Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹1.5 Cr+₹12.5 L (9.24%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | ₹1.5 Cr+₹12.5 L (9.24%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹1.8 Cr+₹45.7 L (33.8%)Rejected-Finance PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | ₹1.8 Cr+₹45.7 L (33.8%) | L3 | Rejected-Finance Not Being Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
24 May 2025, 6:00 pmClosed
CHEIF ENGINEER CECG GOA
CHEIF ENGINEER CECG GOA 403806
PROVISION OF ADMINISTRATIVE SUPPORT BUILDING FOR RADAR STATION AT ICGS VERAVAL
2025_MES_702806_1
83093/E8
Open Tender
Civil Works
Lump-sum
365 days
PORBANDAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE I CG PORBANDAR
₹2.2 L
14 Jul 2025
28 Mar 2025
31 May 2025
28 Mar 2025
24 May 2025
5 May 2025
Amount
SCHEDULE "A" Part - I (BUILDING / STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II (SITE CLEARANCE, AREA DEVELOPMENT, EXCAVATION & EARTHWORK) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/PATH/CULVERT/HARDSTANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (LIGHTNING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (SPECIAL WORKS) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- XI (SUMMER APPLIANCES) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
INTERNAL ELECTRIFICATION:- S & F LED light fitting 10 Watt 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete.
S&F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make:Luker or Equivalent
S & F Vertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP MCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.
M&L for TV socket TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified.
M&L for telephone jak with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified.
Supply and lay coaxial cable for TV Cable drawn through conduit
SEWAGE DISPOSAL:- M & L for DWCPE (SN8) 180mm OD/160mm ID with intregral non-detachable socket having a minimum ring stiffness of 4 KN/Sqm as per IS-16098 Part-I laid and jointed complete complete all as specified.
EXTERNAL ELECTRIFICATION:-Supply, install, testing and commisioning of Distribution transformer stepdown Level 2 (Prevously EE Level 3 before Amendment No 4 to IS 1180 ), 11KV0.433KV , Three Phase complying with IS: 1180/IEC-76(Part-1) 2014 with latest ammendments, Outdoor type double copper wound suitable for 50 Hz system of capacity 100 KVA, oil immersed naturally cooled delta connected on HT side and star connected on LT side ,Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5% in step of 2.5 %. Losses should be confined to the limits specified as follows: maximum allowable losses at full load (100%) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 watts respectivly as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028 and comprising with the following standerd fittings/Technical specifications : - (a) Lifting lug for transformer and tank. (b) Earthing terminal rating and diagram plate. (c ) Air release device. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve. (f) Conservator tank with oil level indicator (g) Silica jel breather (j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335. (k) Type of connection Delta/Star (l) Type of cooling: Oil and Natural Air. (m) Vector group:DYN 11. (n) Temperature rise over an ambient of 50 °C maximum. (o) Cable end box on both side for HT/LT cables of suitable size. (p) Provision of thermometer with pocket. (q) Provision of oil and winding temperature gauge.
S & F for Load break switches outdoor type IP 55 protection LBS are used for 11KV load isolation, primarily to protect transformers during heavy load or isolate power during maintenance works. Air insulated LBS switches operate at 11KV with ratings at 630A, 26.3KA Short circuit rating, 28KV High Voltage withstand and 78KV impulse voltage withstand capacity, as per IS-9920, IEC265
M & L in for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, fabricated of Thermoplastic (Polycarbonate), insulated, shock proof, dust proof, water proof, anticorrosive and confirming to IP 55 complete including Aluminium bus bar of 200 Amp capacity 4 strip mounted on porcelain insulated & enclosed in chamber & connection from incoming and outgoing with comprising of following :- NOTE : (a) The contractor should submit the IP Test Report and Verification of shor circuit withstand Test report issued by CPRI in respect of LT Panel (b) Contractor shall submit the drawing for approval prior to place the order. Make of Panel : Hensel/C&S/L&T Make of MCCB/MCB : Legrand/L&T/Schneider/Hager (a) Incoming - MCCB 100 Amp FP 18 KA- 01 Nos (b) Outgoing - MCCB 63 Amp FP 18 KA- 02 Nos (c ) MCB 40 Amp TP 16 KA- 02 No (d) MCB 16 Amp FP 10 KA- 01 No (d) Digital panel meter for Amp, Volt,KWH, power factor and other parameter flush mounting of size 96 x96 mm (f) Aluminium Bus bar RYB and N of 200 Amp capacity one set
Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 62.5 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz supply, 1500RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with inbuilt fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following. (A)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. (a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows.
(l) Battery charging alternator. (m) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (n) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (o) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (p) Interconnecting copper cabling of adequate capacity batteries control. (q) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (r) Self starter 12 volts DC. (s) Electric operated electronic governor. (t) Fuel injection pump. (u) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 12v -24V Battery as per OEM instruction (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (v) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop (w) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads.
(x) Battery:-12V-24 volts, as per OEM recommendation maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (y) Fuel tank: 12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed. (z) Isolator panel with 100 amp MCCB (aa) Auto logic panel for automatic stat (B) Alternator: Alternator suitable rated for 62.50 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/ crompton/ kirloskar/ Greaves (C) Acoustic Enclosure:- M & L for acoustic enclosure for the above 62.50 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :- (i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton. (D) AMF Control panel:- Factory fabricated cubicle type, indoor type, IP-43, AMF control panel,
(E) AMF control circuit with 4 pole MCCB 100 Amps - 2 nos, with ultimate breaking capacity Icu-16 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts ,-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc. (F) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate. Note :- DG set should be as per CPCB -4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981.
FIRE FIGHTING:- Fire Extinguisher Dry Chemical powder [ABC] type 6 Kg capacity.confirming to IS 15683, discharge time less than 18 secs, controllable discharge mechanism, Range minimum 4 mtrs, applicable on class A,B,C complete all as spd and directed ( Location: Entry, Exit, AC Plant Room, Projector Room)
RO PLANT:- S&F Domestic type RO water purifier fully automatic operation with auto start and auto off secondary purification by UF after RO ensuring enhanced water quality through out service cycles and with TDS control system enabling maintaining of essential natural minerals in purified water, spin welded RO membrance housing to prevent tampering built in SMPS to operate with 160-250 V leak proof ABS construction for corrosion free life span suitable for all type of RAW water like borewell, shallow well, overhead storage tanks, water tankers all as specified and directed with following specification:- (i) Prefilter with connected accessories-01 No (ii) Purification capacity -15 ltrs/hour (iii) Max duty cycle -75 ltrs/day (iv) Storage tank capacity - 8 ltrs (v) RO membrane - 1812-75 GPD (vi) UF membrance - 0.01 micron (vii) Min inlet water pressure - 0.3 kg/cm2 (viii) Input voltage - 160-250 V DC (ix) Operation voltage -24 V DC (x) Dimension : L-340mm W-265mm H-505mm (xi) Net Weight - 6.5 Kg Make:- Kent RO (Elegant Lite)
Supply and installed voltage stablizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V without voltage stablized at 230V with accuracy of (+,-) 2.5 % and capacity 4 KVA .
Supply and installed voltage stablizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170V to 250V without voltage stablized at 230V with accuracy of (+,-) 2.5 % and capacity 5 KVA .
M & L in for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, fabricated of Thermoplastic (Polycarbonate), insulated, shock proof, dust proof, water proof, anticorrosive and confirming to IP 55 complete including Aluminium bus bar of 300 Amp capacity 4 strip mounted on porcelain insulated & enclosed in chamber & connection from incoming and outgoing with comprising of following :- NOTE : (a) The contractor should submit the IP Test Report and Verification of shor circuit withstand Test report issued by CPRI in respect of LT Panel (b) Contractor shall submit the drawing for approval prior to place the order. Make of Panel : Hensel/C&S/L&T Make of MCCB/MCB : Legrand/L&T/Schneider/Hager (a) Incoming - MCCB 160 Amp FP 25 KA- 01 Nos (b) Outgoing - MCCB 100 Amp FP 18 KA- 03 Nos (c ) MCB 40 Amp TP 16 KA- 02 No (d) MCB 16 Amp TP 10 KA- 02 No (d) Digital panel meter for Amp, Volt,KWH, power factor and other parameter flush mounting of size 96 x96 mm (f) Aluminium Bus bar RYB and N of 300 Amp capacity one set
JAY BHARAT METAL SUPPLIERS (BID ID -3299007)
M/S. P.M GODHANIYA (BID ID -3293550)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .