Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹23.8 L+₹35,152 (1.50%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹25.9 L+₹2.5 L (10.5%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹26.6 L+₹3.2 L (13.6%)Rejected-Finance R O RAWALPORA WANBAL YAIYAL TEH DISTT SRINAGAR J K PIN 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹29.2 L+₹5.8 L (24.8%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
18 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE970EWS C/O56APO PIN 913970
REPAIR AND MAINT OF EM INSTALLATION BLDS BY NATURE OF BR AND ELECTRICAL WORKS AT OAF UNDER GE 970 EWS
2021_MES_444036_1
GE970EWS-10/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE970EWS
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE970EWS
₹60,000
Yes
3 Feb 2022
19 May 2021
21 Jun 2021
19 May 2021
18 Jun 2021
4 Jun 2021
60 days
Amount
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick in ridges of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screwscomplete all as specified and directed
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws complete all as specified and directed
Plain, galvanised, 0.63 mm thick mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed
All as per item No 04 but except sheeting (any thickness) complete all as specified and directed
0.63 mm thick galvanized, corrugated mild steel sheeting with grade of zinc coating 275 with two corrugation side lap, fixed with 'L' or 'J' type or crancked hook bolts and washers in roofs, walls etc complete all as specified and directed
All as per item No 06 but except sheeting (any thickness) complete all as specified and directed
Preparation of new or previously untreated steel surfaces over 10 cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Preperation of old decorated steel surface (Corrugated or semi corrugated) roof of any description by brooming down, blowing by blower lamp and washing with water and removal of rubbish from roof surface and applying one coat of synthatic enamel paint of approved colour and pattern complete all as specified and directed
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed
S&F angle iron and flat iron as in post and struds in fencing including cutting tops to shape as directed drilling holes notching for wire etc, flat iron fillets (for securing necessary drilling bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed
PCC 1:4:8 type D2 using 40mm graded crushed stone aggregates as in foundation filling and mass concrete in foundation concrete of fencing posts complete all as specified and directed
PCC 1:2:4 type B2 using 40mm graded crushed stone aggregates as in foundation filling and mass concrete in foundation concrete of fencing posts complete all as specified and directed
Supply only chain link MS galvanised fencing any size or type complete all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire etc complete all as specified and directed
S&F mild steel bolts machine made with hexagonal or square head one end and screwed the other or screwed both ends each screw end to be fitted with washer and one hexagonal or square not nexc 5cm long, dia of neak 5 to 10mm complete all as specified and directed.
Supply and fixing in repair Steel rolling shutters, 1.25mm lath, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
Supply and fixing in repair Ball bearing for rolling shutters complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness below or above ground level complete all as specified and directed
25 mm thick PCC 1:2:4, type B-0 using 12.50 mm graded crushed stone aggregates as in sub floor surfaces, complete all as specified and directed.
Non skid ceramic tiles coloured pattern as required of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the existing, over with and including 15mm thick screed bed in CM (1:4) after dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Non skid ceramic tiles coloured pattern as required of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the existing, over with and including 15mm thick screed bed in CM (1:4) after dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Glazed ceramic tiles coloured pattern as required 300 x 200 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match the existing, over with after including 10mm thick backing coat in CM 1:4 and incl dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Demolition brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed
Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed
All as per item No 25 above but except bricks complete all as specified and directed
Taking down cement plaster from brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
Rendering 15mm thick in cement mortar 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed
Preparation of old plastered surfaces of wall and applying one coat of oil bound distemper complete all as specified and directed
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
Preparation of newly plastered surface of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed
Preparation of old plastered surfaces of wall and applying one coat of cement base paint complete all as specified and directed
Taking down Shutters of any description not exc 1.0 sqm each complete all as specified and directed
Factory made 2nd class hard wood 30 mm thick glazed and gauzed skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed
Taking down Shutters of any description exc 1.0 sqm and n.exc 2 sqm each complete all as specified and directed
Taking down chowkats or frames exc 1.5 sqm but n.exc 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed
2nd class hardwood plain solid, straight chowkat and frame, wrought, framed rebated (one or more rebated) on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
Factory made 2nd class hard wood 35mm thick plain framed panelled shutter with lock rail and panel of 9 mm BWP commercial ply or 12 mm to 15mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part - I) kiln seasoned and chemically pressure treated complete all as specified and directed
Factory made 2nd class hard wood 35 mm thick glazed and gauzed skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed
Taking down chowkats or frames not exc 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed
Solid PVC door frame of size 50mm x47mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube, supplying and fixing in opening, edges will be painted to match with printed sheet complete all as specified and directed
Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded prelaminated PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, in frame at site as per specification & drawing complete all as specified and directed
Galvanized mild steel wire cloth, 0.56 mm nominal dia or wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staple complete all as specified and directed
Supply and fixing in repair galvanized mild steel wire cloth, 0.56 mm nominal dia or wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staple complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed
3mm thick sheet glass, ordinary quality glazing with oil putty in square n exc 0.50 sqm in each pane complete all as specified and directed
250mm long, Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
Extruded aluminium alloy handles, fabricated type, anodised of 150mm size complete all as specified and directed
200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed
100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed
Butt hinges medium weight cold rolled mild steel 100mm size complete all as specified and directed
Butt hinges medium weight cold rolled mild steel 75mm size complete all as specified and directed
Preparing surfaces of new wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Preparing surfaces of old wood and wood based material of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
Dismantling timber scantlings 40 sq. cm and over in section, in any position framed work complete all as directed
Clean swan 2nd class hard wood timber scantling any position complete all as specified and directed
Supply & fixing in repair suspended false celling system using E Grid suspended celling Grid system. The size of Grid shall be 600X600mm with GI frame work, main runner 39X24mm, cross tee 29X24mm and wall angle 22.2X22.2mm including 4mm thick High Pressure Stream cured non primered classic/designer variant E-Board ISI Marked, IS No 14862-2000. Fibre cement E Board to be placed in the gird of E Grid suspended ceiling grid system duly suspended by 4mm dia GI bar hangers from the purlins of the roof complete all as specified and directed
Machine cut kota stone 18 to 20 mm thick in flooring laid over and incl 20 mm thick screed bed or bedding layer of morter and jointed in grey cement slurry mixed with pigment to match the slab including rubbing and polishing complete all as specified and directed
Factory made Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment, incl sand cushioning 25 mm thick below paver block complete all as specified & directed
75mm thick PCC 1:4:8 type D2 using 40mm graded crushed stone aggregates as in sub base, floors etc complete all as specified & directed
50 mm thick PCC 1:3:6, type C-1, using 20 mm graded aggregates as in plinth protection etc, finished even and smooth without using extra cement complete all as specified and directed
S & F in repair vitreous china urinals bowl type flat back, size 465 x 355 x 265 mm, white , complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and union for discharge pipe complete all as specified and directed
S & F in repair vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rest including trap, flushing pipe and anti-syphonage pipe complete all as specified and directed
S & F in repair PVC valveless, syphonic action, flushing cistern 10 ltr capacity, low level, white, with inlet ball valve, float and handle including brackets complete all as specified and directed
S & F in repair Low density PVC connection commercial quality 450mm long including PTMT nuts at both sides of 15mm bore and fixed complete all as specified and directed
Taking up or down 15 mm bore steel tubing and connections including cleaning for refixing complete all as specified and directed
15mm bore steel tubing, medium grade, galvanised with all fittings and fixed complete fixed to wall and ceiling or laid in floors complete all as specified and directed
Refixing old 15 mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc) complete all as specified and directed
S & F in repair 15 mm bore CP bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed
S & F in repair 15 mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed
Supply, laying and testing of UG XLPE insulated, armoured heavy duty electric cable with aluminium conductor ISI marked as per IS-7098 (Part-I), 1100 Volts grade, cross-sectional area 50 sqmm 4 Core laid in trenches/pipes, fixed to poles/walls with suitable saddle & glands incl taking out the old burnt out cable complete all as specified and directed (Note :- Excavation, earth work, sand cushioning & brick protection shall be measured and paid separately)
All as per item No. 72 above but 16 Sqmm 4 core.
All as per item No. 72 above but 10 Sqmm 4 core.
All as per item No. 72 above but 10 Sqmm 2 core.
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable & electrical poles etc. complete all as specified and directed.
Excavation in trenches exc 1.5 M wide and exc 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable & electrical poles etc. complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing surplus soil to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
Supply and laying dry river sand to be laid in 8 cm before laying of cable and 15 cm above cable in trenche as cable cushioning and covering complete all as specified and directed. Note: for payment purpose punned thickness shall be measured
Brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed.
Supply and Fix in repair for street light fitting bracket made out of 32/40mm bore GI pipe, light grade, bend to shape, 1.2 metre long, fixed to pole/wall with and including two sets of clamps made out of flat iron of size 50 x 6 mm with bolts, nuts and washers, complete all connected accesories for fixing of GI bracket with pole including one coat of anti corrosive primer and two coats of aluminium paint complete all as specified and directed.
S & F in repair for Junction Box of size 200mmx150mmx100mm, made out of 1.6mm thick MS sheet front openable, incl two coats of synthetic enamel paint over coat of red oxide primer for cable entry of size 10 to 25 sq mm, 2 core including fastening clamp with LT pole, box hinged cover with locking arrangements including with terminals TPN strip, with 01 No MCB SP 6A 'B' Serials complete all as specified and directed. Make: HENSEL or its equivalent as approved by GE.
Supply and Fix in repair Energy efficient LED street Light Luminaire 70 watts capacity comprises a die-cast aluminium housing IP-65 Bow with front toughened glass cover suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories and 2 core copper connecting cable of size 2.5 sqmm from junction box to light fitting (Approx 5 Mtr) complete and fixed on existing pole bracket complete all as specified and directed. Make : Cat Part No.ENXT P 84L WH CR PC SD of bajaj or equivalent in approved makes.
Supply and Fix in repair Energy efficient LED street Light Luminaire 60 watts capacity comprises a die-cast aluminium housing IP-65 Bow with front toughened glass cover suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories and 2 core copper connecting cable of size 2.5 sqmm from junction box to light fitting (Approx 5 Mtr) complete and fixed on existing pole bracket complete all as specified and directed. Make : Cat Part No. ENXT P 72L WH CR PC SD of bajaj or equivalent in approved makes.
Supply and Fix in repair Energy efficient LED street Light Luminaire 45 watts capacity comprises a die-cast aluminium housing IP-66 45 W with front toughened glass cover suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories and 2 core copper connecting cable of size 2.5 sqmm from junction box to light fitting (Approx 5 Mtr) complete and fixed on existing pole bracket complete all as specified and directed. Make : Cat Part No. ENXT P 54L WH CR PC SD of bajaj or its equivalent make of Philips /CG/wipro .
Supply and Fix in repair LED flood Light 250 watts capacity with secondary optics made in pressure die-cast aluminium housing IP-66 protection fixed or mounting on AOL bracket of high mast light complete with all accessories and 2 core copper connecting cable of size 2.5 sqmm from junction box to light fitting (Approx 5 Mtr) complete all as specified and directed. Make : Cat Part BJFL 250W LED WH MB of bajaj or its equivalent make of Philips /CG/wipro .
Supply and Fix in repair LED flood Light 240 watts capacity with secondary optics made in pressure die-cast aluminium housing IP-66 protection fixed or mounting on AOL bracket of high mast light complete with all accessories and 2 core copper connecting cable of size 2.5 sqmm from junction box to light fitting (Approx 5 Mtr) complete all as specified and directed. Make : Cat Part BJFL 240W LED WH MB of bajaj or its equivalent make of Philips /CG/wipro .
Supply and fix in repair of MS Cross arm, bracings, supports , clamps and back plate fabricated from structural steel section, including nut , bolts , washers, welding , bendings cold or hot, drilling hole for both in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat of paint complete all as specified and directed
Supply and fix in repair galvanised iron tubes 50mm bore, light grade including all fittings fixed to wall, ceilings and or laid in floors/tenches/under road etc complete for cable protection all as specified and directed.
Supply and fix in repair galvanised iron tubes 80mm bore, light grade including all fittings fixed to wall, ceilings and or laid in floors/tenches/under road etc complete for cable protection all as specified and directed.
Material and labour for sub main wiring with two runs of single core PVC insulated (FRLSH) unsheathed copper conductor multistranded cable of size 2.5 sqmm 1100 volts grade drawn through in & including PVC conduit/casing caping of suitable size & 1.5 sqmm single core copper conductor multistranded PVC insulated (FRLSH) unsheathed cable earth wire continuity conductor fixed on pole for connection from junction box to light fittings / switch to top of the Over Head Water tank of height not more than 30 mtr from ground level including taking down old complete all as directed Note : (i) Two run of cable 2.5 sqmm and one run of 1.5 sqmm earth wire and one run of PVC casing caping/PVC conduit shall be measured and paid as one unit only. (ii)Phase should be Red / Yellow / Blue, neutral should be black and earthing wire should be green in colour
Taking down of steel tubular pole and re-fixing the same from one location to another location (not more than 500m) incl shifting of conductor and insulator and incl two coats of aluminium paint on pole with marking pole number complete all as specified and directed (Note - PCC will be measured and paid separately)
PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation complete all as specified and directed
Removing vegetation, grass, scrubs and bushes or any small tree branches growing in sub station yard along with fencing, around the pole under the LT transmission lines and keep the yard neat and clean complete all as specified and directed.
M/S MIR SAJAD ENTERPRISES
M/S GHULAM HASSAN KUCHAY
M/S LATIF AHMAD BABA CONSTRUCTION
NAJAR ENTERPRISES
M/S M.Y Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .