Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC AT DHORI G M COLONY DIST BOKARO JHARKHAND | BOKARO | BOKARO | JHARKHAND | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | Rejected-Technical AT BATA GALI PHUSRO PO PHUSRO BAZAR DIST BOKARO | PHUSRO | BOKARO | - | Rejected-Technical Bid not be opened as per NIT terms | |
| 3 | Rejected-Technical AT PATEL NAGAR PO PHUSRO BAZA DIST BOKARO | PHUSRO BAZA | BOKARO | - | Rejected-Technical Bid not be opened as per NIT terms |
Tender Value
₹35.1 L
EMD Value
₹43,900
Closing Date
24 Jul 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer (EnM)
Office of the General Manager, Dhori Area
Maintenance of 11 kV feeder no. 1, 2 and 5 at GM Unit under MRSS, Dhori Area
2024_CCL_312499_1
GM(D)/SO(EnM)/DA/2024-25/17
Open Tender
Electrical and Maintenance Works
Item Wise
60 days
MRSS, Dhori Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹43,900
30 Aug 2024
12 Jul 2024
25 Jul 2024
13 Jul 2024
24 Jul 2024
13 Jul 2024
13 Jul 2024 - 16 Jul 2024
Amount
Part A: Feeder no. 01
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Erection of double pole 3 wire cross arm for 11 KV over head lines as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/channel iron, cross arm on steel tubular/ rail/ PCC pole for 11 KV as required.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required - Dog Conductor
Dismantling of overhead lines comprising of aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Re-connection of OH jumpers during preventive maintenance or breakdown
Providing of 11 kV, 400 A Male contact Blade suitable for Double Break GOS
11 kV, 400 A Female contact Blade suitable for Double Break GOS
Repairing of 400 Amps, 11KV grade GOS after dismantling of burnt/defective one phase Male & Female fixed contact, copper wirenet - 1.5 mtr, moving contact etc and replace from the materials along setting it on the pole structure
Erection of cradle guard as required.
Clamps, bolts nuts etc.
Supply of channel iron 75 mm x 40 mm x 7.14 kg / mtr cross arm for 2 wire OH Line complete with clamps bolts and nuts etc including drilling of holes of insulators pins and painting with primer and finish paint as required.
Lettering with black Japan paint of approved brand and manufacture for Numbering of poles.
Appling priming coat : With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)/steel works
Painting with aluminium paint of approved brand and manufacture to give an even shade - Two coats.
Part B: Feeder no. 02
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Erection of double pole 3 wire cross arm for 11 KV over head lines as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/channel iron, cross arm on steel tubular/ rail/ PCC pole for 11 KV as required.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required - Dog Conductor (30 spans X 3 wire X 50 mtr X 0.394 kg/m)
Dismantling of overhead lines comprising of aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Maintenance preventive Connection of OH jumper (during fault or re-connection during maintenance activity)
Providing of 11 kV, 400 A Male contact Blade suitable for Double Break GOS
11 kV, 400 A Female contact Blade suitable for Double Break GOS
Repairing of 400 Amps, 11KV grade GOS after dismantling of burnt/defective one phase Male & Female fixed contact, copper wirenet - 1.5 mtr, moving contact etc and replace from the materials along setting it on the pole structure
Erection of cradle guard as required.
Clamps, bolts nuts etc.
Supply of channel iron 75 mm x 40 mm x 7.14 kg / mtr cross arm for 2 wire OH Line complete with clamps bolts and nuts etc including drilling of holes of insulators pins and painting with primer and finish paint as required.
Lettering with black Japan paint of approved brand and manufacture for Numbering of poles. ( 7 cm size of one letter, 140 cm per pole x 106 nos = 14840 cm )
Appling priming coat : With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)/steel works. Poles (106 nos x 5.746 sqm/no)
Painting with aluminium paint of approved brand and manufacture to give an even shade - Two coats.
Part C: Feeder no. 05
Erection of steel tubular pole or rail pole strut in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supplying of two length of channel iron 75 mm x 40 mm x 6 mm (7.14 kg / mtr ) double pole cross arm for three wire 11 KV OH line conductor complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm MS flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arm together, including drilling holes for insulator pins, bolts nuts and washers etc (as per drawing) and painting with primer and finish paint as requied.
Erection of double pole 3 wire cross arm for 11 KV over head lines as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/channel iron, cross arm on steel tubular/ rail/ PCC pole for 11 KV as required.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required - Wolf Conductor (45 spans X 3 wire X 50 mtr X 0.726 kg/m)
Dismantling of overhead lines comprising of aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Maintenance preventive Connection of OH jumper (during fault or re-connection during maintenance activity)
Providing of 11 kV, 400 A Male contact Blade suitable for Double Break GOS
11 kV, 400 A Female contact Blade suitable for Double Break GOS
Repairing of 400 Amps, 11KV grade GOS after dismantling of burnt/defective one phase Male & Female fixed contact, copper wirenet - 1.5 mtr, moving contact etc and replace from the materials along setting it on the pole structure
Supply of 6 SWG G.I. wire. (2550 mtr x 0.131 kg)
Erection of cradle guard as required.
Clamps, bolts nuts etc.
Supply of channel iron 75 mm x 40 mm x 7.14 kg / mtr cross arm for 2 wire OH Line complete with clamps bolts and nuts etc including drilling of holes of insulators pins and painting with primer and finish paint as required.
Providing of 10 mm X 25 mm long GI bolt with nut etc
Dismantling of pole in cement concrete foundation etc. as required
Total impact of GST for the purpose of CTC
M/S UNNATI ELECTRICAL WORKS
M/S P S ENTERPRISES
techsummary_323851.pdf
PDF • 0.18 MB
finsummary_323851.pdf
PDF • 0.18 MB
WO17A.pdf
PDF • 2.12 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .