Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹36.8 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹37.1 L+₹30,230 (0.82%)Rejected-Finance 137 D6 ARAVALI HEIGHTS DPL DWARIKADISH ROAD DHARUHERA REWARI HARYANA 123106 | REWARI | HARYANA | 123106 | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹37.7 L+₹91,315 (2.48%)Rejected-Finance | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹40.8 L+₹4.0 L (10.8%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹40.9 L+₹4.2 L (11.3%)Rejected-Finance HYDERPORA NEAR ELLAQUAI DEHATI BANK SRINAGAR KASHMIR J K 190014 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190014 | L-5 | Rejected-Finance L-5 |
Tender Value
₹37.3 L
EMD Value
₹74,580
Closing Date
4 Feb 2025, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
PROVN OF DG SET OF CAPACITY 160 KVA FOR MI ROOM, QTY-03 FLAME PROOF LIGHTS AND QTY-04 AIR CONDITIONERS AT AFS DADRI UNDER AOR OF GE (AF) FARIDABAD
2024_MES_685404_2
GE (FBD)/AF-73/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dadri
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) FARIDABAD
₹74,580
Yes
26 Mar 2025
9 Jan 2025
7 Feb 2025
9 Jan 2025
4 Feb 2025
21 Jan 2025
9 Jan 2025 - 14 Jan 2025
Amount
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 240 sqmm 3.5 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc complete all as specified and directed. Note: (i) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways and Aluminium thimbles/lugs are incl in the quoted rates. (ii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
All as per item no 01 above but size 120 sqmm 3.5 core
All as per item no 01 above but size 70 sqmm 3.5 core
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed.
Returning, filling, including spreading levelling watering and well ramming in layers not exceeding 25cm apart complete all as specified and directed.
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed. Note: Punned thickness shall be measured.
M&L for sub class `B` bricks of nominal size, kiln burnt for cable protection complete all as specified and directed.
M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by charcoal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead GI Strip of 25 x 4.0 mm dia at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through GI pipe for protection of earth lead wire and arrangement of watering pipe incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover 40mm thick, RCC 1:2:4 using nominal mix reinforced 6 to 8 mm dia TMT bar @ 100mm C/C all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old unser earthing complete all as specified and directed. Note: Rate of Earth work, soil removal and filling are included in quoted rate.
Supply and fixing in repair of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip complete all as specified and directed.
Material and labour for fabrication of moveable trolley made out of mild steel for mounting of 160 KVA DG Set, AMF Panel along with HT/LT cable complete with 'I' - Hooks for hanging cables and moving arrangements so as to move the trolley both ways at 180 degree complete to move from one place to another and comprising of following components as appended below:- (a) Fabrication of chassis of moveable trolley made out of 6mm thick MS base plate of size 3.66 RM x 1.83 RM wide welded on (ISMC) heavy duty channels of size 200mm x 150mm of length 3.66 RM (02 Nos along with 4 Nos outer cover with inner cover incl rubber flap of size 7.5, 16 ply with steel rim of load capacity 1250 type wheels and steel rim with bearing and heavy duty axel of size 100mm x100mm of length 1.83 meter long - (02 Nos) (b) Moveable trolley enclosure made out of MS sheet of size 5mm thick welded all around the base platform of trolley of height 0.50 meter with back open-able shutter duly hinged (heavy duty ) and locking arrangements complete. (c) Suspension system of trolley made out of loaded leaf springs (step made patterns) - (04 Nos) made out of E-N 180 steel flat of size 100mm x100mm thick with varying length starts from 1.06 RM (Total flats 06 Nos/Per sheel) including cutting, welding grinding at the time of fabrication of jobs complete. (d) Complete trolley made out of MS sheet/channels/base plate/tyre rims shall be painted with 02 coats of syenthetic enamel paints (olive green) shade over a coat of red oxide primer with spray gun including preparation of steel sufraces complete all as specified ad directed. Note : The work shall be executed as per drg attached.
Supply, install, testing and commissioning of Eco friendly (CPCB-IV+) not less than 160 KVA Diesel Engine driven generating set with acoustic enclosure made out of CRCA Sheet powder coated, specially designed lifting arrangement/hooks, meet the latest CPCB norms of 75 dBA @ 1 mtr distance and as per the testing guide line of CPCB, DG Set shall be conforming to BS:5514 and alternator as per IS: 13364/IS:4722, water cooled type, self-starting system with 12 volt DC Supply, 3 phase 4 wire AC 415 volt + 5% at 1500 RPM, 50 Hz, 0.8 PF self-excited, self-regulated, Automatic voltage regulation, class 'H' insulation type alternator, With AMF (Automatic mains failure) panel for automatic starting at mains failure installed with the following accessories complete all specified and directed by Engineer-in-Charge. (A) Engine Adequate capacity of Diesel Engine, 4 stroke, 1500RPM, 6 Cylinder, not less than 160 KVA Prime Duty, Eco friendly for emission and noise ( CPCB-IV+ NORMS COMPLIANCE) diesel engine confirming to BS/IS standard developing suitable BHP @ 1500 RPM water cooled complete under NTP condition with a provision for 10 % overload for one hour on 12 hours running complete with standard accessories all as specified and directed for safe handling and operation, salient features shall be as under :- (i) Fly wheel with housing (ii) Cooling system :- Mounted radiator with fan & belts. (iii) Cooling Water pump : - Centrifugal type belt driven. (iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable mm dia with MS pipe light grade up to and away (as per CPCB norm) from the enclosure to be erected, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure.
Item No 13 contd..../- (a) Exhaust gas turbo charger type, (b) Exhaust manifold, (c) Silencer: Residential type, (d) Bellows (v) Fuel System: - (a) Fuel injection system with fuel injectors, fuel injection solenoid switch/ nozzles/ governor electronic type capable for 1% speed /frequency regulation. (b) Fuel filters, (c) Fuel hoses (vi) Lube oil System: - (a) Lubricating oil filter, (b) Lubricating oil pump (vii) Air Intake System: - (a) Air intake Manifold, (b) Air cleaner dry type (viii) Governor: - Electronic Governor (ix) Starting System: - Electric Self-starter with maintenance free batteries including battery charging set. (x) Batteries :- (a) 1 Nos, maintenance free Batteries of 12 Volt 180 AH capacity complete with copper conductor multistranded leads of suitable length from self-starter to the battery terminals complete with initial charge and initial fill of electrolyte, (b) Starter gear ring, (c) Start and stop push button, (d) Ignition key / Switch (xi) Handling and operation : Salient features of accessories shall be as under: (a) Radiator with blower fan, (b) Corrosion inhibitor coolant, (c) Paper element filters for fuel, lube oil and by pass, (d) Electronic governor controlled direct fuel injection system or as per OEM standard (xii) Generator Monitoring Panel: Comprising of following:- (a) Microprocessor based genset controller for metering, monitoring, governing and protection. (b) Engine protection for low lube oil pressure, high coolant temperature (alarm & shutdown), (c) Alternator protection parameters like under voltage, over current, under frequency, over frequency ( alarm & shut down), (d) Relay drivers for remote annunciations, (e) Cyclic cranking, (f) Auto/manual start/ stop, (g) Alternator trim adjustment from the front key pad, (h) operates within a temperature range 0- 60 degrees C and humidity up to 95% ,
Item No 13 contd..../- (j) Remote monitoring capability through separate interface modules, (k) Genset metering parameters like lube oil pressure, coolant temperature, engine speed(rpm), run hours, DC voltage, intake manifold temperature, 3 phase volts and 3 phase amperes, frequency, KW, KVA, power factor etc. (xiii) Safety Controls : - Engine low lube oil pressure, high water temperature and over speeding of engine. (xiv) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling fly wheel housing. (xv) Accessories :- AVM Pads built or separately mounted to manufacturer base frames. (xvi) Base Frame : - Made out of Formed C Channel 2.5/3mm thick CRCA Sheet or ISMC 250 of sturdy design made of MS channel with necessary reinforcement and predetermined holes. (xvii) Fuel Tank :- Daily service fuel tank made out of 2mm thick MS sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base within the Acoustic Enclosure. (B). Alternator: - Standard design alternator rated at not less than 160 kva net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self-excited self-regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 4722/13364 and shall be imposition to generate supply with frequency regulation within + 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/ IS - 4722(i) Insulation class - 'H' (i) Temperature rise Class - 'H' (ii) Excitation : Self Excited (iii) Regulation performance: The voltage is kept constant with + 1%, manual voltage adjustment within + 5% . (iv) Frequency regulation + 1%
Item No 13 contd..../- (i) Custom built product for various equipment’s, with ensure the optimum performance without duration. (ii) Rugged in construction maintenance free and modular designs which facilitate easy at site. (iii) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality acoustic insulation materials to be used for maximum sound absorption. iv) Sheet metal components of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action. (v) Special paint treatment with pure polyester powder / epoxy to be provided for better weather resistance. (vi) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently. (vii) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to used. (viii) Working space is to be provided around the equipment for easy maintenance / repairs. (ix) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per the requirement. (x) A see-through transparent window (glass or acrylic) in front of engine panel to provide for monitoring the operation. (xi) Ducting if required, bellows, mechanical hardware like locks, hinges fasteners etc to be provided. (xii) Deliverables. 75 dBA @ 1mtr at 75% load under free field conditions. The temp inside the enclosure will be within 7 Degree above ambient temp. (xiii) The enclosure should be provided with bulk head light fitting for inside illumination (xiv) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated plat form. (xv) The DG Set should be provided with external Emergency stop push button. (xvi) The acoustic enclosure parts shall be of 80 microns powder coated after 11 tank pre-treatment process. The powder coating shade should be as per OEM standard. Note: (i) Fuel and any other equipment required for testing shall be provided by the contractor.
Supply and install hi wall split units (1.5 ton) indoor and outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 ton complete all as specified and directed.
Supply & fix Voltage stabilizer for automatic operation single phase naturally air colled indoor type &designed for input variation between 170 volts to 250 volts with output voltage stabilized at 230 with accuracy of +-2.5% and capacity 5 KVA complete all as specified and directed.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole 20 amps MCB complete all as specified and directed.
M&L for submain wiring with 2X4.0 SQMM+1X4.0SQMM Earth Wire single core PVC insulated FRLSH sheathed copper cable connecting to common earth dolly in and including heavy duty PVC Cascing & Caping all accessories complete all as specified and directed. Note : Two run of 4 sqmm main wire one run of 4 sqmm earth wire and one run of PVC casing/caping will be meausred as one runnning meter for the purpose of measurment and payment.
Supplying ,laying and testing XLPE cable insulated screened, PVC bedded galvanized steel strip of wire armored , electric power cable (Heavy duty ) 1100 volts grade with stranded aluminum conductorof size 50 sqmm 3.5 core complete all as specified and directed.
S & F in repairs single pole and neutral sheet metal enclosures for Distribution board (DB's)suitable for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail 240 V, 50 Hz supply double door SP&N DB system 12 ways complete all as specified and directed.
S&F MCB TPN 40-100 Amps 240V incl all termnials, fitting etc complete all as specified and directed.
S&F MCB SP 06 to 40 Amps 240V incl all termnials, fitting etc complete all as specified and directed.
M&L for point wiring with two runs of 1.5 sqmm Single Core copper conductor (Flexible) Industrial Cables HFFR compound insulated (Unsheathed),1100 Volts Generally confirming to IS: 694 insulated stranded copper conductor cable drawing in stove enammeled steel conduit incl tees, bends, junction boxes surface wiring on wall ceiling with suitable clamps of medium grade ISI marked not less than 20mm dia alongwith 1.5 sqmm PVC insulated stranded copper conductor cable for continuous earth wire connected to main earth dolly with provn of pressed steel terminal box of suitable size as per site requirement with one light point/fan point controlled by one switch complete all as specified and directed.
Supply and fixing LED light fitting 2x16 Watt ( 4 feet )flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specified and as directed.
S&F switch flameproof rotary type with termination box in LM6, 16 A, single pole 250 V complete all as specified and directed.
M&L for rigid stove enamelled conduit welded not less than 20 mm dia medium grade incl tees bends etc fixed with suitable clamps with proper screws complete all as specified and directed.
S&F junction box flame proof 20 mm terminals with threaded cover of complete all as specified and directed.
S & F flame proof distribution board SPN 06 way with Bus bar weather proof in cast aluminium LM-06 enclosure operated by externally spring type knobs , complete with M-25 cable entry to suit incoming cable and 08 Nos M-20 cable entries for out going from bottom, suitable for fixing on wall/column /steel structure duly epoxy powder coated with flame proof flexible metallic conduit up to 01 Mtr length complete all as specified and directed. INCOMING (a) MCB SPN-40 Amps-01 No OUTGOING (a) MCB SP 6 Amps -02 No (b) MCB SP 16 Amps-02 Nos
Supply & Laying connecting of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured LT 1100 Volts grade aluminium conductor of cross sectional area 10 Sqmm 2 core incl thimbles as required with suitable size of clamps on wall/under trenches etc all as specified and directed.
Shrikanth Solutions (BID ID -3231333)
Surjit and Sons (BID ID -3224299)
Rahul Enterprises (BID ID -3222198)
M/S ZAHOOR AHMAD KHAN (BID ID -3227792)
Natwadia Electrical Company (BID ID -3228706)
Electromech Engineers (BID ID -3225800)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .