Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹32.7 L+₹41,833 (1.30%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹32.8 L+₹54,756 (1.70%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | L4₹34.7 L+₹2.5 L (7.61%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
31 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
SPECIAL REPAIR TO BLDG NO 45A (SINGLE JCOS LIVING ACCN) AND TOILETS OF SINGLE OFFRS ACCN AT CMDC (CC) UNDER GE E/M LUCKNOW
2021_MES_457013_1
GE/EM/LKO/HOSP/T-35 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
Class D or above category a (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹77,000
Yes
8 Sept 2021
3 Jul 2021
2 Aug 2021
3 Jul 2021
31 Jul 2021
19 Jul 2021
60 days
Amount
Taking down cement plaster on brick wall/ceiling, racking out joints hacking for key scrubbing down with water complete all as specified and directed by Engineer-in-Charge
M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick work surface finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge (Note : Integral WPC shall be measured and paid seprately )
M&L for rendering 10 mm thick on fair faces of brick work/ concrete surfaces in cement mortar 1:6 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
Supply only integral WPC of approved quality complete all as specified and directed by Engineer-in-Charge
M&L for rendering 5 mm thick on fair faces of concrete surfaces as in ceiling in cement mortar 1:3 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
Demolition of existing roof treatment of any type complete all as specified and directed by Engineer-in-Charge
M & L 15mm thick screed plaster on RCC slab CM 1:4 with using water proofing compound @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge (WPC to be measured and paid separately)
M & L for water proofing treatment on roof surfaces in the following manner:- (a) The surfaces shall be painted with hot bitumen grade 30/40 confirming to IS-73 @ 1.20 kg/sqm over a coat of bituminous primer conforming to IS-3384 @ 0.30 ltr/sqm. (b) supply & lay 3 mm thick APP water proofing membrane reinforced with non woven polyster matt laid using butane torch by torch on application with a side lap of 10 cm & 15 cm end lap weinghing not less than 3.5 kg/sqm.
M&L applying one coat of aluminium paints over new or previously untreated surface of any description, over 10cm in width or girth,not otherwise described including preparation complete all as specified and directed by Engineer-in-Charge
M&L for 30mm thick PCC 1:2:4 type B-0 using (12.5mm graded stone aggregate ) as in sunken floor mixed water proofing compound finished surface even and smooth with using extra cement complete all as specified and directed by Engineer-in-Charge Note : water proofing compound shall be measured seperately.
Rendering 15mm thick cement plaster in cement mortar 1:3 as in brick/concrete surface of sunken portion using water proofing compound complete all as specified and directed by Engineer-in-Charge Note : water proofing compound shall be measured & paid seperately
M&Lwire brushing and cleaning top surface of cement concrete including flashings and junction of parapet etc. and surface painting with a layers of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq.m. blinded with grit or pea size gravel @ 0.006 cu.m. per sqm and lightly tampered (area of flashings, etc., shall be added to the roof area) complete all as specified and directed by Engineer-in-Charge
M&L Cement concrete 1:5:10 type E2 using 40mm graded stone concrete as in sunken floor, foundations, filling and mass-concrete finished surface fair and complete all as specified and directed by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) rubbish off the premises complete all as specified and directed by Engineer-in-Charge
M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete and 15mm thick screed bed in CM 1:4 complete all as specified and directed by Engineer-in-Charge
M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in verticle surface such as skirting, dado, riese etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete and 10mm thick screed bed in CM 1:3 complete all as specified and directed by Engineer-in-Charge
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete and 15mm thick screed bed in CM 1:4 complete all as specified and directed by Engineer-in-Charge
M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete and 10mm thick screed bed in CM 1:3 complete all as specified and directed by Engineer-in-Charge
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps,risers, jambs, pillars, window-cills, cooking platforms and like over and including 20mm screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge
Demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by Engineer-in-Charge
M&L Brick work with fly ash bricks straight or curved on plan exc. 6 m mean radius built in CM(1:6) complete all as specified and directed by Engineer-in-Charge
M&L for applying two coats of Oil bound distemper over a coat of cement based white wall care putty average thickness 3mm thick including preparation of newly plastered surfaces complete all as specified and directed by Engineer-in-Charge
M&L for applying two coats of weather coat emulsion paint white or tinted over a coat primer over 2mm thick wall care putty including preparation on new plastered surfaces complete all as specified and directed by Engineer-in-Charge
M&L for complete removal of existing treatment and distempering on old walls and applying two coats of weather coat emulsion paint white or tinted over a coat primer over 2mm thick wall care putty complete all as specified and directed by Engineer-in-Charge
M&L for complete removal of existing treatment and distempering on old walls and applying two coats of Oil bound distemper over a coat of cement based white wall care putty average thickness 3mm thick complete all as specified and directed by Engineer-in-Charge
M&L applying three coat of white wash on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified and directed by Engineer-in-Charge
M & L for painting over new steel surfaces, width and girth over 10cm with two coats of synthetic enalmel paint including preparation of old decorated surfaces complete all as specified and directed by Engineer-in-Charge
Demolition of Concrete(reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge
S&F mild steel TMT bars 8mm dia and over ,cut to length , bent to shape requred, including cranking , bending spirally for columns hooking for columns hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge
M & L for Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed by Engineer-in-Charge
M & L RCC (Nominal mix) Type B0 1:2:4 (using 12.5mm graded stone aggregates) as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and directed by Engineer-in-Charge
Taking down chowkhats or frame (wooden/aluminium) n. exc. 1.5 Sqm each with shutters (with out taking off shutters from the frame) and taken as credit complete all as specified and directed by Engineer-in-Charge
Taking down chowkhats or frames (wooden/aluminium) with shutters without taking off shutter from the frames exc. 1.5 but n. exc 4 sqm each complete all as specified and directed by Engineer-in-Charge
S&F Pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed by Engineer-in-Charge
S&F Pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed by Engineer-in-Charge
S&F Bands, straps, clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed by Engineer-in-Charge
M&L PCC 1:3:6 type C1 using 20mm graded stone aggregate for fixing of hold fast and making good complete all as specified and directed by Engineer-in-Charge
S&F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes, as per specifications& drawing complete all as specified and directed by Engineer-in-Charge
S&F factory made solid PVC moulded door shutter 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, with wood free EPS, supplying and fixing in frame at site as per specification and drawings shown in section 8 of SSR part -II complete all as specified and directed by Engineer-in-Charge
M&L 30mm thick 2nd class hard wood Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.23(b) complete all as specified and directed by Engineer-in-Charge
M&L for 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed by Engineer-in-Charge
S & F for powder coated aluminium extruded sections (conforming to IS) (minimum thickness of powder coating 50 micron) three track sliding window shutter with frames comprising series-C (20mm) , duly fitted with neoprene beading, glazing clipss, locking devices, heat absorbing glass 4.8mm thickness (in 2 shutters) and with SS wire cloth of 0.46mm nominal dia of wire and average width of aperature 1.4mm (in one shutter) complete all as specified and directed by Engineer-in-Charge
S & F for powder coated aluminium extruded sections (conforming to IS) (minimum thickness of powder coating 50 micron) fixed type ventilators with partiction sections in two parts (one part fixed with frosted glazing and other part fixed with SS wire cloth) duly fitted with neoprene beading, glazing clipss, locking devices, figured glass glass 3mm thickness complete all as specified and directed by Engineer-in-Charge
S&F 75mm size butt hinges medium weight (ISI Marked), rolled mild steel complete all as specified and directed by Engineer-in-Charge
300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge
S&F 150mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed by Engineer-in-Charge
S&F 100mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed by Engineer-in-Charge
S&F 150mm size Aluminium anodized barrel Tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge
S&F 100mm size Aluminium anodized barrel Tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge
S&F Aluminium alloy, anodized, sliding door bolt (ISI Marked) of 300mm with hasp & staple (Bolt type) and fixing clips of sheets, coat or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed by Engineer-in-Charge
M&L Preparation of new wooden surface exceeding 10cm width or girth and applying two coat of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer-in-Charge
S&F 2nd class hardwood Beads, straight (any size) for glazed or gauzed joinery, renewed, including mitres etc complete all as specified and directed by Engineer-in-Charge
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in steel window clips and wooden beading in wooden joinery complete all as specified and directed by Engineer-in-Charge
S & F for 150 mm floor door stopper of aluminium alloy body and tonge,anodised with hard drawn steel spring complete all as specified and directed by Engineer-in-Charge
S &F 3mm thick aluminium composite panel with aluminium frame in doors incl clip and neosprene rubber beading, aluminium tower bolts, aluminium sliding door bolts of 250mm long incl necessary fixing arrangements complete all as specified and directed by Engineer-in-Charge
S&F vitreous china Europeon Water Closet (one piece) of specified make with flushing cistern & white seat cover complete all as specified and directed by Engineer-in-Charge .(Cat No: SLS-WHT-6851S300UF of Make- Jaquar of equivalent)
S&F for Vitreous china Wash down water closet pan (Pedestal pattern) white including connection with 'P' trap including fixing bolts, PVC valve less , syphonic action type flushing cistern, low level, white with inlet, ball valve, float and handle including brackets and with plastic water closet seat and cover back closed pattern with flat bottom & cover and mild steel chromium plated hinging device including flush pipe of PVC 32 mm dia for low level cistern and PVC connection 15 mm size with PTMT nuts and 450 mm long complete all as specified and directed by Engineer-in-Charge
S&F CP Angle stop cock ( one way) long thread with wall flange , fancy type screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified and directed by Engineer-in-Charge
S&F CP Angle stop cock ( two way) long thread with wall flange , fancy type screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified and directed by Engineer-in-Charge
S&F for health faucet, chromium plated rising spray with wall brackets with 1.5m long metallic flexible tube, Gem cat No 350083 or equivalent of Jaquar or cera". with 15 mm dia fixed in repair complete all as specified and directed by Engineer-in-Charge
S&F for Automatic Soap dispensor cat No 82220105 of CERA ceramics or equivalent makes complete all as specified and directed by Engineer-in-Charge
S&F Toilet paper holder of chromium plated (specified make) fixed to walls with chromium plated (CP) brass screws complete all as specified and directed by Engineer-in-Charge
S&F Pillar taps, fancy type cast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without lettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed by Engineer-in-Charge
S&F in repair vitreous china,white, wash hand basin, flat back size 550x400mm 'including MS brackets including cutting for and pinning in, but excluding waste pipe complete all as specified and directed by Engineer-in-Charge
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt I. capacity of tank 500 litres omplete all as specified and directed by Engineer-in-Charge
S&F Ball brass valves, high pressure, with polythene float & steel rod & fly nut complete, screwed for iron pipe or brass ferrule and fixed 20 mm bore pipe complete all as specified and directed by Engineer-in-Charge
S & F 20mm dia gun metal or gate valve with ironwheel head screwed both for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
S & F 15mm dia gun metal or gate valve with ironwheel head screwed both for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
S & F 15mm dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
S & F 15mm Tubes, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge
S & F 20mm Tubes, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer-in-Charge
S & F 100 mm dia grating doom of PTMT (min weight 20 gm each) complete all as specified and directed by Engineer-in-Charge
S&F looking mirror 600x450 mm consisting of 4 mm thick glass mounted on 4 mm thick plywood and providing decorative type wooden beading with varnish finishcomplete all as specified and directed by Engineer-in-Charge . (Make of glass : Modi float / Saint globin / Triveni float gla
S & F chromium plated soap tray fixed with rawl plugs complete all as specified and directed by Engineer-in-Charge
S& F brass chromium plated tubular towel rail 20mm dia D type, 60 cm long incl flanges/ brackets complete all as specified and directed by Engineer-in-Charge
S& F Brass Chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed by Engineer-in-Charge
S& F for 15mm Stop valves, cast copper alloy, screwed down, high pressure, fancy type, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge
S&F bib taps for 15 mm bore pipe cast copper alloy chromium plated fancy type with crutch or butterfly handle,screwed down, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
S &F 110mm bore (SWR) pipe single socketed in any length with rubber ring joints, laid in trenches or in floors/fix to wall complete all as specified and directed by Engineer-in-Charge
All as per item No 82 here-in-before but dia of 75mm
M&L (SWR) 75mm dia floor trap plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge
S&F 110mm bore PVC (SWR) junction single, (single Tee) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge
All as per item No 85 here-in-before but dia of 75mm
S &F 110mm bore (SWR) pipe single socketed in any length with rubber ring joints,fixed to walls complete all as specified and directed by Engineer-in-Charge
All as per item No 87 here-in-before but dia of 75mm
S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge
All as per item No 89 here-in-before but dia of 75mm
S&F 110mm bore PVC (SWR) bend of any radius complete all as specified and directed by Engineer-in-Charge
All as per item No 91 here-in-before but dia of 75mm
S&F in PVC (SWR) 125/110 mm gully trap with grating including jointing with solvent cement. complete all as specified and directed by Engineer-in-Charge
S & F for corner sheet glass shelf of 4.8mm thick fixed with Stainless steel clamps and other necessary fittings suitable for holding in wall corner with minimum 200 mm length in front circular shape, complete all as specified and directed by Engineer-in-Charge
S & F for sheet glass shelf of 4.8mm thick fixed with Stainless steel clamps and other necessary fittings suitable for holding in wall of minimum size 300x150mm , complete all as specified and directed by Engineer-in-Charge
M & L for 32mm dia Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (un-reinforced) in ground floor and pavings n. exc 15 cm thick (above or below ground level) complete all as specified and directed by Engineer-in-Charge
M&L 75mm th PCC 1:3:6 type C-2 as in sub base, Paving, plinth protection, finished even and fair complete all as specified and directed by Engineer-in-Charge
S & F in repair of PVC coated drapery rod of 20mm dia complete all as specified and directed by Engineer-in-Charge
S & F brass coated knob at both ends of drapery rod of 20mm dia complete all as specified and directed by Engineer-in-Charge
Taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing complete all as specified and as directed by Engineer-in-Charge.
M&L point wiring for one light/fan point controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly complete all as specified and as directed by Engineer-in-Charge.
All as above item no 102 hereinbefore but but socket outlet point 5 amps on independent board
All as above item no 102 hereinbefore but one socket outlet point on same baord
M&L point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and1.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly complete all as specified and as directed by Engineer-in-Charge.
S&F Polycarbonate switch piano flush type, SP,5/6 Amps, complete all as specified and as directed by Engineer-in-Charge.
S&F Polycarbonate switch piano flush type, SP, 16/20 Amps, one way equivalent of other specified make complete all as specified and as directed by Engineer-in-Charge.
S&F Polycarbonate socket out let 2 in 1 socket 5 pin, (6 Amps) flush type controlled by one switch, specified makecomplete all as specified and as directed by Engineer-in-Charge.
S&F Polycarbonate socket out let 6 pin, 20 Amps ISI Marked 20 Amps 240 Volts flush type, make complete all as specified and as directed by Engineer-in-Charge.
M&L Ceiling rose, Pilot 3 Plate ceiling rose 6A, complete all as specified and as directed by Engineer-in-Charge.
S&F Indian standard fan step regulator 100 watt complete all as specified and as directed by Engineer-in-Charge.
S&F Epoxy powder coated distribution box SPN 8 way, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door complete all as specified and as directed by Engineer-in-Charge. make.Havells/HPL/Legrands
S&F MCBs of the following rating and to be housed in DBs catered here in after complete all as specif and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCBs are including in unit rate of each MCB of any rating) SP,20 to 32 Amps, 240 Volts
All as per item No 113 above but SPN 32 to 40 Amps, 240 Volts
M&L for sub main wiring comprising two single core, 4 Sq mm nominal cross sectional area multi on same copper conductor cable, PVC insulated FRLS Grade unsheathed 1100 Volts grade drawing in and over PVC conduits and conduit fittings complete (concealed type) including S&F 4 Sq mm nominal cross sectional area on same copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and as directed by Engineer-in-Charge. (Cutting chases and making good of disturbed surfaces shall deem to be including in the unit rate quoted by tendered).(Note :- Extra length of cables/wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) Make of PVC insulated unsheathed FRLS copper cable Finolex/Havells/POLYCAB .
M&L for concealed sub main wiring comprising two single core, 10 Sq mm nominal cross sectional area multi on same copper conductor cable, PVC insulated FRLS grade unsheathed 1100 Volts grade drawing in and over PVC conduits and conduit fittings complete (concealed type) including S&F 10 Sq mm nominal cross sectional area on same copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and as directed by Engineer-in-Charge. (Cutting chases and making good of disturbed surfaces shall deem to be including in the unit rate quoted by tenderer). (Note :- Extra length of cables/wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) Make of PVC insulated unsheathed FRLS copper cable Finolex/Havells/POLYCAB .
M&L Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in to ground (earth pit) not less than 2.25 meters deep below GL with top edge of earth plate not less than 1.50 m below ground level, connected to GI lead wire of 4 mm dia. (7.50 m long) by means of nuts, bolts and washers, check nuts of GI and protected by the GI pipe light grade 1.5 mm nominal bore (7.50 m Long) for earth plead wire, watering pipe light grade of 20 mm nominal bore, 0.63 mm thick CI funnel, wire mesh etc complete including necessary earth work and excavation in any type of soil, PCC 1:2:4 type B1 earth pit and Precast RCC cover 50 mm thick dully reinforced with 6 mm dia, MS round bars @ 100 mm C/C both ways, earth testing point, making good to floor complete all as specified and as directed by Engineer-in-Charge.
S&F plug and socket DBs with Single pole MCBs rated 20 Amps capacity all as specified or equivalent of other make including making niche in wall and mounted flush complete all as specified and as directed by Engineer-in-Charge. Make - Legrand/Anchor/Hager/Havells
S&F Distribution Board TPN with and including of DPX MCCB 35 KA 160 Amps MCCB FP, as incomer and SP/TPN MCBs as outgoing protection class IP 54, 8 way (DPX 160+24) with metal door double door Cat No 420097 of Legrand or equivalent other specified Note :- FP MCCBs 35 KA 160 Amps1 No and 24 Nos MCB SP 32 Amps 230 Volts and Blanking plate shall be measured and paid under this this item ) Make - Havells/Hager/HPL /Legrand/L&T
Supply and fixing flexible copper cable three core suitable for connection of light fittings/ FTL fittings of any type complete all as specified and as directed by Engineer-in-Charge.
S&F Lamp holderbattern/anguler type , PVC/polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed by Engineer-in-Charge.
S&F LED batten with LED tube light rod 18 watt 4 feet retro type complete all as specified and as directed by Engineer-in-Charge.
Taking down old ceiling fan any size after servicing and painting, refixing same complete all as specified and as directed by Engineer-in-Charge.
Taking down old exhaust fan any size after servicing and painting, refixing same complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 50 sqmm cross sectional area, 3.5 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and as directed by Engineer-in-Charge. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and as directed by Engineer-in-Charge. Note :- Punned thickness shall only be considered for payment
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and as directed by Engineer-in-Charge.
Boring / drilling (Horizontly ) manually under existing road Max 10 M in width suitable for passing GI tubing 40 to 100 mm bore, complete all as specified and as directed by Engineer-in-Charge.
Mild steel galvanized tubes light grade ISI marked 40mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe ,compllete all as specified and as directed by Engineer-in-Charge.
M/s Reliable Electromech Systems
M K Engineers and Contractors
PUMA POWER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .