Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹38.5 L+₹75,250 (1.99%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹39.5 L+₹1.8 L (4.67%)Rejected-Finance MB 58 JUNGLIGHAT KATHIR MARKETING SERVICE MB 58 JUNGLIGHAT NEAR TCI OFFICE SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹39.6 L+₹1.9 L (5.06%)Rejected-Finance 30 M A ROAD M A ROAD PHOENIX BAY SOUTH ANDAMAN ANDAMAN NICOBAR 744102 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744102 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹39.7 L+₹1.9 L (5.11%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
10 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I)866 EWS CARNICOBAR
GE(I)866 EWS CARNICOBAR C/O 99APO 913866
REPAIR / MAINTENANCE OF AC PLANTS AND SUMMER COOLING APPLIANCES AND ITS PERIODICAL MAINTENANCE AT AF STN CARNICOBAR.
2022_MES_540333_2
8611/E8
Open Tender
Civil Works
Item Rate
330 days
Area under GE(I)866 EWS CARNICOBAR
As per Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE(I)866EWS
₹72,000
Yes
26 Oct 2022
20 Aug 2022
15 Sept 2022
20 Aug 2022
10 Sept 2022
27 Aug 2022
Amount
M&L for servicing of complete unit (indoor and out door) of air cooled split type AC of any make, capacity through Ref Mechanic having min 5 yrs. experience by using blower, cleaning of condenser coil with water, checking all the parts, electrical connection, cleaning the air filters, combing of fins by using fins comb including replacing defective filters, burnt wiring, tightening of electric wiring connections, etc as reqd at site, as specified by OEM & directed by Engr-in-charge. Note:- Cleaning material, minor parts like connector, thimbles, piece of wires etc shall be included in quoted rates.
M&L for replacement of existing old unserviceable nitrile rubber insulation of refrigerant pipes of split type air conditioner up to 2 TR cap all as specified and directed. Make: Armacell / Armaflex and equivalent
M&L for replacement of micro processor printed circuit board (PCB) complete suitable for split type AC's as per existing make & model up to 2 TR Cap complete all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable PCB of indoor / outdoor unit of Inverter type Split AC upto 2TR as per existing make & model complete all as specified and directed by Engr in Charge.
M&L for replacement of unserviceable starting capacitor 80 / 100 mfd suitable for deep freezer / window type / split type AC's as per existing cap all as directed. Make: Sharda and equivalent
M&L for replacement of unserviceable running capacitor 30 / 36 / 40 / 45 / 50 / 55 mfd suitable for split /window / refrigerator / deep freezer / water cooler type AC's 1 to 2 TR cap of existing make & model all as directed. Make Sharda and equivalent
M&L for replacement of capacitor 2.5 / 3 / 4 / 6 mfd suitable for fan motor of (split / window / water cooler fan motor). Make Sharda and equivalent.
M&L for replacement of unserviceable swinging motor of indoor unit of split type AC up to 2 TR capacity suitable for existing make / model / type complete all as specified and directed by Engr in charge. Make LG or as per existing make
M& L for replacement of condenser fan / blower motor with bush and washers as per existing make and model for split type AC up to 2 TR Capacity complete all as specified and directed. Make Crompton Greaves / Havells / Kirloskar or equivalent.
M&L for replacement of existing unserviceable compressor unit with new Rotary / Scroll Compressor unit as per existing type & model including taking out the old u/s burnt out Compressor of split type Air Conditioner, unserviceable replacement of bushes, sleeves, washers nut and bolt, relay terminal cover, clips reqd for fixing of new compressor, cutting, brazing of copper piping, charging of suitable refrigerant gas as required Qty to obtained desired cooling, carry out leak test etc., all as required at site complete for following capacity:- Make: Hitachi / Copeland / Tecumsha / LG / Voltas
Capacity 1.5 TR
Capacity 2.0 TR
M&L for replacement of unserviceable fan blade of condenser unit of split type AC up to 2 TR as per existing type and model complete all as directed by Engr-in-charge. Make LG, Bluestar and its equivalent or as per existing make.
M&L for leak detection by nitrogen pressure test in refrigerant system of AC, incl. cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable refrigerant / gas per existing grade as required quantity to achieve desire cooling complete all as specified an directed-
Split type AC 1.5 TR capacity
Split type AC 2.0 TR Capacity
M&L for replacement of unserviceable contactor kit of split type AC as per existing make & model up to 2 TR complete all as specified and directed. Make Havells ,LT, legarand or as per existing.
M&L for replacement of unserviceable copper tubing 5/8" dia with nitrile rubber insulation, cutting, flaring, brazing mail, female brass nuts as required at site. Make Godrej / Malaysia / Johnson and equivalent.
M&L for replacement of unserviceable copper tubing 1/2" dia with nitrile rubber insulation, cutting, flaring, brazing mail, female brass nut as required at site. Make Godrej / Malaysia / Johnson and equivalent.
M&L for replacement of unserviceable copper tubing 3/8" dia with nitrile rubber insulation, cutting, flaring, brazing mail, female brass nut as required at site. Make Godrej / Malaysia / Johnson and equivalent.
M&L for replacement of unserviceable copper tubing 1/4" dia with nitrile rubber insulation, cutting, flaring, brazing mail, female brass nut as required at site. Make Godrej / Malaysia / Johnson and equivalent.
M&L for replacement of unserviceable power cable cord PVC flexible copper wire 2.5 sqmm 4 core incl. lugs / thimbles. Make Finolex / Havells / Polycab and equivalent.
Labour only for rectification of water leakage problem of AC unit by cleaning indoor unit & drain pipe of split type AC up to 2 Ton cap complete all as specified and directed
M&L for replacement of unserviceable gun metal valve 5/8" / 1/2"of split type AC up to 2 TR cap. Make Sant / Zoloto / Leader and equivalent
M&L for replacement of unserviceable gun metal valve 3/8" / 1/4"of split type AC up to 2 TR cap. Make Sant / Zoloto / Leader and equivalent
M&L for replacement of unserviceable thermostat suitable for water coolers, Window type AC's / split AC's, refrigerators and Deep freezers any capacity, type & model all as directed as reqd at site & directed by Engr-in-Charge.All As per existing make.
M&L for replacement of starting relay suitable for water coolers, refrigerators and Deep freezers any capacity, type & model all as directed. Make L&T / Havells / Legrand and equivalent
M&L for servicing of water cooler of installed capacity 40 / 80 Ltrs, through Refg mechanic having min 5 yrs. experience by cleaning the tank, condenser coil, oiling the fan motor, checking all parts, repair to electrical burnt/loose connection, replacement of rubber gasket of top cover, washer minor u/s parts etc. all as specified by OEM & directed by Engr-in-Charge.
Supply and fix hermetically sealed rotary / scroll unit new Compressor by dismantling burnt out u/s Compressor suitable for water coolers of 40 / 80 Ltr capacities including provn of bushes, sleeves, washers nut and bolt for 4/3 Compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging suitable refrigerant and commissioning testing. Make:- Emerson / Carrier / Tecumsha/ LG/Voltas as reqd qty to achieve desired cooling.
M&L for replacement of freezer with PVC door suitable for refrigerator having capacity 165 to 310 Ltr as per existing type, model including cutting, brazing complete all as specified & directed by Engr in Charge.
M&L for replacement of push cock of 15 mm dia for water coolers
M&L for replacement of unserviceable float valve for water cooler 40 / 80 Ltrs capacity any as per existing size and type complete all as specified and directed
Servicing of air curtains, single phase, 240V by checking all electrical connection, blower, motor oiling greasing and replacement of u/s wire, lugs, bushes, rubber pads, bearing etc. all as directed by Engr-in-charge.
M&L for replacement of hermetically sealed / Rotary Compressor by dismantling burnt out u/s Compressor suitable for refrigerators including provn of bushes, sleeves, washers nut and bolt for 4/3 Compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging suitable refrigerant and commissioning testing for the following capacity. Make Hitachi / whirlpool / Tecumsha / LG
165 - 200 Ltrs capacity
285 - 300 Ltrs capacity
M&L for leak detection in refrigerant system of Refrigerator (165 to 300 Ltrs cap) including cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas as required quantity complete all as specified and directed.
M&L for replacement of condenser coil of refrigerator cap 165 to 310 Ltr cap as per existing type & model including cutting, brazing ,charging of refrigerant gas as required qty and leak detection complete as specified & directed by Engr in Charge
M&L for replacement of cooling coil of refrigerator cap 165 to 310 Ltr cap as per existing type & model including cutting, brazing ,charging of refrigerant gas as required qty and leak detection complete as specified & directed by Engr in Charge
Labour only for taking out existing split type air conditioners of any type and capacity removing from the site and keeping it in a safe custody for re-use or deposit in store all as specified and directed.
Fixing only split type air conditioners of any type and capacity including core cutting for passing copper tubing , drain pipe & cable through wall with connected accessories such as mounting bracket with fasteners, copper tubing & elect power cord cable from indoor to out door unit and drain water pipe etc as per site requirement all as specified and directed.
M&L for replacement of old unserviceable outdoor unit of split type 1.5 TR Cap having copper tubing, high EER rating compressor , blower motor etc. complete including, making elect, refrigerant piping connection, brazing, leak testing and incl charging suitable refrigerant gas to achieve desired cooling effect and testing complete all as specified and directed. Make- Blue Star / Voltas / Hitachi / Daiken
M&L for replacement of unserviceable indoor unit of split type AC 1.5 TR complete suitable for (R-407/410/32) gas complete including making all connections, making good to the disturbed surface matching to existing specification. Make- Voltas / Blue Star / Hitachi / Daiken
M&L for replacement of unserviceable MCB SP C series 20 A to 32 Amp breaking capacity 10 kA. Make - L&T / Legrand / Siemens
M&L for replacement of Metal plug 20A, 2Pin+SC Make: L&T / Legrand / Havell's
M&L for replacement of Metal socket 20A, 2 pin+SC Make: L&T / Legrand / Hager / Havell's
M&L for replacement of unserviceable sheet metal enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole C series MCB 20 Amps, 240 volts all as specified and directed. Make: L&T / Legrand / Hager /Havel's
M/L for sub main wiring with two runs of single core 4.0 Sq. mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.0 Sq. mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & capping all as directed and specified. (Note:Two runs of 4.0 Sqmm copper cable, one run of earth wire of 4.0 Sqmm copper cable shall be measured & paid as one length). Make Finolex / Polycab / Finecab / Havells or equivalent.
M&L for replacement of unserviceable condenser cooling coils of Split type AC up to 2 TR cap with new copper coil including , cutting, brazing, and making leakproof & Charging suitable refrigerant as required qty to achieve desired cooling complete all as reqd at site and specified by Engr in Charge. Make Bluestar / LG and equivalent or as per existing make.
M&L for replacement of unserviceable motor of air curtain as per existing make and model including replacement of bush, bearing etc as reqd at site complete all as specified & directed by Engr in Charge
M&L for replacement of unserviceable drain flexible PVC pipe of split type AC complete all as specified and directed by Engr in Charge
M&L for replacement of unserviceable filter of refrigerant lines of split AC / Water cooler / Refrigerator / Deepfreeze including brazing complete all as specified and reqd at site. Make Bluetstar / LG or as per existing.
M&L for replacement of overload relay suitable for Deep freezer, Water cooler, Refrigerator complete all as specified & directed by Engr in Charge. Make LG / Bluestar and equivalent
M&L for replacement of unserviceable PCB for refrigerator suitable for 165 to 310 Ltr cap as per existing make, model & type complete all as directed.
M&L for replacement of unserviceable PCB for deep freezer up to 450 Ltr cap as per existing make, model & type complete all as directed.Make as per existing.
M&L for replacement of PVC pipe 20mm dia heavy duty with all fittings (bend, elbow, tee) etc including fixing with clamp on wall or floor for AC drain line complete as directed. Make Astral / Prince and equivalent.
M&L for replacement of outer corroded body of split type AC 1.5 to 2 TR cap including taking down the outdoor unit, and fixing new outer body made out of 20 SWG GI sheet duly painted and refixing to its original position complete all as required at site directed by Engr in Charge
M&L for spray painting after necessary scraping out the old bubbled paint by wire brush, emery paper, cleaning agent, cleaning, preparing the surface even by applying putty and apply two coat of super enamelled paint over one under coat of red oxide paint as per existing colour and writing MES complete all as reqd at site & directed by Engr in Charge.
M & L for replacement of MS Stand duly painted for outdoor unit of split AC with fasteners complete all as reqd at site & directed by Engr in Charge.
M&L for replacement of single phase Axial fan motor 220V, 50 Hz, 0.42A, 90W, 1350 RPM CE certified weather proof colling coil motor suitable for cold storage 0 to -18 deg. Make- Osaka Shoji Kaisha Ltd / HI cool
M&L for replacement of unserviceable digital controller model No BSL52 of Blue Star suitable for cold storage 1/1.8 Ton cap having -2 to 10 oC temp range complete with sensor & control wiring. Make- Blue Star
M&L for replacement of unserviceable digital cold room temp controller model CCR-2052 with MCB of Sub Zero suitable for cold storage 1.8 Ton cap having -0 to -18 oC temp range complete with sensor & control wiring Make - Sub Zero
M&L for replacement unserviceable of SS hinges of cold storage unit as per existing type & model complete as required at site & directed by Engr in Charge. Note: Two no's of SS hinges for bottom and top measured as one unit. i.e., 'Each Set'
M&L for replacement of unserviceable door stoper of cold storage as per existing type & model complete all as specified & directed
M&L for taking out existing unserviceable scroll compressor and replace with new compressor of cold storage suitable for working on 380-415V 3 phase , 50Hz, LR 74A, Max Oper-22.3A, thermally protected system, LP side (PS 22.6 bar, TS max 50oC TS min-35oC, Vol 31.L) HP side (PS 28.5 bar, TS max 60oC TS min-35oC, Vol 1.2L), having lubricant P.O.E.160Z, crank case heater, suitable for R-404A refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing, vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified. Make- Danfoss commercial compressors Model No- NTZ215A4LR1A or equivalent. Note:- Refrigerant gas shall be measured and paid in respective item.
M&L for refrigerant gas R-404a including charging in compressors as per OEM specification.
M&L for replacement of Refrigerant drier filter as per existing model & type Make including brazing and making leak proof complete all as reqd at site & directed by Engr in Charge
Replacement of unserviceable HP / LP cut outs as per model & type including cutting, brazing complete as specified & directed by Engr in Charge
S&F in replacement of blower belt of AHU / Compressor belts as per existing model and type ISI marked including re-alignment of the motor and blower if required for proper tension of belts as directed by Engr-in-charge.
M&L for refrigerant gas R-22 including charging in compressors as per OEM specification. Make Floron,Freon or equivalent
M&L for refrigerant gas R-407C including charging in compressors as per OEM specification. Make Floron,Freon or equivalent
M&L for replacement of unserviceable heater strip type 2kW capacity as per existing size.
M&L for replacement of unserviceable heater strip type 3kW capacity as per existing size.
M&L for replacement of unserviceable scroll type compressor of package type ac plant of cap 5.5 TR capacity suitable for working on 3 phase, 50Hz, suitable for R-407c Refrigerant, having mineral lubricant oil, LRA-I Block 75.0,67-0-74-0 ,I opera Max 12.1, including crank case heater, cutting brazing to inlet out let refrigerant piping, nitrogen pressure test for leakage testing, vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified by OEM & directed by Engr in Charge. Make - Emersion Copeland Scroll Model No ZR72KCE-TFD-522 or equivalent in Danfoss Note:- Refrigerant gas shall be measured and paid in respective item.
M&L for replacement of unserviceable digital micro processor controller PCB complete suitable for Model No DPA661S Nominal Cap 16500Kcal/Hr 415V, 3 Phase, 50 Hz, Rated Amp 13. Make- Blue Star / Soft Hard or equivalent
M&L for replacement of unserviceable digital microprocessor controller micro PCB complete suitable for Package type AC plant model No DP11983R2A / DAP1983R-1 nominal capacity 49500 Kcal/Hr with contactor complete as specified by OEM & directed by Engr in Charge Make- Blue Star /Soft Hard or equivalent
M&L for replacement of crank case heater of scroll type compressor suitable for 5 to 18 TR capacity as per existing type capacity and model.
M&L for taking out existing unserviceable scroll compressor and replace with new compressor suitable for working on 380-415V 3 phase , 50Hz, LR 175A, Max Oper-35A, thermally protected system, LP side (PS 25 bar, TS max 63oC TS min-35oC, Vol 31.0L) HP side (PS 31.9 bar, TS max 150oC TS min-35oC, Vol 2.0LI), having lubricant Mineral Oil P.O.E.160PSZ , crank case heater, suitable for R-407C refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified. Make- Danfoss commercial compressors Model No- SZ185S4RC or equivalent. Note:- Refrigerant gas shall be measured and paid in respective item.
M&L for replacement of defective temp sensor of chiller line as per existing make & model complete all as specified & directed by Engr in Charge
M&L for replacement of defective temperature controller with sensor including making proper wiring & connections complete all as specified & directed by Engr in Charge. Make: Sub-zero, Honeywell, Schneider
M&L for replacement of defective humidity controller with sensor including making proper wiring & connections complete all as specified & directed by Engr in Charge. Make : Sub-zero, Honeywell, Schneider
Replacement of unserviceable flow switch of chiller & condenser line 63 to 200mm dia line , including making all control connections complete all as specified & directed by Engr in Charge. Make : Honeywell or its equivalent.
M&L for Servicing of outdoor (condenser) unit of air cooled central / Package type AC plant by cleaning of fins by water jet of suitable pressure or cleaning by using chemical if reqd, including combing of fins by using fins comb to making straight the fins, checking electrical wiring, servicing, oiling of condenser motor, etc. complete as specified and directed by Engr-in-charge.
M&L for Servicing of air cooled chiller central / Package type AC plant 22.7 TR through OEM service Engineer having min 5 yrs. experience by cleaning of fins by water jet of suitable pressure or cleaning by using chemical if reqd, including combing of fins by using fins comb to making straight the fins, checking all electrical & control wiring, servicing, oiling of condenser motor, etc. complete as specified by OEM and directed by Engr-in-charge. Make of installed plant- Blue Star
M&L for Servicing of air cooled central/ Package type AC plant 5.5 TR through OEM service Engineer having min 5 yrs. experience by cleaning of cooling coil by using chemical if reqd, including combing of fins by using fins comb to making straight the fins, checking all electrical & control wiring, servicing, oiling of blower motor, etc. complete as specified by OEM and directed by Engr-in-charge. Make of installed plant- Blue Star
M&L for replacement of unserviceable fan blade of outdoor condenser unit of air cooled package/ central type AC plant (5 to 7.5TR) as per existing make, model and type complete all as directed by Engr-in-charge.
M&L for replacement of unserviceable fan blade with motor of outdoor condenser unit of air cooled water chiller AC plant 22.7TR (Model XWC2S-026AR2 of Blue Star) as per existing make, model and type complete all as directed by Engr-in-charge.
M&L for replacement of unserviceable blower motor 3 Phase, 415 V, 50 HZ, 0.75 HP 1400 RPM, s1 duty, Frame-80 of air cooled AC plant (5.5 TR) as per existing make, model and type complete all as directed by Engr-in-charge.
M&L for replacement of unserviceable motor suitable for working on single phase, 230V,50 Hz 1/3HP, 920 RPM, thermally protected of out model No door condenser unit of air cooled package/ central type AC plant (5.5 TR) as per existing make, model and type complete all as directed by Engr-in-charge.
M&L for servicing of Main Electric Panel board / Control panel board of Central / Package type AC Plant by cleaning the panel with blower, replacement of unserviceable burnt wire, cables with existing size & length including proper numbering, replacement of u/s fuse link, lugs, washer, nuts, bolts, checking proper electrical connection, connectivity etc. & find out defective parts and making the panel functional by replacing the unserviceable item (taken as supply only) as directed by Engr-in-charge. Note: (i) Unserviceable parts as MCB, MCCB, contactor, relay, MPD, etc. will be measure and paid separately. (ii) Minor parts like thimbles, tags, nut, bolts, washers etc shall be deemed to be included in item rate.
Supply & fixing of the following for above items (Make- Hager/Legrand/C&S/L&T/Marlin Garlin)
MCB 6-32 Amp SP C series
MCB 6-32 Amp SPN C series
MCB TPN 40 to 63Amp C series
MCB TPN 10 to 32 Amp C series
Add on Auxiliary contact block (MNX A-2 /MNX A-1/TA1-DN22)
MCCB 200A 4 Pole DU series
MCCB 100A 3 Pole DU series
HRC fuse link RH type having breaking capacity 80 kA ( 2-32 amps)
HRC fuse link bottle/Din type having breaking capacity 80 kA (36 to 63 amps)
Fuse bases for HRC fuse up to 32 Amp
Contactor MNX9
Contactor MNX18
Contactor MNX25
Contactor MNX32
Thermal Over Load Relay (Auto / Manual reset) suitable for contractors (Relay range 2.5-t to 9-13 Amps )
Thermal Over Load Relay (Auto / Manual reset) suitable for contractors (Relay range 23-32 to 30-40 Amps )
PVC connector 15 to 60 Amps
Electronic Timers 110 / 240 / 360 / 415Volts 50 Hz for (3-10/ 9-30/36-120 Sec)
Single phase preventer suitable for 3 HP to 15 HP Monoblock pump sets (Make Minilic)
R / Y / Phase / On / Trip indicating lamps (as per colour code)
3 way valve controller current transformer 60 XA Make SS Enterprises or equivalent
Material and labour for taking out unserviceable burnt electric motor of (compressor / Monoblock pump set / Blower / condenser / cooling tower) and rewinding the same by removing the burn out copper coil cleaning the motor and winding with super enamel copper wire of same gauge & turns including varnishing, providing new insulation sheet, heating the winding including replacement of unserviceable both end bearings, bush of existing size etc reqd at site, refixing to its original place and testing after repair complete all as specified and directed by Engr in charge. for following capacity:- Note: Rates for transportation from site to workshop & return shall be deemed to be included in quoted rates.
Up to 2 HP single / three Phase
3 HP 3 phase
5 HP 3 phase
7.5 HP 3 phase
M&L for replacement of air filters of Package type AC plant of cap 5.5 TR as per existing size, model & filtration capacity complete all as specified and directed.
M&L for replacement of unserviceable flanged type EU-4 grade Filters, having aluminium MOC casing, HDPE+NW+HDPE Mesh filter media , filtration efficacy 90% down to 10 Micron, size 600x600x50mm, Air flow 1000CFM , complete all as specified and directed by Engr in Charge Make:- Spectrum Filtration / Dyna Filter Pvt Ltd/ United filters/National Filter
M&L for replacement of unserviceable flanged type EU-4 grade Filters, having aluminium MOC casing, HDPE+NW+HDPE Mesh filter media , filtration efficacy 90% down to 10 Micron, size 600x300x50mm, Air flow 1000CFM , complete all as specified and directed by Engr in Charge Make:- Spectrum Filtration / Dyna Filter Pvt Ltd/ United filters/National Filter
M&L for replacement of butter fly valve including taking out existing unserviceable butter fly valve and making good to the disturbed surface matching to existing specification (i.e. insulation of chiller / condenser pipe line) of following size. Make sant ,zoloto,kirloskar or equivalent
(a) 80 mm dia
(b) 100 mm dia
DHAKSHNA MOORTHY AND SON
Kathir Marketing Services
ISLAND SALES ENTERPRISES
MGP Enterprises
PTech Engineers
M/s Karbhagam Sales Agency
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .