Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹23.7 L+₹4.9 L (26.1%)Rejected-AOC | L2 | Rejected-AOC AS PER BOQ | |
| 3 | L3₹24.4 L+₹5.6 L (30.0%)Rejected-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC AS PER BOQ | |
| 4 | L4₹24.8 L+₹6.0 L (31.9%)Rejected-AOC | L4 | Rejected-AOC AS PER BOQ | |
| 5 | L5₹26.3 L+₹7.5 L (40.0%)Rejected-AOC CHHURTA JHAJJAR KOTLI JAMMU J K 181222 | 181222 | L5 | Rejected-AOC AS PER BOQ |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
5 Oct 2021, 6:00 pmClosed
GE Army Dhar Road Udhampur
GE Army Dhar Road Udhampur
REPAIR, MAINT /REPLACEMENT OF STREET LIGHTS/ SECURITY LIGHTS, HIGH MAST LIGHTS, FLOOD LIGHTS, POST TOP LANTERN, REPAIR AND MAINT OF LIGHTENING CONDUCTOR AND ALLIED CONNECTED WORKS AT JINDRAH UNDER GE(ARMY) DHAR ROAD
2021_MES_473529_1
8067/NIT-45/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
Jindrah under GE (Army) Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road Udhampur
₹64,000
Yes
5 Nov 2021
7 Sept 2021
7 Oct 2021
7 Sept 2021
5 Oct 2021
19 Sept 2021
7 Sept 2021 - 18 Sept 2021
Amount
M&L earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to GI strip 32 x 6 mm as earth continuity conductor including 40 mm bore pipe light grade for protection of strip by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel connected to earth test point upto 7.5 mtr away from earth electrode all as per plate No 03 of SSR-I including necessary earth work, PCC 1:3:6 type C1 chamber, RCC cover slab of 50 mm thickness 1:2:4 with 8mm dia CTD bars 140 mm C/C as reinforcement with suitable handle, watering pipe 20 mm dia light grade with funnel, charcoal salt and testing on completion including taking down old unserviceable earthing with connected items all as specified and directed by Engr in Charge.
S&F in replacement air termination single pointed aluminium rod 12 mm dia and 300 mm long fitted on exisiting lightening conductor tube 40 mm on buildings with FI clamps, nuts and bolts complete all as specified and directed.
S&F in replacement earth test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25 mm , drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws grouted on wall with PCC, nuts, bolts and washers, including making good to disturbed surface complete all as specified and directed.
S&F in replacement Galvanised iron strip 32 x 6 mm for extension of earth lead and connected properly to equipment or panel with proper clamps, saddles, nuts, bolts and washers etc complete all as specified and as directed .
S&F in replacement aluminium strip 25 x 3.15 mm with saddles and fixing screws, gutties etc on wall and roof top conductors including grouting wooden gutties complete all as specified and directed.
Dismanting and taking down of old damaged GI pipe holding air termination rod on roof top from the exiting PCC mounting and regrouting the same on roof after refixing the new/old air termination rod complete all as specified and directed. Note PCC and air termination rod will be measured and paid seperately under respective items of BOQ.
Taking out old damaged GI strip and aluminium strip (damaged by Monkey ) from roof, wall complete including straightening the strip and refixing in the same position with saddles, fixing screws, gutties etc on wall and roof top conductors including grouting wooden gutties complete all as specified and directed.
S&F GI tubing light grade 40 mm bore fixing in bricks/stone wall with 2 Nos supporting clamps made of flat iron of size 25 x 4 mm including nuts, bolts and grouting bolts complete all as specified and directed for fixing lightening arrester on roof top.
S&F GI tubing light grade 40 mm bore including grouting in PCC complete all as specified and directed for fixing leghtening arrester on roof top. Note PCC will be measured and paid seperately under respective item of BOQ.
Dismantling taking down existing unserviceable flood/street/post top lantern/gate light fitting any type any capacity from Pole/Building for replacement complete all as specified and directed.
Supply, fixing, connecting, testing and commissioning LED flood light fittings 120 watt ,240 volt, 0.57 Amp current, > 0.95 PF, 5700 K Temp ,new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver. Make Crompton cat part No TFS-504-120-57-60D-SL-GL-NSG or equivalent in Havells, Philips & Wipro as approved by GE. Note : (i) A certificate of Gurrantee shall be submitted by the contractor for period 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp & light fittings to GE. Performance guarantee amount @ 5% of quoted amount of LED lamps & light fitting shall be kept reserved for a period of three years. Atlernatively after completion of work contractor may furnish guarantee amount in the shape of FDR/BGB pledged in favour of GE. (ii) Luminarie shall be provided with all parameters mentioned above.
Supply, fixing, connecting, testing and commissioning LED Street light fitting 70 Watt, 240 watt, 0.3 Amps, PF> 0.95, colour Temp 5700K new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver. Make Crompton cat part No TRP-409-70-57-SL-GL-NSG or equivalent in Havells, Philips & Wipro as approved by GE. Note : (i) A certificate of Gurrantee shall be submitted by the contractor for period 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp & light fittings to GE. Performance guarantee amount @ 5% of quoted amount of LED lamps & light fitting shall be kept reserved for a period of three years. Atlernatively after completion of work contractor may furnish guarantee amount in the shape of FDR/BGB pledged in favour of GE. (ii) Luminarie shall be provided with all parameters mentioned above.
Supply,fixing, connecting, testing and commissioning LED Street light fitting 90 Watt, 240 watt, 0.42 Amps, PF> 0.95, colour Temp 5700K new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver. Make Crompton cat part No CRP-411-90-57-SL-GL-NSG or equivalent in Havells, Philips & Wipro as approved by GE. Note : (i) A certificate of Gurrantee shall be submitted by the contractor for period 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp & light fittings to GE. Performance guarantee amount @ 5% of quoted amount of LED lamps & light fitting shall be kept reserved for a period of three years. Atlernatively after completion of work contractor may furnish guarantee amount in the shape of FDR/BGB pledged in favour of GE. (ii) Luminarie shall be provided with all parameters mentioned above.
S&F Post top energy saving , environmental friendly, aesthetically designed with indirect symmetrical light distribution die-cast aluminium IP-65 luminaire with high power COB LED as light source of capacity 40/35 Watt, 6500K all as specified and directed. LPTC-40-CDL or equivalent in Havells, Philips & Wipro as approved by GE. Note : (i) A certificate of Gurrantee shall be submitted by the contractor for period 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp & light fittings to GE. Performance guarantee amount @ 5% of quoted amount of LED lamps & light fitting shall be kept reserved for a period of three years. Atlernatively after completion of work contractror may furnished guarantee amount in the shape of FDR/BGB pleased in favour of GE. (ii) Luminarie shall be provided with all parameters mentioned above.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in hard/dense soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Taking out existing worn out/old PVC insulated cable in 3 core of 95 Sqmm size of 11000 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete in all respect and as directed at site.
Supply & laying HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 11 KV cross sectional area 95 Sqmm 3 Core (Earthed)conforming to IS 7098 lead in duct/trenches complete all as specified and directed Make of Cable:Havells, Polycab, Gloster,Finolex
S&F Street light junction box of size 200mm x 140mm x 95mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable/wire complete comprising with the followings incl dismentling taking down unsv complete all as specified and directed. :- (a) Bus bar with two aluminium strips, 63 Amps capacity insulated with insulators, including colour coding, including PVC cable of suitable size from bus bar to MCB (b) MCB SPN 5 to 30 Amps - 01 No (c) Clamps made out of 25mm x 3mm flat iron duly weldedwith nuts & bolts complete all as specified and directed. Make : Sintex / Hansel etc or equvts
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wal or fixed to LT panel board, 1100 volts grade (XLPE) heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sqmm 2 core with required aluminium cable lugs all as specified and directed. Make of Cable : Havells, Polycab, Gloster,Finolex
Supply and laying or fixing or passing through pipe from junction box to street light connection, 1100 volts grade heavy duty cable with PVC solid insulated aluminium conductor served with an inner sheathing PVC tape and over all PVC sheathed 2.5 Sqmm 2 core nominal cross section complete all as specified and directed.
Supply and laying or fixing or passing through pipe from junction box to street light connection, 1100 volts grade heavy duty cable with PVC solid insulated aluminium conductor served with an inner sheathing PVC tape and over all PVC sheathed 6 Sqmm 2 core nominal cross section complete all as specified and directed.
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 70 to 90 Watt LED flood light/street light fitting as required at site or as per sample incl taking out old unserviceable all as specified and directed . Make - Crompton /Philips /Havells
Supply and fixing Street / flood light fitting electronic constant current drivers/PCB/electronic gear suitable for 120 to 150 Watt LED flood light/street light fitting as required at site or as per sample incl taking out old unserviceable all as specified and directed . Make - Crompton /Philips /Havells
Taking down Old unserv HT joint end type 11 KV
S&F Cable jointing kit for 11 KV (Earthed) grade cable for heat shrink type end joint out door type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm Make : Raychem/Denson/M Seal/Birla3M
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 80 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
PCC (1:2:4) type B-2 using 40mm graded aggregate as in foundation for filling in, mass concrete complete all as specified and directed.
S&F GI tubing light grade 50 mm bore including grouting in PCC complete complete all as specified and directed for fixing post top lantern light. (Note PCC will be measured and paid seperately under respective item of BOQ.
S&F Sheet metal enclosure box 3.15 mm thick CRCA sheet with power coated paint (CPRI Approved) double door outdoor type including solid aluminium bus bar of capacity 100 amp 4 Nos strip with locking arrangements, enclosure box to be fixing on plinth foundation 1:2:4 and 0.5 Mtr avobe ground level including MS angle/ chanel consisting of necessary fixing arrangements for incoming & out going cables with cable glands, lugs, nut, bolts, washers and fixing arrengement , PCC work including necessary flat iron clamps with nuts, bolts & washers and Powder coated all as specified and directed.
S&F in replacement of old bulk head fitting by exterior application IP 66 protection bulk head fitting LED 10 watt alongwith covered with transparent clear sheet all as specified and directed Make : Crompton/Wipro/Philips etc
Supply and fix single automatic street light switch suitable for 3KW load complete with two numbers infrared sensor based NATURE SWITCH for automatic switching of street/security lights with one number two pole power contactor 40 Amps (Type MU40-2P,Cs90119) with coil voltage 220/240 V and incoming MCBs single pole - 01 No, outgoing MCBs single pole - 01 No of rating 32 Amps & circuit wiring with single core multi standard of size 10 sq mm lighting switch operation should be based on natural light lux level, Required luminance level for switching ON is < 30 Lux. The sensor (one service and one stand by) should also have part night operation facility for 4,5,6---11&12 hours. The sensor along with suitable power contactor (S), incoming and outgoing MCBs should be enclosed in a pole/wall mountable enclosure made of Rust proof, Electric shock proof, termite proof and FR grade confirming to IP66 complete all as specified and directed by Engineer in charge. Make - Swadeep 02EC3KW1P or its equivalent L&T/Legrand
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .