| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹28.9 L+₹5.1 L (21.6%)Rejected-Finance NEAR DON BOSCO SCHOOL MORE NA ATALIKA APARTMENT SEVOKE ROAD SILIGURI PIN 734001 WB | SILIGURI | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹30.9 L+₹7.1 L (29.8%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹32.5 L+₹8.8 L (36.9%)Rejected-Finance 10 UDAY SHANKAR SARANI SEVOKE ROAD SILIGURI DIST DARJEELING WB PIN 734 001 | JALPAIGURI | WEST BENGAL | 734001 | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹32.9 L+₹9.2 L (38.5%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹35.6 L
EMD Value
₹71,200
Closing Date
7 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BENGDUBI
Bengdubi Military Station, PO-Bengdubi, Dist-Darjeeling, Pin 734424
PROVN OF CHECKERED TILES ON FOOTPATH, SUPER STRUCTURE FOR BURNING PIT, OVERHEAD LEADING, FOOTPATH, GATE, BAGGAGE ROOM, LADIES TOILET, COOK HOUSE SHELTER OF FAD UNDER AGE B/R-I OF GE BENGDUBI MIL STN
2020_MES_367525_1
GE/BENG/21 OF 2020-21
Open Tender
Civil Works
Works
210 days
GE BENGDUBI
MES Enlisted/ Un-enlisted contractor of Class D and above with category a(i)
8 documents required · 8 mandatory
₹500
GE BENGDUBI
₹71,200
Yes
24 Sept 2020
8 Aug 2020
9 Sept 2020
8 Aug 2020
7 Sept 2020
26 Aug 2020
12 Aug 2020 - 14 Aug 2020
60 days
Amount
SCHEDULE 'A' PART-I (B/R WORKS)
Surface dressing n exc 15 cm deep in soft/ loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.5 mtr deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc and getting out in soft/loose soil complete all as specified.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n.exc 50 m and making good surface for soft/loose soil complete all as specified.
Removing excavated material (soil) to a distance exc 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft / loose soil complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling & mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in foundation filling & mass concrete complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on new wood and wood based surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface complete all as specified and directed.
M&Lfor Fly ash brick work with old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on brick or concrete surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for Rendering 15 mm thick on other than fair faces of brick work or concrete surface in cement mortar (1:6) surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar 1:3 on ceiling surface finished even & smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed.
M&L for preparation of new surface of wall and two coat of white wash over a coat of primer on walls complete all as specified and directed.
M&L for preparation of old plastered surface and two coat of white wash on ceiling including a coat of chalk whiting primer complete all as specified and directed.
M&L 75 mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of flooring /bedding of footpath complete all as specified and directed.
M&L 75 mm thick PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in flooring complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 20mm thick in cement mortar (1:6) complete all as specified and directed.
M&L for screed bed or bedding layer over rof slab of mortar 10mm thick in cement mortar (1:4) complete all as specified and directed.
M&L for chequered cement tiles of approved quality size 20cmX20cmX 25mm thick on floors, footpath etc and jointed in neat cement slurry and pointed with colour to match th tiles complete all as specified and directed.
M&L sand filling in layers n exc. 25 cm thick complete all as specified and directed.
M&L for surface painted with one coat bituminous primer @ 0.40 Kg per Sqm confirming to IS158, a layer APP based polymeric membrane minimum weighing 3.5kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. Not less than 150 gms/sqm) laid over a coat of bitumen @ 1.20 kg per sqm on primed surface by torced application side overlaps shall be minimum 75mm and end laps shall be minimum 100mm and sealing all overlaps and joints and manufacturer's instructions and provided upto a height of 60cm in the parapets by cutting a groove and finished by membrane flashing painted with bitumen @1.2 kg per sqm before application of aluminium paint complete all as specified and directed.
M&L one coat of silver paint @ 0.125 kg/sqm over App membrance complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of oil emulsion distemper of approved tint on wall over a coat of wall care putty complete all as specified and directed.
M&L for coloured with grey cement and pigments Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) Providing, precast cement concrete in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts,boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match set in CM 1:6 complete all as specified and directed.
S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410-W (Gde-E-250 quality-A) complete all as specified and directed.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed.
M&L for Firebrick work in linings to fire places, flues, etc. (other than in chimney shafts), set, jointed and pointed in fireclay complete all as specified and directed.
Cutting opening in cement concrete walls (any descript-ion) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc where reinforcement is cut through complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description and in any position complete all as specified and as directed.
S&F roof trusses (farmed), trusses purlins, crane gantries, rails and fastenings and heavy bracket framing MS tubes medium grade as in truss, purlin, rafters, post etc fixed with and including angle cleat , MS plate etc including necessary welding, fittings etc Fe-410-W (Gde-E-250 quality-A) complete all as specified and directed.
S&F Pre-painted coloured trapezoidal profiled galvalume/Zincalume sheet thickness of 0.50 mm TCT confirming to IS-513 (AZ-150 GSM, Al Zn alloy mettalic coating with 550MPA yield stress as per AS-1397) as in roof covering/cladding to wall fixed with self tapping screws(12-14 x 55 with EPDM seals), colour /exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to FE-410W (Gde-E-250) all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W (Gde-E-250 quality-B) complete all as specified and directed.
M&L for hardcore of gauge not exc. 63mm, deposited, spread and levelling in layers not exc. 15 cm thick, watered and rammed to true surface with broken stone or boulder complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in plinth protections 75mm thick finished even and smooth w/o using extra cement with joints 10 mm wide and in full depth at corners and @ 3.0 m c/c filled with mastic mortar complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles all as directed.
M&L for RCC (Design Mix) M-25 using 20 mm graded crushed stone aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC (Design Mix) M-25 using 20 mm graded crushed stone aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L RCC (Design Mix) M-25 using 20 mm graded crushed stone aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L RCC (Design Mix) M-25 using 20 mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L RCC (Design Mix) M-25 using 20 mm graded crushed stone aggregate as in chajjas, shelves complete all as specified and directed.
Use & Waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to chullah hoods, chajjas, troughs and similar items including edges, rough finished surface of concrete complete all as specified and directed.
S&F 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, Cooking Platfarms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for two coats of cement base paint on wall, soffits of chajjas, cornices etc including prepration of plastered/unplastered surfaces complete all as specified and directed.
S&F pressed steel frame door 125 X 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
S&F of 35mm thick flush shutter, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 2nd class HW glazed and skeleton 35mm thick door shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sites of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (b) complete all as specified and directed.
S&F for Steel windows with side hung double shutters(one for glazing and other for mosquite proofing) including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F 100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
S&F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F 125mm mild steel pressed handle oval type stove enamelled black complete all as specified and directed.
S&F 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 3.00 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome complete all as specified and directed.
M&L for vitrified tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.36 sqm, in floors etc. set over 15mm thick screed in cement mortar (1:4) and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
ditto all as per item no 62.00 above but on dado /skirting set jointed in neat cement slurry and pointed with colour cement to match the tiles complete all as specified and directed.
M&L for TMT bars (Fe-500/ Fe-550D) 10 mm dia & over, cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars (Fe-500/ Fe-550D) 8 mm dia, cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per item No. 64.00 here-in-before but 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders complete all as specified and directed.
SCHEDULE 'A' PART-II (E/M WORKS)
M & L for concealed point wiring with FRLS PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface for the following: -
One light point or one fan/light/bell point controlled by one switch
One 3 pin socket outlet, 5 Amp independent
One 3 pin socket outlet, 5 Amp on the same board with other switches
All as per item No 68.00 here-in-before but for one 15 Amp 3 pin switch socket outlet, independent with 2.5 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire complete all as specified and as directed.
S&F Switch piano, flush button type, single pole, one way 5 Amp, 230 volt complete all as specified and directed.
S&F switch socket outlet combination 2 in 1, 5 Amp, flush piano type complete all as specified and as directed.
S&F switch socket outlet combination 5 in 1, 5A/16A Amp, flush piano type complete all as specified and as directed.
S&F ceiling rose surface bakelite three terminals complete all as specified and as directed.
S&F ceiling fan regulator electronic stepping type, SP 230 volts, flush type (2-module) suitable for 1200mm / 1400mm sweep ceiling fan inliding necessary electric connection complete all as specified and directed.
S&F LED Neo tube light fitting 1x 18W, 230 V, with tube 4 feet wall mounted LED batten ultra bright LED polycarbonate tubelight with very high efficency suitedfor installation existing T8 tubelight with G13 lamp holders to give glare free light complete all as specified and as directed. (Make Crompton/ Havells/ Bajjaj/ Philips)
S&F Sheet metal enclosure for MCB, DBs, phosphatised, power coated, double door single pole & Neutral 4 way with common bus bar at incoming end complete all as specified and directed.
S&F Sheet metal enclosure for MCB, DBs, phosphatised, power coated, single door single pole & Neutral 2 way without bus bar at incoming end complete all as specified and directed.
S & F Building security LED light luminaire fitting 1X20 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt, nut,washer,clam made out of MS flat of size 25X3 mm, 4 nos Anchor Bolt of suitable size etc all as specified and as directed. Make : CG MODEL LST 20 CDL/ SURYA MODEL SLE UL 20 W IP66 LXN.
S&F MCB single pole 6 to 32 Amps, breaking capacity 10KA, 240 Volts 'C' curve all as specified and directed.
S&F MCB double pole 6 to 32 Amps, breaking capacity 10KA, 240 Volts 'C' curve all as specified and directed.
M&L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through PVC conduit complete all as specified and directed. Note :- (a) PVC Conduit / casing- caping shall be included in same rate. (b) For concealed sub-main wiring cutting chases shall be included in rate. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
M&L for Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification . GI Electrode Shall be tested from CPRI.The earting pit should be cover with PCC (1:2:4, type B-1) cover ,of 450 x 450 mm complete all as specified and directed. (Make: ASHLOK / INDELEC / JMV / TERCEL).
S&F Exhaust Fan of Size 300mm sweep(metal body), 230Volts AC, with louver shutter including cutting of hole in wall of suitable size and connection from existing ceiling rose to fan complete all as specified and directed.(Make: USHA Model NO. TOUBO DBB-G Gay or equivelent)
Material and labour for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 6 Sqmm 2 core laid in trench /poles/on wall complete all as specified and directed.
Material and labour for sand cushioning for protection of underground cable consolidated and compacted with clean dry sand complete all as specified and directed (Compacted thickness shall only be measured and paid)
Material and labour for well burnt bricks, Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and directed.
Material and labour for galvanized iron tubing 50 mm bore light grade with all fitting for protection of cable, laid in trenches/road crossing incl necessary clamp, bolt/nut if any all as specified and directed. Note: Excavation, earth work shall be measured and paid separately
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 25325.00 (refer Tender Srl Page No 31). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
M/S AHUJA TRADING
NIRMAN INDIA
Paritosh Saha
M/S UTTAM ENTERPRISES
BISWAJIT SAHA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .