Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.8 LAccepted-AOC 482 GALI NO 4 TULSI VIHAR AZAD NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | L1 | Accepted-AOC ok | |
| 2 | L2₹73.6 L+₹1.8 L (2.56%)Rejected-Finance 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | L2 | Rejected-Finance L2 | |
| 3 | L3₹77.7 L+₹5.9 L (8.29%)Rejected-Finance GAUSHALA MARKET TEHSIL NARNAUL NARNAUL 123001 | NARNAUL | NARNAUL | HARYANA | 123001 | L3 | Rejected-Finance L3 |
Tender Value
₹65.4 L
EMD Value
₹1.3 L
Closing Date
30 Dec 2019, 5:00 pmClosed
Rajesh Ahuja
XEN (E) Rewari
CONSTRUCTION OF ADDITIONAL BLOCK OF PWD REST HOUSE AT NARNAUL IN DISTT. IN MOHINDERGARH (PDG. E.I. INTERNAL, LIFTS ONLY)
2019_HRY_112806_1
CONSTRUCTION OF ADDITIONAL BLOCK OF PWD REST HOUSE
Open Tender
Electrical Works
Works
90 days
XEN (E) Rewari
Refer DNIT
3 documents required · 3 mandatory
₹5,000
Yes
Executive Engineer,Electrical Division
₹1.3 L
Yes
19 Nov 2020
16 Dec 2019
31 Dec 2019
16 Dec 2019
30 Dec 2019
16 Dec 2019
Amount
Suply and erection of PVC copper insulated and sheathed 2-core circular flexible wire. Size 1.50 sqmm ( 48 / 0.20mm).
Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections.15 amp.to 60 amp. 415 V ,10 KA 3-phase.
100 amp.to 220 amp.415 V,10 KA 3-phase.
Size 2.50 sqmm ( 80 / 0.20mm).
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide.Size 40 mm x 40 mm x 6 mm.
Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
Supply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc. S.P.N. enclosure for single pole MCB 20 amp.
Supply and erection of blanking sheet in existing distribution board.
(L) Miniature Circuit Breaker and Isolator. Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
SPN MCB of 9 KA breaking capacity 6 amp. To 32 amp.
TPN MCB of 9 KA breaking capacity 6 amp. to 32 amp.
TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp.
Call bell 220 / 230 volts A.C. bakelite with double coil.
Electric buzzer 220 / 230 volts A.C. bakelite with double coil.
Bell push with 4 metres 2-core , 0.50 sqmm (16 / 0.20 mm).PVC flexible wire.
Bakelite angle / straight button holder large size.
Bakelite sheet including fixing with brass screws and washers.3 mm thick .
Ceiling rose flush / surface type .
Supply and erection of rectangular bulk head fitting of size 17 cm x 14 cm, aluminium casted with aluminium colour out side and white stove enamelled inside/complete with guard, glass etc. secured by brass screws suitable upto 100 watts lamp with B.C. lamp holder but without lamp.
Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.(erection of LED luminairsof all types).
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job. .
Supply and erection of lumineous bell indicator complete including making necessary connections and fixing the same on wall etc. to complete the job in all respect.
Pdg., one extra junction box with 0.55 metre long 20mm dia conduit pipe for the erection of fluorescent tube fitting complete with all required labour and material.
Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
Erection of cabin fan complete with necessary earthing including carriage from local railway station /goods transport /PWD store to the site of work.
Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick.
Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness on surface.
Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness on surface.
Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed.
Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed.
Heavy guage welded conduit pipe 32 mm dia 1.60 mm thickness flushed.
PVC pipe 80 mm dia.
PVC pipe 65 mm dia.
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) comlete as required.
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode.
Pdg. and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required .
Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required .
Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material.
Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material.
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required .
Pdg. and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required .
Excavation of earth pit 180 cm. round at top and 90 cm. at bottom 4.5 metres deep and refilling the same in hills including supply of necessary charcoal / coke and salt mixture.
Supply and erection of 60 cm. X 60 cm. X 6 mm thick galvanised Iron plate including nacessary bolts and nuts to G.I. tape .
Pdg. Standard watering tank including down pipe and C.I. cover with locking arrangement etc.
Supply and erection of 20 mm x 3 mm thick lightning conductor G.I. tape fixed with suitable G.I. stapples of same size.
Supply and erection of G.I. tape 32 mm x 6 mm thick from earth electrode directly in ground and surface , fixed with G.I. stapples of same size.
Supply and erection of 25 mm dia meter 1.5 metre long lightning G.I. tube rod tapered in to a point at the top with 16 cm. X 16 cm x 3 mm thick G.I. base plate and necessary nuts and bolts with washer.
Prioviding and fixing , testing joint made of 20mm x 3mm thick G.I. strips 125mm long with 4 Nos. G.I. bolts and nuits, check nuts with washer complete.
Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia.
Supply and erection of caution notice plate in three languages.
Supply and erection of shock restoration chart in glass frame
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work.10 sqmm .
Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S.rod welded / revitted at the top with 10 cm. Dia 5 mm thick G.I.plate inscribed with `cable' world on it , having a cross arm 30 cm. long of the same dia welded at the bottom , in existing trench 45 cm. below ground level .
Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe.Fan Point - Medium .
Fan Point- Long.
Light point -Short.
Light Point - Medium.
Light Point- Long.
Twin control light point with 2 way 5 amp. single pole switch- Medium point.
Twin control light point with 2 way 5 amp. single pole switch-Long point.
Light point without control- Medium point.
Light point without control- Long point.
Call bell point including M.S. box of size 180 mmX100mmx60mm deep for call bell - Medium point.
Call bell point including M.S Box of size 180mmx100mmx60mm deep for call bell - Long point
3 pin 5 amp. plug point including earthing the 3rd. pin etc. -Short point.
3 pin 5 amp plug point including earthing the 3rd. pin etc. - Medium point.
3 pin 5 amp. plug point including earthing the 3rd. pin etc.- Long point.
3 pin 15 amp.plug point including earthing the 3rd. pin etc. with 4 sq mm PVC insulated copper conductor cable- Medium point.
3 pin 15 amp plug point including earthing the 3 rd. pin etc.with 4 sq mm PVC insulated copper conductor cable - Long point.
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe.Size 1.5 sqmm (3 / 0.81mm).
Size 2.50 sqmm (3 / 1.05mm).
Size 4 sqmm (7 / 0.85mm).
Size 6 sqmm ( 7 / 1.05mm).
Size 10 sqmm
4-way, TP & N (Horizontal) (8+12)
8-way, TP & N (Horizontal) (8+24)
12-way, TP & N (Horizontal) (8+36)
Supply and erection of double pole / Four pole Residual current circuit breaker ( RCCB / ELCB) suitable for operation on 240/415 V, 5 Hz. AC supply installed in existing sheet steel enclosure including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work.40A / 415V 4P ELCB with 100mA senstivity.
63A / 415V 4P ELCB with 100mA senstivity.
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work.20 mm dia
25 mm dia
Supply and erection of copper lugs including crimping etc.upto the entire satisfaction of Engineer-in-Charge of work.1.5 sqmm to 2.5 sqmm
4 sqmm to 6 sqmm
Supply and erection of sheet steel enclosure3 / 4 pole for ELCB / MCB fixed on wall or existing board etc. including bondig to earthcomplete in all respect up to the entire satisfaction of the Engineer-in-Charge of work
Supply and erection of MS sadles and clamps on wall / RCC parapit for fixing underground cable at distance of 0.60 metre centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect.
Supply and erection of MS box made of 16 gauge MS Sheet recessed in wall, with arrangement of fixing brass screws, 2 Nos. check nuts and one No. PVC bush of required size including all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of work.with 2 coats of primer.
With GI coating (anodized) suitable for modular accessories.
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect.10 amp. 1 way switch
10 amp. 2 way switch
20 amp. switch
10 amp. socket
16 amp. socket
Bell push
Fan regulator
Call bell Ding-Dong ( Monitca )
Blinking Plate
Pdg. and fixing GI concealed sheet metal boxes inner and outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material requiered to complete the job in all respect.1 & 2 module
3 Modules
4 Modules
6 Modules
8 Modules
12 Modules
Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed.
Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections,digging and refiling of trenches. . 300 Sq. mm 3.5 Core Armoured Cable.
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . 10 Sq. mm 2 Core Armoured Cable.
50 Sq. mm 3.5 Core Armoured Cable.
95 Sq. mm 3.5 Core Un-Armoured Cable.
300 Sq. mm 3.5 Core Armoured Cable.
10 Sq. mm 4 Core Armoured Cable.
25 Sq. mm 4 Core Armoured Cable.
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work.25 mm dia
Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends inspection boxes , iron hooks, cement concrete etc. complete in all respect up to the entire satisfaction of engineer in charge of work.PVC pipe of 32 mm dia
PVC pipe of 40 mm dia
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work.25 mm dia
Supply, Installation, Testing and Commissioning of wall / free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick bakelite sheet provided all along the bus bar and cable tray separating switches compartment and supporting suitable channel duly painted by 2 coat zinc / red oxide primer followed by 2 coats of powder coating in grey or required shade after rising. the panel having PU / Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipments / switch wear. Transport acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The Panel will be complete with control wiring (Copper) and fuse protection. (Only outer area on all sides shall be measured).
Supply and Fixing of copper bus bar duly tinned by means of SMC / DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with color coding heat shrinkable PVC insulation complete in all respect.
Supply and Fixing of rotary handle for ON / OFF operation of existing MCCB in the LT panel including fixing the same in position with all labour and material to required to complete the job in all respect.Rotary Handle up to 125 Amp., MCCB
Rotary Handle above 125 Amp., MCCB
Supply and erection of moulded case circuit brecaker single pole/ 4 pole on wall/ on existing pedestal including bounding to earth and making necessary connection required to complete the job the job in all respect up to the entire satisfaction of the Engineer -in - Charge of the work.4 pole MCCB 300 amp to 400 amp.
Supply and erection of heavy duty 4 pole ON load changeover load breaker switch comprising of switches 63 Amp. to 400 Amp. suitable for operation on 415 V 50 Hz AC supply complete with handle assembly having door interlock & padlocking arrangement on existing panel / including making necessary connections with petty material required to complete the job. 300 Amp. 4 pole ON load changeover switch
Supply and erection of Popup box with brush steel finish complete with 2 No. RJ 45 for data and two nos. 6 Amp socket outlet of UPS supply and including all petty material required to complete the job in all respect up to the entire satisfaction of the engineer-in-charge of the work. Model no. EDO 2BS of MK make or equivalent make of Schnieder or Legrand. (For Conference and Comettee Hall)
Supply and erection of Hotel Key Card with time delay inclusing cost of 40 Amp contactor complete with GI box and all petty material requried to complet the job in all respects upto the entire satisfation of the Engineer-in-Charge. Model no. 572230 & 412545 of Legrand make or equivelent make of Schneider and MK ( For VIP Rooms)
Supply and erection of DND and MMR indicator with bell push internal control unit for DND and MMR complete in all respect including all petty material required to complete the job in all respect upto the entire satisfation of the Engineer-in-Charge. Code no. 573461 & 573458 of Legrand make or equivelent make of Schneider and MK (for VIP Rooms)
Supply and fixing of under floor junction box made of standard gauge aluminium sheet 1 trap single compartment for data/voice or UPS, size 150mm x 150mm x 60mm-75mm depth including cutting the floor to the required size and all repair work in CC mortor 1:2:4 after fixing the junction box, finish the floor to make goods the same and complete the job in all respect upto the entire satisfaction of the Engineer - In- Charge. (Make:- M.K., Schneiderr or Legrand)
Supply, Installation, Testing & Commissioning of Compact Air insulated aluminium TPN rising mains over all dimension should be as per standard size of manufacturer. Powder coated in approved color, fabricated of 1.6 mm thick GI sheet with plug in point provision, IP-54 protction rise of 55 Degree over an ambeint of 40 Degree temprature, alongwith thrust pad, fire barrier, suitable for 415 Volt 50 Hz AC and 2 No. aluminium earth strip as per IEC 604391 I & II, complete in all respect upto the entire satisfaction Engineer in charge of work. Make-C&S/Seimens/Legrand/Schneider Electric, 160 Amp., 10 KA SC for 1 Second.
Supply, Installation, Testing & Commissioning of End feed unit with FPMCCB of following size/capacity suitable for compact bar duct as above, complete in all respect upto the entire satisfaction Engineer in charge of work. Make-C&S/Seimens/Legrand/Schneider Electric.160 Amp., 25 KA, 4 Pole MCCB
Supply, Installation, Testing & Commissioning of support bracket of following size/capacity suitable for compact bar duct as above, complete in all respect upto the entire satisfaction Engineer in charge of work. Make-C&S/Seimens/Legrand/Schneider Electric.160 Amp.
Supply, Installation, Testing & Commissioning of End cover/End cap of following size/capacity suitable for compact bar duct as above, complete in all respect upto the entire satisfaction Engineer in charge of work. Make-C&S/Seimens/Legrand/Schneider Electric.160 Amp.
Supply, Installation, Testing & Commissioning of Tap off box of following size/capacity suitable for compact bar duct as above, complete in all respect upto the entire satisfaction Engineer in charge of work. Make-C&S/Seimens/Legrand/Schneider Electric.32/63/100 Amp.
Supply, Installation, Testing & Commissioning of manual draw-out type Air circuit breaker (ACB) 4-Pole, microprocessed based of 800 Amp. 50 KA breaking capacity in existing panel, complete in all respect upto the entire satisfaction Engineer-in-charge of work as per approved list.
S/E of perforated cable tray made of 14 SWG MS sheet of following size hanged in RCC slab with 2 No. 12 mm full thread galvanised MS rod upto 1 Mtr. With support angle of 25mm x 25mm x 5mm duly painted, complete in all respect upto the entire satisfaction Engineer in charge of work. 50mm x 300mm x 50mm
50mm x 450mm x 50mm
Supply, erection ,testing and commissioning of electric traction passenger elevator of OTIS / KONE / MITUSUBHSHI / KINETIC HUNDAI / SCHINDLER / HITACHI / JOHNSON / ORBIS make suitable for 8 persons (544kg. weight) having speed @ 1meter per second to travel from ground floor + 3 upper floors with 4 stops,4 opening with ARD system and full height infra red safety and as per technical specifications attaced, upto the entire satisfaction of the Engineert -in- charge of work.
Supply, erection ,testing and commissioning of electric traction passenger elevator of OTIS / KONE / MITUSUBHSHI / KINETIC HUNDAI / SCHINDLER / HITACHI / JOHNSON / ORBIS make suitable for 13 persons (884 kg. weight) having speed @ 1meter per second to travel from ground floor + 3 upper floors with 4 stops,4 opening with ARD system and full height infra red safety and as per technical specifications attaced, upto the entire satisfaction of the Engineert -in- charge of work.
Netromics Engineering Solutions Private Limited
Shree Shyam Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .