| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC 32 GRAND SQUARE DANAPUR CANTT PATNA PIN 801503 | PATNA | PATNA | BIHAR | 801503 | ₹28.1 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹28.9 L+₹80,118.65 (2.85%)Rejected-Finance B 150 GROUND FLOOR BACK SIDE PANDAV NAGAR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹28.9 L+₹80,118.65 (2.85%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹29.6 L+₹1.5 L (5.23%)Rejected-Finance H NO 106 D POCKET A MAYUR VIHAR PHASE II DELHI 110091 | DELHI | EAST DELHI | DELHI | 110091 | ₹29.6 L+₹1.5 L (5.23%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹29.9 L+₹1.7 L (6.16%)Rejected-Finance VILL JAMALPUR P O NAYA MAHMMADPUR DISTT BHOJPUR ARA PIN 802163 | ARA | BHOJPUR | BIHAR | 802163 | ₹29.9 L+₹1.7 L (6.16%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹30.1 L+₹2.0 L (6.98%)Rejected-Finance | ₹30.1 L+₹2.0 L (6.98%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹26.8 L
EMD Value
₹53,600
Closing Date
15 Jan 2022, 6:00 pmClosed
GE DANAPUR
GE MES DANAPUR
SPL REPAIR TO BLDG NO 19 RATION STORES AT MH AREA AND PROVN OF CERTAIN MINOR WORK IN AGE BRII UNDER GE DANAPUR CANTT
2021_MES_493395_1
8557/E8
Open Tender
Civil Works
Item Rate
180 days
DANAPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE DANAPUR
₹53,600
Yes
19 Feb 2022
8 Dec 2021
21 Jan 2022
8 Dec 2021
15 Jan 2022
8 Jan 2022
9 Dec 2021 - 21 Dec 2021
Amount
Dismantling of floor, walls tiles including bedding but backing and rubbish off permises all as specified.
M&L for Coloured glazed ceramic tiles (450 x 300)x 6 to 7mm thick (digital type) on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or colored cement to match complete including 10 mm thick rendering on fair faces of brick work or concrete surfaces, in cement mortar 1:4 all as specified and directed for shade, pattern and laying of tiles complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick wall in cement mortar (1:6) finished surface even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finished the surfaces even and fair without using extra cement complete all as specified and directed. Note : Liquid WPC will be measured and paid separately.
Supply only water proofing compound (liquid),ISI marked complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (40mm graded stone agg) in fdn, sub base, mass concrete & cinder concrete etc. complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (40mm graded agg) in fdn, sub base, mass concrete & cinder concrete etc. complete.
M&L PCC 1:5:10 type E-2 (40mm graded stone agg) in fdn, sub base, mass concrete & cinder concrete etc. complete.
M & L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed.
M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 Design Mix using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles and mass concrete complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item)
M & L for use and waste of formwork to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beams; and similar works; in rough finished flat surface of concrete complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over upto as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed..
Demolition of brick work built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed
~Ditto~ all as per item Ser No 17.00 above but except bricks complete all as specified and directed.
S & F powder coated aluminium window sliding shutter three track with following specification:- (a) chowkhat frame of size 81.25 x 38.10 x1.25 mm @ 0.781Kg/RM (b) Style/Vertical member of size 47.62 x 44.45 x 1.18 mm @ 0.667Kg/RM (c) Top and bottom rail of size 47.62 x 44.45 x 1.18 mm @ 0.667Kg/RM (d) Partialy 0.63 mm dia stainless steel wire netting mosquito proof with fixing arrangment. (e) Partialy 5.00 mm thick tinted glass fixing with rubber gasket. (f) Aluminum and PVC beading as per requirment as in fixing for paticle board & Glass, joing cleat including locking arrangement. etc
Demoliton of cement concrete in ground floor paving n exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate /plinth protection laid in suitable panels finished even and fair all as spd . 6mm Joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 gde and three part of sand ( all by weight) complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of oil bound distemper over a coat of primer over and including 3 mm thick Birla/ JK wall putty complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of new or untreated steel surface of any description exc. 10 cm. in width or girth and applying two coats of synthetic enamel paints, over a coat of red oxide primer, complete all as specified.
S&F 15 mm bore GI Tubing medium grade with all med grade GI fittings fixed to walls, ceilings or laying in floors in comp all as spd and directed
S&F 20 mm bore GI Tubing medium grade with all med grade GI fittings fixed to walls, ceilings or laying in floors in comp all as spd and directed
S&F 25 mm bore GI Tubing medium grade with all med grade GI fittings fixed to walls, ceilings or laying in floors in comp all as spd and directed
S&F Aluminium handles, cast type, anodized 150 mm size comp ISI Marked complete all as specified and directed
S&F 100 mm size butt hinges extruded aliminium alloy with galvanised MS hinge pin Type B-21 complete all as specified and as directed.
M&L for water proofing treatment on non approachable / non accessible roof surface horizontal and vertical surfaces in following sequence through manufacturer / authorized applicator of the manufacturer complete all as specified and directed :- (i) Properly cleaning and drying concrete surfaces. (ii) Applying a coat of oxidized bitumen based solvent primer @ 0.3 Kg / sqm by the same membrane manufacturer of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. (iii) Applying evenly tack coat of industrial bitumen 85 / 25 grade @ 1.2 Kg / sqm. (iv) Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3 Kg / sqm water proofing membrane, black finished reinforced with glass fibre matt with 100 mm over laps over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto 0°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane (v) Applying a coat of bituminous aluminium paint @ 100 gm / sqm over and including a coat of hot air blown grade bitumen of grade 85 / 25 @ 1.2 Kg / sqm duly sanded over membrane complete all as specified and directed. NOTE:- The polymeric water proofing membrane shall be extended upto parapet walls and inserted in walls by cutting groove and making good with cement mortar 1:3 as directed.
Boring holes 3m deep and 300 mm dia of pile in soil for Single under reamed piles and getting out and disposal of soil to a distance of n.exc 50 m complete all as specified and directed.
Cutting openings, through brick walls built with cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not all as specified and directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and directed
M & L for providing reinforced cement concrete M-25 Design Mix using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and like complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item)
M & L for providing reinforced cement concrete M-25 Design Mix using 20 mm graded stone aggregate as in columns, pillars, piers, posps and struts complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item)
M & L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exc. 200 mm thick horizontal or slopping in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete complete all as specified and directed.
M & L for use and waste of formwork to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, opening in concrete wall, sides of RCC slab, RCC / PCC bends in walls or similar work thickness exc. 10 cm and not exc. 20 cm in rough finished surfaces of concrete complete all as specified and directed.
M&L rendering 10 mm thick in cement mortar (1:3) on ceiling/chajja's finished surface even and smooth without using extra cement, complete all as specified and directed.
M & L Preparing new plastered surfaces of ceiling and applying three coats of white wash etc complete all as specified and directed.
M & L Preparing new plastered surfaces of wall and applying three coats of white wash etc complete all as specified and directed.
S & F Vitreous china wash down water closet pan ( pedestal pattern ) floor mounted cascade type of size 380 x660x765mm Bowl for coupled WC with UF soft close slim seat cover, and fixing of flushing cistern, brackets, flushing pipe etc, s, complete all as specified and directed (Make : Jaquar cat part no LYS-WHT-38201)
S&F Vitreous china wash hand basin size 555 X 425 X 195MM, Oval type and fixing in wall/platform complete all as specified and as directed. Make : Jaquar CAT PART - FLS-WHT-5701
M&L for 18-20 mm thick granite tiles machine cut, bedded and jointed with Grey cement slurry and pointed with white cement mixed with pigment to match the shade of Granite including grinding and polishing over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
S&F 32 mm dia waste coupling brass chromium plated with PVC waste pipe complete all as specified and as directed.
S&F 15mm bore Pillar cock for wash hand basin with left hand operating knob with 450 long Braided house and fixed complete all as specified and as directed. Make : Jaquar CON -123BKN or equivalent of make specified.
S&F in repair 15 mm bore CP bib tap of fancy type with long shank with wall flange with cast copper alloy of crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule fixed complete all as specified and directed. Make : Jaquar CON -047KN or equivalent of make specified.
S&F in repair CP angle stop cock 15 mm with wall flange complete all as specified and directed. Make : Jaquar CQT-23059 or equivalent of make specified.
S&F CP two way angle stop cock 15 mm with wall flange complete all as specified and directed. Make : Jaquar CON-041KN or equivalent of make specified.
S&F Double Arm wall mounted Reversible plain/Magnifying (X3) pivotal mirror complete all as specified and directed. (Make : Jaquar ACN-1193N) or equivalent of make specified.
S&F health faucet of CP head with flexible pipe of one mtr length including wall hook for EWC complete all as specified and as directed. Make : Jaquar ALD-CHR-563 or equivalent of make specified.
S&F flushing jet spray for pedestal pattern EWC including 1.00 m long flexible pipe and brass chromium plated nuts complete all as specified and as directed.
S&F CP toilet paper holder with flap fixed to wall with CP screws and wooden/plastic cleats complete all as specified and as directed.(Make : Jaquar AHS-1551 or equivalent of make specified.
S&F PVC connection 15 mm size with CP nuts of length 450 mm complete all as specified and as directed.
S&F 100 mm dia grating doom of stainless steel complete all as specified and as directed.
S&F CP towel rail 600 mm long fixed with & iron CP brass screw and wooden/plastic cleats complete all as specified and as directed. Make : Jaquar ACN - 1111BNM or equivalent of make specified.
S&F glass shelf 600mm long including fixed with CP brass screw and wood cleats / rowel plug with wall complete all as specified and as directed. Make : Jaquar CAN-1171N or equivalent of make specified.
S&F CP towel ring round with round flange & iron CP brass screw and wooden/plastic cleats complete all as specified and as directed. Make : Jaquar CAN-1121BN or equivalent of make specified.
S&F over head shower size 200 x200mm square shape single flow (ABS Body chrome plated with Graey face plate ) with Rubit cleaning cistern with complete fittings/accessories and all as specified and as directed. Make : Jaquar OHS-35497 or equivalent of make specified.
S&F bath room cabinet mirror size 450 x 600mm including all accessories with fittings complete all as directed by Engr-in-Charge Make : Paryag/Sintex
S&F Wall Mixer with 115 mm Long Bend Pipe for Connection to Overhead Shower (with Bush & Piston Diverter Fitting) with Aeratorr complete all as specified and as directed. Make : Jaquar COP-110PM or equivalent of make specified.
S&F anodized aluminium grill (diamond shape of approx size 100x100mm) made out of aluminium flat of size 4x5mm as approved by Engr-in-Charge/GE for window/ ventilators etc complete all as specified & directed.
S&F Solid PVC Double door frame of size 50mm x 95mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per specification & drawing, supplying and specified and directed
S&F Factory Made Solid PVC Moulded Door Shutter with Particle Board Core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing etc complete all as specified & directed.
S&F 200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed..
M&L for Non -Skid Ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm , in floors etc over and including15mm thick screed bed in cement mortar 1:6. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) triple layer hoisted and fixed in position all as specified in SSR Pt-I of 1000 Ltr capacity including CP tank nipple complete all as specified and directed.
S&F Gun metal, globe or gate valve with iron wheel head, 20 mm bore, screwed both ends for iron pipe complete all as specified and directed.
S&F Ball valves 20mm dia high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with brackets etc of 110 mm dia. complete all as specified and directed.
~Ditto~ all as per item Ser No70.00 above but 75 mm bore complete all as specified and directed.
S & F PVC (SWR) bends any radius of 75 mm dia complete all as specified and directed.
S & F PVC (SWR) bends any radius of 110 mm dia complete all as specified and directed.
S & F PVC (SWR) bends any radius of 110 mm dia provided with access door complete all as specified and directed.
S & F PVC (SWR) vent cowl of 75 mm dia complete all as specified and directed.
S & F PVC (SWR) vent cowl of 110 mm dia complete all as specified and directed.
S & F 75/100 mm bore PVC (SWR) floor trap, plain with grating including jointing to waste pipe, all as specified and directed.
Taking down and Refixing Machine Pressed precast glazed colour reflective PCC interlocking paver block 60mm thick mixed with grey cement and pigment, laid dry and bedded over 50 mm thick sand cushion complete all as specified and as directed by Engr-in-Charge. 1. The pattern of paver block shall be approved by GE. 2. Sand cushion shall be measured separately.
S&F steel work in tubular trusses, Purlins and rafter including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 complete all as specified and as directed by Engr-in-Charge.
M & L for mild steel plates (Plain OR Chequered) channels, FE-410-W (Grade E-250) quality, square cut or notched (ordinary and counter sunk) forming holes, without anu attachment complete all as specified and directed by E-in-Charge
S& Framed work as in doors or gates/ railing such as arrow flower guard bar as directed by Engineer in charge of angle, square bar , flat iron or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including welding Conforming to Fe 410 -W (Gde-E- 250) complete all as specified and directed Note:-Drawing of door /gate / railing shall be approved by Engineer-in-charge/Accepting officer
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of colour having tensile strength of 550 Mps as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by E-in-Charge
M&L for vitrified heavy duty (dura stone) tiles 300x300x9 to 10 mm thick in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L Point wiring complete with cable PVC, insulated, unsheathed, 1100 volts grade conforming to IS-694, 1.5 Sq mm (nominal area) FRLS stranded with copper conductor single core drawn through and including non metallic rigid PVC conduit 20mm dia,medium grade and conduit accessories concealed wiring system by cutting of wall and making good in walls disturbed surface, with sunken type pressed steel/welded MS terminal boxes not less than 1.6mm thick MS Sheet concealed in wall with hold fasts duly painted with two coat of black bituminious paint over a coat of red oxide, 3 mm thick laminated sheet cover for mounting of fittings like switches, socket outlets, regulators etc., including a run of PVC insulated unsheathed 1.5 Sq mm FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for the following: -
One light/ fan point controlled by one, one-way switch, SP, 5 Amps complete all as specified & directed.
One 5 pin 5 Amps socket out let point on the same board with other switches complete all as specified & directed
One switch socket outlet, 5 pin, 5 Amps, SP, on independent board complete all as specified & directed.
~Ditto~ All as per item No. 84.00 above but with 2.5 Sq mm cable for One 3 Pin, 5/15 Amps switch socket outlet on independent board complete all as specified and directed.
S&F Switch Piano, flush type, single pole, one way, 5 Amps, 230 Volt grade, ISI marked complete all as specified and directed.
S & F socket outlet flush type multipurpose 2 in 1, 5 pin 5 Amps 240 volts complete all as specified & directed.
S&F Switch Piano, flush type, single pole, one way, 15 Amps, 240 Volt grade, ISI marked complete all as specified and directed.
S & F socket outlet flush type multipurpose 2 in 1 , 3 pin 5 and 15 Amp, 240 volts complete all as specified & directed.
S&F lamp holder insulated body with back plate for batten/ angular fitting complete all as specified & directed.
S&F ceiling rose surface bakelite 63.50 mm dia, three terminals, complete all as specified & directed.
Supply and fixing Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole and neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete all as specified and as directed. Make : Legrand/Schneider/Siemens/L&T
Supply and fixing MCB SPN 5 to 32 amps 10 KA, C-series including connection complete all as specified and directed. Make : Legrand/Schneider/Siemens/L&T.
Supply and fixing MCB SP 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'C' type including connection complete all as specified and directed by Engr-In-Charge. Make : Legrand/Schneider/Siemens/L&T.
S&F in LED tube light fitting batten type single tube 1x 18/20 watt 230 volt wall/ ceiling mounted luminaire industrial type made of sheet metal box type suitable for T- 8 tube complete with electronic driver and bipin holder including one No tube 18/20 watt fixed with wall/ceiling incl fittings accessories and connecting with all accessories internally pre wired and incl connecting up with twin core twisted flexible copper conductor cable suitable size all as specified. Make of tube light fitting- Havells Cat No: REGALBATTENT8UPTO1X22WDSBSWH or equivalent model of Bajaj / Wipro/Crompton Greaves Make of Tube:- Havells Cat No. CRYSTAL1213T8DSTL18WLED865SGLASS or equivalent model of Bajaj/Philips/ CG.
Supply and fixing in repair LED batten tube light fitting 1x 9 watt 230 volt wall/ ceiling mounted luminaire with polycarbonate hoiusing and integrated electronic driver with all accessories internally pre wired and incl connecting up with twin core twisted flexible copper conductor cable suitable size all as specified. Make :- Havells Cat No. LUMILINEBS9WLED840SPCWH or equivalent model of Bajaj/Philips/ CG.
Supply and fixing LED bulk head 10 watt fittings environmental friendly ultra modern energy saving surface mounted decorataive bulk head fitting with driver and prewired and necessary electric connection with PVC insulated twin twisted flexible copper wire of size 0.75 Sqmm complete all as specified and as directed. Make: Havell's Cat No: HEXAFT10WLED857SSYMBOPC or equivalent model of Bajaj/CG/Philips.
S&F LED lamp 7/8 watt complete all as specified and directed.
S&F high performance metal body exhaust fan 300 mm sweep 900 RPM 240 volts, AC 50 Hz, heavy duty with suitable size MS sheet louver including connecting up to ceiling rose/ connector by three core sheathed copper cable of suitable size including cutting wall and making hole in round shape of suitable size making good the disturb suface to its original specification from both inner snd outer side of wall and four Nos suitable size nuts, bolts and washer with proper grouting in wall complete all as specified and directed. MAKE :- Havells cat part No. Turbo force SP or equivalent modle of Crompton Greaves / Usha
M&L sub main wiring with 2 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated (FRLS) unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor including one run of 2.50 sqmm (nominal cross sectional area) PVC insulated (FRLS) unsheathed cable with stranded copper conductor as continuous earth wire connected in common earth dolly drawn in PVC rigid non- metallic conduit complete all as specified and as directed. (NOTE : (i) Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length). Make of cable:-Polycab/Havell's/ Finolex
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 50 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (Make: HAVELLS/ POLYCAB/MESCAB) (NOTE: Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this schedule 'A' part).
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
M & L dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable and gentally hand ramming and consolidation etc. complete all as specified and directed. Note :- Thickness of sand 18 cm thick shall be measured after punning of sand.e.
M&L for bricks cover of old size bricks sub class 'B' with width equal to the length of the brick laid dry & flet abutted with with each other with gap between adjacent bricks n.exc 10 mm over UG cable for protection complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance exc. 50 m but not exc. 25 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to distance n. exc 50m & making good surface in soft soil complete all as specified & directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of colour having tensile strength of 550 Mps as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by E-in-Charge
M & L for plain cement concrete, type B-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for two coats of Apex weather paint of newly plastered surface over a coat of primer including preparation of surface complete all as specified and directed.
S & F of wire netting of Stainless steel wire 1.40 mm dia and size of mess 12 mm fixed with tinned tacks of galvanised wire staples complete all as specified and directed.
S&F medical grade copper pipes of size 28 mm outer dia (OD) x 26.2 mm inner ida (ID) and 0.9 mm thick for medical gases, complete with elbows, flanges, specials, other fitting and steel support, the copper pipes should be of solid drawn seamless deoxidised, un-arsenical, half hard, tempered and of degreased materials confirming to BS-EN 1057/13348 of copper pipe with colour coded complete all as specified and as directed. Make Mexflow/Metalco
S&F medical grade copper pipes of size 22 mm x 0.9 mm for medical gases, complete with elbows, flanges, specials, other fitting and steel support, the copper pipes should be of solid drawn seamless deoxidised, un-arsenical, half hard, tempered and of degreased materials confirming to BS-EN 1057/13348 of copper pipe with colour coded complete all as specified and directed.Mexflow/Metalco
S&F isolation valves 28 mm are to be ball valves with stainless steel ball and PTFE or Teflon seals. They shall be suitable for working pressure of 10.2 Kgs/Sqcm gauge. Valve shall be fitted into the pipe line by means of capiliary hard soldered joint containing silver, it should be opend/closed with help of handle with rotation of 90 degree complete all as specified and directed.
M & L for 40 mm bore GI steel tubing light grade ISI marked with all fittings for protection of oxygen pipe including necessary joints complete all as specified and directed.
Supply and fixing 4 Pole MCCB 100 to 125 Amp, 50 Hz, 415 V with rupturing capacity 35 KA suitable for Panel fitted with bus bar and connecting cable with providing lugs alongwith MCCB wall mounted enclosure as per requirement as per existing finishing complete all as specified and directed .
M&L Earthing complete with galvanised steel earth plate electrode 600mm X 600 mm X6.30mm thick burried directly in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to and including GI earth lead of GI strip 32X6mm size by means of steel bolts,nuts, check nuts and washers test points made of GI strip 40X8mm, 10 cm long , PCC 1:2:4 type B-1 in pit, angle iron 25X25X3mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways abd 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mess and light grade GI protection pipe 40mm bore upto 5m lenght for drawing in earth lead ,salt,charcol etc. including excavation and earth work in any type of soil , removal of surplus soil to a distance not exceeding 50m complete all as shown in electrical plate No. 5 of MES schedule 2009 part-I and connected complete all as specified including testing on completion.
M&L for Glaged ceremic coloured tile 7 mm thick in vertical surfaces such as exterior elevation tile matching with heritage finish , set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces including 10 mm thick rendering on fair faces of brick work or concrete surfaces, in cement mortar 1:4 complete all as specified and directed. Note:-size of tile and colour shall be approved by Accepting officer.
M&L for Ball brass valve/float valve of 15 mm bore high pressure with polythene float and fly complete, screwed for iron pipe or PVC ferrule and fixed in all as specified and directed of following size:-
Gun metal gate valves with iron wheel head screwed both ends suitable for 15mm bore GI pipe complete all as specified and di rected.
PAPPU ROY CONSTRUCTION
J K CONSTRUCTION
VAISHNAVI CONSTRUCTION
M/S Harsh Traders
SINHA CONSTRUCTION
MS BIJAY KUMAR AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .