Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹44.8 L+₹90,245 (2.05%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance BEING L2 NOT ADMITTED | |
| 3 | L3₹45.9 L+₹2.0 L (4.56%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance BEING L3 NOT ADMITTED | |
| 4 | L4₹46.4 L+₹2.5 L (5.60%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L4 | Rejected-Finance BEING L4 NOT ADMITTED | |
| 5 | L5₹47.3 L+₹3.4 L (7.76%)Rejected-Finance PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | L5 | Rejected-Finance BEING L5 NOT5ADMITTED |
Tender Value
₹49.8 L
EMD Value
₹1 L
Closing Date
16 Jan 2024, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
MAINTENANCE OF SUMMER APPLIANCE INCLUDING REPLACEMENT OF DEFECTIVE SPARES AND ALLIED WORKS OF SUMMER APPLIANCE AND REPAIR/REPLACEMENT OF INTERNAL WIRING INCLUDING FITTING/FIXTURE WITH CONNECTED ACCESSORIES OF LIFTS MACHINE ROOM AND AC INSTALLATIONS A
2023_MES_633212_1
8787/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW KARANJA
D and above b i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹1 L
Yes
16 Feb 2024
18 Dec 2023
18 Jan 2024
18 Dec 2023
16 Jan 2024
2 Jan 2024
Amount
Notes : (i) The work consists of 02 jobs as under:- JOB (A) : TPP 23-24 Ser No. 75 & JOB (B) : TPP 23-24 Ser No. 96 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A'
Servicing / Preventive maintenance of the following equipments of different capacities by carrying out regular maintenance such as checking of cooling coils, condensers, electric motors of different types and compressors and other parts, cleaning washing with suitable cleaning agent/chemical using vacuum cleaner,Jet spray servicing, replacement of rubber wheels, bolts & nuts, screws check nuts, PVC sleeves and thimbles, and other parts as required, checking all electrical parts and electrical wiring etc, tightening of electrical connections, greasing of electric motors, checking of gas pressure and gas charging to the desired pressure to ensure serviceability regularily through out the contract period all as specified and as directed.
1.5/2.0 Ton capacity window type AC
1.5/2.0/3.0 tons capacity split type AC
Water cooler of any capacity
Refrigerator capacity 165 to 310 Ltr
Dehumidifier upto 2500 Cubic feet
Taking out sealed/ old burnt compressor of window type AC 1.5/2 ton of approved make and S&F new sealed compressor as per reciprocating type suitable for 1.5/2 Ton capacity AC and connecting up suction and discharging pipe line with gas welding complete all as specified and directed
All as BOQ serial item No 1.07 above but split type AC 1.5 Ton capacity complete all as specified and as directed
All as BOQ serial item No 1.07 but split type AC 2 Ton capacity complete all as specified and as directed.
Taking down split type AC and taking out rotary type sealed compressor of split type AC 1.5 ton capacity of approved make and S&F new sealed rotary type compressor suitable and discharging pipe line with gas welding and refixing the repaired AC in its original position complete all as specified and directed.
All as BOQ serial item No 1.10 above but split AC 2.0 ton capacity complete all as specified and as directed.
S&F in replacement copper cooling coil assembly for 1.5 ton air conditioner of approved make including testing and commissioning complete all as specified & directed.
S&F in replacement of copper cooling coil assembly for 2.0 ton air conditioner of approved Make including testing & commissioning complete all as specified and as directed.
S&F in replacement condenser coil assembly suitable for 1.5 ton air conditioner including testing and commissioning complete all as specified and as directed.
S&F in replacement condenser coil assembly suitable for 2.0 ton air conditioner including testing and commissioning complete all as specified and directed. NOTE FOR ITEM NOS 1.01 to 1.15 :- (a) Contractor will provide Guarantee for one year for replaced compressor unit. Compressor should be sealed with original manufacturers packing having reputed make all as specifed & directed approved by GE. (b) Gas charging will be measured and paid separately under relevant items as described.
S&F in replacement running capacitor 36 mfd, 3 pole & 2 pole suitable for 1.5 ton window / split type air conditioner complete all as specified and as directed.
S&F in replacement running capacitor 45 mfd, 3 pole & 2 pole suitable for 2.0 ton window / split type air conditioner. complete all as specified and as directed.
S&F in replacement starting capacitor 100 to 120 mfd suitable for 1.5 ton window / split type air conditioner complete all as specified and as directed.
S&F in replacement starting capacitor 100 to 150 mfd suitable for 2.0 ton capacity window / split type air conditioners complete all as specified and as directed.
S&F in replacement starting relay suitable for 1.5 Ton / 2.0 Ton / 3.0 Ton of Split / Window type AC complete all as specified and as directed.
S&F in repairs of thermostat switch for window / Split type Air conditioner of 1.5 / 2.0 / 3.0 Ton capacity all as specified and as directed.
M&L for gas charging R-22 in window type AC 1.5 ton capacity of approved make and type including pressure testing, leakage, vaccumising, rectification, testing and commissioning complete all as specified and as directed.
All as per BOQ serial item No 1.22 above but 2.0 ton capacity complete all as specified and as directed.
All as per BOQ serial item No 1.22 above but split type AC 1.5 / 2.0 / 3.0 ton capacity complete all as specified and as directed.
M&L for gas charging R-32 in window type split type AC 1.5 / 2.0 / 3.0 ton capacity of approved make and type including pressure testing, leakage, vaccumising, rectification, testing and commissioning complete all as specified and as directed.
S&F in replacement electric wiring kit (PCB) suitable for 1.5 ton / 2.0 ton Split type air conditioner invertor type AC (indoor unit and outdoor unit) complete set of any make and type complete all as specified and as directed. Note: New PCB shall be as per the existing one.
Taking down window type / split type air conditioner of any type / make / capacity from site (either in ground / any floor), transporting to work site opening top and side cover,Jet spray servicing dismantling all electrical controls and components and cleaning the whole unit with electric blower and spray cleaning with water, descaling with acid in both side of cooling coil and components, refixing the covers and making electrical connections, installation of the machine in same location, testing, commissioning complete all as specified and as as directed.
M&L for shifting of Split type Air Conditioner of any type and make, up to 2 TR from existing location to other location and installing indoor and outdoor units as directed including provision of necessary brackets (L type) clamps, GI nuts, bolts and washers etc for fixing of indoor / outdoor units including topping up of refrigerant gas and Nitrogen pressure test to find out leakage, commissioning and testing and making good disturbed surface complete all as specified & directed. Note : PVC pipe for protection , drain pipe , control cable, extra copper tubing of any size for suction / discharge will be measured and paid separately.
M&L for shifting of Window type Air Conditioner of any type and make, up to 2 TR from existing location to other location and installing as directed, commissioning and testing including making opening of required size in walls or existing windows of any type, provision of necessary brackets, clamps, GI nuts, bolts and washers etc for fixing of AC,and making good disturbed surface of walls and windows complete all as specified & directed. Note : PVC drain pipe , control cable where required will be measured and paid separately.
S & F in replacement electric wiring kit (PCB) suitable for 1.5 ton / 2.0 ton Window type / Split type air conditioner of any make and type complete all as specified and as directed. Note: New PCB shall be as per the existing one.
Supply only in replacement Remote assembly cordless as per existing make and size window/split type AC's as per AC make complete all as specified & directed.
Taking down corroded body base tray etc of Window / Split type AC of 1.5 Ton / 2 Ton capacity and replacement of body base tray etc made out of 18 SWG mild steel and other portion of mild steel sheet of 20 SWG including motor mounting frame fix with nuts and bolts of suitable size and painting with one coat of black enamel paint and necessary insulation complete all as specified and as directed. Note :- Unit rate quoted shall also deemed to include for reassembling.
S&F in replacement of fan blade of motor for window type AC of capacity 1.0 ton / 1.5 ton / 2.0 ton complete all as specified and as directed.
S&F in replacement blower fan motor for 1.0 ton / 1.5 ton / 2.0 ton split AC capacity air conditioners including testing, complete all as specified and as directed. (Make: Blower fan motor shall be as per the existing one)
S&F in replacement blower drum suitable for window type AC of capacity 1.0 ton / 1.5 ton / 2.0 ton completeall as specified and as directed. (Note: Blower drum shall be as per the existing one).
S&F in replacement front cover grill suitable for window type air conditioner of capacity 1.0 ton / 1.5 ton / 2.0 ton, complete all as specified and as directed
S&F in replacement outer cover suitable for window type air conditioner of any capacity complete all as specified and as directed.
S&F in replacement blower motor capacitor 4 mfd suitable for 1.5 window type air conditioner complete all as specified and as directed.
S&F in replacement blower motor capacitor 10 mfd suitable for 1.5 ton split type air conditioner complete all as specified and as directed.
S&F in replacement blower motor capacitor 15 mfd suitable for 2.0 / 3.0 ton split type air conditioner complete all as specified and as directed.
S&F in replacement copper suction pipe line of size 1/2" dia and other all as per manufacturers recommendation complete with cutting, brazing work and insulation including fittings required at site complete all as specified and directed
S&F in replacement copper discharge pipe line of size 1/4" dia and other all as per manufacturers recommendation complete with cutting, brazing work and insulation including fittings required at site complete all as specified and directed
S&F in replacement cable PVC insulated PVC unsheathed, multistranded, 1100 volts grade (ISI marked) 3 core 2.5 Sq mm with flexible copper conductor suitable for Split type AC and Window type AC complete all as specified and as directed.
S&F in replacement suitable size PVC pipe, heavy duty for drain out of condensing water of split type air conditioner including cutting of floors or making hole in wall and making good the disturbed portion after laying pipe etc to match the existing surface with original specifications complete all as specified and as directed.
S&F in replacement synthetic air filter suitable for split/window type air conditioner any capacity complete all as specified and as directed
M&L for Flushing out the nitrogen gas from condensing coil of AC 1.5 Ton capacity (Window/split) complete and repairs of leaking place by gas welding complete and recharging of refrigerant (R-22 & R-32) complete all as specified & directed (Refrigerant shall be measured and paid seperately.
M&L for Flushing out the nitrogen gas from condensing coil AC 2 Ton (window/split) capacity complete and repairs of leaking place by gas welding complete and recharging of refrigerant (R-22 & R-32) complete all as specified & directed (Refrigerant shall be measured and paid seperately.
S&F ,in repairs, capillary tube for Spilt type AC including brazing and connecting with existing system complete all as specified and directed.
M&L for removing the worn out old painted from surface of split unit external, scraping cleaning the old paint and repainting with proper colour as approved on external surface over a coat of red oxide primer by spraying painting all as specified and directed.
S&F in repairs, wiring kit for Window/split AC of any capacity comprising of copper conductor cables for connections of assembly, complete all as specified and directed.
M&L for dismantling the indoor and outdoor units of Air conditioner Window/Split type completely,transporting to Workshop for carrying out repairs, transporting back to the site,reinstalling the same on the new /existing location complete all for satisfactory functioning of the equipment complete all as specified & directed. (Note1-Spare replaced during the proces of repair shall be measured and paid separately. (2) Rates include the cost of dismantling and transporting the AC to workshop and labour element for carrying out repairs. (3) The decision of Engineer -in -charge shall be final and binding on whether machine is required to be sent to workshop for repair or not.
All as per BOQ serial item No 1.51 above but for water cooler of any capacity.
All as per BOQ serial item No 1.51 above but for refrigerator/deep freezer of any capacity.
S&F in replacement of wall mounting type AC timer having Delay Time Facility, Auto & manual switch ,Suitable for window ,splits type AC of capacity 1.5/2 TR.Operating on AC input Supply: 230VAC +/- 15 %, 50Hz. Output: 230V, 25 Amp. Separate for 2 A/Cs having Protections for Over voltage (OV): Cutoff 270 V & Cut in 260 V Under voltage (UV): Cutoff 160 V & Cut in 170 V working for 24 Hours timer in 4 to 8 hours time intervals complete all as specified and directed.
S&F in replacment of 3 way backlite connector of capacity 20Amps for Acs (Window/Split) complete all as specified and directed.
M&L for Removing old unserviceable 2-3 way refrigerant control valve from split air conditioner outdoor unit after evacuating of refrigrant gas and S&F 2-3 way valve suitable for split type ACs of capacity upto 2 TR and testing complete all as specified and directed.
S&F in replacement insulation (closed cell elastomeric insulation in tubing) over copper tubing wherever required using approved material as per manufacturers recommendation complete all as specified and directed.
S&F in replacement of Indoor cabinet for split type AC of any make and any capacity or as per sample complete all as specified & directed.
M&L for servicing, cleaning of Solar water heater system by dismantling inlet and outlet connection, washing with suitable cleaning agent castic soda, arresting leakage and refixing the same after replacement of bush, nut, bolts,washers, painting of rusted surfaces if any making serviceable to desired satisfaction level complete all as specified & directed.
WATER COOLERS Taking down sealed compressor of water cooler of approved make of capacity 40/80 ltrs and S&F company repaired sealed unit CAJ 3612 or AE 4440 of M/s Kirloskar or equivalent and connecting up suction and discharge copper pipe with gas welding pressure testing of leakage rectification, vaccumising and charging the refrigerant gas including testing & commissioning complete all as specified and as directed.
All as per BOQ serial item No 1.60 above but capacity 60/120 ltrs complete all as specified and as directed.
S&F in replacement starting capacitor 40/60 mfd complete all as specified and as directed.
S&F in replacement starting capacitor 80 /100 mfd complete all as specified and as directed.
S&F in replacement of thermostatic switch for water cooler complete all as specified and as directed.
S&F in replacement of condenser fan motor 1 / 35 HP 230 volt AC single phase suitable for water cooler all as specified and as directed.
All as per BOQ item No 1.65 above but 1 /83 HP complete all as specified and as directed.
S&F in replacement relay for water cooler of capacity 40/80 litres and 60/120 litres capacity all as specified and as directed.
S&F in replacement of fan blade suitable for existing water cooler of any capacity, approved make and type complete all as specified and as directed.
S&F in replacement push cock/lifting cock of 15 mm dia chromium plated suitable for water cooler of capacity 40/80 litres & 60/120 litres complete all as specified and as directed.
M&L for detecting the gas leakage, rectifying the defects, vacumizing and charging fresh refrigerant gas and commissioing and testing the water cooler of capacity upto 60/120 litre capacity , complete all as specified and as directed.
S&F in replacement of water tray stainless steel grade SS 304 of 40 /80 ltr capacity complete all as specified and as directed.
All as per BOQ serial item No 1.71 but capacity 60/120 Ltrs complete all as specified and as directed.
S&F in repairs of rubber packing and hinges of top cover of water cooler of any make and capacity complete all as specified and as directed.
S&F in replacement 15 mm dia float valve Brass complete all as specified and as directed.
S&F in replacement over load protector for water cooler of any capacity complete all as specified and as directed.
S&F in replacement PVC connecting pipe with brass nuts & washers at both ends of length not exceeding 60 cm for water connection of water coolers complete all as specified and as directed.
S&F in replacement suitable size PVC drain pipe flexible heavy duty with necessary saddles and fitting for drain out water from water cooler complete all as specified and as directed.
M&L for Flushing out the nitrogen gas from condensing coil Water cooler of capacity 150/150, 120/60 and 80/40 ltrs complete and repairs of leaking place by gas welding complete and recharging of refrigerant all as directed (Refrigerant shall be measured and paid seperately.
REFRIGERATORS Taking down sealed compressor of 165 Ltr/175 ltrs capacity of refrigerator of approved make and type and replacement of hermetically sealed unit of compressor of same size and type and capacity , connecting sealed unit and discharge pipe with gas welding and soldering rod complete all specified and as directed.
All as per BOQ serial item No 1.79 above but 286/300/310 ltr capacity complete all specified and as directed.
S&F in replacement thermostat switch for refrigerator of any capacity, complete all as specified and as directed.
S&F in replacement over load relay/protector suitable for high / low speed refrigerators of unit of compressor 165 /230 /286 /300 / 310 Ltr capacity of refrigerator complete all as specified and directed.
S&F in replacement lamp 15 watt or any watt screw /pin type suitable for approved make and capacity refrigerator complete all as specified and directed
M&L for charging of refrigerator refrigerant gas R-134a/ R-410a suitable gas after vaccumising / pressure and leaking including flushing the system in the refrigerator of any make of 165 Litre Cap complete all as specified and directed
All as per BOQ serial per item No 1.84 above but 230 / 286 / 300 /310 Ltr capacity complete all specified and as directed.
S&F in repairs magnetic gasket for refrigerator of 165/175/286 /300 /310 litres capacity all as specified and as directed.
S&F in replacement relay for refrigerator of capacity 165 to 310 litres complete all as specified and as directed.
S&F in replacement of unservicable freezer chamber existing make & size for upto 165 to 195 Ltr capacity refrigerator direct cool complete all as specified & directed.
S&F in replacement of unservicable freezer chamber existing make & size for refrigerator frost free double door including heater, blower etc for 285 to 310 litres capacity complete all as specified & directed.
S&F in replacement condenser for refrigerator as per existing make & any capacity, complete all as specified and directed.
S&F in replacement of filter dyer for refrigerator of capacity 165/180/190/280 to 310/320 Ltrs complete all as specified and directed.
Defumidifier Taking down defective/unserviceable dehumidifier of existing capacity and existing make, transporting to maintenance yard, collecting repaired dehumidifier of same make and transporting back to site, refixing at original position complete including testing and commissioning the machine complete all as specified and directed.
M&L for replacement of water purifier filter kit including repair/ replacement of defective parts such as filters, solenoide valve, pump, switch complete all as specifed & directed.
M&L for repair of voltage stabilizer of capacity 5 KVA including replacement of burnt out transformer and all accessories complete all as specified & directed.
S&F in replacement wall mounted type sheet metal single pole and neutral enclosure with a two pin and earth plug and socket complete with and including one No MCB SPN 20 Amp 'C' series 10 KA mounted on DIN rail channel and suitable plug complete all as specified and directed. (Note : Item rate including all items ie base box, plug, socket , MCB complete)
S&F for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sqmm (nominal area) drawing in and including 20 mm dia or higher medium duty PVC concealed conduit and conduit accessories and fittings. Including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 4 Sq mm as earth wire upto common earth and connected to earth dolly including taking out old unserviceable submain complete all as specified & directed.
S&F in replacement of contactor relay complete all as specified and directed.
ITEMS FOR JOB 'B'
Taking down and dismantling existing street / post lantern / tube light fittings any type any wattage for repair or replacement of burnt /worn out accessories and refixed in position after repair complete all as specified & directed. Note :- (i) Accessories wherever required shall be measured and paid seperately as supply only. (ii) Labour charges for taking down and repair including minor spares like nuts, bolts , insulation materials & cleaning of area upto one mtr around the street light/ building lights/ Poles shall be deemed to be included in the rate .
S&F LED batten with 20W LED tube light in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten complete all as specified & directed.
S&F Pressure die cast aluminium housing LED street light luminaires with IP66 of 35/45 Watts complete all as specified & directed.
S&F Pressure die cast aluminium housing LED street light luminaires with IP66 of 90 Watts complete all as specified & directed.
S&F Pressure die cast aluminium housing LED street light luminaires with IP66 of 120 Watts complete all as specified & directed.
S&F LED floodlight luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66, Turbo LED series ,120Watt & accessories and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core complete all as specified and directed.
S&F LED drivers suitable for 120w flood light light fitting complete with all accessories complete all as specified and directed.
S&F LED drivers suitable for 90w light light fitting complete with all accessories complete all as specified and directed
S&F in repairs bracket for street light fittings made out of 40 mm bore medium grade GI tubing 1.2 m long bent to shape and including suitable size of MS clamps, nuts, bolts and washers applying two coats of aluminium paint over a coat of red oxide zinc chrome primer repair complete all as specified and directed.
Taking out cable loop after necessary excavation , cutting the burnt out damage end of cable ,refixing the cable providing suitable size of brass cable gland and aluminium lugs complete with all necessary connection with the existing system and refilling of excavated soil making finishing with the existing ground surface for the following sizes:-
4 core 16 Sqmm
3.5 core 25 Sqmm
3 core 35 Sqmm
3 core 50 Sqmm
S&F twin core PVC insulated multistranded 1100 volt grade copper conductor cable of size 2.5 sqmm drawn through existing pipe complete all as specified and directed.
M & L earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point complete all as specified and indicated including testing on completion. Note : (i) The unit rate includes for protection pipe and GI strip from top of earth plate up to 7.5 meter above ground level and also the cost of the Test point. (ii) Joining of GI earth strip with pipe of the test point shall be done by using suitable cable lugs.
S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 12 way double door openable type complete all as specified & directed.
S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 8 way double door openable type complete all as specified & directed.
S&F 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series) complete all as specified & directed..
S&F 6 to 32 AMP MCB SPN 240 V 10 KA (C-Series) complete all as specified & directed..
S&F 40 to 63 AMP MCB SPN 240 V 10 KA (C-Series) complete all as specified & directed..
S&F in repairs power contactor 3 pole, type MNX- 80, with standard coil voltage 240 volts, rating 100 Amp complete all as specified and directed.
S&F in repairs power contactor 3 pole, type MNX-110, with 2 NO + 2 NC aux contacts with standard coil voltage 240 volts, rating 160 Amp complete all as specified and directed.
S&F in repairs power contactor 3 pole, type MNX-140, with 2 NO + 2 NC aux contacts with standard coil voltage 240 volts, rating 160 Amp complete all as specified and directed.
S&F in repairs on-off push button pendants with elements red/green/orange type complete all as specified and directed.
S&F in repairs indication lamp complete all as specified and directed.
S&F in repairs MCB TP, 415 Volts, 50 Hz, 10 KA conforming to IS 8828 of rating 25-63 Amp complete all as specified and directed.
S&F in repairs MCB TPN, 415 Volts, 50 Hz, 10 KA conforming to IS 8828 of rating 16-32 Amp complete all as specified and directed.
S&F in repairs MCCB TP, 415 Volts, 50 Hz, 25 KA conforming to IS 8828 of rating 100 Amp complete all as specified and directed.
S&F in repairs MCCB TP, 415 Volts, 50 Hz, 36 KA conforming to IS 8828 of rating 160 Amp complete all as specified and directed.
S&F in repairs MCCB 3 Pole , 415 Volts, 50 Hz, 36 KA conforming to IS 8828 of rating 250 Amp complete all as specified and directed.
S&F in repairs MCCB 4 Pole , 415 Volts, 50 Hz, 36 KA conforming to IS 8828 of rating 250 Amp complete all as specified and directed.
S&F in repairs MCCB 4 Pole , 415 Volts, 50 Hz, 36 KA conforming to IS 8828 of rating 400 Amp complete all as specified and directed.
S&F single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 2.5 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
S&F single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 4 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
S&F single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 6 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
S&F single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 10 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
S&F single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 16 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
S&F single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 35 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
S&F single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 95 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
S&F single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 120 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
S&F single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 150 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. complete all as specified and directed.
Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, all as specified and directed.
M & L for Point wiring with single core 1100 volts grade 1.5 sqmm size PVC FRLS insulated unsheathed stranded copper conductor cable using color code drawn through PVC existing conceiled conduit with all accessories such as cover plates, metal boxes of adequate size Complete all as specified in and including 1.5Sq mm PVC insulated unsheathed copper conductor cable for continous earth conductor (using green colour)to common earth and connecting to earth dolly for the following :-
One light or fan point controlled by one switch.
One 3 pin socket outlet 5 Amps on independent board
One 3 pin socket outlet 5 Amps on same board
M&L for point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including surface PVC casing caping (ISI marked) and shall be of one of the make M/s Precision/ M/s Asian/M/s Prestoplast/M/s BEC with all accessories including surface/ concealed sheet steel terminal/CI box with 3mm thick hylam/masonite sheet top including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly all as specified & directed.
All as per BOQ serial per item No 2.49 above but one 5 amp socket point on same board
All as per BOQ serial per item No 2.49 above but one 5 amp multi socket indepenedent
S&F switch piano flush button single pole one way, 5 Amp complete all as specified and directed
S&F switch socket 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed.
S&F stepped type electronic fan regulator (5 step) for ceiling fan of suitable size, complete all as specified and directed.
S&F ceiling rose PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals complete all as specified and directed.
Shree Ayyappa Engineering
M.K Enterprises
pk Enterprises
K A ELECTRIC CO
somnath engineering corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .