Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹35.5 L+₹2.5 L (7.51%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹36.8 L+₹3.8 L (11.4%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹38.5 L+₹5.5 L (16.7%)Rejected-Finance NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹39.7 L+₹6.7 L (20.3%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
9 Sept 2023, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
PROVN OF 135 X GEYSERS CAPACITY 25 LTRS AND 270 EXHAUST FANS IN JCOS / OR MD ACCN (DHAN SINGH THAPA ENCLAVE) AND ADDITIONAL / ALTERATION TO CERTAIN ELECTRICAL POINT / FITTINGS IN ILP AREA UNDER AGE E/M AT SURATGARH MIL STN
2023_MES_613545_1
GE (A) SOG - Token No 39/23-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SURATGARH
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY SURATGARH
₹95,000
Yes
11 Oct 2023
14 Aug 2023
11 Sept 2023
14 Aug 2023
9 Sept 2023
28 Aug 2023
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil & getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F 15mm dia stop valve cast copper alloy, fancy type with, chromium plated long shank and cup (concealed type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unsheathed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point controlled by one way switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 7 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 7 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per Srl item No. 7 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 5 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F electronic fan regulator suitable for ceiling fan 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
S&F Energy saving 9/10 watt environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs, IP 65 protection fixed on wall complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No HEXAFT10WLED857SSY MBOPC / Syska Cat part No SSK-BH-9W / Crompton cat part No LBHE-10-CDL or equivalent cat part No of makes mentioned in Appendix 'A' here-in-after.
Supply, fixing and testing LED Street / Security light fitting of 30 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge.
Notes for srl Item No 19 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
S&F flush mounting factory made SPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F flush mounting factory made SPN DB 8 way, 240 Volt, Single door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F flush mounting factory made VTPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 160 Amps copper bus bar, with 02 neutral bar, 02 earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F MCB 40 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F MCB 63 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F MCB 63 Amps, Triple Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F MCB 100 Amps, Triple Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F rigid non metalic pvc conduit of dia 20mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accesorries such as couplers, lock nuts, saddles pipe hoses etc complete all as specified and as directed by Engineer-in-charge.
S&F as in repair flush mounting factory made VTPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 160 Amps copper bus bar, with 02 neutral bar, 02 earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F Sub main wiring complete with 2 single core 4 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 4 Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 4 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F in replacement Sub main wiring complete with 2 single core 4 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 4 Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 4 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F exhaust fan 300 mm sweep, heavy duty, double ball bearing copper wound , steel body, 900 RPM trans air with louver shutter, suitable for operation on 230 volts, single phase , AC and connecting up including 2 core,1.0 sqmm PVC insulated & PVC sheathed copper conductor flexible cable drawn in flexible conduit complete all as specified & directed by Engr-in-charge.
S&F electric water heater, storage type steel body with stainless steel inner tank and heating element upto 2KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc including grouting 4 Nos bolts in PCC (1:2:4) block in wall and making good the disturbed surfaces matching with existing including making connection to elerctric supply complete all as specified and directed by the engr-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engr-in-charge. Notes :- (i) Cost of GI wire upto 7.5m is included in this item. (ii) PCC 1:2:4, Excavation, earthwork is included in the quoted rate of this item. (iii) Cost of GI tubing upto 7.5m is included in the quoted rate of this item. (iv) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (v) Minimum weight of reinforcement for RCC cover shall be 1 KG.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 3mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engineer-in-charge. Notes :- (i) Cost of GI wire upto 7.5m is included in this item. (ii) PCC 1:2:4, Excavation, earthwork is included in the quoted rate of this item. (iii) Cost of GI tubing upto 7.5m is included in the quoted rate of this item. (iv) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (v) Minimum weight of reinforcement for RCC cover shall be 1 KG.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 16 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 38 above but cable of cross sectional area 25 sq mm 4 core
All as per item No 38 above but cable of cross sectional area 70 sq mm 3.5 core including taking down old unserviceable cable
All as per item No 38 above but cable of cross sectional area 120 sq mm 3.5 core including taking down old unserviceable cable
Supplying, laying, jointing, commissioning and testing PVC insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 16 sq mm 4 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc including taking down old unserviceable cable complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
Supplying, jointing and testing heat shrinkable type, out door, end termination jointing kit, suitable for cable of size 70 to 120 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account..
Taking down existing loose fitted seviceable distribution box including MCB any type and capacity and refixing the same after doing proper fitting of loose boxes and MCBs including provn of fresh connection wire of suitable size upto one mtr length complete all as specified and as directed by Engineer-in-charge.
Suppyling, installing, testing and commissioning of factory made outdoor type bus bar chamber having MCCB 125 Amps, 4 pole, 415 volts, 3 phase, 4 wire, 50 Hz, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the 160 Amps aluminium bus bar fixed horizontally in staggred manner minimum length 450mm, 3 phases and neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty DMC insulators duly connected with 160 Amps MCCB including provision for taking out incoming and outgoing cable detacheable plate at bottom for cable entry and making six Nos hole in each bus bar including with bottom frame made out of angle iron 50mm x 50mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and directed by Engineer-in-Charge. Note :- (i) Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account. (ii) All cables to be connected with busbar will be properly thimbles.
Suppyling, installing, testing and commissioning of factory made outdoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :-
Contd/-… item No 49 Incoming (a) 400 Amps aluminium bus bar including Neutral and three phase - 01 Set (b) MCCB 250 Amps, 36 KA, 4 Pole, 415 volts thermal Magnetic release type - 01 No Outgoing (a) MCCB 63 Amps, 25 KA, 4 Pole, 415 volts, thermal Magnetic release type - 08 Nos (b) Digital voltmeter and ampere meter flush type 96x96 mm including CTs suitable size - Each Seprately (c) Internal all links & control cable and indicators - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
All as per item No 49 above but comprising of following accessories :- Incoming (a) 400 Amps aluminium bus bar including Neutral and three phase - 01 Set (b) MCCB 200 Amps, 36 KA, 4 Pole, 415 volts, thermal Magnetic release type - 01 No Outgoing (a) MCCB 63 Amps, 25 KA, 4 Pole, 415 volts, thermal Magnetic release type - 06 Nos (b) Digital voltmeter and ampere meter flush type 96x96 mm including CTs suitable size - Each Seprately (c) Internal all links & control cable and indicators - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account. ---------------------------------------------------------------------------- Note :- A sum of Rs. 119935/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 21 (Schedule of Credit) of Tender documents.
SAHIL BUILDERS
Gupta Suppliers
M/S GODARA CONSTRUCTION CO.
M/s Rohit Construction Co.
KARNI ELECTRICAL CORRPORATION/ANKIT YADAV
SRI SAI CONSTRUCTION COMPANY
B.K. ROY & SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .