Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance NEAR JK BANK KUPWARA BY PASS IMTIYAZ MALIK USMANABAD KUPWARA KUPWARA JAMMU AND KASHMIR 193222 | KUPWARA | JAMMU AND KASHMIR | 193222 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹13.3 L
Closing Date
27 Dec 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RNB Electric Division Sgr
Barbarshah Maisuma Sgr
Internal Electrification with controlling and protection switcher Gear devices for 100 Bed Girls Hostel at Kakroosa Kupwara.
2021_PWDJK_154170_1
E/NIT/221/2021/22dtd 20/12/2021
Open Tender
Electrical Works
Item Rate
30 days
Internal Electrification with controlling and prot
as per BOQ
7 documents required · 7 mandatory
₹600
Executive Engineer RNB Electric Division Sgr
Exempted
27 Dec 2021
20 Dec 2021
27 Dec 2021
20 Dec 2021
27 Dec 2021
20 Dec 2021
120 days
Amount
Wiring for Light Point with 1.5 sq mm PVC Insulated multi strand copper conductor single core cable of ISI Marked in surface / recessed medium class PVC conduit, with 6 Amp One way Switch Isi Marked fitted on Hylam plate with wooden boxes recessed in walls with refacing of walls.The job includes circuit wiring from DB to first switch in sub circuit ( Excl Cost of Conduit )approved before installation)
Wiring for 16 Amp Power Sockets 3x4.0 sq mm ( P+N+E) PVC Insulated multi strand copper conductor single core cable of ISI Mark in surface / recessed medium class PVC conduit, with 16 Amp switch and socket of isi Mark fitted on Hylam plate with wooden boxes recessed in walls with refacing of walls. ( Excl Cost of Conduit) Average legth of circuit upto 8 Mts long. and max 2 points to be wired in one circuit )approved before installation)
Wiring For 6 Amp Light Power Socket Points Plug with 3x2.5 sq mm (P+N+E) PVC insulated multi strand copper conductor single core of ISI Mark in surface / recessed conduit medium class PVC conduit ( Excl cost of Conduit ) with 1x2.5 sq mm sq mm FRLS PVC insulated multi strand copper conductor with 3 no 6 Amp 5 pin socket and 3- No Piano type 6 Amps switch of ISI Mark fitted on Hylam sheet with wooden frame recessed in walls complete with refacing of walls, ( excluding cost of conduit ) Average legth of circuit upto 8 Mts long. and max 2 points to be wired in one circuit )( to be approved before inistallation )
Supply and laying of PVC medium grade Conduit/ channel to be laid on surface with screws fixed in rowel plugs complete with all allied accrues like bends, tees etc.approved before installation)
25 / 31 mm dia
Supply. Installation, testing and commissioning of 1200 mm sweep heavy duty Ceiling fans of ISI Mark (to be got approved before installation) complete with ceiling rose and connection wire.
Supply and fixing of 350 watts Electronic Fan dimmer of ISI Mark
Supply. Installation, testing and commissioning of 250 mm sq Shutter Type Exhaust fans of ISI Mark approved before installation)
Providing ,Installation ,Testing and Commissioning of 15 Watt LED round surface mounted light fixture having aluminium body of ISI Mark .The job includes replacement warrenty of lighting fixuture for a period of three years (incase any fixture is damaged what so ever reason) reckoned from date of sucessful commissioning approved before installation)
Providing and fixing of AC/DC bell of ISI Mark complete with batteries.approved before installation)
Providing, and laying through conduits & testing of wiring for telephone sockets in 2-pair telephone wire of ISI Mark , laid through PVC conduits excl. cost of conduits.
Supply , Laying and connecting of 10 sq. mm PVC Insulated Multi Stand copper wire of ISI Mark laid through conduit excluding cost of conduit for heating sub-main.approved before installation)
Supply , Laying and connecting of 6 sq. mm PVC Insulated Multi Stand copper wire of ISI Mark laid through conduit excluding cost of conduit for lighting sub-main and earth sub-main.approved before installation)
Supply , Laying and connecting of 4 sq. mm PVC Insulated Multi Stand copper wire of ISI Mark laid through conduit excluding cost of conduit for circuit wire for heating.approved before installation)
supply/ installation/testing and commissioning of (Floor Panel)floor mounted compartmentalized , 415 volts TPN MCCB Main Distribution Panel power coated sheet steel of 16 gauge of adequate size to accommodate following accessories having dust protected, vermin proof incl of , , earth terminal with all necessary accessories as required Incomer 250 Amp TPN MCCB of ISI Mark with breaking capacity of 35 KA = 1 no 400 Amp TPN Bus-bar = 1 no 100 Amps F.Pole Change over Switch of ISI Mark 200 Amps TPN Bus Bar Aluminium = 1 Set Volt meter =1 no Ammeter = 1no CT coils for Am meter 300 /5A = 1 set Outgoing 63 Amps DP MCB of ISI Mark = 8 No 40 Amps DP MCB of ISI Mark = 8 No 32 Amps DP MCB of ISI Mark for inverter Sub-Main = 8 No ( approved before installation)
Supply,Laying,Testing & Commissioning of 95 sq.mm 3 1/2 core Steel armored Al Cable XLPE/ PVC Insulated and Steel sheathed, as floor main for heating.approved before installation)
Earthing with Copper plate 600 mm x 600 mm x6 mm thick including accessories, and providing of watering pipe 8 feet long 40 mm dia etc with charcoal/ Coke and salt as required. The Job further includes extension of earthing from earth electrode to controlling panel in one run by using 19 mm copper strip.
Supplying and fixing of following way prewired MCB distribution Boards of sheet steel of ISI Mark Double door recess complete with refacing of walls.approved before installation)
Supplying and fixing of 6-10-16 -20- Amps S Pole rating 240/415 volts MCB of ISI Mark complete with connections.approved before installation)
Supplying and fixing of 63 Amps rating DP 240/415 volts of ISI Mark complete with connections.approved before installation)
Supplying and fixing of 32 -40 Amps rating DP 240/415 volts of ISI Mark complete with connections.approved before installation)
Supply, installation, testing ad commissioning of 50 Watts LED Street light fitting with bracket arm of ISI Mark approved before installation)
Supply,Installation,Testing and Commissioning of 10 KVA Single Phase Relay type Voltage Stabilizer of ISI Mark ,With input voltage of 90-220 Vots & Ouput voltage of 220 Volts ± 5% complete with 0ne yaer warranty against any manufacturer defects approved before installation)
M/S AFAQ AND CO
M/S MOHD ASHRAF MIR
M/S NASEER AHMAD PEERZADA
M/S ROHAN CONSTRUCTION AND CO
M/S A-H-C-C
M/S MODERN ELECTRICALS AND SUPPLIERS
stage.html
html • 0.03 MB
finance_343247.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .