| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-01₹9.8 LAccepted-AOC | L-01 | Accepted-AOC Being lowest | |
| 2 | L-02₹9.9 L+₹1,426 (0.14%)Rejected-Finance | L-02 | Rejected-Finance Not being lowest | |
| 3 | L-03₹9.9 L+₹5,186 (0.52%)Rejected-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L-03 | Rejected-Finance Not being lowest | |
| 4 | L-04₹10.0 L+₹7,848 (0.79%)Rejected-Finance | L-04 | Rejected-Finance Not being lowest | |
| 5 | L-05₹10.0 L+₹12,234 (1.24%)Rejected-Finance | L-05 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹18,400
Closing Date
1 Jun 2021, 6:00 pmClosed
AGE (I) Darjeeling
P.O. Jalapahar Dist- Darjeeling (WB) Pin- 734103
REPAIR MAINT OF HEATING APPLAINCES AND EXHAUST FAN AT LEBONG UNDER AGE I DARJEELING
2021_MES_440346_1
8827/E8
Open Tender
Civil Works
Item Rate
182 days
AGE (I) Darjeeling
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Darjeeling
₹18,400
Yes
15 Jun 2021
4 May 2021
3 Jun 2021
4 May 2021
1 Jun 2021
19 May 2021
4 May 2021 - 11 May 2021
Amount
Labour only for Repair/maintanance of exhaust fan of any sweep by replacing unserviceable capacitor/ tightening the loose connections if any including testing, complete all as specified and as directed. Note: Capacitor of required capacity will be measured & paid under relavent item here-in-after.
Labour only for disconnecting and taking down Exhaust Fan of upto 450mm Sweep from Electrical Connections, cleaning Internally and Externally thoroughly, tightening the loosed Split Pins, Cotter Pins and Check-nuts, etc. overhauling, lubricating with approved Lubricants, re-assembling including replacement of wornout/defective Parts, re-fixing in Original Position after Minor Repairs for the smooth functioning and including electrically connected with Flexible Wire multi -stranded Copper Conductor Cable of size 0.5Sqmm twin core from Ceiling Rose to Fan and Testing, complete all as specified and as directed. NOTE: Necessary repairs/replacement of unserviceable Parts shall be measured and paid under appropreate Items as 'Supply only'.
M&L for disconnecting and taking down Exhaust Fan and removing from site for rewinding Exhaust Fan upto 380mm sweep of any Make with super enameled Copper Winding Wire as per existing size and gauge including heating, varnishing, replacement of unserviceable/worn out Parts for satisfactory Running including electrically connected with Flexible Wire multi-stranded Copper Conductor Cable of size 0.5Sqmm twin core from Ceiling Rose to Fan and Testing, complete all as specified and as directed
M&L for disconnecting and taking down Exhaust Fan and removing from site for rewinding Exhaust Fan exc. 380mm but upto 450mm sweep of any Make with super enameled Copper Winding Wire as per existing size and gauge including heating, varnishing, replacement of unserviceable/worn out Parts for satisfactory Running including electrically connected with Flexible Wire multi-stranded Copper Conductor Cable of size 0.5Sqmm twin core from Ceiling Rose to Fan and Testing, complete all as specified and as directed
M&L for Cutting hole through 0.6 mtr deep wall for fixing of exhaust fan in circular shape and making good the disturbed surfaces with cement morter plastering 1:3 including fair finishing and matching with existing colour of walls, complete all as directed by Engr-in-charge.
Supply only Capacitor 3.15 mfd (as approved) 230 Volts, AC, 50 Hz, complete all as specified and as directed. MAKE : SARDA/UNIVERSAL/USHA
Supply only Capacitor 3.5/4.0 mfd (as approved) 230 Volts, AC, 50 Hz, complete all as specified and as directed. MAKE : SARDA/UNIVERSAL/USHA
Supply only Gun metal Bush (as approved) suitable for Exhaust Fan of upto 380mm sweep complete all as specified and as directed.
Supply only Gun metal Bush (as approved) suitable for Exhaust Fan of upto 450mm sweep complete all as specified and as directed.
Supply only Ball Bearing (as approved) suitable for Exhaust Fans, complete all as specified and as directed. MAKE : NBC/SKF/TATA
Supply only Galvanised Mild Steel Split Pin and Jam nut of suitable size for Exhaust fan, complete all as specified and as directed.
S&F in-repair Metal Fan Blade for Ehaust fan, of any size (Same as of existing), complete all as specified and as directed. MAKE: BAJAJ/HAVELLS/ USHA
S&F Flexible Copper Cable PVC insulated unsheathed 0.5 Sqmm 2 Core, 230 Volts grade, complete all as specified and as directed. MAKE:- KEI/POLYCAB/FINOLEX/HAVELLS/RR KABEL
S&F in-repair non metalic Ventilating Fan 0f 150mm Sweep AC Single Phase 230 Volts, fixed in wall with necessary suitable cutting of hole and making good the distrubed surface areas and matching with existing colour of wall including provision of 0.5Sqmm 2 Core PVC insulated, unsheated multistranded copper conductor from Celing Rose to Fan Terminal, complete all as specified and as directed. Make:- Havells, Model:- Ventil Air-Dx White or equivalent of make BAJAJ/USHA/ ORIENT
S&F in-repair non metalic Ventilating Fan 0f 200mm Sweep AC Single Phase 230 Volts, fixed in wall with necessary suitable cutting of hole and making good the distrubed surface areas and matching with existing colour of wall including provision of 0.5Sqmm 2 Core PVC insulated, unsheated multistranded copper conductor from Celing Rose to Fan Terminal, complete all as specified and as directed. Make:- Havells, Model:- Ventil Air-Dx White or equivalent of make BAJAJ/USHA/ ORIENT
S&F in-repair modular power starter unit, 2-Module of capacity 16A, 240 Volt,AC, complete all as specified and as directed. Cat part no 6730 30 of Make Legrand or equivalent of Make- Havells/Anchor/Bajaj/ L&T/INDOASIAN
S&F in-repair modular power starter unit, 2-Module of capacity 25A, 240 Volt,AC, complete all as specified and as directed. Cat part no 6730 31 of Make Legrand or equivalent of Make- Havells/Anchor/Bajaj/ L&T/INDOASIAN
S&F in-repair Modular Socket Outlet, 3 Pin, Two Module, 16 Amp, 230 Volt, conforming to IS and connecting up, complete all as specified and as directed. Cat part no 6730 46 of Make Legrand or equivalent of Make- Havells/Anchor/Bajaj/ L&T/INDOASIAN
S&F in-repair Modular Socket Outlet, 3 Pin, Two Module, 25 Amp, 230 Volt, conforming to IS and connecting up, complete all as specified and as directed. Cat part no 6730 47 of Make Legrand or equivalent of Make- Havells/Anchor/Bajaj/ L&T/INDOASIAN
S&F in-repair PVC surface box with cover plate and frame, 2-Module, complete all as specified and as directed. Cat part no for surface box 6733 02 and for cover plate 6732 42 of Make Legrand or equivalent of Make- Havells/Anchor/Bajaj
Labour only for Repair/maintanance of Geyser of capacity upto 25 ltr by replacing unserviceable minor spare parts like thermostat, indicator lamp, heating element etc., tightening the loose connections if any including testing complete all as specified and as directed. (Note: spare parts required will be measured & paid under relavent item here-in-after)
All as per Item No. 21 here-in-above, but for Geyser of capacity exc. 25 Ltr and upto 50 Ltr, complete all as specified and as directed.
Labour only for lowering down unserviceable Geyser of 25Ltr capacity and any type by disconnecting all Electrical and Water Supply Connections, cleaning internally and externally thoroughly, repairing and brazing Inner Tank for Leak Proof where ever required, testing of leakages with Pressure Test, replacing the unserviceable Parts, re-assembling and installing the Geyser in Original Position and providing all neccesary Connections and Testing, complete all as specified and as directed. NOTE :- (i) Replacement of defective Parts shall be measured and paid under appropiate Items as ‘supply only’.
All as per Item No. 23 here-in-above, but for Geyser of capacity exc. 25 Ltr and upto 50 Ltr, complete all as specified and as directed.
Supply only Inner tank suitable for Geyser of 25 Ltrs capacity (Apparatus assembly) of copper made duly prewired, complete all as specified and as directed.
Supply only Inner tank suitable for Geyser of 50 Ltrs capacity (Apparatus assembly) of copper made duly prewired, complete all as specified and as directed.
Supply only Indication lamp (Green/Red) as required, complete all as specified and as directed.
Supply only Thermostat/Thermal cutoff suitable for Water Storage Geyser of range 0-90ºC as required, conforming to IS (Make as approved) complete all as specified and as directed.
Supply only Electro-plated Heating Element with provision of thermal cutoff (as approved), suitable for Electric Geyser of 1.5 KW capacity, 230 Volts, complete all as specified and as directed. MAKE : BAJAJ/RECOLD/THEETA/HAVELLS/USHA
Supply only Electro-plated Heating Element with provision of thermal cutoff (as approved), suitable for Electric Geyser of 2.0 KW capacity, 230 Volts, complete all as specified and as directed. MAKE : BAJAJ/RECOLD/THEETA/HAVELLS/USHA
Supply only Circular ring gasket as required suitable for Water Storage Geyser, complete all as specified and as directed.
Supply only Bottom plate as required suitable for Water Storage Geyser, complete all as specified and as directed.
Supply only Flange assembly (nine holes)as required suitable for Water Storage Geyser, complete all as specified and as directed.
S&F in repair Plug Top of 3Pin, 15/16 Amps capacity with indicator, complete all as specified and as directed. MAKE:- ANCHOR/L&T/HAVELLS
S&F in-repair of PVC Connection pipe of 450mm long (02 Nos) with brass connector series for both inlet and outlet of Geyser, complete all as specified ans as directed. MAKE:- PRAYAG/POLYTUF
Supply and fix in-repair of Stop Valve 15mm bore (dia), Cast Copper Alloy, Chromium Plated, (Consealed Type), screwed down, high pressure, with Crutch or Butter-fly Handle, screwed both Ends for Iron Pipe or for Unions and fixed, complete all as specified and as directed. MAKE:- Hindware/Marc/Prayag/Jaquar/Cera
Taking down carefully existing old unserviceable Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) of any description on batten/conduit (Serviceable Fittings such as Switches, Ceiling Roses, Pendants, Fan Regulators, Sockets, Light Fitting, etc. to be kept in safe custody for reuse) and making good disturbed surfaces of Ceiling, Walls, etc. with Cement Morter 1:3 and treating the surfaces so as to match the existing Finishes complete all as specified and as directed.
Taking down old unserviceable/burnt Submain Wiring with copper /aluminum conductor PVC insulated cable of any size drawn through PVC Casing Caping/Conduit including GI Wire Accessories etc. and making good disturbed surfaces of Walls, Ceiling, etc. so as to match the existing Finishes, complete all as specified and as directed.
M&L for Point Wiring with 1.5 Sqmm Copper Conductor single core PVC insulated FRLSH unsheathed 1100 Volt grade multi-stranded Cable drawn through and including PVC Casing & Caping of suitable size and its Accessories such as Elbow, bends, junction boxes, saddles and screws and rawalplug etc on Wall, Ceiling, mounted including PVC insulated FRLSH unsheathed single core multi-stranded Copper Conductor Cable of size 1.5 Sqmm Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One Light/ Fan/Exhaust Fan/ Bell Point controlled by One 1-Way Switch 5 Amp, complete all as specified and as directed. MAKE:- (i) Wiring cable- KEI/Havells/ Polycab/ Finolex/ RR Kabel (ii) PVC Casing caping- Modi/Presto plast/ Supreme/ Finolex/ Plaza
S&F Switch Piano, Flush type, Single Pole, 1-Way, 5 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed. MAKE- Anchor/ Havells/Legrand/ L&T
S&F Ceiling Rose, Surface Bakelite of size 65x50mm, 3 Terminals, AC, 50 Hz, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed. MAKE- Anchor/ Havells/Legrand/ L&T
M&L Sub-main Wiring with 2-Runs of Single Core 4.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 4.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed. NOTE :- (a) Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT. (c) Sub-main Wiring will be measured PVC Casing capping only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE. MAKE:- (i) Wiring cable- KEI/Havells/ Polycab/ Finolex/ RR Kabel (ii) PVC Casing caping- Modi/Presto plast/ Supreme/ Finolex/ Plaza
S&F in-repair of MCCB Four Pole (FP), 63 Amps, 415 Volts, 16 kA, 50 Hz, conforming to IS/IEC 60898 with with Sheet Metal Enclosure for MCCB FP and connecting up, complete all as specified and as directed. Make of MCCB FP enclosure and MCCB FP- Legrand cat part No.- 5078 01 & 4200 13 or Equivalent in L&T/ Schneider/ Havells
S&F in-repair of MCCB Four Pole (FP), 100 Amps, 415 Volts, 16 kA, 50 Hz, conforming to IS/IEC 60898 with with Sheet Metal Enclosure for MCCB FP and connecting up, complete all as specified and as directed. Make of MCCB FP enclosure and MCCB FP- Legrand cat part No.- 5078 01 & 4200 15 or Equivalent in L&T/ Schneider/ Havells
Supply and fixing in repair Busbar chamber 200A Triple pole neutral with colour coding, 6 way, complete all as specified and directed. Make: Havells, Cat No. IHBC020006 or equivalent of make Bajaj/ L&T/ Legrand/ Schneider
HIRA SINGH
Damdoo Bhutia
KWOK YING CHIU
RAI CONSTRUCTION
Darjeeling Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .