| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹47.8 L+₹1.4 L (3.10%)Rejected-AOC | L2 | Rejected-AOC OK | |
| 3 | L3₹47.9 L+₹1.6 L (3.38%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹48.0 L+₹1.6 L (3.54%)Rejected-AOC | L4 | Rejected-AOC OK | |
| 5 | L5₹49.0 L+₹2.6 L (5.59%)Rejected-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L5 | Rejected-AOC OK |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
20 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI MAHAVIR SINGH, IDSE
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD
SPL REPAIRS TO BLDG NO 12 TROOPS LIVING BARRACK NO 1 TRAINING BATTALION OF AOC CENTRE OF AGE B/R (SOUTH) NO II AND AGE E/M (SOUTH) UNDER GE (SOUTH) SECUNDERABAD
2021_MES_455750_1
GE (S)/SEC/TOKEN - 12 OF 2021 - 22
Open Tender
Civil Works
Item Rate
180 days
Secunderabad
For Enlisted contractors class D and above category a (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
5 documents required · 5 mandatory
₹500
GE SOUTH, MUDFORT, SECUNDERABAD
₹96,000
Yes
4 Oct 2021
29 Jun 2021
22 Jul 2021
29 Jun 2021
20 Jul 2021
14 Jul 2021
30 Jun 2021 - 13 Jul 2021
60 days
Amount
Dismantling wall and ceiling boards (fibre, purlp, insulation etc) or insulation boards/slabs/blankets any thickness including frame work complete all as specified and as directed..
S & F anodised aluminium snap grid frame work of size 605 x 605mm for false ceiling complete all as specified and as directeded..
M & L for 600 x 600 x 4mm thick Non asbestos cement Designer celing E - boards ( Design as approved by Engr in charge) , fixed on ceiling frame work complete all as specified and as directed
S & F Hangers 4mm dia GI (upto 2400 long) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners as per site requirement complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not other wise specifically provided for complete all as specified and as directed
Demolition of stone slabs & tiles of any description or thickness in floors, aprons etc. laid, bedded & pointed in any mortar complete all as specified and as directed
M & L Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors incl 15mm thick screed bed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed..
M & L Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in Skirting over 10mm thick packing coat in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed..
M & L 25mm thick cement concrete type B0, 1:2:4 (12.5mm graded stone aggregate) as in sub base complete all as specified and as directed..
S & F 18-20 mm thick kota stone slab as in floors over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror finish and rounding chamfered edges where directed complete all as specified and as directed.
All as per item No. 10 here in before but 16 to 18mm thick kota stone slab as in small width in vertical surfaces like landings risers, treads, skirting, dado etc over and including 10mm thick packing coat in cement mortar 1:4 complete all as specified and as directed.
M & L for marble work white 18 -20mm thick laid in floors over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 with kota stone for designing purpose size and pattern as directed including cutting, grinding and polishing etc complet all as specified and as directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quions arches pillars etc complete all as specified and as directed.
M & L for brick work with sub class "B" bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed.
Taking down plastering on brick wall& ceiling etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed..
M&L Rendering 10 mm thick cement plaster in CM 1:3 with river sand on concrete surfaces on ceiling incl finishing even & fair w/o using extra cement complete all as specified and as directed..
M&L Rendering 15 mm thick cement plaster in CM 1:6 with river sand on concrete surfaces on wall incl finishing even & fair w/o using extra cement complete all as specified and as directed..
M&L for 15mm thick rendering on brick wall or concrete surface in cement mortar 1:4, with river sand surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for applying Three coat of white wash on newly plastered ceiling including preparation of surfaces complee all as specified and as directed.
M & L for applying 2 coats of OBD on new surface over one coat of priming paint over two mm thick wall care putty for smooth finish of surface of walls complete all as specified and as directed.
M & L for preparation of new plastered or un pastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
M & L for applying one coat of white wash on ceiling including preparation of old decorated surfaces complee all as specified and as directed.
M & L for applying one coat of white wash on wall including preparation of old decorated surfaces complee all as specified and as directed.
M & L complete removal of existing treatment of walls and applying 2 coats of OBD over one coat of chok whitening primr over two mm thick wall care putty for smooth finish of surface of walls complete all as specified and as directed.
M & L complete removal of existing treatment of walls and applying 2 coats of cement base paint over one coat of primer incl preparation of surface complete all as specified and as directed.
Supply only water proofing compound complete all as specified and as directed
M & L chequered cement concrete tiles size 30cm x 30cm x 20-25mm thick set, incl 15mm thick screed bed in CM 1:6 over 25 mm thick PCC (1:2:4) Typee - B1 using 20 mm graded stone aggregate jointed and pointed in neat cement slurry in flooring complete all as specified and as directed.
Taking down chowkats of frames with shutters (without taking of shutters from the frame) exc 1.50 Sqm but n.exc 4.00 Sqm each.
Taking down shutters exc 1.00 Sqm but n.exc 2.00 Sqm each.
Taking down shutters upto 1.00 Sqm each.
M & L second class hard wood Plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed
S & F 35mm thick Glazed and skeleton door shutters of second class hard wood hollock, prepared to receive glass, gauze, etc. (without sash bars), fixed without or mired beads supplid and fitted to chowkats and for securing glass, gauge etc size of members, of shutters as per section 8 clause 8.24(a) of SSR Patr-I (2009) complete all as specified and as ditected.
S & F 35mm thick Glazed and skeleton window shutters of second class hard wood hollock, prepared to receive glass, gauze, etc. (with sash bars), fixed without or mired beads supplid and fitted to chowkats and for securing glass, gauge etc size of members, of shutters as per section 8 clause 8.24(b) of SSR Patr-I (2009) complete all as specified and as ditected.
S & F second class hard wood factory made panelled door shutters 35mm thick, (2 panels) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces as per IS 1003 (Part-I) kiln seasoned and chemical pressure treated complete all as specified and as directed.
S&F Butt hinges of 100 mm medium weight cold rolled mild steel and fixing complete all as specified and as directed..
S & F in MS barrel tower bolt, stove enamelled black 150mm long with bright bolt and fixed complete all as specified and as directed..
S & F in MS barrel tower bolt, stove enamelled black 200mm long with bright bolt and fixed complete all as specified and as directed..
S & F mild steel door bolts plate type stove enamelled black with bright bolt not less than 16mm dia with and including a minimum of 6 bolts and nuts four on bolt plate two on staple length of bolt 300mm long. complete all as specified and as directed..
S & F MS pressed handles oval type, stove enamelled black, 125mm long complete all as specified and as directed
S & F MS pressed handles oval type, stove enamelled black, 150mm long complete all as specified and as directed
M & L for framed work such as grills, gratings etc with ends of bars, framed guard bars, ladders etc and similar works conforming to Fe-290 Gde E-165.
S&F sheet glass ordinary quality 3mm thick and glazing with oil putty in squares n.exc 0. 5 Sqm each pane complete all as specified and as directed
S&F in Repair sheet glass ordinary quality 3mm thick and glazing with oil putty in squares n.exc 0.5 Sqm each pane incl hacking out old broken glass complete all as specified and as directed
S & F galvanised MS wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 and fixed with tinned tacks galvanised wire stapples etc complete all as specified and as directed
S & F in repair galvanised MS wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 and fixed with tinned tacks galvanised wire stapples etc incl removal of old mesh complete all as specified and as directed
M & L applying two coats of synthetic enamel paint on wooden surfaces over a coat of pink primer incl preparation of new surfaces of any description, not otherwise, described, over 10cm width or girth complete all as specified and as directed..
M & L applying one coat of synthetic enamel paint on wooden surfaces incl preparation of old wooden surfaces of any description, not otherwise, described, over 10cm width or girth complete all as specified and as directed..
M&L Preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and as directed..
Removal of old treatment of any description and roughening the of old concrete roof surfaces by picking, sweeping clean and washing down with water to remove dust etc including removing the debris to a distance of n.exc 100 mtrs away from plinth protection.complete all as specified and as directed
M& L for PCC 1:2;4 type B1 using 20mm graded aggregate as in padding (level course) on roof surface averaging 40mm thick etc complete all as specified and as directed.
M & L for rendering 10mm thick in CM 1:3 with river sand mixed with integral water proofing compound as per manufacturer's instructions as in roof surface and chajjas, finished the surface fair and even without using extra cement (Note:- Supply of water proofing compound will be measured and paid separately).
M&L priming the plastered roof surfaces with bitumenous primer @ 0.30 Kg / sqm over the primer apply hot bitumen 1.20 Kg/sqm uniformly and applying APP based polymeric membrane minimum weighing 3 Kg per Sqm and minimum 3mm thick reinforced with polyster non wove fabric (Wt not less than 150 gms/per Sqm) and laid on primed surface by forced application and apply a coat of bitumen base aluminium paint @ 0 20 Kg / Sqm over the polymeric membrane complete all as specified and as directed
M & L for PCC 1:2:4 type B1 using 20mm graded aggregate as in coping /padding on wall/ roof surface complete all as specified and as directed.
S & F (in repairs) 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls with necessary fittings such as FI clamps every 1.0 mtr etc complete all as specified and directed. NOTE : FI clamp shall be measured and paid separately
S&F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), ; clamps; hold fasts; wind ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe410-0 or Fe 310-0
S & F PVC (SWR) bends of 110mm bore dia complete all as specified and as directed.
Dismantling single layer of mangalore tiles in roofing complete all as specified and as directed
Dismantling battern for tiles, shingles etc of any size incl, tilting fillets of spacing exc 15 cm. complete all as specified and as directed
Dismantling timber scantling 40 Sqm and over in sections in any position unframed work.
S&F in any position IInd class hard wood timber scantiling clean sawn size as per site requirement complete all as specified and as directed
All as per item No. 60 above but fixing only
S & F 2nd class hard wood in fillets, square, rectangular in section wrought, secured with nails sectional area exc 13 sq cm and n.exc 25 Sq cm fixed in repairs.
S & F rolled section as in main and cross beams, hip and jack rafters purlins, where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connected plates conforming to Fe-410-W. all as sepcified and directed by Engr-In-Charge.
S & F pre painted galvalume aluminium zink coating GI based corrugated steel sheeting 0.5mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws complete all as sepcified and directed by Engr-In-Charge.
S & F pre painted galvalume aluminium zink coating GI based plain steel sheeting 0.5mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws complete all as sepcified and directed by Engr-In-Charge.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as sepcified and directed by Engr-In-Charge.
Taking down existing unserviceable point wiring of any description/type/ size of light/ fan/tube/power/two way/bell point etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed
M & L for Concealed Conduit Point wiring with 1.5 Sq mm copper conductor single core PVC insulated cable FRLS type 1100 V multistranded drawn through conduit and including rigid PVC conduit and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 1.6 mm thick MS duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated hylam sheet including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc all as specified for One light point controlled by one, one way switch 5A, SP
All as per Sl item No 70 above but for One ceiling / exhaust fan point controlled by one, one way switch
All as per Sl item No 70 above but for One 2/3 pin 5 Amps switch socket outlet point controlled by one switch on the same board
All as per Sl item No 70 above but for One 3 Pin 5 Amps switch socket Independt board
All as per item No 70 here-in-before but using 4 Sq mm single core copper conductor cable of multistranded PVC insulated FRLS 1100 Volts grade for 5/15 Amps switch socket combination point including running of 4 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
S & F Switch piano type single pole one way flush type 5 Amps capacity 230 volts.
Supply and fix in repair switch socket combination flush type multipurpose 2/3 pin 5 Amps, 230 Volts complete all as specified.
Supply and fix in repair socket outlet flush type multipurpose 2/3 pin 5 amps, 230 volts all as specified
Supply and fix in repair switch socket combination flush type multipurpose 5 in 1, 5/16 Amps, 230 Volts complete all as specified.
S & Fix in repair ceiling fan regulator step type AC 240 volt suitable for 1200/1400 mm sweep.
S & F in repair ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified.
S&F sheet metal enclosure vertical type MCB DB in repair TPN 4 way double door with 200 Amps rated bus bar 415 volts suitable for and including 63 Amps TPN MCCB 16 KA as incommer and 12 Outgoing SP MCB's with magnetic locking system complete all as specified. Note: MCB SP Shall be measured and paid seperately, all as specified and directed by Engg in Charge
S and F sheet metal enclosure MCB DB in repair SPN 8 way with 200 Amps rated bus bar 240 Volts double door with magnetic locking system complete all as specified and as directed
S & F MCB in repair SP 230V suitable for fixing on MCB DB of capacity 6 to 32 Amps complete all as specified and as directed by Engg in Charge
S & F MCB in repair SPN 230V suitable for fixing on MCB DB of capacity 40 Amps complete all as specified and as directed by Engg in Charge
S & F wall mounted box type LED of 18/22 watt with LED Lamp, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with 2 Nos round blocks with necessary fixing arrangements and connecting to the point wiring with necessary flexible copper conductor multistranded three core of suitable length & size from fitting to the ceiling rose complete and as directed by Engr-in-Charge.
S & F LED bed side in replacement light fitting with lamp capacity 7W, 6500K, adjustable type including all accessories and as directed by Engr-in-Charge. Make : Havells, Bajaj, Philips
M & L for Submain wiring with two single core 6 Sq mm PVC insulated FRLS copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC concealed conduit and conduit accessories of 25 mm dia medium grade including running up of 6 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing finishes all as specified. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth earth lead 4 mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe med grade 15mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI pipe med grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 5 of SSR Part-I and connection to earth test point all as specified incl testing on completion. Note :- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 4 mm size and protection pipe of 15 mm bore GI light grade.
Disconnecting and removing ceiling fan of 1200/1400 mm sweep any height from electrical connection bringing down, dismantling, cleaning internally and externally by thoroughly examination replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler , one coat after cleaning all dust etc & testing complete all as specified. NOTE :- (1) Necessary repairs/ replacement of unserviceable parts shall be measured and paid seperately.(2)Labour element for replacing of u/s parts deemed to be included in rate quoted.
Material and labour for rewinding of the ceiling fan complete with equivalent new super enamelled copper wire of existing gauge and weight as per manufacturer's design and instructions including varnishing and external painting in white colour for ceiling fan of any make and any sweep complete all as specified and directed including taking out burnt copper wire. Note: old winding material is property of the contractor
Supply only the following items suitable for ceiling fans / exhaust fans of any size and sweep and make :Capacitor 2.5 Mfd capacity 240 Volts.
All as per Sl item No 91 above but for Sealed ball bearing
All as per Sl item No 91 above but for Rubber bushes
S & F in repair Security Lights of 1x25 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all as specified and as directed by Engg-in-Charge.
M & L bracket made out of GI pipe of suitable dia not less than 1.2 mtr long and fixed on walls with 2 nos MS clamps made out of MS flat of suitable size thick complete with MS nuts, bolts and washers etc bent to required shape complete all as specified and directed by Engg-in-Charge
Supply & Lay in repair on wall/in ground/on pole ISI marked XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 1100 volts laid in trenches, floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified of size 3.5 x70 sqmm
Excavation in trenches not exceeding 1.5 mtr width and not exc 1.5 mtr in depth and getting out in hard /dense soil for laying / repairing of LT cable / GI pipe.
M & L for supplying and spreading river sand in cable trenches providing for cable cushioning as directed. NOTE :- Punned thickness of sand only will be measured and paid.
Removal of surplus soil to a distance not exc 50 mtrs away and depositing where directed at a level not exc 1.5 mtr above the starting point.
Returning , filling incl spreading levelling watering and well ramming in layers not exc 25 cm thick.
S& Lay PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm
S& Lay in repair GI tubing light grade 40 mm dia in protection of cable at roads crossing/hard standing/pole protection fixed with clamps as per site requirement etc all as specified and directed.
Provn of cable TV socket outlet point including PVC conduit 20mm dia upto 15m long to reach out the intake point
Cutting of bituminuous road / hard standing of size not exceed 30 cm in width and not exceeding 90 cm in depth for laying of UG cable/protection Pipe including making good the disturbed portion so as to match with the existing finishes with PCC 1:2:4 type B1 concrete complete all as specified and as directed
S & F in repair down rods of 20 mm dia steel conduit with necessary holes and painting in white colour suitable for ceiling fans of size 1200 mm sweep including clamps, nut & bolts as specified and as per site requirement.
SHAH ENTERPRISES
M/s RAMA LAKSHMI CONSTRUCTIONS
SAI RAM CONSTRUCTIONS
SAI RUPA CONSTRUCTIONS
SURA INFRASTRUCTURE
K LAKSHMAN SINGH AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .