Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC Lowest Amount | |
| 2 | L2₹38.2 L+₹1.3 L (3.45%)Rejected-Finance | L2 | Rejected-Finance Not reasonable | |
| 3 | L3₹38.5 L+₹1.6 L (4.45%)Rejected-Finance D 16 OF HQ ADG P CHENNAI PLOT NO 97 SANTOSH NAGAR BALAJI NAGAR NEAR CURRENT OFFICE MEDCHAL MALKAJGIRI TELANGANA 500087 | MEDCHAL MALKAJGIRI | TELANGANA | 500087 | L3 | Rejected-Finance Not reasonable |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
3 Feb 2021, 6:00 pmClosed
Maj N P Singh
GE (West) Colaba, Mumbai
PROVISION OF FOOTPATH OVER STORM WATER DRAIN FROM MARSHAL HOUSE TO US CLUB, ADDITION / ALTERATION TO VISITORS TOILET AT RC CHURCH GATE, SPECIAL REPAIRS TO COOK HOUSE OF BLDG NO P 30 OF AYN AND CERTAIN REVENUE WORK UNDER GE WEST COLABA, MUMBAI
2021_MES_410937_1
8511/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Colaba
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (West)
₹86,000
Yes
9 Mar 2021
8 Jan 2021
5 Feb 2021
8 Jan 2021
3 Feb 2021
20 Jan 2021
Amount
Material and labour for providing two coats of Shalicryl 215 UV resistant elastomeric coating over Shaliurethane BTD bituminous modified elastomeric liqiuid membrane over polyester reinforcemnt over priming coat complete all as per manufacturer instructions and complete removal of previous water proofing treatment complete all as specified and directed. Note:- Rate of Removing & Refixing of water tank will deemed to be included in the unit rate quoted.
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in soft/loose soil , watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed.
Material and labour for PCC 1:3:6 (Type D 2) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Supply and fixing Rolled mild Steel work in tubular trusses (Square / rectangular / Round) including special shaped washer, gusset/bearing plate etc using ERW or induction, butt welded tubes conforming to IS 1239 part 1 and 2 grade St.-240 complete all as specified and directed.
Supply and fixing Rolled mild Steel Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) for columns, purlins, rafters and all other similar works conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
Supply and fixing Pre-painted roof sheet of mangalore tile pattern galvalume aluminium zinc coating GI based 0.50 mm thick of any colour/length having tensile strength of 550 MPA as in roof coverings having effective & overall width 1015 mm &1072 mm respectively, profile hieght 28.5 mm and centre to centre distance between ribs 203 mm fixed with self tapping screws on wooden/steel members including use of scaffoldings of any height complete all as specified and directed as per manufacturers instructions.
Supply and fixing Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPA as in roof coverings /claddings to wall, fixed with self tapping screws including use of scaffoldings of any height complete all as specified and directed.
Supply and fixing Polycabonate roof sheeting 10-12 mm thick (any Colour) hollow sheet, corrosion resistant, temper proof, durable coating, water proof sheet fixed with water proof fastening accessories, Aluminium foil tape, aluminium U profile, water proof tape, coach screw and washer in roof, wall etc complete all as specified and directed.
Material and labour for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of alkyd anti corrosive primer complete all as specified and directed.
Material and labour for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and labour for 100 mm thick plain cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in sub base to flooring and other similar works complete all as specified and directed.
Material and labour for light shade vitrified coloured Ceramic tiles, 10 mm thick (Square/rectangular) polished area of each tile not exceeding 0.36 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes complete all as specified and directed.
Material and labour for light shade vitrified coloured Ceramic tiles 10 mm thick (Square/rectangular) polished area of each tile not exceeding 0.36 sqm in vertical surfaces such as skirtings and dados set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including rendering 10 mm thick on fair faces of brick work in CM (1:4) complete all as specified and directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the primises out side MoD land complete all as specified and directed.
Material and labour for non Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer 15 mm thick in cement mortar (1:6) for laying floor finishes etc. complete all as specified and directed.
Material and labour for digital coloured glazed ceramic tiles 300x450x7mm thick in vertical surfaces such as skirting and dados set and jointed in neat cement slurry & pointed in coloured cement to match over and including rendering 10 mm thick on fair faces of brick work in cement mortar (1:4) for receiving vertical tiles complete all as specified and directed.
Material and labour for glazed finish chequred cement concrete coloured tiles of size 30 cm x 30 cm x 25 mm thick, set, jointed and pointed in neat cement slurry (with gray cement and pigment) laid over and including 20 mm thick in CM (1:6) for fixing tiles complete all as specified and directed.
Dismantling of Brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc complete all as specified and directed.
Material and labour for brickwork with subclass `B' bricks, straight or curved on plan exceeding 6.00 m mean radius, built in cement mortar (1:6) complete all as specified and directed.
Material and labour for brickwork except bricks, straight or curved on plan exceeding 6.00 m mean radius, built in cement mortar (1:6) complete all as specified and directed. Note: Old Bricks retrieved against item No 18 above shall be reused.
Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water etc upto 04 storeys height of bldgs including use of scaffolding arrangments complete all as specified and directed.
Material and labour for 15 mm thick rendering in CM (1:6) on fair faces of brick work and finished the surface even and smooth (without using extra cement) etc. complete all as specified and directed.
Material and labour for Rendering 15mm thick in cement mortar (1:4) using intergral water proofing compound on fair faces of brick work finished even and smooth (without using extra cement) complete all as specified and directed. Note: Integral liquid water proofing compound to be used in per bag of cement shall be as per manufacturers instructions and paid separately under respective items as supply only.
Supply only integral waterproofing compound complete all as specified and directed.
Material and labour for rendering 5mm thick on fair faces of ceiling / chajja concrete surfaces in cement mortar (1:3) complete all as specified and directed.
Material and labour for preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 2mm thick (average) Birla wallcare putty complete all as specified and directed.
Materials and labour for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 2mm thick (average) Birla wallcare putty complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces and applying two coats of 100% exterior grade acrylic paint (weather proof paint) over one coat of primer complete all as per manfacturers instructions and as directed.
Material and labour for preparation of old plastered surfaces and applying two coats of 100% exterior grade acrylic paint (weather proof paint) complete all as specified and directed.
Material and labour for prepartion of newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
Taking down chowkhats or frames not exceeding 1.50 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm single piece extruded PVC profiles reinforced with 19 x 19mm MS square tube provided with EPDM rubber gasket weather seal through out the frame and the profile mitre cut at two corners and joined by inserting 2 nos 150mm long brackets of 15 x 15mm MS square tube inside 19 x 19mm MS square tube suitably screwed complete all as specified and directed.
Supply and fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes of size 15 x 15mm for top and bottom rails and 19 x 19mm for stiles, MS frame covered with 5mm thick single piece extruded PVC profile 'C' channel having a 5mm thick PVC sheet strip of 20mm width struck inside with solvent cement, forming stiles, and 5mm thick single piece extruded PVC profile for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail; panelling of 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc all as per manufacturer's instructions and drawings as shown in SSR Part-I 2009 complete all as specified and directed.
Supply and fixing aluminium anodised barrel tower bolts of size 200 mm, extruded section complete all as specified and directed.
Supply and fixing aluminium handle, size 150 mm cast type anodised complete all as specified and directed.
Supply and fixing 100 mm butt hinges extruded aluminium alloy with galvanized mild steel hinges pin anodised type `C'-22 complete all as specified and directed.
Supply and fixing anodised aluminium frame/shutter for doors, windows, and ventilators of any type including sliding/hunge type all as directed with one more rebates including fabrication of frame/shutters and fixing to wall with necessary lugs, cleat ,powder coating (thickness of powder coating 50 micron) etc including all accessories such as glazing clips and rubber beading for fixing of glass panes, hinges, & handles etc complete all as specified and directed Note: Glass panes will be measured and paid seperately.
Supply and fixing anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges anodised aluminium snap beading, screws etc. complete all as specified and directed.
Supply and fixing Aluminum deco grill Cat No -104 6mm thick, cut to required size/shape and fixed in position with aluminium bedding complete all as specified and directed.
Supply and fixing in repairs counter sunk wash basin, snow white, oval shape 450mm x 350 mm complete all as specified and directed. Make:- CERA cat part No:S2030102 OR equivalent in Hindware / Prayag as approved by GE.
Supply and fixing in repairs 15 mm bore piller taps cast copper alloy, with capstan heads, chromium plated, screwed down, fancy type high pressure, with or without lettred 'HOT or COLD' with long screwed sunk and fly nuts complete all as specified and directed. Make:- CERA cat part No:F2002101 OR equivalent in Jaquar / Prayag as approved by GE.
Supply and fixing in repairs 15 mm bore fancy type bib taps long body cast copper alloy chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. Make:- CERA cat part No:F2002151 OR equivalent in Jaquar / Prayag as approved by GE.
Supply and fixing in repair 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. Make:- CERA cat part No:F2002201 OR equivalent in Jaquar / Prayag as approved by GE.
Supply and fixing in repair 15 mm bore fancy type concealed stop cock (regular body) cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. Make:- CERA cat part No:F2002361 OR equivalent in Jaquar / Prayag as approved by GE.
Supply and fixing PVC connection 15mm size PTMT nuts of length 450 mm complete all as specified and directed.
Taking up or down steel tubing and connections, 15 mm dia bore complete all as specified and directed
Taking up or down steel tubing and connections, 20 mm dia bore complete all as specified and directed
Fixing only old 15 mm bore steel tubing with all new fittings including cleaning, cutting, threading in positon (walls, ceiling and floor etc) complete all as specified and directed.
Supply and fixing GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Fixing only old 20 mm bore steel tubing with all new fittings including cleaning, cutting, threading in positon (walls, ceiling and floor etc) complete all as specified and directed.
Supply and fixing GI tubing 20 mm bore, medium grade with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Cutting chases, pinning in making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good, cutting not exceeding 10cm girth complete all as specified and directed.
Supply and fixing in repairs urinals spreader of PTMT any colour for fixing with 15 mm dia pipe (minimum wt 60 gms) fixed in position complete all as specified and directed.
Supply and fixing in repairs vitreous china, bowl urinal flat back, size 465 x 355 x 265mm white (min) with union and grating for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including providing fixing plugs, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement mortar 1:2 (excl fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed. Make:- CERA cat part No:F4020104 OR equivalent in Jaquar / Prayag / Hindware as approved by GE.
Supply and fixing in repairs 10 litre capacity PVC low level flushing cistern with all accessories fixed with WC including syphone pipe, PVC flushing pipe of size complete all as specified and directed. Make: Hindware / Prayag / Cera, sample as approved by GE.
Supply and fixing in repairs vitreous China wash down water closet pan (pedestal pattern) white, including trap, connection to drain and flushing pipe including seat cover for pedstal pan complete. Make:- CERA cat part No:F1053102 OR equivalent in Hindware / Prayag as approved by GE.
Supply and fixing in repairs fancy type CP Towel Rail 60 cm long complete all as specified and directed. Make:- CERA cat part No:F5003103 or equivalent in Jaquar / Prayag as approved by GE.
Supply and fixing in repairs CP Towel Ring complete all as specified and directed. Make:- CERA cat part No:F5003105 or equivalent in Jaquar / Prayag as approved by GE.
Supply and fixing in repairs CP soap dish complete all as specified and directed. Make:- CERA cat part No:F5003106 or equivalent in Jaquar / Prayag as approved by GE.
Supply and fixing in repairs CP toilet paper holder complete all as specified and directed. Make : CERA cat part No:F5004109 or equivalent in Jaquar / Prayag as approved by GE.
Supply and fixing sheet glass corner shelf assembly consisting of 5.5 mm thick sheet galss shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed.
Supply and fixing in repairs grating square 150mm size of PTMT(minimum 100 gms) complete all as specified and directed.
Supply and fixing stainless steel tube, channel, plates etc. made out of stainless steel sheet of grade X02Cr19NilO (316 S2), surface finish No. 4 as per IS 6911: 1992 as in framed work such as railing, walkway, staircase railing etc., welded suitably as per IS 5206: 1983 including necessary nuts, bolts etc. complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid, bedded and pointed in any mortar and removal of rubbish off the site out side MoD land complete all as specified and directed.
Material and labour for Granite stone (of any type and colour sample as approved by GE) 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid in floors/steps/Jambs/WHB counters and all other similar works in approved design over & including 20 mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
Material and labour for Machine cut kota stone slab flooring 20-25mm thick (sample as approved by GE) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over and including 20 mm thick screed bed in CM (1:6) complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situation complete all as specified and directed.
Supply and fixing in repairs 75 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls complete all as specified and directed.
Supply and fixing in repairs 110 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls complete all as specified and directed.
Supply and fixing in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes laid under floors complete all as specified and directed.
Supply and fixing 75mm bore PVC (SWR) bends with access doors any radius complete all as specified and directed.
Supply and fixing 110 mm bore PVC (SWR) bends with access doors any radius complete all as specified and directed.
Supply and fixing 75 mm bore PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specified and directed.
Supply and fixing 110 mm bore PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specified and directed.
Supply and fixing 75 mm bore PVC (SWR) vent cowl complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for cesspits, manholes etc. and getting out soft/loose soil even in foul position complete all as specified and direcetd.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation and getting out in any type of soil even in foul position complete all as specified and direcetd.
Returning, filling including spreading leveling watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B1, smooth finished and reforming benching as required for internal pipe of dia 150 mm complete all as specified and directed.
Material and labour for PCC 1:3:6 type C2, (using 40 mm graded stone aggragate) as in concrete bed to 150 mm bore drain pipe including packing under and haunching against the sides of pipes after pipe laid and tested, complete all as specified and directed.
Material and labour for 150 mm bore (internal dia of pipe) salt glazed stoneware drain pipe, grade A laid in trenches and jointed, complete all as specified and directed.
Supply and fixing 900mmx600mm FRP manhole cover of 20 Ton loading capacity with frame over manhole coping concrete complete all as specified and directed. Make :- Everlast/Vikrant, sample as approved by GE.
Material and labour for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all as specified and directed.
Material and labour for Mild steel bars TMT 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. Make: RINL / SAIL / TATA Steel.
Material and labour for RCC Type B1 (1:2:4) 20mm graded stone aggregate as in Slabs supported on walls, and all other similar works complete all as specified and directed.
Material and labour for rubber moulded glossy finished precast concrete interlocking paver block of any shape and size confirming to IS 15658 -2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushoning including compaction of paver blocks using surface vibrator complete all as specified and directed. Make : Vitco / Shriji / Mehtab / Ultra, sample as approved by GE
Material and labour for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. Make: RINL / SAIL / TATA Steel.
Cleaning of drains/culverts including removing and re-covering of RCC/CI/Steel covers by completely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land for width of drains exceeding 30 cm but not exceeding 60cm complete all as specified and directed.
Supply and fixing in repairs 300 mm dia bore reinforced concrete pipes, class NP2, (sample as approved by GE) laid and jointed with collar complete all as specified and directed.
Material and labour for providing precast cement concrete type B1 (1:2:4) using 20 mm graded stone aggregate, set in cement mortar (1:4) in road side kerb stones of any shape & size and all other similar works complete all as specified and directed.
Material and labour for PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate as in coping, bed concrete and all other similar work including necessary formworks complete all as specified and directed.
Dismantling plain or corrugated AC roof sheeting including Nainital or similar pattern roof coverings including scaffolding of any height complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Demolition of cement concrete in ground floor and paving not exceeding 15 cm thick (below or above GL) unreinforced, removing debries out side MoD land, complete all as specified and directed.
Material and labour for 75mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate, as in cook house floor and all other similar works, finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
Taking down shutter of any description exceeding 1.00 sqm and not exceeding 2.00 sqm each, upto 04 storeys height of bldgs complete all as specified and directed.
Supply and fixing Factory made 35 mm thick 2nd class hard wood, plain framed panelled shutters (any panel) with lock rail and panel of 9mm thick B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS :1003(Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
Supply and fixing 2nd class hard wood plain solid straight chowkhat and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joint complete all as specified and directed.
Supply and fixing sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty or fixed with rubber beading in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
Supply and fixing aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed.
Material and labour for PCC (1:3:6) type C1 using 20 mm graded stone aggregate as in bed blocks for hold fast and all other similar works including use of necesssary formwork complete all as specified and directed.
Supply and fixing mild steel flat iron as in hold fast clamps and all other similar works conforming to Fe 290. Gde -E-165 complete all as specified and directed.
Supply and fix butt hinges, extruded aluminium, with mild steel hinge pin, bright polished and fixed, type 75 mm size C21 complete all as specified and directed.
Supply and fixing aluminium anodised 150 mm long barrel tower bolts of extruded section complete all as specified and directed.
Supply and fixing 300mm long aluminium alloy, anodised sliding door bolt with haps, staple (bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
Material and labour for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new or previously untreated wood surfaces of any description not other wise described over 10 cm with or girth complete all as specified and directed.
Demolition of ceiling boards of any description, and any thickness including cover fillets and frame work complete all as specified and directed.
Material and labour for GI frame work for seamless ceiling 600x600mm grid size comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2m length) of 0.55 mm thickness having curved web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified and directed.
Material and labour 8 mm thick Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid (frame work for ceiling shall be measured and paid separately) fixed to aluminum frame work in ceiling and all other similar works complete all as specified and directed.
Material and labour for plain cement concrete (1:4:8) Type D2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Material and labour for Moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Material and labour for plain cement concrete type B- 2, (1:2:4) 40mm graded stone aggregate as in sub base floor 150mm thick, including use and waste of form work/screed strips and to divide the area in panels, finishing surfaces of concrete topping even and fair (without using extra cement) and finishing surfaces of concrete complete all as specified and directed.
Supply and fixing of 450 mm dia reinforced concrete pipes, class NP2 laid and jointed with collar complete all as specified and directed.
Taking down carefully copper/aluminum submain wiring complete including all fixtures such as switches, bulk head fittings, building security light fittings, plug socket boxes etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash/ OBD to match with existing surfaces etc complete all as specified and directed.
Supply and fixing Sub main wiring in repair (concealed type), with two run of 4 sq mm stranded copper conductor PVC unseathed FRLSH wire along with 4 sq mm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduite of 25 mm dia suitable size including cutting chases for conduits, sinking for boxes for concealed conduit wiring with all fittings and accessories for housing the wires for AC point complete all as specified and directed. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Mode of measurement two runs of 4 sqmm cable and one run of 4 sqmm cable with PVC conduite shall be measured as one length.
Taking down carefully copper/aluminum point wiring (Light point, fan point, 5 Amp socket point and per point) complete including all fixtures such as switches, bulk head fittings, building security light fittings, plug socket boxes etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed.
Material and labour for point wiring (concealed type) and including rigid non-metallic PVC heavy duty conduite, 20/25 mm dia suitable size, cutting chases for sinking for concealed boxes and concealed PVC conduite for wiring with 1.5 sqmm FRLSH PVC insulated, unsheathed, multi stranded copper conductor cable single core, 1100 volts grade with flush type metal boxes suitable for fixing switches, sockets and fan regulator etc., white or any colour cover plate with brass screws and cup washers including PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm as an earth wire connected to common earth and earth dolly complete and making good to the disturbed surfaces to match the existing surfaces complete (fill up cement in gaps, finishing with putti and apply two coats of paint, match with existing colour in disturbed surface area), as per IS specification and as specified in SSR Part-I complete for one light point / bell/ Exhaust Fan / wall fan controlled by one modular switch, 1 way 6/10 amps, 1 module. Make of Cable : Anchor / Havells / Finolex / Polycab, sample as approved by GE.
All as per item No. 119 above, but One ceiling fan controlled by one switch and regulator complete all as specified and directed.
All as per item No. 119 above, but One Exhaust fan / Wall fan controlled by one switch complete all as specified and directed.
All as per item No. 119 above, but One 3 pin socket point 5 Amps on independent board complete all as specified and directed.
All as per item No 119 above, but One 3 pin socket point 5 Amps on same board complete all as specified and directed.
All as per srl item No 119 above, but for one socket point 15 Amp with 2.5 sq mm PVC unseathed FRLSH wire along with 2.5 sq mm green colour wire as earth contuinity conductor connected to common earth dolly complete all as specified and directed.
Supply and fixing Switch piano, in repairs, flush type single pole, one way 5 Amp complete all as specified and directed. Make: Anchor/ Fine / SSK , sample as approved by GE.
Supply and fixing in repairs switch socket combination, 2/3 pin, 5 Amp complete all as specified and directed.
Supply and fixing in repairs switch socket combination, 6/16 A, 2/3 pin complete all as specified and directed.
Supply and fixing stepped type electronic fan regulator in repairs, 450 watt flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
Supply and fixing ceiling rose in repairs, surface bakelite 65 x 50 mm two to three terminals complete all as specified and as directed.
Supply and fixing 20 watt LED, 6500 K, in repairs, 4 feet long fixed including on pvc square for mounting the fittings and electrically connecting with three single core 23/0.0076. PVC insulated multi strandard copper flexible cable from ceiling rose to light fitting (connector block of lamp fitting) and one for earthing complete all as specified and directed Make:Havells cat part No LUMILINEBS20WLED830SPCWH equivalent model in Wipro model no - Wipro Garnet 20 W LED Batten 6500K / Philips model No - BN150W LED 20S-6500 PSE ODGR / OSRAM.
Supply and fixing in repairs LED building security light fitting 45 Watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency minium 100 luman per watt after all losses , pressure die-cast aluminium housing LED Street light complete with GI clamp including connected accessories and bracket made of GI Pipe 50mm dia light grade 1.25 m long, bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers etc. complete all as specified and directed. Make Philips : cat part No BRP409 LED060HENRPC S1PSU GR or equivalent in Wipro cat part No LR02-501-XXX-57-XX / Havells cat part No ENDURACITYLINERNEXGENSL 45WLED757 SASYBOPC.
Supply and fixing in repairs single pole and neutral enclosure, with a two pin and earth plug and socket 20 Amp with one single pole MCB complete all as specified and directed.
Supply, Laying, connecting, charging, testing and commissioning in repairs LT XLPE cable electric , PVC insulated, armoured, PVC sheathed, heavy duty, electric cable 1100 volt grade with stranded aluminum conductor of size 16 sq mm 2 core conforming to IS :1554, laid in trenches/ducts complete all as specified and directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Punned thickness of sand will be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV Type I, flat, size 250 mm x 150 mm x 40 mm laid in trenches complete all as specified and directed. Make : Mehatab/Janson.
Material and labour for GI tubing 50 mm dia bore, light grade, galvanized with all connecting fittings & fixtures (like suitable size of clamps, angle, nut & bolts) for holding of pipe with pole complete all as specified and directed. Make : Tata / Swastik / Jindal.
Supply and fix sheet metal enclosures in repairs, double door, for DBs when MCBs to be used 240 volts 12 way with 200 Amps rated bus bar single pole and neutral fixed on wall by cutting chasing and making good to the disturbed surfaced board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed.
Supply and fixing MCB SP in repairs, 240 volt, 6 to 32 Amps, C series, complete all as specified and directed. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
Supply and fix MCB SPN in repairs, 240 volt, 40 to 63 Amps, C series, complete all as specified and directed. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
Taking down main switch/DB’s including MCB’s with board and fixture of any description and making good disturbed surface of walls etc complete all as specified and directed.
Supply and fixing in repairs Switch piano, flush type single pole, one way 15 Amp complete all as specified and directed. Make : Anchor / Fine / SSK.
Supply and fixing surface mounted 10 watts, 6500K, in repairs, LED tube light fitting, mirror light fitting with lamp fixed including on pvc square for mounting the fittings and electrically connecting with three single core 23/0.0076. PVC insulated multi strandard copper flexible cable from ceiling rose to light fitting (connector block of lamp fitting) and one for earthing complete all as specified and directed. Make:- Wipro, Model No : Wipro Garnet 10W LED Batten 6500K or in equivalent model in Havells cat part No LUMILINEB59W LED830SPCWH / Philips model no BN021LED10S-2ft. / OSRAM.
Supply and fixing LED 36 Watt fitting in repairs, minimum 110 Lumin per Watt, recessed mounted, full glow, slim type, of size 60 cm x 60 cm square type, with electronic driver of same make connecting cable three core PVC insulated and PVC sheathed copper flexible cable of size 16/0 20mm and necessary fixing arrangement complete all as directed. Make - Havells (Cat part No - ENDURASLIMPROPLUS2X2 PLR36WLED840MOD) or equivalent model of Wipro Model No LM25-361-XXX-65-G1** / Philips Model No - RC380BLED 34S-6500 L60W60PSDOD-51.
Supply and fixing Exhaust Fans, AC, single phase 230/ 240 V, iron body, speed of motor 900 RPM, of size 300 mm sweep with louvers, including making hole in wall / fixing in existing frame and making electrical connections with stranded copper conductor cable of size minimum 0.5 sqmm from ceiling rose to fan connector, necessary clamps, nuts bolts and washers complete all as specified and directed. Make : Havells / Bajaj / Orient, model & make as approved by GE.
Supply and fixing in repairs sheet metal enclosures, double door, for DBs when MCBs to be used 240 volts 8 way with 200 Amps rated bus bar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed.
Supply and laying sub main wiring in repairs, for TPN DB to SPN DB with two run of 10 sqmm stranded copper conductor with one run of 10 sqmm stranded copper conductor wire (FRLSH) as earth continuty conductor connected to common earth dolly including adequate size of PVC conduit for housing the wires including taking out of old U/s sub main wiring of any size complete all as specified and directed. Note: Mode of measurement two runs of 10 sqmm cable and one run of 10 sqmm including PVC conduite cable shall be measured as one length.
RAJU AND CO
M/s Radhika Enterprises
Bidder Name
ASHOK CONSTRUCTION
RAJU AND CO
M/s Radhika Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .