Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC | L1 | Accepted-AOC Ok | |
| 2 | L2₹22.9 L+₹2.9 L (14.6%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹23.0 L+₹3.1 L (15.4%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹23.7 L+₹3.7 L (18.5%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹25.5 L+₹5.5 L (27.6%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
9 Mar 2023, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
COMPRHENSIVE MAINT INCLUDING REPAIR/ REPLACEMENT OF UNSERVICEABLE PARTS OF COLD ROOMS, TOWER ACS, DUCTABLE ACS AND CONNECTED MISC E/M WORKS AT BASE HOSPITAL, AFTC AND AFMSD UNDER GE (E/M) BHDC-10
2023_MES_580059_1
GE/BH-117/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D Category c(i)
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSPITAL DELHI CANTT
₹90,000
Yes
31 Mar 2023
9 Feb 2023
11 Mar 2023
9 Feb 2023
9 Mar 2023
24 Feb 2023
Amount
S&F in repair Controller Suitable for Cold Chamber of any make and model complete all as specified and directed.
S&F in repair IDU axial fan complete set suitable for cold room of following model complete all as specified and directed:-
IDU axial fan complete Set, suitable for cold chamber (Model No-RAUH0-2012 KP-I).
IDU axial fan complete Set, suitable for cold chamber (Model No RAUH0-1015 KP-I).
IDU axial fan complete Set, suitable for cold chamber (Model No RAUH0-1012 KP-I).
S&F in repair Outdoor Unit Fan Motor SP 230V/415V Suitable for cold chamber of following model complete all as specified and directed:-
Outdoor Unit Fan Motor, SP 230V/415V suitable for cold chamber (Model No RUAH0-2012 KP-O).
Outdoor Unit Fan Motor, SP 230V/415V suitable for cold chambers (Model No RUAH0-1015 KP-O).
Outdoor Unit Fan Motor, SP 230V/415V suitable for cold chambers (Model No RUAH0-1012 KP-O).
S&F in repair ODU Fan Blade Set suitable for fan motor of sweep- 300mm of following model complete all as specified and directed:-
ODU Fan Blade Set suitable for cold chamber (Model No RUAH0-2012 KP-O).
ODU Fan Blade Set suitable for cold chamber (Model No RUAH0-1015 KP-O).
ODU Fan Blade Set suitable for cold chamber (Model No RUAH0-1012 KP-O).
S & F in replacement Compressor working on 230 Volt, AC, single phase complete duly filled with capila 'D' including supply and charging the refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber of following models complete all as specified and directed:-
Compressor suitable for outer door unit 40000 BTU/Hour ( Cold chamber Model No- RUAH04012KP-O).
Compressor suitable for outer door unit 20000 BTU/Hour ( Cold chamber Model No- RUAH0-2012 KP-O).
Compressor suitable for outer door unit 15000 BTU/Hour ( Cold chamber Model No- RUAH01015KP-O).
Compressor suitable for outer door unit 10000 BTU/Hour ( Cold chamber Model No- RUAH01012KP-O).
S&F in repair Evaporator Coil suitable for Cold Chamber IDU of following models complete all as specified and directed:-
Evaporator Coil suitable for cold chamber (Model No RUAH0-2012 KP-I).
Evaporator Coil suitable for cold chamber (Model No RUAH0-1015 KP-I).
Evaporator Coil suitable for cold chamber (Model No RUAH0-1012 KP-I).
S&F in repair Condenser Coil, Size 24 inch and 2 Row suitable for Outdoor Unit of Cold Chamber of following models complete all as specified and directed:-
Condenser Coil suitable for cold chamber (Model No RUAH0-2012 KP-O).
Condenser Coil suitable for cold chamber (Model No RUAH0-1015 KP-O).
Condenser Coil suitable for cold chamber (Model No RUAH0-1012KP-O).
S&F in repair Service Valve 7/8'' suitable for ductable AC/ cold chamber of any make and model complete all as specified and directed.
S&F in repair Service Valve 5/8'' suitable for ductable AC/cold chamber of any make and model complete all as specified and directed.
S&F in repair Service Valve 6/8'' suitable for ductable Ac/cold chamber of any make and model complete all as specified and directed.
S&F in repair Service Valve 3/8'' suitable for ductable AC/cold chamber of any make and model complete all as specified and directed.
S&F in repair Service Valve 1/2'', 1/8'' suitable for ductable AC/cold chamber of any make and model complete all as specified and directed.
S&F in repair copper tubing 7/8" dia & wall thickness- 20 SWG with required insulation complete all as specified and directed.
S&F in repair copper tubing 6/8" dia & wall thickness- 22 SWG with required insulation complete all as specified and directed.
S&F in repair copper tubing 5/8" dia & wall thickness-20 SWG with required insulation as per site requirement complete all as specified and directed.
S&F in repair copper tubing 3/8" dia & wall thickness- 16 SWG with required insulation complete all as specified and directed.
S & F in replacement copper tubing ½” dia & wall thickness - 22 SWG with required insulation complete all as specified & as directed.
S & F in replacement copper tubing 1/4” dia & wall thickness - 22 SWG with required insulation complete all as specified & as directed.
Supply and charging of refrigerant gas R-22, of suitable grade after carrying out the pressure test with nitrogen and rectify the leakage of cold chamber/ductable AC/tower ac complete all as specified and directed.
Supply and charging of refrigerant gas of suitable grade R-407C after carrying out the pressure test with nitrogen and rectify the leakage of cold chamber/ductable AC/tower ac complete all as specified and directed.
Supply and charging of refrigerant gas of suitable grade R-410 after carrying out the pressure test with nitrogen and rectify the leakage of cold chamber/ductable AC/tower ac complete all as specified and directed.
S&F in repair strainer 3/8" for cold chamber of suitable size and make as per existing site complete all as specified and directed. Make-Blue Star/Carrier/ Ice make.
S&F in repair strainer 5/8" for cold chamber of suitable size and make as per existing site complete all as specified and directed. Make-Blue Star/Carrier/ Ice make.
S&F in repair watch timer switch single phase 2400 Hrs, 16 Amps for cold chamber including necessary wiring complete all as specified and directed.
S&F in repair expansion valve suitable for cold chamber of suitable size as per site requirement complete all as specified and directed. (Model No. RUAHO-1012 KP-1).
S&F in repair expansion valve suitable for cold chamber of suitable size as per site requirement complete all as specified and directed. (Model No. RUAHO-1015 KP-1).
S&F in repair expansion valve suitable for cold chamber of suitable size as per site requirement complete all as specified and directed. (Model No. RUAHO-2012 KP-1).
M&L for servicing, and cleaning of condenser/evaporator of out door and indoor unit of cold chamber respectively with suitable chemical detergent and acid using pump, washing the same with water by using pump set of 110 feet head and making clear and clean all the tubes , fins and other parts and then clear with suitable dry air blower, Checking and tightening of all electrical connection and making fully serviceable including top up of refrigerant Gas complete all as specified and directed.
Attending the break down/ complaint of all nature including wiring of panels and all others mentioned below for walk in cooler of base hospital and carry out the required repairs, on all days including Sunday and holidays complete all as specified and directed. Note- (i)The spare parts required to be replaced shall be measured and paid separately as "Supply only" under respective item of this Schedule. (ii) Adequate resources shall be deployed by the contractor for attending day to day defect being an essential installation. (iii) All complaint/repairs shall be attended within 06 Hour failing which a recovery of Rs 1000/- per day per complaint shall be made from contractor dues.
Supply only in repair single phase preventer VSP-II complete all as specified and directed.
supply only in repair over load relay type MNX 10, 15A , 3 phase complete all as specified and directed.
supply only in repair over load relay type MNX 18, 15A , 3 phase complete all as specified and directed.
supply only in repair over load relay type MNX 32, 15A , 3 phase , 220V complete all as specified and directed.
supply only in repair over load relay type MNX 25, 15A , 3 phase, 220V complete all as specified and directed.
Supply only in repair running capacitor 50 + 5 MFD complete all as specified and directed.
M&L in repair sub main wiring with 2 runs of 2.5 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, concealed , PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 2.5 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 2.5 Sqmm cable and one run of 2.5 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length).
M&L in repair sub main wiring with 2 runs of 6.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, concealed, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 6.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 6.0 Sqmm cable and one run of 6.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length).
M&L for servicing and cleaning of condenser/evaporator of out door and indoor unit of ductable AC respectively with suitable chemical detergent and acid using pump, washing the same with water by using pump set of 110 feet head and making clear and clean all the tubes, fins and other parts and then clear with suitable dry air blower, Checking and tightening of all electrical connection and making fully serviceable including top up of refrigerant Gas complete all as specified and directed.
Attending the break down/ complaint of all nature including wiring of DB for ductable ac of base hospital and carry out the required repairs, on all days including Sunday and holidays complete all as specified and directed. Note- (i)The spare parts required to be replaced shall be measured and paid separately as "Supply only" under respective item of this Schedule. (ii) Adequate resources will be deployed by the contractor for attending day to day defect being an essential installation. (iii) All complaint/repairs shall be attended within 06 Hour failing which a recovery of Rs 1000/- per day per complaint shall be made from contractor dues.
S & F in replacement scroll type Compressor for ductable AC , working on 440 Volt, AC, three phase complete duly filled with capila 'D' including supply and charging the suitable refrigerant gas to the required capacity including flushing the complete refrigerant system after leak detection and replacing the filter complete for cold chamber of following models complete all as specified and directed:-
Compressor suitable for out door unit of ductable AC of cap 8.5 TR (102000 BTU/HR), (Ductable AC Model No- DSA1021R3-OA).
Compressor suitable for out door unit of ductable AC of cap 8.75 TR (102000 BTU/HR), (Ductable AC Model No- ACDCUSC-875DGR407IM).
Compressor suitable for out door unit of ductable AC of cap 8.5 TR (102000 BTU/HR), (Ductable AC Model No- DSA1021R2-OT).
Compressor suitable for out door unit of ductable AC of cap 5.5 TR (66000 BTU/HR) (Ductable ac Model No- DSA661R3-OA).
Compressor suitable for out door unit of ductable AC of cap 5.5 TR (66000 BTU/HR) (Ductable ac Model No- DSA661R2-O).
Compressor suitable for out door unit of ductable AC of cap 3 TR (9000 BTU/HR), (Ductable ac Model No- DSA361R2-O).
All as per srl item No 40.00 here-in-before but compressor of Capacity 2 TR working on 230 V, AC, single phase (Ductable AC Model No - DSA522R3-O) complete all as specified and directed.
S&F in repair Outdoor Unit Fan Motor of following models ductable AC complete all as specified and directed:-
Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No - DSA1021R3-OA).
Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM).
Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No - DSA1021R2-OT).
Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No -DSA661R3-OA).
Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No-DSA361R2-O).
Outdoor Unit Fan Motor 3 Phase, 415V, Suitable for ductable AC (Model No - DSA661R2-O).
All as per item No. 42.00 here in before but fan Motor of single Phase, 230V, Suitable for ductable AC (Model No DSA522R3-O).
S&F in Repair outdoor unit fan Blade Suitable for any make and model of ductable type AC of following model complete all as Specified and directed:-
Outdoor Unit Fan blade Suitable for ductable AC (Model No - DSA1021R3-OA).
Outdoor Unit Fan blade Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM).
Outdoor Unit Fan blade suitable for ductable AC (Model No - DSA1021R2-OT).
Outdoor Unit Fan blade suitable for ductable AC (Model No -DSA661R3-OA).
Outdoor Unit Fan blade Suitable for ductable AC (Model No-DSA361R2-O).
Outdoor Unit Fan blade Suitable for ductable AC (Model No - DSA661R2-O).
ODU fan blade Suitable for ductable AC (Model No DSA522R3-O).
S&F in repair Indoor Unit blower of following models ductable AC complete all as specified and directed:-
Indoor unit blower Suitable for ductable AC (Model No - DSA1021R3-OA).
indoor Unit blower Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM).
Indoor Unit blower Suitable for ductable AC (Model No - DSA1021R2-OT).
Indoor Unit blower Suitable for ductable AC (Model No -DSA661R3-OA).
Indoor Unit blower Suitable for ductable AC (Model No-DSA361R2-O).
Indoor Unit blower Suitable for ductable AC (Model No - DSA661R2-O).
Indoor unit blower Suitable for ductable AC (Model No DSA522R3-O).
Supply and fixing in repair Indoor Unit Blower Motor of following models ductable AC complete all as specified and directed:-
Indoor unit blower Motor 1 Phase, 230 V, Suitable for ductable AC (Model No - DSA1021R3-OA).
indoor Unit blower Motor 1 Phase, 230V, Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM).
Indoor Unit blower Motor 1 Phase, 230 V, Suitable for ductable AC (Model No - DSA1021R2-OT).
Indoor Unit blower Motor 1 Phase, 230 V, Suitable for ductable AC (Model No -DSA661R3-OA).
Indoor Unit blower Motor 1 Phase, 230V, Suitable for ductable AC (Model No-DSA361R2-O).
Indoor Unit blower Motor 1 Phase, 230V, Suitable for ductable AC (Model No - DSA661R2-O ).
Indoor unit blower Motor of 1 Phase, 230V, Suitable for ductable AC (Model No DSA522R3-O).
S&F in repair expansion valve of following models ductable AC complete all as specified and directed:-
Expansion valve Suitable for ductable AC (Model No - DSA1021R3-OA).
Expansion valve Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM).
Expansion valve Suitable for ductable AC (Model No - DSA1021R2-OT).
Expansion valve Suitable for ductable AC (Model No -DSA661R3-OA).
Expansion valve Suitable for ductable AC (Model No-DSA361R2-O).
Expansion valve Suitable for ductable AC (Model No - DSA661R2-O).
Expansion valve Suitable for ductable AC (Model No DSA522R3-O).
S&F in repair evaporative coil for indoor unit of ductable AC of following models complete all as specified and directed:-
Evaporative coil Suitable for ductable AC (Model No - DSA1021R3-OA).
Evaporative coil Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM).
Evaporative coil Suitable for ductable AC (Model No - DSA1021R2-OT).
Evaporative coil Suitable for ductable AC (Model No -DSA661R3-OA).
Evaporative coil Suitable for ductable AC (Model No-DSA361R2-O).
Evaporative coil Suitable for ductable AC (Model No - DSA661R2-O ).
Evaporative coil Suitable for ductable AC (Model No DSA522R3-O).
S&F in repair condenser coil for outdoor unit of ductable AC of following models complete all as specified and directed:-
Condenser coil Suitable for ductable AC (Model No - DSA1021R3-OA).
Condenser coil Suitable for ductable AC (Model No - ACDCUSC-875DGR407IM).
Condenser coil Suitable for ductable AC (Model No - DSA1021R2-OT).
Condenser coil Suitable for ductable AC (Model No -DSA661R3-OA).
Condenser coil Suitable for ductable AC (Model No-DSA361R2-O).
Condenser coil Suitable for ductable AC (Model No - DSA661R2-O).
Condenser coil Suitable for ductable AC (Model No DSA522R3-O).
Supply only in replacement gas filter/ dryer 5/8" suitable for ductable AC of any make and model complete all as specified and directed.
Supply only in replacement PCB for IDU suitable for ductable AC of any make and model complete all as specified and directed.
Supply only in replacement capillary thermostat for controlling temperature complete all as specified and directed.
Supply of indoor with cooling Coil, blower motor, blower with PVC accessories for cold room 24000 BTU capacity complete all as specified and directed.
Supply of indoor with cooling Coil, blower motor, blower with PVC accessories for cold room 15000 BTU capacity complete all as specified and directed.
Supply of indoor with cooling Coil, blower motor, blower with PVC accessories for cold room 10000 BTU capacity complete all as specified and directed.
Supply only in repair power contactor 3 phase 220 Volt MNX-18 complete all as specified and directed.
Supply only in repair power contactor 3 phase 220 Volt MNX-25 complete all as specified and directed.
M&L for servicing and cleaning of York mortuary Chamber for capacity of 6 body respectively with suitable chemical detergent and acid using pump, washing the same with water by using pump set of 110 feet head and making clear and clean all the tubes, fins and other parts and then clear with suitable dry air blower, Checking and tightening of all electrical connection and making fully serviceable including replacement of unserviceable parts, top up of refrigerant Gas complete all as specified and directed.
RUCHIKA ENGG.WORKS
YASHVI ENGINEERS
Singh Associates
SANJEEV ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .