| 1 | L1₹8.3 LAccepted-Finance 26 1 BINDABAN PAL LANE KOLKATA 700003 | KOLKATA | KOLKATA | WEST BENGAL | 700003 | L1 | Accepted-Finance Offer lowest bid therfore Provisional order issued | |
| 2 | L2₹8.4 L+₹14,222 (1.72%)Rejected-Finance 46 SHYAMA PRASAD MUKHERJEE ROAD KOLKATA 700 026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹8.8 L+₹48,716 (5.88%)Rejected-Finance 221 3 SALT LAKE SECTOR II KOLKATA 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | L3 | Rejected-Finance that the bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
2 Jul 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE KNHED PW Dte
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
Electrical installation work with UPS backup system for installation of Holmium laser 100 watt at Urology OT under RG Kar MCH
2022_WBPWD_384529_1
WBPWD/EE/KNHED/NIQ-23/22-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,000
23 Aug 2022
10 Jun 2022
4 Jul 2022
13 Jun 2022
2 Jul 2022
13 Jun 2022
120 days
Amount
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/ABB/Cabtree) up to 160A [ D-11 /15] i) 6 way Enclosure
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.(Make- Legrand/ABB/Cabtree)[D-8/ 10] A) 160A
Supplying and fixing 240/415 V TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make- Legrand/ABB/Cabtree) [D-6/7] B) 63A
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/ABB/Cabtree) [ D-10 /14 ] i) 4 way Enclosure (607715)
Supplying and fixing 240/415 V FP MCB Isolator on din rail of existing DBs and necessary connection. (Make-Legrand) [D-5/ 6] ii) 63 A
Supplying and fixing 240/415 V SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make- Legrand/ABB/Cabtree) [D-6/ 7] ii) 32A
S& F 250V, 32A, 2P+E metallic plug and socket 32A DP DX isolator(make:- Legrand 0566 69/Siemens) with P17 Tempra For UPS line
Supplying and fixing 415V, 100A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (Make L&T/ABB/Siemens)
Supplying and fixing 415V, 63A TPN SFU front operated switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (Make L&T/ABB/Siemens)
Supplying & laying of 1.1 KV. Gr. armored XLPE Al. LT cable of following rating on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting for connection from meter loop to LT main panel, from LT panel to VTPN as reqd. complete with necessary gland and terminator as per GS.(Make Polycab/Gloster/KEI) i) 4core X 95 sq.mm.
ii) 4 core X 25 sq. mm.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables. [F4/7©] i) 4core X 95 sq.mm.
ii) 4 core X 25 sq. mm.
iii) 4 core x10 sq. mm
Finishing of the XLPE/PVC insulated armoured cable ends by crimping method with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. [F-5/8.(b)] i) 4 core X 95 sqmm
ii) 4 core X 25 sqmm
Supplying & laying of 1.1 KV. Gr. armored PVC Ar 4 Core x 10 Sq. MM CU cable of following rating on wall/surface including S & F MS saddel (Make - Finolex / Havells / RR Cable )
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9] i) 10 sq mm
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required [E-14/ 1(a)] i) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
ii) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9] i) 4 sq mm
ii) 6 sq mm
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. i) With 25x25x3mm angle iron suppor of following size: 200x50x1.25mm (18SWG)
Supply & Fixing 240 V, 25 A, OLP starter (Brand approved by EIC) with 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), with plug top with 2 Module GI Modular type board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Delivery of Microprocessor based air cooled 1.5TR Concealed type Split Air Conditioner having nominal cooling capacity of 18000 BTU/hr. at ISI condition suitable for operation on 20V, + 5% - 50 Hz. - 1Ph AC supply. Each unit consist of 1No. Rotary compressor & 1 No. IDU with R-410A / R-32 Refrigerant (Make: Hitachi/Daikin/Voltas/Blue star)
Supply, installation & commissioning Copper Refrigeration pipe line for Suction(5/8"OD HD mini. 1.15 mm thick) line with 9mm thick Nitrile Rubber Insulation, supports & brackets.
Supply, installation & commissioning Copper Refrigeration pipe line for liquid (1/4"OD SD mini. 1.15 mm thick) line with 9mm thick nitrile rubber insulation supports & brackets.
Supply, installation & commissioning PVC Drain pipe line (25mm OD HD 1mm thick) with insulation & supports & brackets.
S&L for Ductable AC units of 1.1 KV Grade 4 Core 2.5 Sq.mm IDU to ODU Power Cable (Make:- Glostar/Havells/Polycab/Finolex/Reputed-ISI marked) per direction.
Installation & Commissioning Charges for Ductable Split Air Conditioner (Both Indoor & outdoor unit) with Nitrogen flashing, Pressure testing including fixing copper pipes arrangement for IDU to ODU.
Supplying, fabrication & fixing of M.S. structure with U-channel of 6mm thick of size (75mm x 40mm x 40mm) for making platform for the insulation of outdoor unit of Ductable type AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1.1 1/2 3) etc fabricated with horizontalangle 25mm x 25mm x6mm including supporting angle 50mm x 50mm x 6mm in outer edge for transmitting the load centrally through 2 nos (50mm x 50mm x6mm) Angle inserted into the existing wall including gurding arrangement of 3 side (3' height from platfrom) for maintenance purpose as well as safety. Also making & fabricating Window Frame with opening arrangements along with lock & key.
Supply & errection of special type pilfer proof pannel net guard of giving deep fabrication to suitable M.S. angle, flats and the section 1.2'' x 1.2" 12 SWG welded mech I.R.C. netting suitable for fixing on wall covering the existing pannel board. Should be sterdely and electrically welded in a measurement of front side of the board should be covered by 2 Nos. door palla made of 25mmx5mm flat (column &vertical) and panel guard structure should be made of 50x50x6mm angle left & right side of the panel will be covered 1.2"x1.2" 12SWG I.R.C Net & also raised on same combination be covered by 12SWG I.R.C net with help of reqd. angle & flat to cover up fabrication will be compiete in a compact position finally the protection should be painted with moisture proof red oxide primer & approved paint).
Charges for Civil Work like Wall cutting & finishing and scafolding as per direction of EIC,
SITC of 15 KVA UPS 3 phase input & 1 phase out put on line UPS systems (Make- APC/ Numeric/ AVO) Topology, IGBT BASED DSP CONTROLED Rating of UPS(KVA/KW): 15 KVA / 13.5 KW Input Voltage: 415 VAC Input Frequency: 45 Hz-- 50 Hz Isolation Transformer: Inbuilt Isolation Transformer with 1:1 ratio at UPS Input to be provided at output Back feed Protection: UPS should have back feed protection Charging: Autometic float cum Boots Charging Capability with setteble flote & boost charging voltages and current levels and boots charger timer Output Voltage: 230V Output Voltage Regulation: Static Variation +/_ 1% and Dynamic variation +/-3%
Output Frequency: 50 Hz +/- 0.1% Output Power Factor: 0.9 Crest Factor: 3:1 THDu: < 1% (linear load), < 5%(non linear load) Waveform: Pure Sine Wave Birdge: Microprocessor based and IGBT Technology Overload: 110% for 60 minutes, 125% for 10 minutes, 150% for 30 sec Static By Pass: 100 % rated static switches with fuse protection overload on Bypass: 100% for 10 ms Overall Efficiency: 92% Battary Rack: With power coated MS angle with suiteble dimention and gadge.Useing Nyvin cable with proper rating for interlink cables and battery input and necessary acessiress.
Battery : 12 V, Mono Block batteries. SMF VRLA DC Bus : Minimum 384V or above, 30 mim back up required (Minimum 16128 VAH) Battery. Battery Make: Exide/Amar Raja(Quanta) Protection: Overload, Battery Under Voltage, Fan Failures ,Short Circuit. Four Circuit Breakers, Providing Full Protection When Fault, Strong Overload Capability. Surge Protector at Panel Input & EB Input. PV Reverse Polarity, Input Low & High Voltage, Output Low & High Voltage cut off. Glass cartridge Fuse on Control Circuits MCB at Input Panel, Audio Alarm, Mains Fail, Battery Low Pre-alarm, Inverter Trip Metering: Graphical LCD display for Input & Output - Voltage, Current & Frequency, Battery - Voltage & Current
Indications: Mains - On / Fail / High / Low / Single Phasing DC - On / High, Battery - Low Pre-alarm / Low Trip Inverter - On / Trip / High / Low / Over Current Switchgear: MCB / MCCB for Input, Battery, Output & Manual Bypass Switch Termination: Input, Battery, Output & Bypass Enclosure: IP 20 Operating Temp: 0 to 40 Deg C Humidity: Upto 95% Rh (non-condensing) Cooling: Forced Air Noise: < 55 dB Cold Start : Provided CE Certification:IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950 (Safety) IEC/EN 50091-2, IEC/EN 62040-2(EMC Emmission),IEC/EN 62040-3(performance & Design)IEC/EN 61000-4(EMC Emmunity) & IEC/EN 60146 (Design & Manufacture)
ISO 9001: 2015, ISO 14001: 2015, ISO 45001:2018,ISO 50001;2018 , ROHS Warranty:One Year on UPS & two yers on batteries on site against any Manufacturing defects
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
C. CHOWDHURY AND CO
SILICON SOFTWARE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .