Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.6 LAccepted-AOC WARD NO 09 MAIN ROAD BURHAR SHAHDOL MADHYA PRADESH 484110 | BURHAR | SHAHDOL | MADHYA PRADESH | 484110 | ₹23.6 L Quoted ₹20.0 L | L-1 | Accepted-AOC Accepted as the bidder attains L-1 status |
| 2 | L-2₹23.5 LRejected-Finance GAYATRI SADAN PALI ROAD DIPKA DISTT KORBA C G 495452 | DIPKA | KORBA | CHHATTISGARH | 495452 | ₹23.5 L | L-2 | Rejected-Finance Rejected as the bidder attains L-2 status |
| 3 | L-3₹24.4 LRejected-Finance HARDI BAZAR DIST KORBA CG 495446 | KORBA | CHHATTISGARH | 495446 | ₹24.4 L | L-3 | Rejected-Finance Rejected as the bidder attains L-3 status |
| 4 | L-4₹29.6 LRejected-Finance BHAGWAN NIWAS WARD NO 30 DADARKHURD NEAR DADARNALA DISTT KORBA C G PIN 495682 | KORBA | CHHATTISGARH | 495682 | ₹29.6 L | L-4 | Rejected-Finance Rejected as the bidder attains L-4 status |
| Sl No | Description | Qty | Unit | m/s bhagwan saran and associates L4 | A. K. Rakesh (Arvind Kumar Rakesh) L2 | DINESH KUMAR L3 | M/S SATISH GUPTA L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of MS pipeline, Suitable for Size: 250mm including shifting from site to loading point, loading, unloading, transportation and placement as per instruction of Engineer Incharge | 6,000 | Mtr | 60 ₹3.6 L | 27.4 ₹1.6 L | 40 ₹2.4 L | 10 ₹60,000 |
| 2.00 | Laying and jointing of MS pipeline suitable for Size: 250mm including loading and unloading (within unit/project), transportation and placement, welding of pipes and cutting and fitting of packing (if jointing by nut bolt) which includes standard length pipes and short piece pipes | 10,000 | Mtr | 240 ₹24 L | 30 ₹3 L | 194 ₹19.4 L | 189 ₹18.9 L |
| 3.00 | Welding of tapered joints suitable for Size: 250mm at slope terrains/road crossings/locations for places where fixing of bends are not feasible, including cutting/welding and other allied works/places as directed by Engineer Incharge | 100 | No. | 95 ₹9,500 | 1,500 ₹1.5 L | 1,110 ₹1.1 L | 100 ₹10,000 |
| 4.00 | Welding for clitting of pipeline ranges suitable for Size: 250mm at slope terrains/road crossings/locations including cutting/welding and other allied works/ places as directed by Engineer Incharge | 350 | No. | 95 ₹33,250 | 500 ₹1.8 L | 110 ₹38,500 | 20 ₹7,000 |
| 5.00 | Making of bends, Size: 2500mm and fitting of the same in the pipeline by necessary welding works | 75 | No. | 1,450 ₹1.1 L | 7,500 ₹5.6 L | 799 ₹59,925 | 300 ₹22,500 |
| 6.00 | Welding charges wherever required as per instructions of Engineer Incharge | 1,00,000 | mm | 0.5 ₹50,000 | 10 ₹10 L | 0.5 ₹50,000 | 0.12 ₹12,000 |
| 7.00Note: 1). The estimated cost put to tender is excluding the PF and Pension Component. These statutory payment as applicable shall be reimbursed to the contractor on production of proof of payment limited to the maximum likely number of workmen to be deployed per day is 15 nos. 2). Industrial gas, welding electrodes, welding machine, vehicle mounted DG Set (Rating: Minimum 7.5 KVA and should be of sufficient rating which should be suitable for pipeline welding works) with diesel, tools and tackles, safety related gears/items etc. are in the scope of the contractor. 3). MS Pipes, Truck will be provided by the Department. 4). Quantity for item no. 1 & 2 will be considered as per unit of measurement i.e. running metre (irrespective of no. of pipes installed/dismantled) 5).Power Source (Vehicle mounted DG set (Rating: Minimum 7.5 KVA and should be of sufficient rating which should be suitable for pipeline welding works) with diesel) will be provided by contractor. | |||||||
| 8.00 | Total impact of GST for the purpose of CTC | 1 | Nos | - | - | - | - |
Tender Value
₹87.3 L
EMD Value
₹1.1 L
Closing Date
9 Feb 2026, 5:00 pmClosed
Staff Officer (EnM)
Office of the General Manager, Dipka Area, Ph. No. 9424141353
Shifting, diversion, extension of pipeline arrangement from New Chandni Chowk to Darra-Khacha coal face by dismantling, laying and jointing of pipeline for dewatering purposes for Old Dipka quarry sump at Dipka Expansion Project.
2026_SECL_351737_1
SECL/GM/DA/SO(EnM)/ e-tender/25-26/108 dtd-22/01/26
Open Tender
Electrical and Maintenance Works
75 days
Dipka Expansion Project, Dipka Area
Please refer to tender documents
5 documents required · 5 mandatory
₹1.1 L
15 Apr 2026
23 Jan 2026
11 Feb 2026
23 Jan 2026
9 Feb 2026
24 Jan 2026
23 Jan 2026 - 2 Feb 2026
Dismantling of MS pipeline, Suitable for Size: 250mm including shifting from site to loading point, loading, unloading, transportation and placement as per instruction of Engineer Incharge
Laying and jointing of MS pipeline suitable for Size: 250mm including loading and unloading (within unit/project), transportation and placement, welding of pipes and cutting and fitting of packing (if jointing by nut bolt) which includes standard length pipes and short piece pipes
Welding of tapered joints suitable for Size: 250mm at slope terrains/road crossings/locations for places where fixing of bends are not feasible, including cutting/welding and other allied works/places as directed by Engineer Incharge
Welding for clitting of pipeline ranges suitable for Size: 250mm at slope terrains/road crossings/locations including cutting/welding and other allied works/ places as directed by Engineer Incharge
Making of bends, Size: 2500mm and fitting of the same in the pipeline by necessary welding works
Welding charges wherever required as per instructions of Engineer Incharge
Note: 1). The estimated cost put to tender is excluding the PF and Pension Component. These statutory payment as applicable shall be reimbursed to the contractor on production of proof of payment limited to the maximum likely number of workmen to be deployed per day is 15 nos. 2). Industrial gas, welding electrodes, welding machine, vehicle mounted DG Set (Rating: Minimum 7.5 KVA and should be of sufficient rating which should be suitable for pipeline welding works) with diesel, tools and tackles, safety related gears/items etc. are in the scope of the contractor. 3). MS Pipes, Truck will be provided by the Department. 4). Quantity for item no. 1 & 2 will be considered as per unit of measurement i.e. running metre (irrespective of no. of pipes installed/dismantled) 5).Power Source (Vehicle mounted DG set (Rating: Minimum 7.5 KVA and should be of sufficient rating which should be suitable for pipeline welding works) with diesel) will be provided by contractor.
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
techsummary_364503.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.57 MB
Tendernotice_2.pdf
PDF • 1.29 MB
Tendernotice_3.pdf
PDF • 0.11 MB
BOQ_364503.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid