Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.3 L+₹2.4 L (11.5%)Rejected-AOC | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹23.9 L+₹2.9 L (13.9%)Rejected-AOC | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹25.7 L+₹4.7 L (22.6%)Rejected-AOC D K CITY C 42 MINNIEBAY POST BOX NO 340 HPO PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-AOC Not L1 | |
| 5 | L5₹25.7 L+₹4.7 L (22.7%)Rejected-AOC | L5 | Rejected-AOC Not L1 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
28 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Brichgunj
GE Brichgunj, port Blair
SPL REP OF BATHROOM BLOCKS IN BLDG NOS. P-18 AND P-29 OF INF BN -I AT BRICHGUNJ MIL STATION, PORT BLAIR
2021_MES_480504_1
GE8163A
Open Tender
Civil Works
Item Rate
180 days
GE Brichgunj
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE Brichgunj
₹48,000
Yes
26 Nov 2021
8 Oct 2021
30 Oct 2021
8 Oct 2021
28 Oct 2021
21 Oct 2021
8 Oct 2021 - 20 Oct 2021
60 days
Amount
Demolition of reinforced roof slabs, beams, staircases, landing, chajja and similar suspended work complete all as specified and as directed by Engineer-in-Charge
Separating, scraping and cleaning of reinforcement Note: Demolition of concrete measured separately.
Disconnecting of existing tank of capacity 1000 ltr and setting aside or lowering if required for repairs cleaning etc and refixing in position hoisting and connecting, complete all as specified and as directed by Engineer -in-Charge.
Material and labour for water proofing treatment with the following specifications including taking down existing roof treatment of any description and cleaning with water and scrubbing and disposing off the rubbish outside the premises, complete all as specified and as per manufacturer’s instructions:- (i) Rendering 10mm thick in CM 1:4 on concrete surfaces mixed with water proofing compound @ 3% by weight of cement as leveling course (ii) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. (iii) Laying APP membrane (STP Aquashield or equivalent) weighing not less than 3.5Kg/sqm, reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. (iv) Apply one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm over the membrane. Note:- Water proofing compound shall be measured and paid separately)
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed
Material and labour for cutting out cracks to V-section in existing roofs or terrace, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and as directed
Material and labour 15mm thick wearproof topping with approved metallic floor hardner of make fosroc or equivalent in sika/STP/bostik as approved by GE, laid on concrete floors and pavings, and finished even and smooth all as specified.
Supply and fix coloured joint free non Skid ceramic tiles 7 to 8mm thick (square) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, in floors etc. set, jointed and pointed in white or coloured cement to match over screed bed in cement mortar 1:4, 15 mm thick, all as specified and directed.
Supply and fix coloured glazed ceramic tiles 450mm x 300mm x 7 to 8mm thick on vertical surfaces such as skirting & dados etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with surfaces etc including backing coat in cement mortar 1:3, 10 mm thick, complete all as specified and directed.
Taking down cement plaster of any description from wall/ceiling including raking out joints hacking for key, scrubbing down with water etc, complete all as specified and directed.
Material and labour rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement.
Material and labour for 15mm thick external rendering in two layers of 5mm thick in CM (1:4) mixed with water proofing compound (water proofing compound shall be @3% weight of cement) over and including a coat of 10mm thick in CM (1:6) over brick or concrete surfaces finished even and fair. Note: Supply only WPC will be measured and paid separately
Supply only Integral water proofing compound
Material and labour for rendering 5 mm thick in CM 1:3 finished even and smooth without using extra cement on ceiling including cement slurry 3 kg/sqm.
Material and labour for two coats of OBD over and including a coat of primer and over a coat of interior grade wall care putty on newly plastered surfaces of walls including necessary preparation of surfaces all as specified and directed.
Material and labour for two coats of weather proof exterior acrylic emulsion paint with anti-fungal property over a coat of primer over a coat of exterior grade wall care putty including preparation of new wall surfaces etc complete all as specified and as directed.
Material and labour for two coats of OBD over and including a coat of primer on newly plastered surfaces of ceiling including necessary preparation of surfaces all as specified and directed.
Material and labour for preparing old decorated surfaces of ceiling by complete removal of existing treatment and applying two coats of OBD over a coat of primer complete all as specified and directed.
Material and labour for two coats of OBD over and including a coat of primer over and including a coat of interior grade wall care putty on old plastered surfaces of walls including necessary preparation of surfaces by complete removal of existing treatment all as specified and directed.
Taking up or down 15mm dia bore steel tubing galvanised and connections complete all as specified and directed.
Taking up or down 20mm dia bore steel tubing galvanised and connections complete all as specified and directed.
Supply and fix 15mm dia bore unplasticised PVC pipes of pressure rating 10kgf/cm with all fittings and fixed complete to walls and ceilings or laid in floor etc complete all as specified and directed.
All as per item No 22 here in before but 25mm
Taking down carefully, copper/aluminium point wiring (Light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, regulators, sockets etc., and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully tube light fitting any type/capacity after removing the electrical connections, keep the serviceable fittings in safe custody for reuse and refixing back the serviceable fitting duly cleaning the fitting and connecting with twin core sheathed cable from fitting to ceiling rose and remove the unserviceable fittings from site complete all as directed.
Material and labour Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for one light/ fan point controlled by one one way switch.
All as per item No 26 here in before One 3 pin switch socket outlet point 5 amps on independent board.
Supply and fix Switch piano, flush type, single pole, ISI marked, one way 5 Amps 240 volts all as specified and as directed
Supply and fix switch socket outlet 3 & 2 pin (multi pin) 5 amps flush/box type, complete all as specified and as directed by Engineer-in-Charge
Material and labour for ceiling rose surface PVC/ Polycarbonate, 3 terminals complete all as specified and directed.
Supply and fixing energy efficient LED batten 22 watt fitting 4ft in length including lamp and connecting with twin core sheathed cable from fitting to ceiling rose all as specified and as directed.
Supply and fixing energy efficient LED batten 10 watt fitting 2ft in length including lamp and connecting with twin core sheathed cable from fitting to ceiling rose all as specified and as directed.
Supply and fix exhaust fan of 200 mm sweep plastic body including louvers and including making circular/ Square opening by cutting wall and connecting with three core sheathed cable from fitting to ceiling rose complete all as specifed and as directed by the Engineer in Charge
Supply, lay, test and commissioning underground XLPE insulated and PVC sheathed, armoured heavy duty underground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 2 Core 10sqmm.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out Soft/loose Soil
Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm soil.
Removing excavated earth not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point.
Supply and filling pulverized stone dust to the full width of trenches for protection of cables including spreading and punning down including watering consolidation complete all as specified and directed.
Supplying and laying unreinforced precast cement concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm in trenches for cable protection embossed with Electric on the top surface complete all as specified and directed
Y Abulu
Priya construction
M/S KHUSHICONSTRUCTION
ANITA VARMA ENTERPRISES
Vandana Enterprises
M/s S U Enterprises
M/s Kamal Electrical
DEEPAK AGENCIES
CHANDER SEKER ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .