Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹40.7 L+₹1.1 L (2.75%)Rejected-Finance MAIN ROAD RANJHI BAZHAR JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹42.7 L+₹3.1 L (7.90%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹45.3 L+₹5.8 L (14.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹45.4 L+₹5.8 L (14.6%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹47.9 L
EMD Value
₹95,700
Closing Date
4 Jul 2023, 5:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
SPL REPAIRS TO REPAIR/REPLACEMENT OF LT PANEL AND LT OH LINE INTO UG CABLE AND CONNECTED WORK CCTB GATE TO MH AND STC GATE 1 MTR AND 4 TTR UNDER GE (WEST) JABALPUR
2023_MES_601321_1
8588/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
7 documents required · 7 mandatory
₹500
GE (West) Jabalpur
₹95,700
19 Aug 2023
6 Jun 2023
10 Jul 2023
7 Jun 2023
4 Jul 2023
20 Jun 2023
8 Jun 2023 - 15 Jun 2023
Amount
Taking down of old unserviceable cable of any type upto and including 50 sqmm complete all as specified and directed
Dismantling existing ACSR (any size) from over head line completeall as directed by Engr-in-Charge.
Dismantling insulators of any type and any size complete all as directed by Engr-in-Charge.
Dismantling of cross arm(made of MS channels / angles etc.) or clamps etc.complete and stacking aside for re-use / replacement all as directed by Engr-in-Charge
Dismantling of stay assembly embedded in concrete and removing materials from site of work complete all as directed by Engineer-in-Charge.
Dismantling of old unserviceable service connection cable with GI wire and reel insulator complete all as directed by Engr-in-Charge.
Dismantling of existing GI earth wire any size complete all as specified and directed
Boring (Horizontally) existing road ( Maximum 10 mtr wide) suitable for passing GI tubing upto 80/100mm complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plain area and not exceeding 1.5m deep in Soft / Loose soil for laying pipes, cables, as in foundations, etc. complete all as specified and as directed.
Supply and laying Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. NOTE : Punned thickness only shall be measured and paid.
Supply and laying the Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge.
Removing excavated soils n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply , laying and testing cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core complete all as specified and directed by Engineer in charge
Ditto all as per item No 15 but size 10 sqmm 4 core
Ditto all as per item No 15 but size 16 sqmm 4 core
Ditto all as per item No 15 but size 25 sqmm 3.5 core
Ditto all as per item No 15 but size 35 sqmm 3.5 core
Ditto all as per item No 15 but size 50 sqmm 3.5 core
Ditto all as per item No 15 but size 70 sqmm 3.5 core
Ditto all as per item No 15 but size 95 sqmm 3.5 core
Ditto all as per item No 15 but size 120 sqmm 3½ core
Ditto all as per item No 15 but size 150 sqmm 3½ core
Ditto all as per item No 15 but size 185 sqmm 3½ core
Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 1000 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring . INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 630 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422009 OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 320 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422007 (b) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 250 Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420249 (c) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 160 Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420057 (d) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420053
(e) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos (f) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos (g) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No. (h) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber. (j) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos Make : Legrand, L&T, Hager, Havells (k) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos Make : L&T, Hager, Havells
(l) Current transformer (CT) of rating 250/5, tape wound, rated burden 5 VA - 03 Nos Make : CG/L&T/Siemens (m) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (n) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved ' Make of Panel - Asian Switchgear/ Tricolite/Universal Switchgear/ Mc Layer Pvt Ltd Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.
Design, supply, erection, commissioning and testing KIOSK outdoor type LT feeder pillar box, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Aluminium bus bar 800 Amps for distribution system and type tested at CPRI, complete with bus bars and control wiring . INCOMING : 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 500 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422008 OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 320 Amps, 415 Volts, 50 Hz. - 01 No Legrand Cat part No.422007 (b) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 200 Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420218 (c) 4 pole MCCB having breaking capacity 25 KA , adjustable overload, short circuit, instantaneous and neutral protection of rating 63Amps, 415 Volts, 50 Hz. - 02 No Legrand Cat part No.420053
(d) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos (e) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos (f) LED Pilot Lamp suitable for 230 Volts AC supply with integral circuit and cluster LED of following colours : (i) RED - 01 No, (ii) YELLOW - 01 No, (iii) BLUE - 01 No. (g) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber. (h) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos Make : Legrand, L&T, Hager, Havells (j) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos Make : L&T, Hager, Havells
(k) Current transformer (CT) of rating 250/5, tape wound, rated burden 5 VA - 03 Nos Make : CG/L&T/Siemens (l) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (m) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved ' Make of Panel - Asian Switchgear/ Tricolite/Universal Switchgear/ Mc Layer Pvt Ltd Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.
Design, supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 5mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947.
The bus bar chamber shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. (Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 500mm width and 450mm depth).
Supply, fixing and connecting PVC insulated, round,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size 1.5sqmm, 3 core, confirming to IS 694-1990 from street light junction box to Street light fittings by making two hole in the existing steel tubular poles
Supply and fix thermoplastic polycarbonate street light juntion box of size 200x160x98mm which is totally safe, shock proof, impact resistant, weather proof, dust proof, rust proof ,halogen and slica free, having internal embedded gasket technology made of PUR (Make Hensel), complete with IP 65 degree of protection with cable glands (Make AGRO) material polymide in and including the following :- Junction box Cat No K-9255 (box with 5 way Hensel terminal) and having metric knock out on 4 sides ) - 01 Nos,cable gland (cat No 1555.32.1.25)M32x1.5, 03 Nos, Lock nut (Cat No 8232,M32x1.5) - 03 Nos, MCB SP, 6 Amps - 01 Nos
M&L for GI Tubes, of following size, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed.
(a) 40 mm bore
(b) 50 mm bore
(c) 80 mm bore
ELCON
R K TRANSFORMER
H V ELECTRICALS
VEENUS ENGINEERS
mandeka constructions
RAVINDRA ELECTRICAL
shri krishna traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .