Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹42.8 L
EMD Value
₹85,500
Closing Date
12 Dec 2022, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
SPECIAL REPAIRS TO 03 X TOILET BLOCKS CONTAINING 50 WCS INCL SEWAGE LINE AND SEPTIC TANK IN AREA OF AGE B/R-I UNDER GE GOLCONDA
2022_MES_566522_1
8641/E8
Limited
Civil Works
Item Rate
90 days
HYDERABAD
As Per Tender
6 documents required · 6 mandatory
₹500
GE GOLCONDA
₹85,500
Yes
14 Dec 2022
1 Dec 2022
14 Dec 2022
1 Dec 2022
12 Dec 2022
5 Dec 2022
Amount
Taking down chowkats or frames with shutters (without taking off shutter from the frames) n.exc. 1.5 sqm complete.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel moulded plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of 5mm thick plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed.
S&F 100 mm long aluminium butt hinges complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 125 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F in repairs Vitreous China squatting pan, "Orissa" pattern size 580 X 440 mm white, with intgrel footrest (excluding flushing cistern & flush pipe) including 110mm dia PVC SWR 'P' or 'S' trap including provision of cement concrete all as specified and directed.
S & F in repair vitreous china bowl urinal flat back, size of 465 x 355 x 265mm white (minimum) with grating and union for discharge pipe, excluding waste pipe but including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with screws, pointing around urinal back in cement complete all as specified and directed.
S&F in repair PVC valveless syphonic action type flushing cistern 10 lit capacity low level, white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe complete all as specified and directed.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repair 15 mm dia fancy type bib taps cast copper alloy chromium plated type screwed down, screwed for iron pipe or for brass ferrule complete all as specifie and diredted.
S&F in repairs 15 mm dia Brass Stop valves/angle cock chromium plated fancy type, screwed down, high pressure, with crutch or butterfly hadle, screwed both ends for iron pipe or for unions complete all as specified and directed.
Supply and lay CPVC pipes, Schedule SDR-11 & plain CPVC SDR 11 fittings for sizes (outer dia) 20 mm including all fittings and fixed with solvents as per manufacturers recommendations on the walls/ ceiling or laying in floors including taking down existing GI steel tubing complete all as specified and directed.
Supply and lay CPVC pipes, Schedule SDR-11 & plain CPVC SDR 11 fittings for sizes (outer dia) 25 mm including all fittings and fixed with solvents as per manufacturers recommendations on the walls/ ceiling or laying in floors including taking down existing GI steel tubing complete all as specified and directed.
Supply and lay CPVC pipes, Schedule SDR-11 & plain CPVC SDR 11 fittings for sizes (outer dia) 40 mm including all fittings and fixed with solvents as per manufacturers recommendations on the walls/ ceiling or laying in floors including taking down existing GI steel tubing complete all as specified and directed.
Supply and lay CPVC pipes, Schedule SDR-11 & plain CPVC SDR 11 fittings for sizes (outer dia) 50 mm including all fittings and fixed with solvents as per manufacturers recommendations on the walls/ ceiling or laying in floors including taking down existing GI steel tubing complete all as specified and directed.
Supply and Fix CPVC brass elbow for 20 mm outer dia pipe complete all as specied and directed.
Supply and Fix CPVC Male brass threaded adaptor for 50 mm outer dia size (MTA/MBTA) complete all as specied and directed.
Supply and Fix CPVC Tank Adaptor for 50 mm outer dia size complete all as specied and directed.
S&F 1000 Ltr capacity rotaional moulded polyethylene water storage tanks cylindrical vertical with closed top, hoisted and fixed in position all as specified including dismantling existing tank complete all as specified and directed.
S&F in repair PVC ball valve 25 mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed. (minimum weight 25 mm- 455 gms )
S & F PVC( SWR ) pipes 110mm dia single socketed, in any lenth with rubber ring joints as rainwater, soil waste and vent pipe fixed to wall or laid in trenches including taking down existing unserviciable pipe with fittings complete all as specified and directed.
S&F PVC (SWR) bends any radious 110 mm dia completee all as specified and directed.
S&F PVC (SWR) bends with access door any radius 110mm bore in repairs complete all as specified and directed.
S&F PVC (SWR) junction single (single T) equal or unequal with access door of bore 110mm complete all as specified and directed.
S&F PVC (SWR) junction double (double Y) equal or unequal with access door of bore 110mm complete all as specified and directed.
S&F PVC(SWR) vent cowl 110mm bore complete all as specified and directed.
S & F PVC ( SWR ) pipe 75mm dia, single socketed , in any lenth with rubber ring joints as rainwater, soil waste and vent pipe fixed to wall or laid in trenches including taking down existing unserviciable pipe with fittings complete all as specified and directed.
S&F PVC (SWR) floor trap 75mm dia outlet, plain with grating including jointing with solvent cement in repairs complete all as specified and directed.
S&F PVC (SWR) bends any radious 75 mm dia complete all as specified and directed.
S&F PVC (SWR) junction double (double Y) equal or unequal with access door of bore 75mm complete all as specified and directed.
S&F PVC (SWR) junction double (double T) equal or unequal with access door of bore 75mm complete all as specified and directed.
Demolition of brick work or stone masonry, built in cement mortar complete all as specified and directed.
M&L brick work with fly ash bricks built in CM 1:6 with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius complete all as specified and directed.
M&L for Brick work with fly ash bricks with sub class 'B' bricks straight or curved on plan exc 6 m mean radius in cement mortar 1:4 in half brick thick walls complete all as specified and directed.
Taking down cement plaster on brick wall/stone wall, ceiling etc, raking out joints, hacking for key & scrubbing with water complete all as specified and directed.
M&L Rendering 10mm thick in CM 1:6 on fair faces of brick surfaces of walls finishing the surface even & smooth without using extra cement complete all as specified and directed.
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick surfaces of walls finishing the surface fair and even complete all as specified and directed.
M&L Rendering 5 mm thick in CM 1:3 on fair faces of ceiling finishing the surface fair and even complete all as specified and directed.
M&L for Preparing newly plastered surfaces and applying three coats of white wash on walls complete and all as specified and directed.
M&L for Preparing old plastered wall surfaces and applying One coat of white wash on walls complete and all as specified and directed.
M&L for preparation of newly plastered surfaces and applying Two coats of Cement base paint on walls complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of Old plastered surfaces and applying One coat of Cement base paint on walls complete all as specified and directed.
M&L for praparation of newly plastered surfaces and applying Three coats of White wash on ceiling complete all as specified and directed.
M&L for praparation of old plastered surfaces and applying One coat of White wash on Ceiling complete all as specified and directed.
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n exc. 15cm thick.(Below or above ground level).
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L for non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, over and including 15mm thick cement screed in CM 1:6 and levelling course of PCC 1:2:4 type Bo (using 12.5mm stone aggregate), tiles jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L glazed ceramic tiles 300mmx200mmx7mm thick in vetical surfaces laid over and including 10mm thick back coat in CM 1:4, tiles set and joint in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick with grey cement and pigment, machine pressed, set jointed and pointed in neat cement slurry as in floors laid over and including 15 mm thick screed bed layer in CM 1:6 complete all as specified and directed.
M & L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L 75 mm thick PCC 1:4:8 Type D2 (using 40 mm graded stone aggregate) in sub base of floor complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) 75mm thick as in plinth protection complete all as specified and directed.
M & L Taking down existing roof treatment felt, plaster including preparation of the surfaces of roof by cleaning of foreign materials with water, roughening surfaces of old concrete and washing down with water to remove dust, brushing neat cement slurry with 3 kg cement per square meter, rendering 10mm thick on concrete surfaces in CM 1:4 mixed with water proofing compound and finished even and smooth without using extra cement including laying APP based polymeric membrane minimum weight 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/Sqm) over primed surface with bituminous primer conforming to IS-3384 applied @ 0.3 Ltrs/Sqm by forced application and applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm finised with one coat of aluminium paint @ 100ml/Sqm, 10cm overlap fused uniformly by LPG torched flame complete all as specified and directed. Note: 1) Water proofing compound shall be measured and paid separately. 2) Padding concrete where required shall be measured and paid separately.
M&L for providing cement concrete type Bo 1:2:4 (12.5mm graded stone aggregate) as in padding mixed with IWPC (IWPC measured and paid seperately) complete all as specified and directed.
Supply only integral water proofing compound.
S&F 125mm dia brass chromium plated shower rose with or without swivel joints including fixing to steel pipe or union complete all as specified and directed.
S & F for Aluminium plate type 2, Gate and shutter, hooks and eyes 150 mm complete all as spfd and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames) exc. 1.5 sqm but n exc 4.00 each complete all as specified and directed.
Taking down shutters of any description n. exc. 1 Sqm each complete all as specified and directed.
M&L 2nd class hard wood plain straight solid chowkats and frames wrought, framed, rounded, chamfered put together with glue pinned joints and making good the surfaces complete all as specified and directed.
S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts of size 25x3MM MS flat; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 410-0 or Fe 310-0
M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in bed block for hold fasts, coping and benching of manhole including necessary form work weathering slighly rounded or chamfered angles and treating and making good the disturbed portion complete all as specified and directed.
M&L 2nd class hard wood plain framed factory made panel shutter 35 mm thick (two or three panels) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces, the size of rail & style as per IS 1003 (Part-I) Kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F 30 mm thick 2nd class hard wood factory made glazed and skeleton shutters for windows divided into square, with plain chamfered or rounded metred and rebital sash bar any number and framing moulded windows, ventilators, etc. provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.20 (b) fitted to chowkats complete all as specified and directed.
S & F MS Butt hinges medium weight cold rolled of size 100mm complete all as specified and directed.
S & F MS Butt hinges medium weight cold rolled of size 75mm complete all as specified and directed.
M & L preparation of surfaces of wood based material any description over 10 cm in width or girth applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L preparation of old surfaces of wood based material any description over 10 cm in width or girth and applying one coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S & F Aluminium anodised barrel tower bolts of extruded section and fixed, length of bolt in 200 mm complete all as specified and directed.
S & F Extruded aluminium alloy handles, fabricated type, anodised, Size of handle in 100 mm complete all as specified and directed.
S & F for Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt in 300 mm complete all as specified and directed.
S & F 3mm thick figured glass, pin head type and glazing with wooden beads or oil putty in square not exc. 0.50 Sqm in each pane complete all as specified and directed.
S&F 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F in repairs concealed stop cock fancy type 15mm dia, chromium plated with long shank and cup complete all as specified and directed.
S&F in repair vitreous china wash basin, white, flat back size 550 x 400mm including 01 Nos cast copper alloy 15mm CP pillar tap, 01 Nos 32mm waste coupling and pipe, one pair of MS bracket, cutting for and pinning in ends of brackets complete all as specified and directed.
M&L walling random rubble, uncoursed, will bonded, bedded and solidly hearted built in CM 1:6 Secunderabad type complete all as specified and directed.
M&L flush pointing to random rubble mansonry, uncoursed or brought upto courses in Cement Mortar 1:3 complete all as specified and directed.
M&L PCC (1:4:8) type D2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for salt glazed stoneware drain pipes 150mm dia bore (Grade 'A' pipe) laid in trenches and jointed as specified including demolition and breaking of existing same bore drain pipe complete all as specified and directed.
M&L for salt glazed stoneware drain pipes 200mm dia bore (Grade 'A' pipe) laid in trenches and jointed as specified including demolition and breaking of existing same bore drain pipe complete all as specified and directed.
M&L for concrete bed to drain pipes 150mm dia bore using plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested in complete all as specified and directed.
M&L for concrete bed to drain pipes 200mm dia bore using plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested in complete all as specified and directed.
M&L for RCC 1:2:4 type B1 using 20mm graded stone aggregate as in Pre-cast cover slabs for mahnoles, precast lintels set in CM 1:4 including necessary from work including demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed (Reincorcement will be measured & paid separately)
M&L TMT bars, 10mm dia & over, cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire complete all as specified and directed.
M&L TMT bars, 6 to 8 mm dia cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire complete all as specified and directed.
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick wall surfaces, finishing the surface fair and even complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide & n.exc 1.5m depth for foundaton etc or for laying cable/pipes, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in hard and dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 250m and depositing where directed at a level n exc. 1.5m above the starting point in soils complete all as specified and directed.
Supply & fixing galvanized steel water tubing medium grade with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc of size 50mm dia including taking up or down existing 50mm dia steel tubing including connections complete all as specified and directed.
Supply & fixing galvanized steel water tubing medium grade with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc of size 40mm dia including taking up or down existing 40mm dia steel tubing including connections complete all as specified and directed.
Supply & fixing galvanized steel water tubing medium grade with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc of size 25mm dia including taking up or down existing 25mm dia steel tubing including connections complete all as specified and directed.
Supply & fixing gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe pipe of size 50 mm including taking down old unserviceable complete all as specified and directed.
Supply & fixing gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe pipe of size 40 mm including taking down old unserviceable complete all as specified and directed.
Supply & fixing gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe pipe of size 25 mm including taking down old unserviceable complete all as specified and directed.
Cutting existing steel tubing of size 50mm/40mm dia for alterations or additions (Each cut measured)
Screwing existing steel tubing of size 40mm/50mm dia for alterations or additions (or lengthening screw on pipe to form connector)
Construction of valve chamber with PCC 1:4:8 type D2 for foundation, brick wall in cement mortar (1:4), PCC 1:2:4 type B1 for coping, rendering in CM (1:4) 15mm thick for internal surfaces including coping concrete, MS cover made out of 3mm thick sheet fixed in angle iron frame 40x4045, fixed with hinges welded to MS frame made out of angle iron 40x4045mm fixed in coping and applying two coats of synthetic enamel paint over a coat of redoxide primer including necessary excavation earth work in any type of soil of size 600x600x600mm depth complete.
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 4 Core complete all as specified and directed.
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 2 Core complete all as specified and directed.
Supply and spread approved dry river sand for cable cushioning laid in trenches including watering and consolidation complete all as all as specified and directed. Note:- Punned thickness shall be measured and paid.
M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 115 x 75mm for cable protection complete all as specified and directed.
Supply and Fix Tubes, 'light grade' galvanised, with all fitting, fixed complete to walls and ceilings or laid in floors of size 25mm dia complete all as specified and directed.
Supply and Fix Tubes, 'light grade' galvanised, with all fitting, fixed complete to walls and ceilings or laid in floors of size 40mm dia complete all as specified and directed.
Supply, installation, test and commissioning CPRI APPROVED factory fabricated, outdoor type, LT Feeder Piller Box made out of 3.15mm thick CRCA sheet of size 1M x 0.75M x 0.35M with projected globe roof for rainwater protection dust and vermin proof, double door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 Wire System, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc cromium plated nuts, bolts and washers etc. and embeded with 50x50x6mm mild steel angle iron frame 600mm above the normal ground level complete with internal connection with suitable size of cable, cable lugs and cable glands, PCC foundation in cement concrete 1:3:6 (20mm graded stone aggregate) and testing after installation complete all as specified and comprising of the following :- (a) Aluminium busbar 200 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 63 Amps, 415 volt, 16 KA breaking capacity 4 pole electromagnetic release duly connected to busbar as incoming - 01 No.
M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32mm x 6mm dia by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point incl necessary earth work and excavation PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with SSR Part-II RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with water pipe GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia, light grade all as specified and directed in SSR Part II. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
Taking out carefully copper/aluminium point wiring, Light, fan, socket or power complete with all fitting, fixtures such as switch socket out let, ceiling rose, holder, regulator, DBs etc including making good the disturbed surface of wall/floors complete all as specified and directed.
M&L Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 1.50 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable ( green colour) as earth lead in and including non metalic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for Surface wiring on stone/brick,masonary walls, roof etc including MS sunk box of required size & 2 mm thick plastic laminated sheet for housing switches sockets, regulators etc, including making good the disturbed surfaces to match with the existing specification, complete all as specified and directed at site.
All as per item no.110 but for One 5 pin 15 / 16 Amps switch socket outlet point on independent board with 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed.
Supply and fix switch piano flush type single pole one way 5 Amps complete all as specified and directed at site.
M&L Switch socket combination 2 in 1 flush type universal 3 pin 6 & 16 Amps flush type complete all as specified and directed at site.
Supply and fix Ceiling rose surface bakelite three 65x50 mm, terminals 240 volts complete all as specified and directed.
Supply and fix lamp holder insulated body with back plate suitable for battern fittings complete all as specified and directed.
Supply and fix 9/10 watt LED Bulb complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED street light fitting 35/36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fix Sheet metal enclosure IP-43 double door for DBs(where MCBs are reqd) SPN 240 V, for 8 ways complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 AMP, in the MCB DB including connection, testing and commissioning complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SP and current carrying capacity 6- 32 AMP, in the MCB DB including connection testing and commissioning complete all as specified and directed.
Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and testing on completion.
Supply and laying Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire
Sri Lakshmi Enterprises
COMBINE CONSTRUCTION
RAFEEQ AND CO
STANDARD AGENCIES
M/S Veerabhadra Constructions
NAVANAND ENTERPRISES
BUILDWEL
GNV Engg Services
UNITED TECHNO PROJECTS PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .