lead acid battery Average Turn Over of Last 3 Years 2 Lakh (s) Experience with Gov. Required 3 Year (s) Lead Acid Battery ( 40 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1
2 & 3) with latest amendments Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1
2 & 3) with latest amendments Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container ABS ABS
Polypropylene Rated Capacity at C20 discharge (AH) 26 26 Warranty (Years) 2 Years 2 Years Battery Condition Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 1470 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn.
corresponding Ah Yes. - 1/3 No.of cells per Battery (No.) 6 Cells for 12 Volt battery - CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab BANGALORE - Name of the Lab CPRI - Test Report No. 300EATDBT14S0042 - Test Report Date 11/09/2014 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells
and for Batteries made from them for use in portable applications N/A - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Chandra Dhameja N 110003
A BLOCK CGO COMPLEX NATIONAL INFORMATICS CENTRE NEW DELHI 40 35