Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹20.9 L+₹1.7 L (9.00%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-Finance High Rate | |
| 3 | L3₹21.0 L+₹1.8 L (9.31%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 4 | L4₹22.3 L+₹3.1 L (16.0%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹22.5 L+₹3.3 L (17.3%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
8 Jul 2023, 6:00 pmClosed
GE (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8421 REPAIR/REPLACEMENT OF INTERNAL WIRING FITTINGS FIXTURES AND CONNECTED ELECTRICAL ITEMS IN SINGLE LIVING ACCN 450/264 PERSONNEL LINE SINGLE OFFICER/JCOs/ORs/NURSING ACCN AT AFMC UNDER GE (CENTRAL) PUNE
2023_MES_604074_1
8421 REPAIR/REPLACEMENT OF INTERNAL WIRING FITTING
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (Central) Pune
As per Tender NIT
9 documents required · 9 mandatory
₹500
GE (Central) Pune
₹70,000
Yes
24 Jul 2023
17 Jun 2023
10 Jul 2023
17 Jun 2023
8 Jul 2023
26 Jun 2023
Amount
Notes For Following Items :- (a) The contractor shall detail electrician with helper for attending electric complaints at various locations in defence area including checking serviceability of elect items as required at site and as directed. (b) Contractor will deploy electrician with helper to attend complaint in AFMC Area alongwith necessary tools, safety equipments and transportation required to attend complaint. (c) Complaint will be attended on same day. (d) Electrician & Helper employed by contractor shall Possesses security pass all the time whenever on work shall be responsibility of contractor. (e) Subsequently sufficient store shall be procured by the contractor for day to day issue to complaint.
S & F Modular Switch flush type, single pole, one way, 6/10 Amps complete.
S & F Modular Switch flush type, single pole, one way, 15 Amp complete.
S & F Modular Switch flush type, single pole, two way, 6/10 Amps complete.
S & F Bell push modular 6 Amps complete all as specified.
S & F Modular Socket outlet multipurpose Socket, 6 Amps , 2/3 pin combined flush type complete.
S & F Modular Socket outlet multipurpose Socket 6A/16 Amps, 2/3 pin combined flush type complete.
S & F modular step type fan regulator single module 230 Volt 50 HZ, AC supply complete.
S & F modular step type fan regulator two module 230 volt 50 HZ, AC supply complete.
S & F Switch piano flush type, single pole, one way, and 5 Amp complete
S & F Switch piano flush type, single pole, two way, and 5 Amp complete .
S & F Bell push 6 Amp 230 Volt, 50 HZ , AC supply complete.
S & F Switch piano flush type, single pole, one way, and 15 Amp complete.
S & F Socket outlet multipurpose having provision for 2 in 1, 3 pin, 5 Amp flush type complete.
S & F Socket outlet multipurpose having provision for 2 in 1, 3 pin, 5 Amp and 15 Amp, flush type complete.
S & F Switch socket combination multipurpose 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete.
S & F Switch socket combination multipurpose 2 in 1, 5 Amps flush type universal complete.
S & F ceiling fan regulator socketed, stepped type, flush type, 230 Volts, AC supply complete
S & F Ceiling rose, surface Bakelite type, ISI marked for batten fitting complete all as specified.
S & F Lamp holder, PVC / Polycarbonate type with back plate complete all as specified.
S & F Bell Electric Ding dong type 230 Volt, 50 Hz , AC supply complete all as specified.
S & F capacitor 2.50 / 3.15 / 4.00 Mfd, 230 Volts, AC complete
S & F Plug top 3 Pin, 15 Amps, 230 Volts AC complete
S & F PVC surface modular box of size up to 6 module with modular plates inner and outer with each terminal including necessary fixing arrangements complete all as specified..
S & F PVC surface modular box of size 8 to 12 module with modular plates inner and outer with each terminal including necessary fixing arrangements complete all as specified..
S & F in replacement of surface mounted round LED down light fittings 18 Watt with aluminium die cast body, finished with drop down PC diffuser to deliver low glare illumination with optimised heat sink for efficient heat dissipation, 230 Volts with all accessories internally prewired and necessary mounting arrangements complete all as specified.
S & F in replacement LED Tube light fittings wall / Ceiling mounted, 20 Watt LED 6500K with Ultra bright LED Polycarbonate Tube light with very high efficiency provided with high efficient integral constant current LED Driver 230 Volts etc. complete with mounting batten including all accessories internally prewired and including provision of new 3 core multistranded copper conductor of suitable size from ceiling rose to fitting complete all as specified and as directed.
S & F in replacement for wall mounted 20 Watts indoor batten with opal diffuser, IP-20, with minimum 3 hrs back up with output of 1800 Lumens, powerful lithium battery, box type Polycarbonate light fitting, 230 Volts provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally prewired and necessary mounting arrangements including provision of new 3 core multistranded copper conductor of suitable size from ceiling rose to fitting complete all as specified. and as directed.
S & F wall / ceiling mounted LED batten tube light fitting, 10 Watts, , with out put of 1000 Lumens, 230 Volts with Polycarbonate housing with decorative end caps and intregrated electronic driver connector block etc complete with all accessories internally prewired and necessary mounting arrangements including provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 2' x 10 Watts complete all as specified. and as directed.
S & F LED Security light fittings of luminaires 24 Watt complete with all accessories and including wall mounting bracket of suitable size including clamps, nuts & bolts etc. including all accessories internally prewired including provision and connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 0.6 to 0.9 Mtr long bend to required shape with clamps, nut, bolts completeall as specified. and as directed.
S & F Sleek round recessed mounting LED downlight fitting 15 Watts with AL die-cast body, finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation, 230 Volts with integrated electronic driver connector block etc complete with all accessories internally prewired and necessary fixing arrangements including provision of new 3 core multistranded copper conductor of suitable size complete all as specified. and as directed.
Taking down Ceiling fan , sealing cable ends, dismantling blades and depositing to store yard of AGE E/M for reused complete all as directed.
Hanging only ceiling fan and connecting up including provision of cable fron ceiling rose or connnector to fan complete all as directed. Note :- (i) Ceiling fan taken down from Item No 32 above shall be used for hanging only. (ii) Necessary Receipt Vouchers / Issue Voucher shall be made after depositing of ceiling fan to store yard of AGE E/M and taken back for hanging only .
S & F in replacement of copper conductor PVC round sheathed (flexible) industrial cable 3 core, 1.5 Sqmm complete all as specified and as directed.
S & F in replacement of copper conductor PVC round sheathed (flexible) industrial cable 3 core, 2.5 Sqmm complete all as specified and as directed.
M & L for Sub main wiring complete with two single core 4 Sqmm, 1100 Volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of one run of single core 4 Sqmm drawn through in and including non-metallic PVC rigid conduit of suitable size including all accessories including taking down old unserviceable / worn out sub main wiring of any type complete including making good of disturbed surfaces all as specified and as directed. Note :- 2 runs of 4 Sqmm conductor, one run of 4 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
M & L for Sub main wiring complete with two single core 6 Sqmm, 1100 Volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of one run of single core 6 Sqmm drawn through in and including non-metallic PVC rigid conduit of suitable size including all accessories including taking down old unserviceable / worn out sub main wiring of any type complete including making good of disturbed surfaces all as specified and as directed. Note :- 2 runs of 6 Sqmm conductor, one run of 6 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
M & L for Sub main wiring complete with Four single core 4 Sqmm, 1100 Volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of one run of single core 4 Sqmm drawn through in and including non-metallic PVC rigid conduit of suitable size including all accessories including taking down old unserviceable / worn out sub main wiring of any type complete including making good of disturbed surfaces all as specified and as directed. Note :- 4 runs of 4 Sqmm conductor, one run of 4 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
M & L for Sub main wiring complete with Four single core 6 Sqmm, 1100 Volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of one run of single core 6 Sqmm drawn through in and including non-metallic PVC rigid conduit of suitable size including all accessories including taking down old unserviceable / worn out sub main wiring of any type complete including making good of disturbed surfaces all as specified and as directed. Note :- 4 runs of 6 Sqmm conductor, one run of 6 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
Taking down carefully aluminium point wiring (light, fan, socket or power), complete (fitting such as switches, sockets, holders, light fittings, fan requlators etc) and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked drawn through in and including heavy duty, PVC Conduit / casing caping of 25mm size including all accessories etc, with modular sunken / surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment, covered with modular white cover plate with frame suitable for modular switches or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
(a) One light / fan point controlled by one, one way switch complete all as specified and as directed.
(b) One light point controlled by two, two way switch complete all as specified and as directed.
(c) One bell point controlled by one, bell push complete all as specified and as directed.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one, one way switch on independent board complete all as specified and as directed..
(e) One 3 pin 5 Amps switch socket outlet point controlled by one, one way switch on the same board complete all as specified and as directed..
All as per Item No. 40 above but with multistranded copper conductor 2.5 Sqmm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volts grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated multistranded copper conductor 2.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked in PVC rigid conduits of 25mm size heavy duty ISI marked totally concealed in wall / floor / roof including all accessories etc, with modular sunken boxes with modular white cover plate with frame suitable for modular switches/ sockets and PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- Note - (i) Cutting in chases and pointing in will be done by contractor without any extra cost to the department. Rates quoted by the contractor shall deemed to be included of above provision.
(a) One light / fan point controlled by one, one way switch complete all as specified and as directed.
(b) One light point controlled by two, two way switch complete all as specified and as directed.
(c) One bell point controlled by one, bell switch omplete all as specified and as directed.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one, one way switch on independent board complete all as specified and as directed. .
(e) One 3 pin 5 Amps switch socket outlet point controlled by one, one way switch on the same board complete all as specified and as directed..
All as per Item No. 42 above but with multistranded copper conductor 2.5 Sqmm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volts grade ISI-694 marked for 3 pin, 15 Amps socket outlet, independent, including PVC insulated multistranded copper conductor 2.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. ..
Supply & Fix in replacement MCB TP / TPN rated capacity upto 40 Amps, 415 Volts breaking capacity 10 KA 'B' curve complete all as directed.
Supply & Fix in in replacement MCB TPN rated capacity upto 63 Amps, 415 Volts breaking capacity 10 KA 'B' series complete all as specified.
Supply & Fix in in replacement MCB SPN / DP rated capacity 32 Amps, 240 Volts breaking capacity 10 KA 'B' series complete all as directed.
Supply & Fix in replacement MCB SP rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA B Curve complete all as directed.
Supply & Fix in replacement MCCB TP 415 Volts 16 KA of capacity 63 to 100 Amps with extended spreaded terminals complete all as directed.
S & F in replacement sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 Volts suitable for fixing double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick / stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as directed.
S & F in replacement vertical type double door TPN DB 8 way IP-43 recess mounted / wall mounted type with incoming MCCB 3 Pole 25 KA 100 Amps and outgoing MCB SP 32 Amps suitable for single phase / three phase out going including including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as directed
S & F in replacement sheet metal enclosure MCB SPN DB 12 way with 200 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as directed.
All as per item No 51 above but MCB DB 8 way
All as per item No 51 above but MCB DB 6 way
All as per item No 51 above but MCB DB 4 way
S & F in replacement sheet metal enclosures single pole and neutral enclosure with a three pin and earth plug and socket complete with one MCB SP 20/32 Amps including removal of old unserviceable one complete all as directed.
M & L for Servicing / testing of Metering indoor building Panels, 03/01 Phase, 415/230 Volts all as specified and as directed as per followings. (i) Repair / replacement of damaged hinges and locks / latches of each compartment. (ii) Cleaning of existing bus bars with CTC with applying red solution, providing bus bar insulation & refixing with new nuts / bolts / washers etc. (iii) Replacement of damaged copper cable and fixing new copper cable for incoming and outgoing connections of each MCCB / MCBs switches alongwith lugs, terminals to bus bars including connector. (iv) Replacement of damaged cable protection pipe and damaged / wornout cable insulation and lugs of any size for incoming & outgoing cables (v) Replacement of neoprene gasket and transparent acrylic sheet 3mm for all doors of panel board. (vi) Repainting of panels after removing the rusting, scrapping, cleaning and drying the surfaces complete. (vii) Running welding wherever required (viii) Replacement of unserviceable MCCB / MCBs. (Note : MCCB / MCB shall be measured & Paid separately under relevant items) (ix) Removing, cleaning and refixing of electric meter including connection of concerned accn complete
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
M & L in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete
metro electrical services
shiva traders
Yashwanti electricals
Suchit constructions
PURVA ELECTRICALS AND ENGINEERS
ANUSHKA BUILDERS
M/S - SUJIT ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .