| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.9 L+₹1.8 L (8.06%)Rejected-Finance GROUND FLOOR MH ROAD UDHAMPUR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹25.6 L+₹3.5 L (15.9%)Rejected-Finance 20 JAIN BAZAR JAMMU 180003 J K | JAMMU | JAMMU | J K | 180003 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹32.4 L+₹10.3 L (46.7%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹32.7 L+₹10.6 L (48.0%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
28 Sept 2024, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur, PO-Garhi, PIN-182121
Repair/maint of AMF panel for DG sets alongwith allied works installed at Generation Section of RAC Sub Divn and Repair/maint of street lights, Control switches alongwith allied works at JNE area under GE (Utilities) Udhampur
2024_MES_668706_1
GE/U- -2024-25
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹70,000
4 Nov 2024
31 Aug 2024
5 Oct 2024
31 Aug 2024
28 Sept 2024
14 Sept 2024
Amount
Taking down carefully Unserviceable Security light 60 watt /Flood Light/ High Mast light fitting from pole/Structure and repair/replacement of worn out parts such as driver, SPD etc, cleaning of fittings, cover, copper wire,clamps, nuts and bolts, mounting bracket and re assembling the same after repair, testing and refixing in pole/other location including provision of necessery T & P like ladder/Boom Vehicle, tools ets as required for taking down and refixing of street light complete all as specified and directed by Engr-in-Charge. Note: - Replacement of defective spare parts of fitting (to make functional) will be measured and paid separately as supply only. However, cost of replacement screws, nuts, bolts, and cleaning of fittings shall be deemed to be included in quoted rate.
All as per serial item No 1.00 here-in-before but Secutiy light fittings 90 watt street light fitting complete all as specified and directed by Engr-in-Charge.
All as per serial item No 1.00 here-in-before but Flood light fittings 120 watt street light fitting complete all as specified and directed by Engr-in-Charge.
All as per serial item No 1.00 here-in-before but Flood light fittings 150 watt street light fitting complete all as specified and directed by Engr-in-Charge.
Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 2.5 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specefied and directed by Engr-in-Charge.
Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 4 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specefied and directed by Engr-in-Charge.
S&F in replacement modular box of size 333 x 233 x 120 mm made of FRP inpact resistance plastic & heat resistant materials including MCB SP 6 A, Connector terminal block 4 pole 16 A capacity and fixing to the street light or post top light pole with suitable sizes of clamps, nuts and bolts complete all as specefied and directed by Engr-in-Charge.
S&F in replacement 150 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 13200 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engr-in-charge.
All as per serial No 8.00 here-in-before but 120 watt LED flood light fitting complete all as specified and directed by Engr-in-Charge.
All as per serial No 8.00 here-in-before but 90 watt LED flood light fitting complete all as specified and directed by Engr-in-Charge.
All as per serial No 8.00 here-in-before but 60 watt LED flood light fitting complete all as specified and directed by Engr-in-Charge.
Supply and fix 15 Watt new generation, Post top lantern, energy saving, enviornmentla friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminarie with high power LEDs with IP-65 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 1500 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided all as specified and directed by Engr-in-Charge.
Supply and fix 11 Watt Fantasy Bollard LB14 Bollard, made of extruded aluminium housing, to redefine landscape with better light quality and enhance architectural dsign, rated IP65 all as specified & directed by Engr-in-Charge.
S&F LED Tiranga Rop light 18 Mtr, IP 65, Input Power 10W/meter, Input Voltage 220-240 VAC Input Frequency 50 Hzs, Input current 0.045 Amp/ Mte,Power factor 0.95, width of strip (+/- 0.1mm) 8mm length/reel-18mtrs, No of led per mtr 120 LED,LED Beam abgle 120 degree, Rope light per Colours length 6mtr orange, 6 mtr whit, 6mtr Green, Fixing method silicon clip, Ingrass Protection-IP-65, Ingrass protection method silicone tube,silicon tube dimention 11.5x5.5mm +/- 0.5mm, working temp range -20 degree celcius to +45 degree celious, working humidity range 10-90 RH and all as directed by Engineer in charge.
Dismantling of unserviceable steel tubular pole swaged pole/PCC pole including PCC complete with acessories complete all as specified and directed by Engr-in-Charge.
Dismantling of old unserviceable/broken/jointed ACSR conductor or earth wire from poles and removing from site of work complete all as specefied and directed by Engr-in-charge.
Taking down existing old cross arms of MS channel or angle sections etc all as specified and directed by Engineer-in-Charge.
Cleaning the existing exposed surfaces of steel tubular pole of 11.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of synthetic enamel paint (Aluminium shade) marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing & testing in replacement XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core laind in trenches or passing through pipe or fixed on poles complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 19.00 here-in-before but of size 16 Sqmm 4 core, complete all as specified and directed by Engr-in-Charge.
Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed by engineer in charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes foundations of poles/stays/pipes etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 22.00 here-in-before but depth exceeding 1.5 mtr and not exceeding 3 mtr complete all as specified and directed by Engr-in-charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed.
M&L for cement concreate 1:2:4 type D-2 (using 40 mm graded stone aggregate) as in coping etc including necessary form work and finishing the surface with cement mortar 1:4, 5mm thick finished to the portion of PCC muffs above ground level complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D-2 (using 40 mm grade stone aggregrate in foundation, mass concrate) as in foundation of poles & stay etc complete all as specified and directed by Engr-in-Charge.
Supply and Laying in replacement Galvanised iron steel tubes, ISI marked light grade of size 40 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe complete all as specified and directed by Engineer-in-Charge.
S&F in replacement erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-31, 9mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole complete all as specified and directed by Engr-in-Charge. Note: - Excavation and Earth Work, PCC in foundation shall be measured and paid for separately.
S&F in replacement Power contactor 3 phase 415 Volts, 40 Amps, coil voltage of rating 240 Volts including taking down old unserviceable power contactor complete all as specefied and directed by Engr-in-Charge.
S&F in replacement Power contactor 4 pole 240 Volts, 30 Amps , coil voltage of rating 240 Volts including taking down old unserviceable power contactor all as specified and as directed by Engr-In-Charge.
Supply only Driver for LED energy saving & enviornment area light fitting > 75 watts security light with active power factor correction (APFC) electronic driver. LED driver 75 Watt with operating voltage between 100-270 V of existing specifications & make complete all as specefied and as directed by Engr-in-charge.
Supply only Driver for LED energy saving & enviornment area light fitting > 45 watts security light with active power factor correction (APFC) electronic driver. LED driver 45 Watt with operating voltage between 100-270 V of existing specifications & make complete all as specefied and as directed by Engr-in-charge.
Supply only Surge protection 5 KV devices compatible with industrial & outdoor LED fixtures upto rated power of 45 W & up to 150 W with operating voltage between 100-270 V of existing specifications & make complete all as specefied and as directed by Engr-in-charge.
S&F in replacement MS Channel/angle iron/flat iron of required size and bend to shape as cross arms, bracing and support including, MS clamps back plates with bolts, nuts, and washers drilled for insulators including painting two coats of synthetic enemel paint (Aluminium shade) over a coat of red oxide primer complete all as specefied and directed by Engr-in-charge.
S&F in replacement Aluminium conductor steel reinforced (ACSR) any size on poles, stretched on LT poles without any kink and bends of various sizes complete including fixing to insulator with Aluminium binding wire complete all as specefied and directed by Engr-in-charge.
S&F in replacement MCCB four pole 63 Amps, 50 Hz with breaking capacity 16KA, Ics = 100% Icu , 415 Volts, Adjustable thermal & Fixed magnetic setting including making all incoming/ outgoing connections complete all as specified and directed by Engineer in Charge.
M&L in replacement for heat shrinkable End joint for PVC/XLPE insulated armoured cable of size upto 50Sqmm 3.5/4 core complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 39.00 here-in-before but LT cable size of 70 to 150 Sqmm, complete all as specified and directed by Engr-in-Charge.
M&L for road cuttig existing road for crossing of underground electric cable for laying of any size GI tubing including necessary excavation and earth work including repairing the same as per existing with pre mix bituminious carpet complete all as specefied and as directed by Engr-in-charge. Note: - Width of trench shall be 15 cm and depth shall be upto 30 cm.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth wire 4 mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 20 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge.
Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Carry out servicing from authorised rep or service engineer from the manufacturer of DG set of 320 KVA,capacity Make : Cummins all as per OEM instructions and directed by Engineer in Charge . Note : All the spare , parts , lubrication oil etc. has been measured and paid saperatly under respective item of schedule.
All as per item No.44 here in before but for 250 KVA DG set Make: Cummins complete all as specified & dirtectedby Engr-in-Charge.
All as per item No.44 here in before but for 125 KVA DG set Make: Cummins complete all as specified & dirtectedby Engr-in-Charge.
All as per item No.44 here in before but for 100 KVA DG set Make: Kirloskar complete all as specified & dirtectedby Engr-in-Charge.
All as per item No.44 here in before but for 62.5 KVA DG set Make: Kirloskar complete all as specified & dirtectedby Engr-in-Charge.
All as per item No.44 here in before but for 15 KVA DG set Make: Kirloskar complete all as specified & dirtectedby Engr-in-Charge.
Fuel filter primary and secondary suitable for DG Set capacity 250KVA to 320KVA complete all as specified & directed by Engr-in-Charge. Cat Part No : FS19634
Supply only lub oil filter body suitable for DG Set capacity 250KVA to 320KVA complete all as specified & directed by Engr-in-Charge. Cat Part No..LF9009
Supply only Air cleaner element suitable DG Set for capacity 10KVA to 320KVA complete all as specified & directed by Engr-in-Charge. Cat Part No.AF 26093.
Inner Air cleaner element suitable DG Set for capacity 10KVA to 320KVA complete all as specifed & directed by Engr-in-Charge. Cat Part No.AF 25911.
Supply only water filter body suitable for DG Set capacity Upto 10KVA to 320KVA complete all as specified & directed by Engr-in-Charge. Cat Part No. 04.270.01.0
Supply only fuel filter primary and secondary suitable for DG Set capacity Upto 125 kva complete all as specifed & directed by Engr-in-Charge. Cat Part No : F002H20 306.
Supply only lub oil filter body suitable for DG Set capacity Upto 125 kva complete all as specifed & directed by Engr-in-Charge. Cat Part No.06.436.01.0
Supply only Air cleaner element suitable DG Set for capacity Upto 125 kva complete all as specifed & directed by Engr-in-Charge. Cat Part No. 04.586.01000.
Supply and filling coolent for radiators. K Cool super Plus -50-50 premix complete all as specifed & directed by Engr-in-Charge. Cat part No.82.020.35.1.25. 25ltrs Packing.
M&L for replacement of Solenoied switch sutaible for 320 KVA DG Set complete All as specified & directed by Engr-in-Charge.
M&L for replacement of water circulating pump, for DG set of capacity 320 KVA including air supply connection pipe, clip, replacement of repair kit, calibration/ testing system complete, fitted with DG set properly in original position, checking the allignment, making proper all connection, testing for smooth opreation from authorised rep or service engineer from the manufacturer complete all as directed by Engr-in-Charge.
Material & labour for complete control wiring for connect all safety to controller/ AMF panel of 250 kva DG set & 320 KVA DG set carrying out complete servicing control panel, including checking and rewiring electrical circuit using FRLS copper conductor, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation, complete all as directed by Engr-in-Charge.
M&L for replacement of low level water safety relay for DG set of capacity upto 320 KVA of any make complete All as specified & directed by Engr-in-charge.
M&L for replacement of over heat safety relay for DG set of capacity upto 320 KVA of any make complete All as specified & directed by Engr-in-Charge.
M&L for replacement of Solenoied switch sutaible for 250 KVA DG Set complete All as specified & directed by Engr-in-Charge.
M&L for replacement of Ring gear of Flywheel suitable for DG set up to 320 kva complete All as specified & directed by Engr-in-Charge.
Supply and fixing in replacement of AVR S/F VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set upto 100 KVA complete all as specified and directed by Engineer -in-charge.
Supply and fixing in replacement of AVR S/F VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set above 125 KVA to 320 KVA complete all as specified and directed by Engineer-in-charge.
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model,size suitable for DG Set of capacity 15 to 320 KVA including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
Drain out the fuel from the fuel tank of DG set of any size/capacity and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements ccomplete all as specified and directed by Engr-in-Charge.
Disconnected and opening of self starter assemlly 12 volt for repair from DG set upto 125 KVA, repair unserveceable part of self starter suitable size as required on site complete all as specified and directed. Note :- Rate are deemed tobe include all worn out part including gear & winding complete all as specified & directed by Engr-in-Charge.
Disconnected and opening of self starter assemlly 24 volt for repair from DG set 250 kva & 320 KVA, repair unserveceable part of self starter suitable size as required on site complete all as specified and directed by Engr-in-Charge. Note :- Rate are deemed tobe include all worn out part including gear & winding complete all as specified and directed by Engr-in-Charge.
Supply & fix the following items of DG Set of various capacity complete all as specified & directed by Engr-in-Charge :-
Battery terminal, lug, bolts type suitable for heavy duty battery complete all as specified & directed by Engr-in-Charge.
Battery leads for copper conductor multiwired 50 Sqmm Single Core complete all as specified & directed by Engr-in-Charge.
Hinges for DG set door of any size, any type as required on site complete all as specified & directed by Engr-in-Charge.
Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as specified directed by Engr-in-Charge.
M&L for replacement of Lub oil pipe Cat Part No.02.078.05.0.00 complete all as specified & directed by Engr-in-Charge.
M&L for replacement of tappet valve Cat part No.181027 complete all as specified & directed by Engr-in-Charge.
M&L for replacement of Fuel Pipe for filter (7.5,14x14B,700PB) for BIO Diesel Cat Part No.02.102.03.0.00 complete all as specified & directed by Engr-in-Charge.
M&L for replacement of Fuel Pipe return ( FIP TO TANK) for BIO Diesel Cat Part No.02.102.13.0.00 complete all as specified & directed by Engr-in-Charge.
Only Supply of engine oil 15 W 40 in sealed Packing complete all as specified & directed by Engr-in-Charge.
M&L for replacement of three phase Digital Voltmeter 0-500V AC complete all as specified & directed by Engr-in-Charge.
M&L for replacement of three phase Digital Ammeter 30/5A(CTR) complete all as specified & directed by Engr-in-Charge.
Dismantling existing U/S battery charger & S/F of SMPS type battery charger suitable for 12 V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG Set is not in use complete all as specified & directed by Engr-in-Charge.
M&L for replacement of V belt for fan pulley (set of 2Nos) for DG set upto 320 KVA DG Set complete all as specified & directed by Engr-in-Charge.
M&L for replacement of V belt for alternator and water pump assembly for DG set upto 320 KVAcomplete all as specified & directed by Engr-in-Charge.
Material & labour for carrying out complete overhauling / servicing of DG set panel / AMF panel / control panel, including checking and rewiring faulty electrical circuit using 2.5 sqmm FRLS copper conductor, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation, complete all as specified & directed by Engr-in-Charge.
Supply and fixing of 'under/over voltage relay, 3 phase, 415 volts', for DG sets of capacity upto 320 KVA complete all as specified & directed by Engr-in-Charge.
Supply and fixing in replacement of battery voltage relay 12 VDC complete all as specified & directed by Engr-in-Charge.
Supply and fixing in replacement Battery 12volt 180 AH Code :- FXPO-MHD 1800 complete all as specified & directed by Engr-in-Charge.
Supply and fixing in replecement of 110 Amp,4pole, 415 Volts, 50 Hz Power contactor (MNX110) auxilary contact 2 NO + 2 NC, of coil voltage 240 Volts, complete all as specified & directed by Engr-in-Charge.
Supply and fixing in replecement of 160 Amp,4pole, 415 Volts, 50 Hz Power contactor (MNX140) auxilary contact 2 NO + 2 NC, of coil voltage 240 Volts,complete all as specified & directed by Engr-in-Charge.
Supply and fixing in replecement of Electronic Microprocessor based controller unit suitable to DG set controlls & commands of 62.5 KVA capacity with all listed parameters as per recomendation including testing complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replecement of Electronic Microprocessor based controller unit suitable to DG set controlls & commands capacity upto 250 KVA DG set with all listed parameters as per recomendation including testing complete all as specified and directed by Engr-in-Charge.
Supply and laying in trenches/wall/air armoured cable 1100 Volt multi stranded copper conductor cable of size 2.5 sqmm X 8 core for connection of AMF panel to DG set complete all as specified and directed by Engr-in-Charge.
Attending of any breakdown of standby supply in any location ,whenever required round the clock ,rectify the fault and restore the standby supply within three hour after receipt of complaint of any nature i.e. Engine, alternator,control panel,AMF panel etc complete all as specified and directed by Engr-in-Charge. Note -(i) The cost of replaced spare parts will be paid and measured seperatly. (ii) If complaint is not attended by contractor with in five hour the penality of Rs 500 / per hour to be imposed and amount of penality will be deducted from RAR. (iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock.
Material & labour for opening / taking out of injector of DG set of any type/make and capacity 15 KVA to 320 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making proper fuel connection, testing for smooth opreation complete all as specified and directed by Engr-in-Charge.
M&L in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set connection testing complete all as specified and directed.
Material & labour for complete overhauling,servicing of turbo charger, opening /taking out of turbo charger of DG set of 15 KVA to 320 KVA capacity ,disconnection of air supply connection pipe etc, including replacement of turbo charger repair kit, calibration/ testing of turbo charger system complete and re-assembling the same ,fitted with DG set properly in original position, checking the allignment, making proper all connection, testing for smooth opreation from authorised rep or service engineer from the manufacturer complete all as specified & directed by Engr-in-Charge.
M&L for capacity 15 to 320 KVA complete descaling of cooling system by radiwash with two times circulation of radiwash by means of running of engine & cleaning of fan blades, crankcase breather, radiator and its fins by means of high pressure air or water complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Copper tube (Thimbles) terminal heavy duty of size 185 Sq.mm complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Copper tube (Thimbles) terminal heavy duty of size 150 Sqmm complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Copper tube (Thimbles) terminal heavy duty of size 120 Sq.mm complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Copper tube (Thimbles) terminal heavy duty of size 95 Sq.mm complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Copper tube (Thimbles) terminal heavy duty of size 70 Sq.mm complete all as specified and directed by Engr-in-Charge.
Supply & Fix in replacement of change over switch FP 200 Amps, side handle, 415 Volt, 4 pole complete, all as directed by Engr-in-Charge.
Supply & Fix in replacement of change over switch FP 400 Amps, side handle, 415 Volt, 4 pole complete, all as directed by Engr-in-Charge.
Actuator ( in replacement) with spring (sedemac make) complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 25 x 4 mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge.
Note: - (i)On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge. (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) PCC pits extra cost of addtional length of watering pipe, bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length copper earth strip 25x4 mm.
Supply & fix in replacement for earth continuity conductor or main earthing lead fixed to wall on batton or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to pole or any other indicated situation for loop earthing etc as required with 25X4mm galvanised iron strip complete all as specified and directed by Engr-in-Charge.
Dismantling /opening of alternator of DG Set by disconnection of cable connections and flexible coupling, nuts/bolts and alternator foundation nut, bolts including strip opening of alternator and checking out burnt out parts of DG Sets of capacity 62.5 KVA to 320 KVA and taken back in temporary platform complete all as specified and directed by Engr-in-Charge.
Taking out burnt armature, winding wire and rewinding of armature with super enameled copper winding wire of existing gauge for 62.5 KVA to 320 KVA set wire DG sets complete all as specified and directed by Engr-in-Charge.
Taking out burnt field coil and rewinding of field coil with super enameled copper winding wire of existing gauge for 62.5 KVA to 320 KVAA sets complete all as specified and directed by Engr-in-Charge.
Insulation of armature with Class ‘B’ insulation and Varnishing of armature winding and drying up to desired temperature for 62.5 KVA to 320 KVA DG Sets complete all as specified and directed by Engr-in-Charge.
Insulation of field coils with Class ‘B’ insulation and varnishing of field coils and drying up to desired temperature for 250KVA to 320 KVA Alternator of DG Sets.
Burnt rectifier of size 2” x 2” x 24 plate (In replacement) set of three complete all as specified and directed by Engr-in-Charge.
Re-assembling of rotor and stator after rewinding and re-fixing of Alternator with Engine by assembling flexible coupling with alternator mounting with nuts, bolts including making cable connection complete including testing and commissioning at desire load of DG Set of capacity 62.5 KVA to 320 KVA complete all as specified and directed by Engr-in-Charge..
Supply & Fix in replacement Single core, Multi strand copper cable,70 sqmm, 1100 Volt suitable for existing DG set including propper connection from DG set to AMF Panel / Changeover complete all as specified and directed by Engr-in-Charge.
M/S DHARAM & SONS ENTERPRISES (BID ID -3102928)
A K JAIN AND SONS (BID ID -3101881)
PREM NATH KHAJURIA AND SONS (BID ID -3116403)
FANGALIA TRADERS (BID ID -3096918)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .