Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹5.5 L+₹92,452 (20.2%)Admitted-Finance 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | L2 | Admitted-Finance | |
| 3 | L3₹8.7 L+₹4.1 L (90.6%)Admitted-Finance 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Bharat Trading Corporation L3 | M/s Abhinav Enterprises L1 | Hi-tech power transmission L2 |
|---|---|---|---|---|---|---|
| 1.00SUPPLY | ||||||
| 1.01 | MS Flat 50×6 mm. | 100 | RMT | 500 ₹50,000 | 195 ₹19,500 Lowest | 250 ₹25,000 |
| 1.02 | MS Flat 25×6 mm. | 100 | RMT | 300 ₹30,000 | 95 ₹9,500 Lowest | 150 ₹15,000 |
| 1.03 | PG Clamp Moose/Panther | 6 | Nos | 1,000 ₹6,000 | 480 ₹2,880 Lowest | 1,200 ₹7,200 |
| 1.04 | PG Clamp Panther/Panther | 21 | Nos | 600 ₹12,600 | 370 ₹7,770 Lowest | 550 ₹11,550 |
| 1.05 | Single tension fitting for panther conductor | 6 | Nos | 3,000 ₹18,000 | 560 ₹3,360 Lowest | 1,850 ₹11,100 |
| 2.00Erection of 33 KV 2×5 MVAR Capacitor Bank and Associated Bay | ||||||
| 2.01 | Main & Auxilary Structure | 5 | MT | 10,000 ₹50,000 | 2,480 ₹12,400 Lowest | 3,500 ₹17,500 |
| 3.00 | Stringing of each phase of 33 KV Bus bar (1 x Panther Conductor) for 33KV Capacitor Bank Bus Bar of each span 6/12mtr, including tension fitting & suspension clamps, hoisting of insulators, cutting of conductor etc. performing all other associated work to complete the job satisfactorily. | 3 | Job | 10,000 ₹30,000 | 1,780 ₹5,340 Lowest | 4,000 ₹12,000 |
| 3.01 | 33 KV Capacitor cells & associated works | 48 | No | 500 ₹24,000 | 370 ₹17,760 Lowest | 520 ₹24,960 |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
25 Feb 2026, 6:00 pmClosed
SE ETC Shahjahanpur
Electy Trans Circle Shahjahanpur
Work
2026_UPTCL_1113517_1
74 ETC(S)/2025-26
Open Tender
Electrical Works
Fixed-rate
60 days
Shahjahanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A/c No. 0423002100107147 IFSC Code No. PUNB0042300
₹7,000
18 Jun 2026
7 Feb 2026
26 Feb 2026
7 Feb 2026
25 Feb 2026
7 Feb 2026
7 Feb 2026 - 25 Feb 2026
SUPPLY
MS Flat 50×6 mm.
MS Flat 25×6 mm.
PG Clamp Moose/Panther
PG Clamp Panther/Panther
Single tension fitting for panther conductor
Erection of 33 KV 2×5 MVAR Capacitor Bank and Associated Bay
Main & Auxilary Structure
Stringing of each phase of 33 KV Bus bar (1 x Panther Conductor) for 33KV Capacitor Bank Bus Bar of each span 6/12mtr, including tension fitting & suspension clamps, hoisting of insulators, cutting of conductor etc. performing all other associated work to complete the job satisfactorily.
33 KV Capacitor cells & associated works
33 KV VCB
33 KV Bus Isolator
CT Junction Box
36 KV NCT
Series Reactor
36 KV 3 Phase PT
Jumpering of equipments
Laying of 1.1 KV Unarmored copper control cable from various 33KV Capacitor Bank equipments to Capacitor Bank C&R Panel.
2C×2.5 sqmm.
4C×2.5 sqmm.
6C×2.5 sqmm.
33KV Capacitor bank bay control cable terminations on CT, CB, PT and control & Relay panel if required etc. as per drawing including cost of cable glands, lugs and ferrules except control cable complete as per drawing & site requirement.
Earthing by Cutting, Straightening & Laying 500 mm below Inside Ground & above Ground of Following sizes for Diagonal / Double Earthing of the Main & Aux. Structures, Equipments and Cable Trenches including Welding with Main Earth Mat and with the Object to be Earthed including Excavation of Trenches & its Back Filling etc. as per Details below :
Earthing of Main Structure with 50 × 6 mm size M.S. Flat
Aux. Structures and Equipments (CBs, Isolators, CTs, PTs, C&R Panel, DPP, Junction Boxes etc. with 50 × 6 mm size M.S. Flat
Painting of M.S flat size 50x6 sq. Mm. After using red oxide primer and painting with green color ISI marked paint two coats on both sides.
Capacity Up-Graduation/ Strengthening of 132 KV Main Bus Bar of Single SINGLE MOOSE Conductors to Twin ACSR moose Conductors alongwith other associated works at 132/33 KV Sub Station Powayan, with all cost of Men, Misc. Consumbles, T&P etc. Required for Satisfactory Completion of the Work, as Per Technical Specefications and Direction of the Supervising Engineer as per Site Requirement as Per Details below:
Supply of 05 No. U-Bolted type single Tension Fitting Assembly with Turn Buckle, suitable for Twin/ Bundle ACSR moose conductors with Complete Hardware fittings, D-Shackle, Socket Eye, Ball Link, Yoke Plate, Tension Clamp etc. as Per Per Sample.
Supply of 02 No. U-Bolted Type Single Suspension Fitting Assembly, suitable for Twin/ Bundle ACSR moose conductors with Complete Hardware Fittings, Socket Eye, Ball Hook, Yoke Plate, J-Hook etc. as Per Sample.
Supply of Spacer, Suitable for 132 KV Bus Bars of Twin/Bundle ACSR moose conductors with 250 mm. Spacing and dully made of LM-6 Alluminium Alloy, Complete with 12 mm. dia. HDG Bolts, Nuts, Spring & Plain Washers, as Per Sample.
Supply of PG Clamp dully Made of LM-6 Alluminium Alloy, suitable for ACSR Moose/Moose Conductor, Complete with 04 No. 16X90 mm. size HDG Bolts, Nuts, Spring & Plain Washers as Per Sample.
Supply of 132 KV Isolators Bi-Metallic Terminal Connector Dully made of LM-6 Alluminium Alloy, Suitable for 132 KV Isolators & Twin ACSR moose Conductor, Complete with 04 No. 12 mm. size GI Bolts, Nuts, Spring & Plain Washers as Per Sample.
Supply of 132 KV PT Bi-metallic Terminal Connector Dully made of LM-6 Alluminium Alloy, Suitable for 132 KV PT & Single moose Conductor, Complete with 04 No. 12 mm. size GI Bolts, Nuts & Spring/Plain Washer, as Per Sample.
Cutting, Straightening, Laying 700 mm. below inside Ground & above Ground of 50 mm. X 06 mm. size MS Flats to be Provided by Department as Per Requirement for Earthing of above Aux. Structures & Bus Isolators including Welding with main Earthmate and with the Object to be Earthed, Excavation of Trenches. its Back Filling Painting of Earthmate above ground Level in Bus Green Colour.
Opening of existing of jumpers of ACSR Panther/ ACSR Moose Conductors between old 132 KV Main Bus Bar to 132 KV Main Bus Isolators; Between 132 KV Main Bus to 132 KV PTs. (01 Job for each Jumeprs)
De-Stringing & Dismantling of existing 132 KV Main Bus Bar of single Moose Conductors Including De-hoisting of Disc Insulator Tension String with Tension Fitting and Disc Insulator Suspension String with suspension Fitting From gantry alongwith Shifting of the Old Conductors, Tension/ Suspension Fitting etc. from Switchyard to Stores at the SubStations. (01 Job. for each Phase of each Section of the Main Bus Bar)
Laying & Re-Stringig of existing 132 KV Main Bus Bar of Twin ACSR moose Conductors Including hoisting of Disc Insulator Tension Strings & Tension Fitting etc. Alongwith Shifting of the Conductors/ Materials from Stores at the SubStations to Switchyard. (01 Job. for each Phase of each Section of the Bus Bar)
Jumpering with Single/ Twin ACSR Moose Conductors between newly Laid 132 KV Main Bus Bars of Twin ACSR moose Conductors to 132 KV Main Bus Isolators & between 132 KV Main Bus Bar to 132 KV Bus PTs. (01 Job for each jumpers)
Erection of lattice type Auxiliary structure ( 2 set BCT) for 132 kV Main bus PT
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.16 MB
BOQ_2061577.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .