| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC V P O GUNJAR 125006 | GUNJAR | GURUGRAM | HARYANA | 125006 | L1 | Accepted-AOC ok | |
| 2 | L2₹17.6 L+₹1.7 L (10.4%)Rejected-Finance | L2 | Rejected-Finance Not responsive | |
| 3 | L3₹18.1 L+₹2.1 L (13.4%)Rejected-Finance | L3 | Rejected-Finance Not responsive | |
| 4 | L4₹18.9 L+₹3.0 L (18.7%)Rejected-Finance | L4 | Rejected-Finance Not responsive | |
| 5 | L5₹19.5 L+₹3.6 L (22.3%)Rejected-Finance | L5 | Rejected-Finance Not responsive |
Tender Value
₹15.5 L
EMD Value
₹31,000
Closing Date
7 Dec 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
CCS HAU, Hisar
Construction of ramp in Building of College of Home Science at CCS HAU, Hisar. (including EI work)
2020_HRY_150940_1
3183-C
Open Tender
Civil Works
Works
120 days
CCS HAU HISAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹31,000
13 Jan 2021
18 Nov 2020
9 Dec 2020
19 Nov 2020
7 Dec 2020
19 Nov 2020
120 days
Amount
Civil work 1 to 23:- Earth work excavation in ordinary soil exclusive of compensation of earth- b. earth-work undressed with a combined lead upto 15 metres including breaking of clods (HSR 6.2 (b)
Dressing of Earthwork:- (i) New work or remodeling work (HSR 6.3 (i)
Earth filling under floors with surplus soil, excavated from foundation and taken only from outside the building plinth, in 15 cm layers, including ramming watering and consolidating lead upto 30 metres {HSR 6.13(a)}
Cement concrete 1:8:16 with stone aggregate 40 mm nominal size in foundation and plinth.(HSR 10.28)
Cement concrete 1:2:4 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement , but including centring and shuttering, laid in position , complete in all respects (HSR 10.82) First storey
Cement concrete 1:2:4 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement , but including centring and shuttering, laid in position , complete in all respects (HSR 10.82+ note) Second storey
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns,(square or rectangular) battens and lintels etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects (HSR 10.86} First storey
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns,(square or rectangular) battens and lintels etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects (HSR 10.86+note} Second storey
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in fascias parapets and other thin vertical sections, not covered by item nos. 10.82,10.86 to 10.88 not exceeding 10 cm thickness excluding steel reinforcement but including centring and shuttering , laid in position, complete in all respects. (HSR 10.89) First storey
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in fascias parapets and other thin vertical sections, not covered by item nos. 10.82,10.86 to 10.88 not exceeding 10 cm thickness excluding steel reinforcement but including centring and shuttering , laid in position, complete in all respects. (HSR 10.89+ note) Second storey
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects,(For work upto 1.5 metres below ground level). (HSR 10.90)
Extra over item Nos. 10.79 to 10.94 , if 1:1.5:3 mix is used, instead of 1:2:4 {HSR 10.95(a)}
Providing and fixing factory manufactured jali of reinforced cement concrete consisting of cement, coarse sand and 10 mm and down gauge bajri in the ratio of 1:1:2 with 8 mm dia for steel. Outer frame of the jali will be 50 mm wide and 25 mm thick and inner frame of jali will be 25 mm wide and 25 mm thick with smooth finish as per design approved by the Engineer In charge including fixing in position upto any height with cement sand mortar 1:4 complete in all respect. (HSR 11.103)
Pre cast chequered tiles of 20 mm thickness in ordinary grey cement without chips laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors ,treads of steps and landings (HSR 14.45) First storey
Pre cast chequered tiles of 20 mm thickness in ordinary grey cement without chips laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors ,treads of steps and landings (HSR 14.45+ note) Second storey
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade (HSR 16.3)
Applying priming coat with metal primer on new steel or iron work including preparation of surface (HSR 16.9)
Preparation of plastered surfaces for oil bound distemper including sand papering the surface, applying one coat of linseed oil, and filling with approved quality filler, consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to the required finish complete (HSR16.52)
Distempering with washable oil bound distemper (of approved manufacture) two coasts excluding priming coat on new work (HSR 16.57)
Providing and applying two coats of white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc., complete (J.K/ Birla make). (HSR 16.81)
Wrought iron and mild steel (using angles, flats square bars. tees and channels) ladders, grills, gratting frames, window guards, iron door openable or fixed stair case or parapet or any other type of railing , gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position (HSR 18.12)
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC incluidng straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position, complete in all respect for all heights/depths/storeys/basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separtely for different diameters as actually used in work excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22)
Providing and fixing IRC fabric of size 75 X 75 mm, made of 3.15 mm diameter wire, in steel frame with 3 mm thick MS flat iron cover moulding of 12.5 mm width fixed with machine screws, welded, complete in all respects as per architectural drawing & design., complete. (excluding cost of steel frame and MS flat.) (NS)
Electrical work 24 to 29:- MINIATURE CIRCUIT BREAKER AND ISOLATOR:(HSR 31.17 (a) (ii) Supply and erection of miniature circuit breaker/isolator 240/415 V in the existing distribution board including making necessary connections (a) Miniature Circuit Breakers of 9 K.A. breaking capacity (ii)6-32 amp. SP MCB
S/E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size excluding cost and erection of pipe {HSR 31.40 (i)} (i) Size 1.5 sqmm(3/0.81mm)
S/E of PVC conduit pipe ISI marked (Medium) recessed in wall/ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work {HSR 31.44 (b) (b) 25mm dia
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 31.56) 10 amp. 1 way switch
Pdg. and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. (HSR 31.57) 6 Modules
S/E of surface/wall mounted ≤20W integrated LED 4 feet fitting with Epoxy Powder coated white/Grey extruded aluminium channel housing for efficient heat dissipation. Total system lumen of 20 watt LED should be ≥ 2000 or above in cool day light (5700K to 6500K), Power factor >0.95, CRI >80, Average life >50000 hours. Complete with mounting Brackets & accessories as required with connections(Industrial) Make: Philips, Havells, Wipro, Bajaj. (NS)
M/s sukhdev and company
JAGAT SINGH CONTRACTOR
M/s BG Construction Co
Shri Balaji Construction
RAJESH KUMAR CONT
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .