimla-9.
HIMACHAL PRADESH STATE ELECTRICITY BOARD LIMITED
SCHEDULE OF QUANTITIES AND PRICE
Tender No. DB-Tender-20(SOP to LIS Rahud Khad)/2025-26
Supply Part
HT Line along with the following material as per the Tender specification & confirming to relevent ISS:
ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3Φ and Additional 3% (Sag, Jumpering and wastage}
Steel Tubular Poles 9 Mtr Long
Muffs (2000mm) with concerete filling
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 3% (Sag, Earthing, Cross lacing above road and wastage)} @ 0.102 kg/m
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps, Straight stapples & Bend Stapples etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incommer line
X-Arm: [Channel Iron (100x50x6 mm), Length : 2400 mm X 2 Nos] for incommer line
X-Bracing Set - MS Angle iron for Belting 50X50X6mm L=1500 mmX2 Nos & L=2800mmx2 Nos
Knee Bracing Set
Stay set complete in all respect (i/c Stay Clamp) (1No./ Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate (250X200X1.6 mm)
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
Erection of Single pole structure consisting of Steel Tubular Poles 9/10 Mtrs long(W/L 200 kg), Digging of pit, Drilling of Holes in poles & X Arms, Fixing of Insulator, X-Arms, X-Bracing Set, Erection of Poles, Fixing of barbed wire, Danger plate, filling of pit+Ramming, painting of poles complete in all respect
Erection of Double pole structure consisting of Steel Tubular Poles 9/10 Mtrs long(W/L 200 kg), Digging of pit, Drilling of Holes in poles & X Arms, Fixing of Insulator, X-Arms, X-Bracing Set, Erection of Poles, Fixing of barbed wire, Danger plate, filling of pit+Ramming, painting of poles complete in all respect
Sagging of conductor, laying of conductor, Stringging & Sagging, binging with insulator (ACSR 6/1/3.35mm2)
Laying Stringging & Sagging of GI wire for continious earth wire
Erection of stay sets Nozzeling & Tighting complete in all respect
Erection of GO Switch
Erection of HT Earthing Set
Manual carriage of material HT Line Average lead 1.8 KM (1.8x0.850=1.53KM)
Grand Total
Superintending Engineer,
Operation Circle, HPSEBL,
Kasumpti, Shimla-9.
HIMACHAL PRADESH STATE ELECTRICITY BOARD LIMITED
SCHEDULE OF QUANTITIES AND PRICE
Tender No. DB-Tender-20(SOP to LIS Rahud Khad)/2025-26
Supply Part
CT-PT Unit along with the following material as per the Tender specification & confirming to relevent ISS:
CT-PT Combined Unit [PT:11 kV/110 V) ; CT:10-50/5A]
3-phase, 3/4-Wire CT-PT operated Static Trivector HT Meter (DLMS Compliant 50/5A)
PVC Multistrand 4 mm² copper wire with Φ-1 inch GI pipe for concealing
Steel Tubular Poles 9 Mtr Long
Muffs (2000mm) with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 4 Nos]
X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of CT-PT Unit]
MS Angle Iron (50X50x6 mm), Length: 2800 mm x1 Nos for LA's)
CT-PT Unit Belting & Knee Bracing
MS Angle Iron (50X50x6 mm), Length : 2800 mm x 4 Nos
MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos
GO AB Switch Unit (11kV, 400A, 25 KA )
D.O Fuse Unit
Surge Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete (i/c Stay Clamp)
Pipe Earthing Set
GI Wire 6 SWG For Earthing
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Copper Thimble
Danger Plate
Red Oxide
Aluminium Paint.
Complete erection, testing, commissioning of 11KV, CT/PT units complete in all respect
Trasportation Charges
Manual carriage of material CT/PTs Av. Lead 1.8 KM i.e. 1x1.800=1.80 KM
Grand Total
Add. Freight & Insurance Charges
G. Total
Superintending Engineer,
Operation Circle, HPSEBL,
Kasumpti, Shimla-9.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.06 MB
SBD.rar
Tender Documents • 0.89 MB
BOQ_190648.xls
BOQ • 0.27 MB
EstimatedCost20.xls
Additional Documents • 0.08 MB
GuidelineforERA.pdf
Additional Documents • 2.33 MB
Download all tender documents and submit your bid