Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | ₹19.4 L Quoted ₹20.7 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹21.7 L+₹95,404 (4.60%)Rejected-Finance 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹21.7 L+₹95,404 (4.60%) | L2 | Rejected-Finance Other than lowest |
| 3 | l3₹22.0 L+₹1.2 L (5.91%)Rejected-Finance 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | ₹22.0 L+₹1.2 L (5.91%) | l3 | Rejected-Finance Other than lowest |
| 4 | L4₹22.9 L+₹2.2 L (10.5%)Rejected-Finance | ₹22.9 L+₹2.2 L (10.5%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹24.9 L+₹4.2 L (20.2%)Rejected-Finance | ₹24.9 L+₹4.2 L (20.2%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Nov 2022, 6:00 pmClosed
Maj Ashwin Awadh
Garrison Engineer West 62 Station Road Agra Cantt
REPAIR/ REPLACEMENT OF ELECTRICAL WIRING, SUB MAIN WIRING, DBS AND SECURITY LIGHTS WITH MISC E/M WORKS IN OTM ACCN AREA UNDER AGE E/M (W) OF GE (W) AGRA.
2022_MES_560711_1
8012/923/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹80,000
16 Dec 2022
1 Nov 2022
26 Nov 2022
1 Nov 2022
24 Nov 2022
16 Nov 2022
Amount
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including shunkeen boxes fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/colour/plaster to match with the existing location spot complete all as specified & directed.
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
All as per item No-2 above but for light point controlled by two nos 2 way switchs complete all as specified & directed.
All as per item No-2 above but for one socket out let 3/5 pin, 5/6 Amps controlled by 1 one way on the same board with other switches complete all as specified & directed.
All as per item No-2 above but for one socket out let 3/5 pin, 5/6 Amps controlled by 1 one way switch on independent board below the switch board of light points in same vertical plane complete all as specified & directed.
All as per item No-2 above but for one socket out let 3/5 pin, 5/6 Amps controlled by one 1way switch on independent board not below the switch board of light points in same vertical plane complete all as specified & directed.
All as per item No-2 above but using 2.5 sqmm PVC FRLS insulated stranded copper cunductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. NOTE-For item no 3 to 7-: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators, amp holders, light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
M&L for point wiring surface type with 1.50sqmm PVC insulated, unsheathed, single core, multistranded copper conductor FRLS cable 1100 volts grade including 1.5sqmm PVC insulated unsheathed stranded copper conductor FRLS cable as earth continuity conductor drawn in and including PVC casing & caping of suitable size but not less than 20mm width with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including all fixing accessories and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing for the one light/ fan/ bell point controlled by one 1 way switch 5/6 Amps complete all as specified & directed.
All as per item No-8 above but for light point controlled by two nos 2 way switchs complete all as specified & directed.
All as per item No-08 above but for one socket out let 3/5 pin, 5/6 Amps controlled by one 1 way switch on the same board with other switches complete all as specified & directed.
All as per item No-08 above but for one socket out let 3/5 pin, 5/6 Amps controlled by one 1 way switch on independent board but not below the switch board of light points in same vertical plane complete all as specified & directed.
All as per item No-08 above but using PVC FRLS cable of size 2.5 sqmm for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed.
S&F switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed. Make: Anchor Cat No.38058 or equivalent as approved by GE.
Supply and fix socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed. Make: Anchor Cat No.38320 or equivalent as approved by GE.
Supply and fix switch piano, flush type, single pole, 20 Amps one way, 230 volts complete all as specified and directed. Make: Anchor Cat No.39991 or equivalent as approved by GE.
Supply and fix socket outlet, multi-purpose 3 pin 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed. Make: Anchor Cat No.39994 or equivalent as approved by GE.
S&F switch, bell push button, single pole, 5/6 Amps, one way, 230 Volts complete all as specified and directed. Make -Anchor CAT Part No-38047 or equivalent as approved by GE.
S & F switch piano, flush type single pole, two way 5 Amp. complete all as specified and directed. Make -Anchor CAT Part No-38025 or equivalent as approved by GE.
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed. Make -Anchor CAT Part No-39072 or equivalent as approved by GE.
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed. Make: Anchor Cat No. 39797/ 39800 or equivalent as approved by GE.
Supply & fix rotory stepped type electronic fan regulator mini flush type 100 watt 230 Volts complete all as specified & directed. Make: Anchor Cat No.38284/38660 or equivalent as approved by GE.
Supply and fix electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified & directed. Make:- Anchor / Cona / Plaza as approved by GE.
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, to be terminted in moduler metal GI flush box and its cover plates for fixing moduler switches/ socket / regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
All as per item No-23 above but for one socket out let 3/5 pin, 5/6 Amps controlled by 1 one way on the same board with other switches complete all as specified & directed.
All as per item No-23 above but for one socket out let 3/5 pin, 5/6 Amps controlled by one 1way switch on independent board not below the switch board of light points in same vertical plane complete all as specified & directed.
All as per item No-23 above but using 2.5 sqmm PVC FRLS insulated stranded copper cunductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. NOTE-For item no 23 to 26-: (i) Moduler metal GI flush box and its cover plates for fixing moduler switches/ socket / regulators shall be measured and paid sepertly under respective item of BOQ. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/ Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (iii) Fittings like switches,sockets, regulators, amp holders, light foittings shall be measured and paid for separately under appropriate item of BOQ (iv) The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
S&F moduler metal GI flush box including its cover plates with frame for fixing moduler switches/ socket / regulators 3 module, fixed on wall making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface complete all as specified & directed.
All as per item No-27 above but 6 module
All as per item No-27 above but 12 module
All as per item No-27 above but 18 module
S&F switch modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed Make-Legrand/crabtree as per sample at site as approved by GE.
S&F socket outlet, 6 Amps, modular type, 2 module 230 volts complete all as specified and directed. Make-Legrand/crabtree as per sample at site as approved by GE.
S&F switch modular type, single pole, 16 Amps one module,one way 230 volts complete all as specified and directed. Make-Legrand/crabtree as per sample at site as approved by GE.
S&F socket outlet, 6/16 Amps, modular type, 2 module 230 volts complete all as specified and directed. Make-Legrand/crabtree as per sample at site as approved by GE.
S&F rotory stepped type electronic fan regulator modular type,Single module 120 watt 230 Volts complete all as specified & directed. Make-Legrand/crabtree as per sample at site as approved by GE.
Taking down existing old/ unserviceable sub main wiring along with fitting/fixtures existing of any type and description, removal of teak wood batten/ PVC pipe/ PVC casing & caping and making good disturbed surfaces of walls, ceilings etc by cement/colour/plaster to match with the existing location spot complete all as specified and directed.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for in replacement of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 2.5 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 2.5 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Supply & fix, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts complete all as specified & directed Make:- Legrand cat part No-6078 41 or equivalent model of make Siemens/ Schneider as approved by GE.
S& F in replacement surface/wall mounting LED batten 20 watt luminaire having Aluminium housing and integrated electronic driver with mounting accessories,6500K color temprature complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-ENDURALINEARNEOBS22WLED830SPCWH, Phillips/ Bajaj/ CG or equivalent as approved by GE.
S & F in replacement, outdoor street light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- ENDURAPEARLNEOSL40WLED757PASYTOPC,Phillips cat part No. BRP052 LED 036 CW HP SLA FG S1 PSU GR or equivalent as approved by GE.
S & F in replacement, surface mounting type bulkhead 10 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- Cat part No FT10WLED857SSYMBOPC or equivalent model of make Philips/ Bajaj/ Crompton Greaves as approved by GE.
S& F in replacement, surface/ recased mounting type 34 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- PLUTONEOPLR34WLED857S or equivalent model of make ,Philips/Bajaj/ Crompton Greaves as approved by GE.
S&F in replacement, surface round mounting type 12/15 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-EDGEPRORDDLR12WLED857S or equivalent as approved by GE.
S&F in replacement, surface square mounting type 12 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-EDGEPROSQDLR12WLED857S or equivalent model of make Philips/Bajaj/ Crompton Greaves as approved by GE.
S&F in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells cat part No- LHECDEFOIH1W028 or equivalent model of make ,Philips/Bajaj/ Crompton Greaves as approved by GE.
S&F in replacement MCB DB 4 way sheet metal enclosure triple pole and neutral 415 volts with 100 Amp standard copper bus bar IP-43, IK-09 with metal doors of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mouting type double door factory fabricated complete as per IEC 61439-3 without MCB but with enclosue blank plate complete all as specified and directed . Make:- Legrand CAT No.5076 70 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F in replacement MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB & MCCB but with enclosue blank plate complete all as specified and directed . Make:- Legrand CAT No.507725 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doorscomplete all as specified and directed. Make:- Legrand Cat Part No. 507611 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 4 way with 100 amps rated copper rated bus bar 240 volts IP-43, IK-09 complete all as specified and directed. Make:- Legrand Cat Part No. 507610 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F MCCB 4 pole 100 to 125 Amp Icu 16 Kilo Amp and Ics 100% of Icu with adjustable 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB. Make:- Legrand CAT No.4200 15 to 4200 16 or equivalent model of make Siemens/ Schneider as approved by GE. Note :- For item No 48 to 51 : Taking down of distribution board, MCB/MCCB/Isolator houses and disconnections are deemed to be including in quoted rates.
S&F Isolator TPN, 4 Pole, 415 Volts, 50 Hz AC Supply , 63 to 100 Amps, IP-20 as per IEC 60947-3 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4065 20 to 4065 22 or equivalent model of make Siemens/ Schneider as approved by GE.
S&F Isolator SPN , 40 Amps, 240 volts, 50Hz, IP-20 as per IEC 60947-3 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 406501 or equivalent model of make ABB/ L&T/ Schneider as approved by GE.
S&F MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4085 87 to 4085 95 or equivalent model of make Siemens/ Schneider as approved by GE.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.0mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.50M below the normal ground level, GI wire 4.0mm dia from earth plate/ electrode to test point (upto max distance of 7.50M is included in unit rate) and connected to earth plate & earth test point by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe light grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be renderd 12mm thick plaster in CM (1:4), funnel with wire mesh of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and connection from DB to earth electrode with same GI wire alongwith protection pipe and testing on completion complete all as specified and directed.
S S TRADERS
M/S OM Enterprises
M/S SHRINATH CONTRACTION
M/s Sharda Costruction Company
M/s UNITED ENGINEERS
M/S Mamta Electricals
Allied Builders
M/S R.S. CONTRACTOR & SUPPLIER
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .